Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael Christ has a total of 328 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cardiac Myosin‐Binding Protein C for Diagnosis of Myocardial Infarction in Patients With Prior Coronary Artery Bypass Grafting

    by Rebekka Odermatt, Luca Koechlin, Pedro Lopez‐Ayala, Emel Kaplan, Lourdes Herraiz Recuenco, Gabrielle Huré, Paolo Bima, Luca Crisanti, Karin Wildi, Òscar Miró, et al.

    Background: Diagnosing myocardial infarction in patients with prior coronary artery bypass grafting (CABG) remains challenging, primarily because of lower diagnostic accuracy of high‐sensitivity cardiac troponin (hs‐cTn). cMyC (cardiac myosin‐binding protein C), because of its faster release kinetics and greater abundance, may offer improved diagnostic performance in this population. Methods: The diagnostic accuracy of cMyC was directly compared with that of hs‐cTnT and hs‐cTnI in a prospective, international, multicenter, diagnostic study enrolling adult patients presenting to the emergency department with acute chest discomfort. Final diagnoses were centrally adjudicated by 2 independent cardiologists using all available clinical and study‐specific data, including imaging and serial hs‐cTnT measurements. Patients were stratified according to the presence or absence of prior CABG. Results: Among 4752 patients, 387 (8%) had prior CABG (median age, 75 years; 86% men). The incidence of myocardial infarction was significantly higher in patients with prior CABG (38% versus 16%; P <0.001). In the CABG group, the diagnostic accuracy of cMyC as quantified by the area under the curve was 0.88 (95% CI, 0.85–0.92), which was comparable but not superior to that of hs‐cTnT (0.89 [95% CI, 0.86–0.92]) and hs‐cTnI (0.88 [95% CI, 0.84–0.91]). These findings were consistent across alternative high‐sensitivity cMyC assays. Conclusions: In patients with prior CABG, cMyC demonstrated high diagnostic accuracy for myocardial infarction, but not superior to established hs‐cTnT and hs‐cTnI assays. Registration: URL: clinicaltrials.gov ; Unique Identifier: NCT00470587.

  • Open Access

    International Delphi on a medical screening tool for emergency department patients with psychiatric complaints

    by Luca Ünlü, Christopher R. Carpenter, Philipp Sterzer, Michael Christ, Navid Azad, Johannes A. Griese, Kimberly Nordstrom, Clare Skinner, Jelmer Alsma, Victor Stiebel, et al.

    Background: Medical screening in the emergency department (ED) is performed to identify underlying medical conditions that may contribute to a patient’s psychiatric presentation and/or require treatment. This process frequently causes disagreement between emergency physicians and psychiatrists regarding objectives and scope of medical screening, leading to potentially unnecessary testing, prolonged ED length-of-stay, and increased costs. This study aims to develop an evidence-informed and consensus-based medical screening tool through a transdisciplinary, international Delphi process. Methods: This modified international Delphi study was conducted between May and November 2025 using a 4-round modified Delphi process with online surveys and online steering committee discussions. Participants included 25 society representatives from 7 emergency medicine and psychiatry societies across 4 continents and 6 patient representatives with prior ED medical screening experience as patients or patient relatives. Participants generated, rated, refined, and reached consensus on proposed screening elements. Consensus was predefined as ≥80% agreement in Round 3. In Round 4, the resulting tool was applied to 37 standardized clinical vignettes. Interrater agreement was assessed using Gwet agreement coefficient (AC). Results: Of 28 invited society representatives and steering committee members, 25 (89.3%) participated in Round 1, 23 (82.1%) in Round 2, 22 (78.6%) in Round 3, and 23 (82.1%) in Round 4. The 6 patient representatives completed all 4 rounds. In Round 1, participants generated 91 statements from society representatives and 27 from patient representatives. Following refinement in Round 2, consensus in Round 3 was achieved for 48 of 91 society representatives’ statements (52.8%) and 21 of 27 patient statements (77.8%), which were synthesized into the Delphi-Informed Medical Evaluation (DIME) tool. In Round 4, application of the draft DIME tool to 37 clinical vignettes demonstrated almost perfect agreement among society representatives (Gwet AC, 0.86; 95%-CI 0.78–0.93; p < .001) and substantial agreement among patient representatives (Gwet AC, 0.76; 95%-CI 0.66–0.86; p < .001). Conclusions: This international modified Delphi study developed the DIME tool, a consensus-based medical screening tool to identify adult ED patients with psychiatric complaints who are at low risk for acute medical illness. Prospective multicenter validation studies are required before clinical implementation. Trial registration: clinicaltrials.gov, NCT06936826

  • Open Access

    Training and validation of a 12-lead ECG-based deep-learning model for myocardial infarction subtypes

    by Tobias Zimmermann, Ivo Strebel, Pedro Lopez-Ayala, Wayne Zeng, Sven Knecht, Lea Kirsten, Luca Koechlin, Kunalish Kulendra, Emel Kaplan, Tiffany Pequignot, et al.

    A convolutional neural network was developed to detect acute myocardial infarction (AMI) subtypes from digital 12-lead ECGs. Trained on 173,396 hospitalized patients’ ECGs, the model underwent fine-tuning and internal validation in 7591 patients and external validation in 4370 patients with suspected AMI. Both prospective validation studies employed central diagnostic adjudication. For non-ST-segment elevation MI (NSTEMI), the model achieved an area under the receiver operating characteristic curve (AUROC) of 0.81 [95%-confidence interval (CI) 0.79–0.83], with NSTEMI type 1 at 0.82 [0.80–0.84] versus type 2 at 0.75 [0.71–0.79]. Performance was superior in younger patients without prior heart disease. For ST-segment elevation MI (STEMI), the model outperformed physician interpretation (AUROC 0.96 [95%-CI 0.94–0.98] vs. 0.89 [0.85–0.93], p < 0.001). Occlusion MI detection reached AUROC 0.91 [95%-CI 0.89–0.93], though NSTEMI-OMI cases were frequently missed. Overall calibration was good for all MI subtypes. This ECG-based deep learning model demonstrates good discrimination and calibration across AMI subtypes, indicating potential clinical utility for rapid risk stratification and early cardiology intervention.


  • Open Access

    Direct Comparison of the 0/1h‐ and 0/2h‐Algorithms in Patients With Prior Coronary Artery Bypass Grafting

    by Luca Koechlin, Jasper Boeddinghaus, Pedro Lopez‐Ayala, Gordon Jacobsen, James McCord, Bent Heimbach, Thomas Nestelberger, Karin Wildi, Emel Kaplan, Danielle M. Gualandro, et al.

    Background: The European Society of Cardiology (ESC) 0/1h‐high‐sensitivity cardiac troponin (hs‐cTn)T/I‐algorithms have lower efficacy in patients with prior coronary artery bypass grafting. We hypothesized that in these high‐risk patients, the longer time to the second blood draw within the ESC 0/2h‐hs‐cTn‐algorithms would increase efficacy, defined as the proportion of patients triaged to rule‐in/out of myocardial infarction, versus the ESC‐0/1h‐hs‐cTn‐algorithms. Methods: In a prospective international multicenter diagnostic study including patients presenting to the emergency department with acute chest discomfort, final diagnoses were centrally adjudicated according to the Universal Definition of Myocardial Infarction. Safety and efficacy of the guideline‐recommended ESC 0/1h‐ and 0/2h‐hs‐cTn‐algorithms using assay‐specific use‐optimized cut‐offs were directly compared in patients with prior coronary artery bypass grafting. Findings were externally validated in an independent prospective US multicenter study. Results: Among 356 patients (median [interquartile range] age 73 [64–80] years, prevalence of non–ST‐segment–elevation myocardial infarction [NSTEMI]: 31% [n=112]), sensitivity for rule‐out of NSTEMI was high for the ESC 0/1h‐ and 0/2h‐hs‐cTnT‐Elecsys‐algorithms (0/1h: 100% [95% CI 96.7–100]; 0/2h: Sensitivity: 99.1% [95% CI 95.1–99.8]). Specificity for rule‐in of NSTEMI was also high (0/1h: 97.1% [95% CI 94.2–98.6]; 0/2h 98.4% [95% CI 95.9–99.4]). Efficacy was 50.6% for 0/1h and 58.4% for 0/2h (difference: 7.9% [95% CI 4.2–11.5]). Findings with higher efficacy for 0/2h versus 0/1h were confirmed using hs‐cTnI‐Architect (difference in efficacy 3.1% [95% CI 0.1–6.1]) and using hs‐cTnI‐Atellica in the external validation cohort (n=178; difference in efficacy 9% [95% CI 4.5–13.5]). Conclusions: The ESC 0/2h‐hs‐cTn‐algorithms have higher efficacy and comparable safety versus the ESC 0/1h‐hs‐cTn‐algorithms in patients with prior coronary artery bypass grafting. Registration: URL: https://www.clinicaltrials.gov ; Unique Identifier: NCT00470587.


  • Open Access

    Alternative Rule‐Out Cutoffs for a Novel High‐Sensitivity Cardiac Troponin I Assay in Patients With Suspected Myocardial Infarction

    by Koray Durak, Pedro Lopez-Ayala, Luca Koechlin, Jasper Boeddinghaus, Federico De Vita, Emel Kaplan, Lourdes Herraiz-Recuenco, Òscar Miró, Michael Christ, Dagmar I Keller, et al.

    Background: There is major uncertainty among physicians on how to best use the novel hs‐cTnI (high sensitivity‐cardiac troponin I)‐VITROS assay, as the limit of quantification (2 ng/L), applied by the US Food and Drug Administration and other regulators, is higher than the limit of detection (1 ng/L)‐based rule‐out cutoffs from recent pilot studies for 0/1‐hour and 0/2‐hour algorithms. Methods: This prospective, multicenter study aimed to derive and validate higher limit of quantification‐based assay‐specific cutoffs for safe and efficient rule‐out of myocardial infarction among adult patients presenting with acute chest discomfort to the emergency department. Final diagnoses of myocardial infarction were centrally adjudicated by 2 independent cardiologists, blinded to hs‐cTnI‐VITROS concentrations. Results: Among 2931 eligible patients, 467 (16%) were diagnosed with myocardial infarction. In the derivation cohort (n=1466), a cutoff ≤2 ng/L at presentation in patients with chest pain onset >3 hours (direct rule‐out) and ≤2 ng/L in combination with a 1‐hour absolute change of ≤1 ng/L ruled out 51% of patients, with a sensitivity of 99.1% (96.9%–99.8%). Predefined rule‐in thresholds (0 hour‐value ≥40 ng/L [direct rule‐in] or an absolute change within 1 hour of ≥4 ng/L) identified 16.9% of patients, with a specificity of 95.9% (94.7%–96.9%). Very high sensitivity and specificity were confirmed in the validation cohort (n=1465). Comparable findings were observed for the alternative 0/2‐hour algorithm with ≤2 ng/L as the rule‐out threshold. Conclusions: The alternative 0/1‐hour and 0/2‐hour algorithms using limit of quantification‐based rule‐out cutoffs of ≤2 ng/L with the hs‐cTnI‐VITROS assay demonstrated very high safety and efficacy in suspected myocardial infarction. Registration: URL: https://www.clinicaltrials.gov/ ; Identifier: NCT00470587.

  • Open Access

    Validation of the ESC 0/3h-Algorithm with a Novel High-Sensitivity Cardiac Troponin I Assay in Patients with Suspected Myocardial Infarction

    by Koray Durak, Pedro Lopez-Ayala, Luca Koechlin, Jasper Boeddinghaus, Ivo Strebel, Sebastian Messingschlager, Arnaud Champetier, Emel Kaplan, Lourdes Herraiz-Recuenco, Òscar Miró, et al.

    Background: There is uncertainty among physicians regarding the optimal clinical application of the novel high-sensitivity cardiac troponin I (hs-cTnI)-VITROS assay within the widely implemented upper reference limit (URL)-based ESC 0/3h-algorithm. Methods: This prospective, international, multicenter study aimed to validate and compare different modifications of the URL-based ESC 0/3h-algorithm among adult patients presenting with suspected acute myocardial infarction (AMI) to the emergency department. Final diagnoses of AMI were centrally adjudicated by two independent cardiologists, blinded to hs-cTnI-VITROS concentrations. Discrimination was compared to the best validated hs-cTnT/I-assays. Clinical follow-up for cardiovascular death and AMI was conducted until five years. Results: Among 1225 eligible patients (median age 63 years (IQR 52-75), 31.9% women), 18.9% were adjudicated as NSTEMI. Diagnostic discrimination of hs-cTnI-VITROS at 0h was very high (AUC 0.949, 95% CI 0.941–0.958), and comparable to hs-cTnI-Architect and hs-cTnT-Elecsys. Using the ESC 0/3h algorithm, 30.9% of patients were classified as rule-out (sensitivity 99.1%, NPV 99.5%) and 19.0% as rule-in (specificity 96.0%, PPV 82.8%). Substituting the HEART score for the GRACE score increased rule-out efficacy to 43.9%, while maintaining very high safety (sensitivity 99.6%; NPV 99.8%). Findings were consistent across predefined subgroups, in sensitivity analyses restricted to type 1 NSTEMI, using the 2h study blood sample (n=2249), and for the composite of cardiovascular death or AMI during five-year follow-up. Conclusions: The ESC 0/3h-algorithm demonstrated excellent performance for rule-out of NSTEMI with greater efficacy when combined with the HEART-instead of the GRACE score. Registration: https://clinicaltrials.gov/study/NCT00470587 Clinical Perspective: What Is New?: In a prospective, international multicenter cohort, the URL-based ESC 0/3h algorithm using the FDA-cleared hs-cTnI-VITROS assay achieved very high rule-out safety (sensitivity 99.1%, NPV 99.5%) but limited efficacy (30.9% rule-out) when combined with GRACE score <140 and symptom resolution. Replacing GRACE with a HEART score (<5) increased rule-out efficacy to 43.9% while maintaining excellent safety (sensitivity 99.6%, NPV 99.8%), with consistent findings across subgroups, sensitivity analyses, and long-term outcomes. What Are the Clinical Implications?: Clinicians and health systems using hs-cTnI-VITROS can apply the ESC 0/3h algorithm with assay-conform decision values; adding clinical risk stratification is necessary to meet contemporary rule-out safety targets.

  • Acute hyperkalaemia in emergency care: evidence-based approaches

    by Niclas Geldermann, Julia Dzimiera, Henning Fischer, Michael Christ

    Acute hyperkalaemia is a potentially life-threatening electrolyte disturbance frequently encountered in emergency departments. Timely recognition and appropriate treatment are critical to prevent serious complications such as cardiac arrhythmias and death. This narrative review summarises current evidence-based and guideline-based recommendations for the emergency management of hyperkalaemia, with a focus on practical challenges and frequently encountered clinical uncertainties. A selective literature search was conducted using PubMed, EMBASE and major international guidelines, emphasising clinical studies performed in emergency departments or acute care settings. Key treatment principles include therapy with intravenous calcium salts, primarily indicated in patients with ECG changes or serum potassium levels ≥6.5 mmol/L. Insulin-glucose therapy remains a cornerstone of transcellular potassium shifting but carries a considerable risk of subsequent hypoglycaemia, particularly in non-diabetic patients with low baseline glucose levels. Inhaled beta-agonists such as salbutamol provide an effective and synergistic potassium-lowering effect and are recommended in combination with insulin. The use of sodium bicarbonate remains uncertain and its indication appears limited to patients with severe comorbid conditions and metabolic acidosis. Diuretics may support potassium elimination in patients with volume overload, although prospective evidence in ED populations is lacking. Sodium polystyrene sulfonate is no longer recommended due to questionable efficacy and risk of gastrointestinal adverse events. Newer potassium binders, including sodium zirconium cyclosilicate and patiromer, show promise in recent studies but require further validation in acute care settings. Haemodialysis remains the definitive option in refractory cases or patients with end-stage renal disease.


  • Als Teamplayer Zukunft gestalten

    by Bruno Minotti, Olivia Kotoun, Torsten Weirauch, Michael Christ, Vorstand der Semsa

  • Open Access

    Notfallsonographie: Wissen anwenden, um Leben zu retten

    by Michael Christ, Dorothea Sauer

  • Open Access

    Point-of-Care Ultrasound reduces Emergency Department Length of Stay in Patients with Acute Appendicitis

    by Mirjam Schäfer, Luca Schuler, Florian Wuethrich, Christ Michael, Stefan Venturini

    Background: Acute appendicitis (AA) is a common surgical emergency where timely diagnosis is eminent. Point-of-care ultrasound (POCUS) offers a fast, bedside imaging option that may reduce emergency department (ED) length of stay (LOS), though the diagnostic accuracy is highly examiner-dependent. This study evaluated the effect of POCUS performed by emergency physicians on ED LOS in patients with suspected AA at a tertiary hospital in Lucerne, Switzerland. Methods: We conducted a retrospective monocentric study including patients who presented to the ED in 2022–2023 and subsequently underwent an appendectomy for AA. Patients were divided into four subgroups based on imaging modality and examiner. Results: 252 patients met the inclusion criteria. Group distributions were as follows: Group 1 (US by ED): 107; Group 2 (US by ED + radiology or only by radiology): 59; Group 3 (US + CT): 60; Group 4 (CT only): 26. A statistically significant difference in LOS was observed among groups, particularly favouring POCUS by ED physicians (p < 0.001). In group 3, CT was performed to confirm strong US suspicion (41.7%), non-visualisation (40%), inconclusive findings (15%), or other differentials (3.3%); among cases with strong US suspicion, perforation was queried in 60%. Ultrasound experience, reflected by the weighted average, increased over time, accompanied by a rise in US-only diagnoses in the ED. Multivariable linear regression identified younger age, lower BMI, and lower CRP as significant predictors of diagnosis based on ultrasound alone (p < 0.001), R² = 0.373. Conclusions: Patients with AA diagnosed by emergency physician-performed POCUS had a significantly shorter ED LOS. Increasing ultrasound competency among emergency physicians was paralleled by a proportional increase in cases diagnosed exclusively by US in the ED. The likelihood of requiring CT imaging increased with higher patient age, BMI and CRP.