Ali Öztürk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Öztürk has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Murat Duman
Division of Pediatric Emergency Care, Department of Pediatrics, Dokuz Eylul University Faculty of Medicine, Izmir, Turkey
4 shared publications - Durgül Yılmaz
DOKUZ EYLÜL ÜNİVERSİTESİ, TIP FAKÜLTESİ
2 shared publications - Emel Ulusoy
Faculty of Medicine, Department of Pediatrics, Division of Pediatric Emergency Care, Dokuz Eylul University, Izmir, Turkey
2 shared publications - Hale Çitlenbik
Division of Pediatric Emergency Care, Department of Pediatrics, Faculty of Medicine Dokuz Eylul University Izmir Turkey
2 shared publications - Nihan Şık
Division of Pediatric Emergency Care, Department of Pediatrics, Faculty of Medicine Dokuz Eylul University Izmir Turkey
2 shared publications - Anıl Er
Division of Pediatric Emergency Care, Department of Pediatrics, Dokuz Eylul University Faculty of Medicine, Izmir, Turkey
1 shared publication
Latest Publications
- 4 October 2023
- Published by Galenos Yayinevi in Turkish Journal of Pediatric Emergency and Intensive Care Medicine
- Vol. 10 (3) , 162-168
Utility and Efficacy of Trauma Scoring Systems in Multiple Trauma Children with Cranial Computed Tomography
- 4 October 2023
- Published by Galenos Yayinevi in Turkish Journal of Pediatric Emergency and Intensive Care Medicine
- Vol. 10 (3) , 162-168
Utility and Efficacy of Trauma Scoring Systems in Multiple Trauma Children with Cranial Computed Tomography
- 8 April 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 25 (4) , 957-963
The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma
Purpose To determine the accuracy of bedside sonographic measurements of optic nerve sheath diameter (ONSD) and ONSD/eyeball transverse (ETD) diameter ratios to predict space-occupying lesions (SOLs) or elevated intracranial pressure (ICP) in pediatric head trauma. Methods Children who presented to the emergency department with head trauma and underwent cranial computed tomography (CT) were enrolled and examined by ocular ultrasonography (US), and the ONSD was measured at 3 mm posterior to the globe and ETD were measured. Ratios of ONSD at 3 mm/ETD were calculated. All ONSD measurements and ratios were calculated from cranial CT images. Results Subjects with elevated ICP had increased ONSD measurements and ratios. To predict elevated ICP, the AUC for ONSD at 3 mm was 0.956 (95% CI 0.896–1). At a cut-off level of 5.1 mm, the sensitivity and specificity of ONSD 3 mm values for elevated ICP were 92.9% and 94.0%. For the ONSD 3 mm/ETD ratio, it was 0.980 (95% CI 0.959–1). At a cut-off level of 0.22, the sensitivity and specificity were 100% sensitivity and 88.0%. All sonographic ONSD measurements and ratios were significantly correlated with readings calculated from cranial CT images. Conclusion Sonographic ONSD measurements and ratios were found to be quite sensitive to detect elevated ICP on cranial CT images. Additionally, there was a significant correlation between measurements calculated by ocular US and cranial CT scans. Bedside ocular US seems to be a promising and useful tool to determine ICP in children with head trauma.
- 8 April 2022
- Published by Springer Nature in Journal of Ultrasound
- Vol. 25 (4) , 957-963
The role of sonographic optic nerve sheath diameter measurements in pediatric head trauma
Purpose To determine the accuracy of bedside sonographic measurements of optic nerve sheath diameter (ONSD) and ONSD/eyeball transverse (ETD) diameter ratios to predict space-occupying lesions (SOLs) or elevated intracranial pressure (ICP) in pediatric head trauma. Methods Children who presented to the emergency department with head trauma and underwent cranial computed tomography (CT) were enrolled and examined by ocular ultrasonography (US), and the ONSD was measured at 3 mm posterior to the globe and ETD were measured. Ratios of ONSD at 3 mm/ETD were calculated. All ONSD measurements and ratios were calculated from cranial CT images. Results Subjects with elevated ICP had increased ONSD measurements and ratios. To predict elevated ICP, the AUC for ONSD at 3 mm was 0.956 (95% CI 0.896–1). At a cut-off level of 5.1 mm, the sensitivity and specificity of ONSD 3 mm values for elevated ICP were 92.9% and 94.0%. For the ONSD 3 mm/ETD ratio, it was 0.980 (95% CI 0.959–1). At a cut-off level of 0.22, the sensitivity and specificity were 100% sensitivity and 88.0%. All sonographic ONSD measurements and ratios were significantly correlated with readings calculated from cranial CT images. Conclusion Sonographic ONSD measurements and ratios were found to be quite sensitive to detect elevated ICP on cranial CT images. Additionally, there was a significant correlation between measurements calculated by ocular US and cranial CT scans. Bedside ocular US seems to be a promising and useful tool to determine ICP in children with head trauma.
- 1 February 2022
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 61 (1) , 103288
Pediatric trauma: Blood product transfusion characteristics in a pediatric emergency department, a single center experience
- 1 February 2022
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 61 (1) , 103288
Pediatric trauma: Blood product transfusion characteristics in a pediatric emergency department, a single center experience
- 18 December 2020
- Published by Galenos Yayinevi in Turkish Journal of Pediatric Emergency and Intensive Care Medicine
- Vol. 7 (3) , 117-121
Clinical and Laboratory Findings in Early Diagnosis of Bacterial Meningitis
- 18 December 2020
- Published by Galenos Yayinevi in Turkish Journal of Pediatric Emergency and Intensive Care Medicine
- Vol. 7 (3) , 117-121
Clinical and Laboratory Findings in Early Diagnosis of Bacterial Meningitis