HYHiroyuki Yamamoto

Hiroyuki Yamamoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hiroyuki Yamamoto has a total of 107 co-authors. Here are the top co-authors by number of shared publications:

  • Tomofumi Takaya

    Division of Cardiovascular Medicine, Hyogo Prefectural Harima-Himeji General Medical Center , 3-264 Kamiya-cho, Himeji 670-8560

    35 shared publications
  • Hiroya Kawai

    Division of Cardiovascular Medicine, Department of Exploratory and Advanced Search in Cardiology (T.T., H.K.), Kobe University Graduate School of Medicine, Japan

    19 shared publications
  • Tomofumi Takaya

    Division of Cardiovascular Medicine, Hyogo Prefectural Harima-Himeji General Medical Center

    18 shared publications
  • Nobuyuki Takahashi

    Division of Cardiovascular Medicine, Hyogo Prefectural Harima-Himeji General Medical Center

    13 shared publications
  • Takahiro Sawada

    Department of Cardiology, Kakogawa Central City Hospital, Kakogawa, Japan

    8 shared publications
  • Akiko Masumoto

    Division of Cardiovascular Medicine, Hyogo Prefectural Harima-Himeji General Medical Center

    7 shared publications

Latest Publications

  • Open Access

    “Locked-in Technique” Following Balloon Pullback to Reposition a Migrated Thrombus in a Coronary Aneurysm

    by Yuki Hayashi, Hiroyuki Yamamoto, Koki Matsuo, Tomofumi Takaya

    Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.

  • Open Access

    Clinical Outcomes of Drug-Coated Balloon Following Directional Coronary Atherectomy in Acute vs Chronic Coronary Syndrome

    by Masayoshi Fujii, Hiroyuki Yamamoto, Takahiro Sawada, Yoshinori Yasaka, Kenzo Uzu, Taishi Miyata, Tomohiro Inoue, Tomofumi Takaya

  • Open Access

    Long-Term Efficacy of Drug-Coated Balloon Angioplasty vs. Drug-Eluting Stent for De Novo Large-Vessel Coronary Arteries

    by Mayuka Masuda, Hiroyuki Yamamoto, Shinsuke Nakano, Nobuyuki Takahashi, Taishi Miyata, Tomohiro Inoue, Tomofumi Takaya

    Background: Drug-coated balloon (DCB) angioplasty has shown short-term feasibility for large-vessel coronary artery disease (CAD; ≥3 mm); however, long-term outcomes remain unclear. This study aimed to evaluate the 5-year cardiovascular outcomes of DCB angioplasty vs. drug-eluting stents (DES) for de novo large-vessel CAD.Methods and Results: This single-center retrospective study analyzed patients undergoing percutaneous coronary intervention (PCI) with either DCB (SeQuent Please) or DES (Xience Alpine) between January 2016 and December 2018. The primary outcomes were cardiovascular events (CVE), defined as a composite of cardiac death, non-fatal myocardial infarction, and target lesion revascularization (TLR). Secondary outcomes included minimal lumen diameter (MLD), diameter stenosis (DS), and late lumen loss (LLL), assessed at the index PCI and at the 1-year angiographic follow up. Overall, 114 patients (122 lesions) in the DCB group and 269 patients (293 lesions) in the DES group were analyzed, with similar median follow-up durations (1,678 vs. 1,825 days; P=0.687). At 5 years, TLR and CVE rates were comparable between the DCB and DES groups (7.9% vs. 4.5%, P=0.239; and 11.4% vs. 10.4%, P=0.773, respectively). No significant differences in MLD, DS, or LLL were observed between the groups at the 1-year follow up.Conclusions: With careful lesion selection and preparation, DCB angioplasty could serve as a feasible treatment option for de novo large-vessel CAD in clinical practice.


  • Open Access

    Bailout Balloon Aortic Valvuloplasty for Hemodynamic Collapse during Mitral Transcatheter Edge-to-Edge Repair in a Patient with Combined Valvular Disease

    by Yuki Hayashi, Akiko Masumoto, Hiroyuki Yamamoto, Nobuyuki Takahashi, Tetsuari Onishi, Tomofumi Takaya

    Objective: The coexistence of degenerative mitral regurgitation (DMR) and paradoxical low-flow, low-gradient aortic stenosis (LFLG AS) presents significant therapeutic challenges in high-risk elderly patients. Treatment sequencing is particularly controversial when both lesions are severe and hemodynamically interactive.Case Presentation: An 88-year-old frail man with severe DMR (P3 prolapse) and paradoxical LFLG severe AS presented with decompensated heart failure. Due to high surgical risk and limited vascular access, we opted for mitral transcatheter edge-to-edge repair (M-TEER) first. During deployment of the first clip, acute worsening of mitral regurgitation (MR) occurred due to interference with the leaflets, leading to hypotension. To stabilize the hemodynamics and enable safe completion of M-TEER, emergent balloon aortic valvuloplasty (BAV) with an Inoue balloon (22 mm) was performed, resulting in hemodynamic stability. Finally, mitral regurgitation was effectively controlled with 2 clips, and the patient was discharged with New York Heart Association (NYHA) class I status.Conclusion: This case highlights the utility of intra-procedural BAV as a rescue strategy during M-TEER. In such cases, careful imaging assessment, hemodynamic monitoring, and understanding of bailout strategies are important when M-TEER is selected as the initial treatment.

  • Open Access

    Refractory Heart Failure With Reversible Left Ventricular Dysfunction and Mitral Regurgitation in Takayasu Arteritis

    by Yusuke Hirao, Akiko Masumoto, Hiroyuki Yamamoto, Tomofumi Takaya

    Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.

  • Open Access

    Balloon-expandable transcatheter heart valve deformation: a rare complication during transcatheter aortic valve replacement

    by Akiko Masumoto, Hiroyuki Yamamoto, Nobuyuki Takahashi, Tomofumi Takaya

    An 80-year-old woman with a history of pacemaker implantation and reduced left ventricular function (left ventricular ejection fraction: 33%) presented with severe aortic stenosis. Computed tomography (CT) revealed stenoses of the bilateral iliac arteries and calcified abdominal aorta (Figure 1A and B). However, neither trans-subclavian nor direct aortic transcatheter aortic valve replacement (TAVR) was feasible due to subclavian artery stenosis and a porcelain ascending aorta. Moreover, the surgical risks were high, with a mortality risk for surgical aortic valve replacement, as measured by the Society of Thoracic Surgeons score, being 11.8%. After discussing the choice of valve system within the heart team, transfemoral TAVR with a balloon-expandable valve (BEV) was performed. This decision was made considering that 14 Fr eSheaths of the balloon-expandable systems would be suitable to pass through calcified or tortuous femoral arteries, compared to 14 Fr equivalent in-line sheaths of self-expandable systems. Intravascular lithotripsy was not available at the time of the procedure. Upon reaching the descending thoracic aorta with the delivery system, an outward bending of the transcatheter heart valve (THV) stent frame was observed, encountering slight resistance (Figure 1C). Moreover, balloon angioplasty using a 7 mm balloon aligned next to the THV failed to fix the deformation (Figure 1D). The delivery system could not be retracted into the sheath. In this case, retracting the THV system as a whole posed risks of further damaging heavily calcified arteries. Additionally, the heart team cautiously decided to proceed with deploying the valve while preparing surgical backup in case of rupture. The valve was advanced while protecting the deformed part with a balloon to prevent friction against the aortic intima: ‘balloon cushion technique’. The deformed part was directed towards the non-coronary cusp (NCC) in the ‘NCC isolation view’ on fluoroscopy, minimizing the risk of annular rupture (Figure 1E). The BEV was deployed with slow inflation and an underfilling of 3 mL, resulting in no signs of annular rupture or ventricular septal ruptures (Figure 1F; Supplementary material online , Video S1). Localized dissection was observed in the abdominal aorta, which was treated with endovascular stent grafts (Figure 1G). Subsequently, post-procedural CT confirmed no annular rupture (Figure 1H).

  • Single-Cell RNA Sequencing Reveals an Immune Landscape of CD4+ T Cells in Coronary Culprit Plaques With Acute Coronary Syndrome in Humans—Brief Report

    by Shintaro Takeda, Takuo Emoto, Tomoya Yamashita, Hiroyuki Yamamoto, Tomofumi Takaya, Takahiro Sawada, Takeshi Yoshida, Masatoshi Inoue, Yuya Suzuki, Tomoyo Hamana, et al.

    BACKGROUND: Acute coronary syndrome (ACS) involves plaque-related thrombosis, causing primary ischemic cardiomyopathy or lethal arrhythmia. We previously demonstrated a unique immune landscape of myeloid cells in the culprit plaques causing ACS by using single-cell RNA sequencing. Here, we aimed to characterize T cells in a single-cell level, assess clonal expansion of T cells, and find a therapeutic target to prevent ACS. METHODS: We obtained the culprit lesion plaques from 4 patients with chronic coronary syndrome (chronic coronary syndrome plaques) and the culprit lesion plaques from 3 patients with ACS (ACS plaques) who were candidates for percutaneous coronary intervention with directional coronary atherectomy. Live CD45+ immune cells were sorted from each pooled plaque samples and applied to the 10× platform for single-cell RNA sequencing analysis. We also extracted RNA from other 3 ACS plaque samples and conducted unbiased TCR (T-cell receptor) repertoire analysis. RESULTS: CD4+ T cells were divided into 5 distinct clusters: effector, naive, cytotoxic, CCR7+ (C-C chemokine receptor type 7) central memory, and FOXP3 (forkhead box P3)+ regulatory CD4+ T cells. The proportion of central memory CD4+ T cells was higher in the ACS plaques. Correspondingly, dendritic cells also tended to express more HLAs (human leukocyte antigens) and costimulatory molecules in the ACS plaques. The velocity analysis suggested the differentiation flow from central memory CD4+ T cells into effector CD4+ T cells and that from naive CD4+ T cells into central memory CD4+ T cells in the ACS plaques, which were not observed in the chronic coronary syndrome plaques. The bulk repertoire analysis revealed clonal expansion of TCRs in each patient with ACS and suggested that several peptides in the ACS plaques work as antigens and induced clonal expansion of CD4+ T cells. CONCLUSIONS: For the first time, we revealed single cell–level characteristics of CD4+ T cells in patients with ACS. CD4+ T cells could be therapeutic targets of ACS. REGISTRATION: URL: https://upload.umin.ac.jp/cgi-open-bin/icdr_e/ctr_view.cgi?recptno=R000046521; Unique identifier: UMIN000040747.


  • Open Access

    Entrapment of the Impella device by the guiding catheter: a cautionary pitfall of Impella-protected percutaneous coronary intervention

    by Hiroyuki Yamamoto, Nobuhiro Watanabe, Koki Matsuo, Tomofumi Takaya

    A 67-year-old man presented with acute decompensated heart failure and cardiogenic shock. Transthoracic echocardiography revealed severe global left ventricular hypokinesis with a left ventricular ejection fraction of 25%. Emergency coronary angiography revealed multiple stenoses without obstruction. Therefore, transfemoral left ventricular assist (Impella CP, Abiomed, USA) support was performed to increase coronary flow through diastolic augmentation. However, low cardiac output syndrome made removing the Impella device difficult, requiring percutaneous coronary revascularization. Although a backup guiding catheter (GC; Hyperion SPB3.5, Asahi Intecc, Japan) was initially used via the right radial artery, cannulating the coronary artery was difficult. After manipulating the GC clockwise, the Impella device moved upwards with the GC motion, suggesting entrapment of the GC with the Impella outlet (Figure 1A and B; Supplementary material online , Video S1). We pushed the GC to the cardiac side and attempted to extract the GC using a single 0.035 inch conventional wire; however, it was difficult because of the interaction. Next, manually adjusting the Impella shaft’s position via the femoral artery while pushing the 0.035 inch Amplatz Extra-Stiff guidewire (Cook, USA) inserted into the GC as double wires against the aortic cusp disengaged the entrapment (Figure 1C and D). Subsequent percutaneous coronary intervention (PCI) using a non-backup type GC (Hyperion JL3.5, Asahi Intecc, Japan) was successfully performed without interaction with the Impella, and the patient recovered from low cardiac output syndrome (Figure 1E–G).