Ladislava Cerna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ladislava Cerna has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Vitezslav Benda
Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 166 27 Prague, Czech Republic
3 shared publications - Tomas Finsterle
Faculty of Electrical Engineering, Czech Technical University in Prague, Technická 2, 160 00 Prague, Czech Republic
2 shared publications Jana Safrankova
Czech University of Life Sciences Prague, Prague, Czech Republic
1 shared publication- Martin Libra
Faculty of Engineering, Czech University of Life Sciences Prague, Kamýcká 129, 165 00 Prague, Czech Republic
1 shared publication Pavel Hrzina
Czech Technical University in Prague, Prague, Czech Republic
1 shared publication- Pavel Hrzina
Faculty of Electrical Engineering, Czech Technical University 166 27, Prague Czech Republic
1 shared publication
Latest Publications
- Open Access
- 25 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (7) , 3363
A Note on Limits and Trends in PV Cells and Modules
The key components of photovoltaic (PV) systems are PV modules representing basic devices, which are able to operate in outdoor conditions for a long time. PV modules can be manufactured from different materials using different production technologies. The main criterion supporting or limiting the successful placement of specific technologies on the market is the price of electricity produced by PV systems. The levelized cost of energy (LCOE) method considers investment costs, operating costs, and the total energy produced during a PV system’s service life. The influence of price, efficiency, and service life of PV modules on the LCOE (together with the availability of materials) sets limits for applicable technologies. Increasing the efficiency of the modules from 21% to 23% could lead to a reduction of the area-dependent part of the PV system costs by 8.7%. Extending the service life from 25 to 30 years could reduce the LCOE by about 10%. As shown in the work, wafer-based crystalline silicon technologies best meet these criteria due to their high efficiency, low costs, long service life, and the availability of materials at present. Technological innovations make it possible to increase the efficiency of the modules closer to the physical limits and to extend the service life of the modules.
- 25 March 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (7) , 3363
Open AccessA Note on Limits and Trends in PV Cells and Modules
The key components of photovoltaic (PV) systems are PV modules representing basic devices, which are able to operate in outdoor conditions for a long time. PV modules can be manufactured from different materials using different production technologies. The main criterion supporting or limiting the successful placement of specific technologies on the market is the price of electricity produced by PV systems. The levelized cost of energy (LCOE) method considers investment costs, operating costs, and the total energy produced during a PV system’s service life. The influence of price, efficiency, and service life of PV modules on the LCOE (together with the availability of materials) sets limits for applicable technologies. Increasing the efficiency of the modules from 21% to 23% could lead to a reduction of the area-dependent part of the PV system costs by 8.7%. Extending the service life from 25 to 30 years could reduce the LCOE by about 10%. As shown in the work, wafer-based crystalline silicon technologies best meet these criteria due to their high efficiency, low costs, long service life, and the availability of materials at present. Technological innovations make it possible to increase the efficiency of the modules closer to the physical limits and to extend the service life of the modules.
- 3 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (2) , 565-571
Quick Diagnostic Tool for Thin-Film Photovoltaic Power Plants Utilizing Dark Current Measurement
There exist many photovoltaic (PV) power plants which are based on thin-film technology. Unlike PV power plant with crystalline silicon technology, the diagnostic possibilities of thin-film PV modules are limited due to seasonal effects and problematic utilization of thermography. The main problem of degradation of these PV plants is the area degradation which affects even PV power plants with transformer inverters. Although there exist measurement methods based on I–V curve measurement, these methods require specific climatic conditions (clear sky, sufficient irradiance) and time. Here, we present the novel approach to diagnose thin-film modules affected with degradation which provides quick results with low-cost equipment.
- 3 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (2) , 565-571
Quick Diagnostic Tool for Thin-Film Photovoltaic Power Plants Utilizing Dark Current Measurement
There exist many photovoltaic (PV) power plants which are based on thin-film technology. Unlike PV power plant with crystalline silicon technology, the diagnostic possibilities of thin-film PV modules are limited due to seasonal effects and problematic utilization of thermography. The main problem of degradation of these PV plants is the area degradation which affects even PV power plants with transformer inverters. Although there exist measurement methods based on I–V curve measurement, these methods require specific climatic conditions (clear sky, sufficient irradiance) and time. Here, we present the novel approach to diagnose thin-film modules affected with degradation which provides quick results with low-cost equipment.
- Open Access
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 11 (2) , 561-565
PV Panel and PV Inverter Damages Caused by Combination of Edge Delamination, Water Penetration, and High String Voltage in Moderate Climate
There exist over 2 GW of photovoltaic (PV) systems in the Czech Republic, exposed to moderate continental climate. Although there exist many PV modules defects, thanks to the generally the same production year 2009, only some of them are usual at systems installed in Czech Republic. This work shows delamination failures that are frequent in moderate climate conditions. Special account is taken into edge delamination defect and its possible propagation in modules of standard construction. Combined PV panel and PV inverter failure is caused by edge delamination with water penetration and high string voltage. The electric discharge channel is created between the string of solar panels and the grounded PV panel frames. The result of the discharge channel created because of edge delamination is inverter switch- off and few months later total destruction of the inverter because of protective relay damage. The number of combined PV panel and PV inverter failures is increasing substantially after ninth year of operation of PV panels in moderate climate. Additional sealing of the PV panel frames by transparent polysiloxane gel reduced the number of combined PV panel and PV inverter failures very substantially.
- 28 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 11 (2) , 561-565
Open AccessPV Panel and PV Inverter Damages Caused by Combination of Edge Delamination, Water Penetration, and High String Voltage in Moderate Climate
There exist over 2 GW of photovoltaic (PV) systems in the Czech Republic, exposed to moderate continental climate. Although there exist many PV modules defects, thanks to the generally the same production year 2009, only some of them are usual at systems installed in Czech Republic. This work shows delamination failures that are frequent in moderate climate conditions. Special account is taken into edge delamination defect and its possible propagation in modules of standard construction. Combined PV panel and PV inverter failure is caused by edge delamination with water penetration and high string voltage. The electric discharge channel is created between the string of solar panels and the grounded PV panel frames. The result of the discharge channel created because of edge delamination is inverter switch- off and few months later total destruction of the inverter because of protective relay damage. The number of combined PV panel and PV inverter failures is increasing substantially after ninth year of operation of PV panels in moderate climate. Additional sealing of the PV panel frames by transparent polysiloxane gel reduced the number of combined PV panel and PV inverter failures very substantially.