LHLei Hu

Lei Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lei Hu has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dispersive shock waves in gravity-capillary free-surface flows

    by Wangyang Zhao, Zhan Wang, Lei Hu

    This paper explores dispersive shock waves (DSWs) of gravity-capillary waves within the framework of the two-dimensional, fully nonlinear Euler equations. In this system, initial wave profiles characterised by a smooth step function evolve into modulated wavetrains that connect different constant states, a phenomenon arising from the interplay between nonlinear and dispersive effects. The Bond number, which quantifies the relative significance of gravity compared to surface tension, is crucial in determining the behaviour of the DSW solution. As the Bond number increases from zero, solutions traverse four distinct zones: the radiating DSW region, an unstable crossover region, the travelling DSW region, and the inverse radiating DSW region. The propagation velocities of DSWs can be estimated using the DSW fitting method alongside numerical results from travelling waves. Particular attention is given to travelling DSWs, which are characterised by a uniform wavetrain followed by an oscillatory decaying wavepacket. Notably, the high platform and its extended periodic wavetrain can be part of a specific type of gravity-capillary solitary wave that features an oscillatory pulse, with the number of oscillations at the core potentially increasing indefinitely. The Whitham modulation theory for the Euler equations is employed to describe the modulation parameters – such as wavenumber, amplitude and wave mean – in the travelling DSW region. Finally, we discuss the bifurcation mechanism of solitary waves with oscillatory pulses in the Euler equations, along with analyses of their stability. It is also demonstrated that for relatively small Bond numbers, a series of trapped bubbles can occur along the bifurcation curves, representing the limiting configuration of this type of solitary wave.


  • Diffraction and Interaction of Interfacial Solitons in a Two-Layer Fluid of Great Depth

    by Lei Hu, Xu-Dan Luo, Zhan Wang

    This paper aims to present a novel isotropic bidirectional model for studying weakly dispersive and weakly nonlinear atmospheric internal waves in a three-dimensional system consisting of two superimposed, incompressible, and inviscid fluids. The newly developed equation is the Benjamin–Benney–Luke (BBL) equation, a generalization of the famous two-dimensional Benjamin–Ono (2DBO) equation and the Benney–Luke equation, derived using the nonlocal Ablowitz–Fokas–Musslimani formulation of water waves. The evolution results of the BBL and 2DBO equations, performed by implementing the classic fourth-order Runge–Kutta method, the pseudospectral scheme with the integrating factor method, and the windowing scheme, show that the anisotropic 2DBO equation agrees well with the isotropic BBL model for problems being investigated, namely the focus is the central part of the soliton evolution/interaction zone. By applying the Whitham modulation theory, modulation equations for the 2DBO equation are obtained in this paper for analyzing the soliton dynamics in five different initial-value problems (truncated line soliton, line soliton, bent-stem soliton, bent soliton, and reverse bent soliton). In addition, corresponding numerical results are obtained and shown to agree well with the theoretical predictions. Both theoretical and numerical results reveal the formation conditions of the Mach expansion, as well as the specific relationship between the amplitude of the Mach stem and the initial data.


  • A 2-DOFs Planar Grinding End-Effector for Robotic Laminectomy

    by Wei Duan, Xuquan Ji, Lei Hu, Wenyong Liu

    Robotic end effector accurately operated in small and confined surgical area in laminectomy can improve the efficiency of robotic surgery. This paper proposed a two-DOFs planar grinding end-effector for robotic laminectomy, which can move along any curve within the planar operation area. The end-effector adopts an arc RCM mechanism, which kinematic analysis gives a working space of an annular sector with a minimum radius of 137 mm, a maximum radius of 162.3 mm, a central angle of 1.65 rad. The structure rationality of the end-effector is verified through static analysis. The prototype was developed and controlled based on TwinCAT-PC architecture. Experiments of positioning accuracy give a repeated positioning accuracy of 0.1 mm. Experiments of ex vivo bone grinding gives an operation accuracy of 1.5 mm in a simulated clinical environment. The proposed prototype can be used for robotic laminectomy in combination with the navigation robotic arm.

  • Open Access

    Tissue Recognition Based on Electrical Impedance Classified by Support Vector Machine in Spinal Operation Area

    by Bingrong Chen, Yongwang Shi, Jiahao Li, Jiliang Zhai, Liang Liu, Wenyong Liu, Lei Hu, Yu Zhao

    Objective One of the major difficulties in spinal surgery is the injury of important tissues caused by tissue misclassification, which is the source of surgical complications. Accurate recognization of the tissues is the key to increase safety and effect as well as to reduce the complications of spinal surgery. The study aimed at tissue recognition in the spinal operation area based on electrical impedance and the boundaries of electrical impedance between cortical bone, cancellous bone, spinal cord, muscle, and nucleus pulposus. Methods Two female white swines with body weight of 40 kg were used to expose cortical bone, cancellous bone, spinal cord, muscle, and nucleus pulposus under general anesthesia and aseptic conditions. The electrical impedance of these tissues at 12 frequencies (in the range of 10-100 kHz) was measured by electrochemical analyzer with a specially designed probe, at 22.0-25.0 degrees C and 50%-60% humidity. Two types of tissue recognition models - one combines principal component analysis (PCA) and support vector machine (SVM) and the other combines combines SVM and ensemble learning - were constructed, and the boundaries of electrical impedance of the five tissues at 12 frequencies of current were figured out. Linear correlation, two-way ANOVA, and paired T-test were conducted to analyze the relationship between the electrical impedance of different tissues at different frequencies. Results The results suggest that the differences of electrical impedance mainly came from tissue type (p < 0.0001), the electrical impedance of five kinds of tissue was statistically different from each other (p < 0.0001). The tissue recognition accuracy of the algorithm based on principal component analysis and support vector machine ranged from 83%-100%, and the overall accuracy was 95.83%. The classification accuracy of the algorithm based on support vector machine and ensemble learning was 100%, and the boundaries of electrical impedance of five tissues at various frequencies were calculated. Conclusion The electrical impedance of cortical bone, cancellous bone, spinal cord, muscle, and nucleus pulposus had significant differences in 10-100 kHz frequency. The application of support vector machine realized the accurate tissue recognition in the spinal operation area based on electrical impedance, which is expected to be translated and applied to tissue recognition during spinal surgery.


  • On a vortex filament with the axial velocity

    by Lei Hu, Yi-Tian Gao, Xin Yu, Ting-Ting Jia, Liu-Qing Li, Cui-Cui Ding, Gao-Fu Deng

  • Robot‐assisted percutaneous vertebroplasty under local anaesthesia for osteoporotic vertebral compression fractures: a retrospective, clinical, non‐randomized, controlled study

    by Bin Shi, Lei Hu, Hailong du, Jian Zhang, Wen Zhao, Lihai Zhang

    Research and design: A retrospective, clinical, non‐randomized, controlled study.Objective: To evaluate the application of a new spinal navigation robot on percutaneous vertebroplasty (PVP) under local anaesthesia.Methods: The result of inserting the puncture needle into the simulated pedicle was observed in vitro. Thirty patients with thoracolumbar fractures were enrolled. The basic data, operation‐related data and clinical effect scores were recorded. The learning curve of robot‐guided surgery was analysed.Results: The maximum yaw angle of the puncture needle implanting into the simulated pedicle is 0.5°. The operation time (33.93 ± 5.97 min vs. 53.75 ± 14.08 min, p = 0.000) and the average X‐ray exposure time (31.43 ± 4.93 s vs. 54.69 ± 2.15 s, p = 0.000) was significantly less in the robot group. The surgeons quickly mastered the technique of robot‐guided pedicle puncture after three surgeries.Conclusions: Robot‐assisted PVP could performed under local anaesthesia with the new robot.


  • Open Access

    New Calibrator with Points Distributed Conical Helically for Online Calibration of C-Arm

    by Na Guo, Biao Yang, Yuhan Wang, Hongsheng Liu, Lei Hu, Tianmiao Wang

    To improve the accuracy of calibration of C-arm, and overcome the space limitation in surgery, we proposed a new calibrator for online calibration of C-arm. After the image rectification by a polynomial fitting-based global correction method, the C-arm was assumed as an ideal pinhole model. The relationships between two kinds of spatial calibration errors and the distribution of fiducial points were studied: the performance of FRE (Fiducial Registration Error) and TRE (Target Registration Error) were not consistent, but both were best at the 12 marked points; the TRE decreased with the increase of the uniformity of calibration points distribution, and with the decrease of the distance between the target point and the center of calibration points. A calibrator with 12 fiducial points conical helically distributed, which could be placed on the knee, was an attractive option. A total of 10 experiments on C-arm calibration accuracy were conducted and the mean value of mapping error was 0.41 mm. We designed an ACL reconstruction navigation system and carried out specimen experiments on 4 pairs of dry femur and tibia. The mean accuracy of navigation system was 0.85 mm, which is important to the tunnel positioning for ACL reconstruction.