Yung-Jhe Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yung-Jhe Yan has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Mang Ou-Yang
National yang Ming Chiao Tung University
11 shared publications - Jin-Chern Chiou
National yang Ming Chiao Tung University
3 shared publications - Chih-Hsun Lin
Academia Sinica
2 shared publications - Meng-Hsin Hsiao
Institute of Electrical and Control Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
2 shared publications - Tzu-Yi Yu
Industrial Technology Research Institute, Hsinchu 30010, Taiwan
2 shared publications - Yu-Hsiang Tsai
Institute of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan
2 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26  (20) , 30438-30449
Radiation-Hardening Techniques and In-Orbit Robustness Validation for Trapezoidal Dual-Axis Sun Sensors in LEO Environments
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26  (20) , 30438-30449
Radiation-Hardening Techniques and In-Orbit Robustness Validation for Trapezoidal Dual-Axis Sun Sensors in LEO Environments
- Open Access
Design, Implementation, and Verification of High-Accuracy Trapezoidal Dual-Axis Sun Sensors for LEO Satellite Attitude Determination
This paper presents a dual-axis sun sensor employing a cross-slit aperture in conjunction with a four-quadrant trapezoidal photodiode layout. The cross-slit configuration enhances angular sensitivity and resolution, while the trapezoidal photodiode geometry preserves a high signal-to-noise ratio at both near-normal incidence and large Sun angles, maintaining reliable directional discriminability around normal incidence. Compared with conventional quad-triangle photodiode layouts, the proposed trapezoidal geometry avoids the rapid collapse of the illuminated area near the triangular apex at large incidence angles, thereby preserving signal margin near the field-of-view boundary. System-level optical verification demonstrates that, after calibration, the proposed sensor achieves an angular accuracy of ±0.3° (3). To mitigate performance variations induced by temperature drift, an embedded shielded dummy photodiode is incorporated to provide a dark-current reference for compensation. Unlike compensation approaches that mainly rely on pre-characterization or offline calibration, the embedded shielded dummy photodiode provides an in situ, real-time dark-current reference for compensating for temperature-induced signal drift in the actual operating environment. Experimental results under dark conditions indicate that the embedded dummy photodiode served as a dark-current reference for compensating the temperature-dependent dark-current variation in the active photodiodes, reducing the peak-to-peak dark-signal variation by 96% over a temperature range from 20 °C to 120 °C. Furthermore, a pyramid-type sun-sensor architecture is proposed by integrating the dual-axis fine sun sensor with four wide-field coarse sun sensors. This system-level configuration extends the effective Sun field of view from the conventional 120°–180° range to approximately 280°, enabling near-hemispherical Sun-angle observability for enhanced attitude determination robustness.Open AccessDesign, Implementation, and Verification of High-Accuracy Trapezoidal Dual-Axis Sun Sensors for LEO Satellite Attitude Determination
This paper presents a dual-axis sun sensor employing a cross-slit aperture in conjunction with a four-quadrant trapezoidal photodiode layout. The cross-slit configuration enhances angular sensitivity and resolution, while the trapezoidal photodiode geometry preserves a high signal-to-noise ratio at both near-normal incidence and large Sun angles, maintaining reliable directional discriminability around normal incidence. Compared with conventional quad-triangle photodiode layouts, the proposed trapezoidal geometry avoids the rapid collapse of the illuminated area near the triangular apex at large incidence angles, thereby preserving signal margin near the field-of-view boundary. System-level optical verification demonstrates that, after calibration, the proposed sensor achieves an angular accuracy of ±0.3° (3). To mitigate performance variations induced by temperature drift, an embedded shielded dummy photodiode is incorporated to provide a dark-current reference for compensation. Unlike compensation approaches that mainly rely on pre-characterization or offline calibration, the embedded shielded dummy photodiode provides an in situ, real-time dark-current reference for compensating for temperature-induced signal drift in the actual operating environment. Experimental results under dark conditions indicate that the embedded dummy photodiode served as a dark-current reference for compensating the temperature-dependent dark-current variation in the active photodiodes, reducing the peak-to-peak dark-signal variation by 96% over a temperature range from 20 °C to 120 °C. Furthermore, a pyramid-type sun-sensor architecture is proposed by integrating the dual-axis fine sun sensor with four wide-field coarse sun sensors. This system-level configuration extends the effective Sun field of view from the conventional 120°–180° range to approximately 280°, enabling near-hemispherical Sun-angle observability for enhanced attitude determination robustness. - Open Access
- 12 May 2025
- Published by Elsevier in Smart Agricultural Technology
- Vol. 11
Hyperspectral signature-band extraction and adaptation for sugar content prediction on Ziziphus mauritiana and Syzygium samarangense
- 12 May 2025
- Published by Elsevier in Smart Agricultural Technology
- Vol. 11
Open AccessHyperspectral signature-band extraction and adaptation for sugar content prediction on Ziziphus mauritiana and Syzygium samarangense
- Open Access
- 23 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13  (14) , 8497
Real-Time Information Fusion System Implementation Based on ARM-Based FPGA
In this study, an information fusion system displayed fusion information on a transparent display by considering the relationships among the display, background exhibit, and user’s gaze direction. We used an ARM-based field-programmable gate array (FPGA) to perform virtual–real fusion of this system as well as evaluated the virtual–real fusion execution speed. The ARM-based FPGA used Intel® RealsenseTM D435i depth cameras to capture depth and color images of an observer and exhibit. The image data was received by the ARM side and fed to the FPGA side for real-time object detection. The FPGA accelerated the computation of the convolution neural networks to recognize observers and exhibits. In addition, a module performed by the FPGA was developed for rapid registration between the color and depth images. The module calculated the size and position of the information displayed on a transparent display according to the pixel coordinates and depth values of the human eye and exhibit. A personal computer with GPU RTX2060 performed information fusion in ~47 ms, whereas the ARM-based FPGA accomplished it in 25 ms. Thus, the fusion speed of the ARM-based FPGA was 1.8 times faster than on the computer.
- 23 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13  (14) , 8497
Open AccessReal-Time Information Fusion System Implementation Based on ARM-Based FPGA
In this study, an information fusion system displayed fusion information on a transparent display by considering the relationships among the display, background exhibit, and user’s gaze direction. We used an ARM-based field-programmable gate array (FPGA) to perform virtual–real fusion of this system as well as evaluated the virtual–real fusion execution speed. The ARM-based FPGA used Intel® RealsenseTM D435i depth cameras to capture depth and color images of an observer and exhibit. The image data was received by the ARM side and fed to the FPGA side for real-time object detection. The FPGA accelerated the computation of the convolution neural networks to recognize observers and exhibits. In addition, a module performed by the FPGA was developed for rapid registration between the color and depth images. The module calculated the size and position of the information displayed on a transparent display according to the pixel coordinates and depth values of the human eye and exhibit. A personal computer with GPU RTX2060 performed information fusion in ~47 ms, whereas the ARM-based FPGA accomplished it in 25 ms. Thus, the fusion speed of the ARM-based FPGA was 1.8 times faster than on the computer.
- Open Access
- 13 June 2023
- Published by MDPI AG in Preprints.org
Research on Information Fusion System Implementation Based on ARM-Based FPGA
This research uses ARM-based FPGA to implement the computation of a virtual-real fusion hardware system. It also evaluates the acceleration effect of virtual-real fusion execution speed after connecting related hardware acceleration and provides a reference for real-time information fusion system design. The hardware uses Xilinx Zynq UltraScale+ MPSoC ZCU102 Evaluation Kit. It also obtains color and depth images with Intel® RealsenseTM D435i depth cameras. This system receives image data through the Linux system built on the ARM and fed to the FPGA for object detection using CNN models. In addition, it develops a module for rapidly performing registration between the color images and the depth images. It can calculate the size and position of the display information on the transparent display according to the pixel coordinates and depth values of the human eye and the object. The fusion took about 47ms on a personal computer with a GPU RTX2060 and 25ms on the ZCU102. The acceleration is nearly 168%. Finally, the results were successfully transplanted into the retail display system for demonstration.
- 13 June 2023
- Published by MDPI AG in Preprints.org
Open AccessResearch on Information Fusion System Implementation Based on ARM-Based FPGA
This research uses ARM-based FPGA to implement the computation of a virtual-real fusion hardware system. It also evaluates the acceleration effect of virtual-real fusion execution speed after connecting related hardware acceleration and provides a reference for real-time information fusion system design. The hardware uses Xilinx Zynq UltraScale+ MPSoC ZCU102 Evaluation Kit. It also obtains color and depth images with Intel® RealsenseTM D435i depth cameras. This system receives image data through the Linux system built on the ARM and fed to the FPGA for object detection using CNN models. In addition, it develops a module for rapidly performing registration between the color images and the depth images. It can calculate the size and position of the display information on the transparent display according to the pixel coordinates and depth values of the human eye and the object. The fusion took about 47ms on a personal computer with a GPU RTX2060 and 25ms on the ZCU102. The acceleration is nearly 168%. Finally, the results were successfully transplanted into the retail display system for demonstration.
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93  (6) , 063105
Development and verification of the coaxial heterogeneous hyperspectral imaging system
A hyperspectral imaging system (HIS) is a helpful tool that acquires spatial and spectral information from a target. This study developed a coaxial heterogeneous HIS (CHHIS) to collect spectral images with wavelengths ranging from 400 to 1700 nm. In this system, a visible (VIS) spectrometer and a short-wave infrared (SWIR) spectrometer are combined with a coaxial optical path to share the same field of view. This structure reduces the complexity of spatial registration and maintains the scanning duration of two spectrometers as that of a single spectrometer. The spectrometers are also replaceable for extending the detecting spectral range of the system. The calibration methodologies, including spatial correction, spectral calibration, and reflectance calibration, were developed for this system. The signal-to-noise ratio of VIS and SWIR spectrometers in the CHHIS was up to 40 and 60 dB when the exposure time of the VIS and SWIR imaging sensors was 1000 and 10 ms, respectively. When the target distance was at 600 mm, the spatial error of VIS and SWIR images in the scanning direction was less than 1 pixel; these results proved that the system was stable.
- 1 June 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93  (6) , 063105
Development and verification of the coaxial heterogeneous hyperspectral imaging system
A hyperspectral imaging system (HIS) is a helpful tool that acquires spatial and spectral information from a target. This study developed a coaxial heterogeneous HIS (CHHIS) to collect spectral images with wavelengths ranging from 400 to 1700 nm. In this system, a visible (VIS) spectrometer and a short-wave infrared (SWIR) spectrometer are combined with a coaxial optical path to share the same field of view. This structure reduces the complexity of spatial registration and maintains the scanning duration of two spectrometers as that of a single spectrometer. The spectrometers are also replaceable for extending the detecting spectral range of the system. The calibration methodologies, including spatial correction, spectral calibration, and reflectance calibration, were developed for this system. The signal-to-noise ratio of VIS and SWIR spectrometers in the CHHIS was up to 40 and 60 dB when the exposure time of the VIS and SWIR imaging sensors was 1000 and 10 ms, respectively. When the target distance was at 600 mm, the spatial error of VIS and SWIR images in the scanning direction was less than 1 pixel; these results proved that the system was stable.
- Open Access
- 25 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11  (7) , 852
Using System Identification to Construct an Inherent Model of Pupillary Light Reflex to Explore Diabetic Neuropathy
This study proposed a pupillary light reflex (PLR) inherent model based on the system identification method to demonstrate the dynamic physiological mechanism of the PLR, in which pupillary constriction and dilation are controlled by the sympathetic and parasympathetic nervous system. This model was constructed and verified by comparing the simulated and predicted PLR response with that of healthy participants. The least root-mean-square error (RMSE) of simulated PLR response was less than 0.7% when stimulus duration was under 3 ms. The RMSE of predicted PLR response increased by approximately 6.76%/s from the stimulus duration of 1 ms to 3 s, when the model directly used the parameters extracted from the PLR at the stimulus duration of 10 ms. When model parameters were derived from the regression by the measured PLR response, the RMSE kept under 8.5%. The model was applied to explore the PLR abnormalities of the people with Diabetic Mellitus (DM) by extracting the model parameters from 42 people with DM and comparing these parameters with those of 42 healthy participants. The parameter in the first-order term of the elastic force of the participants with DM was significantly lower than that of the healthy participants (p < 0.05). The sympathetic force and sympathetic action delay of the participants with DM were significantly larger (p < 0.05) and longer (p < 0.0001) than that of the healthy ones, respectively. The reason might be that the sympathetic nervous system, which controls the dilator muscle, degenerated in diabetic patients.
- 25 June 2021
- Published by MDPI AG in Brain Sciences
- Vol. 11  (7) , 852
Open AccessUsing System Identification to Construct an Inherent Model of Pupillary Light Reflex to Explore Diabetic Neuropathy
This study proposed a pupillary light reflex (PLR) inherent model based on the system identification method to demonstrate the dynamic physiological mechanism of the PLR, in which pupillary constriction and dilation are controlled by the sympathetic and parasympathetic nervous system. This model was constructed and verified by comparing the simulated and predicted PLR response with that of healthy participants. The least root-mean-square error (RMSE) of simulated PLR response was less than 0.7% when stimulus duration was under 3 ms. The RMSE of predicted PLR response increased by approximately 6.76%/s from the stimulus duration of 1 ms to 3 s, when the model directly used the parameters extracted from the PLR at the stimulus duration of 10 ms. When model parameters were derived from the regression by the measured PLR response, the RMSE kept under 8.5%. The model was applied to explore the PLR abnormalities of the people with Diabetic Mellitus (DM) by extracting the model parameters from 42 people with DM and comparing these parameters with those of 42 healthy participants. The parameter in the first-order term of the elastic force of the participants with DM was significantly lower than that of the healthy participants (p < 0.05). The sympathetic force and sympathetic action delay of the participants with DM were significantly larger (p < 0.05) and longer (p < 0.0001) than that of the healthy ones, respectively. The reason might be that the sympathetic nervous system, which controls the dilator muscle, degenerated in diabetic patients.
- Open Access
- 22 June 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9  (7) , 74
Autofluorescence Detection Method for Dental Plaque Bacteria Detection and Classification: Example of Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans
The use of fluorescence spectroscopy for plaque detection is a fast and effective way to monitor oral health. At present, there is no uniform specification for the design of the excitation light source of related products for generating fluorescence. To carry out experiments on dental plaque, the fluorescence spectra of three different bacterial species (Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans) were measured by hyperspectral imaging microscopy (HIM). Three critical issues were found in the experiments. One issue was the unwanted spectrum generated from a mercury line source; two four-order low-pass filters were evaluated for eliminating the unwanted spectrum and meet the experimental requirements. The second issue was the red fluorescence generated from the microscope slide made of borosilicate glass; this could affect the observation of the red fluorescence from the bacteria; quartz microscope slides were found to reduce the fluorescence intensity by about 2 dB compared with the borosilicate slide. The third issue of photobleaching in the fluorescence of the Porphyromonas gingivalis was studied. This study proposes a method of classifying three bacteria based on the spectral intensity ratios (510/635 and 500/635 nm) under the 405 nm excitation light was proposed in this study. The sensitivity and specificity of the classification were approximately 99% and 99%, respectively.
- 22 June 2021
- Published by MDPI AG in Dentistry Journal
- Vol. 9  (7) , 74
Open AccessAutofluorescence Detection Method for Dental Plaque Bacteria Detection and Classification: Example of Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans
The use of fluorescence spectroscopy for plaque detection is a fast and effective way to monitor oral health. At present, there is no uniform specification for the design of the excitation light source of related products for generating fluorescence. To carry out experiments on dental plaque, the fluorescence spectra of three different bacterial species (Porphyromonas gingivalis, Aggregatibacter actinomycetemcomitans, and Streptococcus mutans) were measured by hyperspectral imaging microscopy (HIM). Three critical issues were found in the experiments. One issue was the unwanted spectrum generated from a mercury line source; two four-order low-pass filters were evaluated for eliminating the unwanted spectrum and meet the experimental requirements. The second issue was the red fluorescence generated from the microscope slide made of borosilicate glass; this could affect the observation of the red fluorescence from the bacteria; quartz microscope slides were found to reduce the fluorescence intensity by about 2 dB compared with the borosilicate slide. The third issue of photobleaching in the fluorescence of the Porphyromonas gingivalis was studied. This study proposes a method of classifying three bacteria based on the spectral intensity ratios (510/635 and 500/635 nm) under the 405 nm excitation light was proposed in this study. The sensitivity and specificity of the classification were approximately 99% and 99%, respectively.
- Open Access
Band-Selection of a Portal LED-Induced Autofluorescence Multispectral Imager to Improve Oral Cancer Detection
This aim of this study was to find effective spectral bands for the early detection of oral cancer. The spectral images in different bands were acquired using a self-made portable light-emitting diode (LED)-induced autofluorescence multispectral imager equipped with 365 and 405 nm excitation LEDs, emission filters with center wavelengths of 470, 505, 525, 532, 550, 595, 632, 635, and 695 nm, and a color image sensor. The spectral images of 218 healthy points in 62 healthy participants and 218 tumor points in 62 patients were collected in the ex vivo trials at China Medical University Hospital. These ex vivo trials were similar to in vivo because the spectral images of anatomical specimens were immediately acquired after the on-site tumor resection. The spectral images associated with red, blue, and green filters correlated with and without nine emission filters were quantized by four computing method, including summated intensity, the highest number of the intensity level, entropy, and fractional dimension. The combination of four computing methods, two excitation light sources with two intensities, and 30 spectral bands in three experiments formed 264 classifiers. The quantized data in each classifier was divided into two groups: one was the training group optimizing the threshold of the quantized data, and the other was validating group tested under this optimized threshold. The sensitivity, specificity, and accuracy of each classifier were derived from these tests. To identify the influential spectral bands based on the area under the region and the testing results, a single-layer network learning process was used. This was compared to conventional rules-based approaches to show its superior and faster performance. Consequently, four emission filters with the center wavelengths of 470, 505, 532, and 550 nm were selected by an AI-based method and verified using a rule-based approach. The sensitivities of six classifiers using these emission filters were more significant than 90%. The average sensitivity of these was about 96.15%, the average specificity was approximately 69.55%, and the average accuracy was about 82.85%.
Open AccessBand-Selection of a Portal LED-Induced Autofluorescence Multispectral Imager to Improve Oral Cancer Detection
This aim of this study was to find effective spectral bands for the early detection of oral cancer. The spectral images in different bands were acquired using a self-made portable light-emitting diode (LED)-induced autofluorescence multispectral imager equipped with 365 and 405 nm excitation LEDs, emission filters with center wavelengths of 470, 505, 525, 532, 550, 595, 632, 635, and 695 nm, and a color image sensor. The spectral images of 218 healthy points in 62 healthy participants and 218 tumor points in 62 patients were collected in the ex vivo trials at China Medical University Hospital. These ex vivo trials were similar to in vivo because the spectral images of anatomical specimens were immediately acquired after the on-site tumor resection. The spectral images associated with red, blue, and green filters correlated with and without nine emission filters were quantized by four computing method, including summated intensity, the highest number of the intensity level, entropy, and fractional dimension. The combination of four computing methods, two excitation light sources with two intensities, and 30 spectral bands in three experiments formed 264 classifiers. The quantized data in each classifier was divided into two groups: one was the training group optimizing the threshold of the quantized data, and the other was validating group tested under this optimized threshold. The sensitivity, specificity, and accuracy of each classifier were derived from these tests. To identify the influential spectral bands based on the area under the region and the testing results, a single-layer network learning process was used. This was compared to conventional rules-based approaches to show its superior and faster performance. Consequently, four emission filters with the center wavelengths of 470, 505, 532, and 550 nm were selected by an AI-based method and verified using a rule-based approach. The sensitivities of six classifiers using these emission filters were more significant than 90%. The average sensitivity of these was about 96.15%, the average specificity was approximately 69.55%, and the average accuracy was about 82.85%.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92  (1) , 014101
Quantitative examination of early diabetes by light-emitting diodes light-induced pupillary light reflex
This study investigated the abnormal pupillary light reflex in patients with early diabetes mellitus (DM) without retinopathy by using a custom-made noninvasive portable pupilometer. The pupilometer recorded and analyzed the pupillary light reflex. Two light intensities, 0.2 cd and 1.2 cd, and four wavelengths of stimulus light—white (400 nm–800 nm), red (640 ± 5 nm), green (534 ± 5 nm), and blue (470 ± 5 nm)—were used to stimulate the pupil for 10 ms. The pupillary response was recorded for 15 s. A total of 40 healthy people and 40 people with DM without retinopathy participated in the experiment at the National Taiwan University Hospital. The mean and standard deviation of DM duration were 4.5 years and 3.9 years. Of the 16 indices, the duration that pupil restores from its minimum size to half of its resting size (DRP), maximum pupil restoration velocity (MRV), and average restoration velocity (ARV) exhibited the most significant differences between the healthy people and those with DM. Compared with healthy participants, DRP was 16.33% higher, and MRV and ARV were 17.45% and 4.58% lower, respectively, in those with DM. This might be attributable to the sympathetic nervous system (SNS) controlling the dilator muscle during the dark-adapted period and relaxing the pupil; the SNS had few degenerated nerve endings in people with DM. The three aforementioned indices might be used to evaluate the severity of autonomic neuropathy in early DM.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92  (1) , 014101
Quantitative examination of early diabetes by light-emitting diodes light-induced pupillary light reflex
This study investigated the abnormal pupillary light reflex in patients with early diabetes mellitus (DM) without retinopathy by using a custom-made noninvasive portable pupilometer. The pupilometer recorded and analyzed the pupillary light reflex. Two light intensities, 0.2 cd and 1.2 cd, and four wavelengths of stimulus light—white (400 nm–800 nm), red (640 ± 5 nm), green (534 ± 5 nm), and blue (470 ± 5 nm)—were used to stimulate the pupil for 10 ms. The pupillary response was recorded for 15 s. A total of 40 healthy people and 40 people with DM without retinopathy participated in the experiment at the National Taiwan University Hospital. The mean and standard deviation of DM duration were 4.5 years and 3.9 years. Of the 16 indices, the duration that pupil restores from its minimum size to half of its resting size (DRP), maximum pupil restoration velocity (MRV), and average restoration velocity (ARV) exhibited the most significant differences between the healthy people and those with DM. Compared with healthy participants, DRP was 16.33% higher, and MRV and ARV were 17.45% and 4.58% lower, respectively, in those with DM. This might be attributable to the sympathetic nervous system (SNS) controlling the dilator muscle during the dark-adapted period and relaxing the pupil; the SNS had few degenerated nerve endings in people with DM. The three aforementioned indices might be used to evaluate the severity of autonomic neuropathy in early DM.