Robert M. Sweet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert M. Sweet has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Alexei S. Soares
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY, USA
9 shared publications - Jean Jakoncic
Brookhaven National Laboratory
9 shared publications - Dieter K. Schneider
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
8 shared publications - Herbert Bernstein
Fresh Pond Research Institute c/o National Light Source II, Brookhaven National Laboratory, Bldg 745, 11973-5000, Upton, NY,USA
8 shared publications - Martin R. Fuchs
National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, NY 11973, USA
7 shared publications - Sean McSweeney
National Synchrotron Light Source II Brookhaven National Laboratory 11973 Upton NY US
6 shared publications
Latest Publications
- Open Access
- 26 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 873-883
Structural biology at the National Synchrotron Light Source II
The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.
- 26 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 32 (4) , 873-883
Open AccessStructural biology at the National Synchrotron Light Source II
The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.
- Open Access
- 21 October 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (6) , 1480-1494
AMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II
The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s−1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.
- 21 October 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (6) , 1480-1494
Open AccessAMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II
The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 1012 photons s−1), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.
- Open Access
- 4 July 2022
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section F Structural Biology Communications
- Vol. 78 (7) , 281-288
Serial crystallography with multi-stage merging of thousands of images
KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.
- 4 July 2022
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section F Structural Biology Communications
- Vol. 78 (7) , 281-288
Open AccessSerial crystallography with multi-stage merging of thousands of images
KAMO and BLEND provide particularly effective tools to automatically manage the merging of large numbers of data sets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending BLEND to support additional clustering options such as the use of more accurate cell distance metrics and the use of reflection-intensity correlation coefficients to infer `distances' among sets of reflections. This increases the sensitivity to differences in unit-cell parameters and allows clustering to assemble nearly complete data sets on the basis of intensity or amplitude differences. If the data sets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. When starting from incomplete data sets, one applies KAMO twice, first using unit-cell parameters. In this step, either the simple cell vector distance of the original BLEND or the more sensitive NCDist is used. This step tends to find clusters of sufficient size such that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between reflections with a common hkl to merge clusters in a way that is sensitive to structural differences that may not have perturbed the unit-cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into categories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent of one another, it should be possible to greatly improve the efficacy of data-clustering software by using a multi-stage partitioning strategy. Here, one possible approach to multi-stage data clustering is demonstrated. The strategy is to use unit-cell clustering until the merged data are sufficiently complete and then to use intensity-based clustering. Using this strategy, it is demonstrated that it is possible to accurately cluster data sets from crystals that have subtle differences.
- Open Access
- 18 February 2022
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 78 (3) , 268-277
A simple technique to classify diffraction data from dynamic proteins according to individual polymorphs
One often observes small but measurable differences in the diffraction data measured from different crystals of a single protein. These differences might reflect structural differences in the protein and may reveal the natural dynamism of the molecule in solution. Partitioning these mixed-state data into single-state clusters is a critical step that could extract information about the dynamic behavior of proteins from hundreds or thousands of single-crystal data sets. Mixed-state data can be obtained deliberately (through intentional perturbation) or inadvertently (while attempting to measure highly redundant single-crystal data). To the extent that different states adopt different molecular structures, one expects to observe differences in the crystals; each of the polystates will create a polymorph of the crystals. After mixed-state diffraction data have been measured, deliberately or inadvertently, the challenge is to sort the data into clusters that may represent relevant biological polystates. Here, this problem is addressed using a simple multi-factor clustering approach that classifies each data set using independent observables, thereby assigning each data set to the correct location in conformational space. This procedure is illustrated using two independent observables, unit-cell parameters and intensities, to cluster mixed-state data from chymotrypsinogen (ChTg) crystals. It is observed that the data populate an arc of the reaction trajectory as ChTg is converted into chymotrypsin.
- 18 February 2022
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 78 (3) , 268-277
Open AccessA simple technique to classify diffraction data from dynamic proteins according to individual polymorphs
One often observes small but measurable differences in the diffraction data measured from different crystals of a single protein. These differences might reflect structural differences in the protein and may reveal the natural dynamism of the molecule in solution. Partitioning these mixed-state data into single-state clusters is a critical step that could extract information about the dynamic behavior of proteins from hundreds or thousands of single-crystal data sets. Mixed-state data can be obtained deliberately (through intentional perturbation) or inadvertently (while attempting to measure highly redundant single-crystal data). To the extent that different states adopt different molecular structures, one expects to observe differences in the crystals; each of the polystates will create a polymorph of the crystals. After mixed-state diffraction data have been measured, deliberately or inadvertently, the challenge is to sort the data into clusters that may represent relevant biological polystates. Here, this problem is addressed using a simple multi-factor clustering approach that classifies each data set using independent observables, thereby assigning each data set to the correct location in conformational space. This procedure is illustrated using two independent observables, unit-cell parameters and intensities, to cluster mixed-state data from chymotrypsinogen (ChTg) crystals. It is observed that the data populate an arc of the reaction trajectory as ChTg is converted into chymotrypsin.
- Open Access
- 1 January 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (1) , 280
Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II. Corrigendum
A correction in the paper by Lazo et al. [(2021). J. Synchrotron Rad. 28, 1649–1661] is made.
- 1 January 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (1) , 280
Open AccessRobotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II. Corrigendum
A correction in the paper by Lazo et al. [(2021). J. Synchrotron Rad. 28, 1649–1661] is made.
- 23 August 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (5) , 1649-1661
Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II
Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.
- 23 August 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (5) , 1649-1661
Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II
Here we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.
- Open Access
- 25 February 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 650-665
FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II
Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.
- 25 February 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (2) , 650-665
Open AccessFMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II
Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425, 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493, 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015, 1741, 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 1012 photons s−1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 1012 photons s−1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25, 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ, 5, 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5, 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.
- Open Access
A simple technique to classify diffraction data from dynamic proteins according to individual polymorphs
One often observes small but measurable differences in diffraction data measured from different crystals of a single protein. These differences might reflect structural differences in the protein and potentially reflect the natural dynamism of the molecule in solution. Partitioning these mixed-state data into single-state clusters is a critical step to extract information about the dynamic behavior of proteins from hundreds or thousands of single-crystal data sets. Mixed-state data can be obtained deliberately (through intentional perturbation) or inadvertently (while attempting to measure highly redundant single-crystal data). State changes may be expressed as changes in morphology, so that a subset of the polystates may be observed as polymorphs. After mixed-state data are deliberately or inadvertently measured, the challenge is to sort the data into clusters that may represent relevant biological polystates. Here we address this problem using a simple multi-factor clustering approach that classifies each data set using independent observables in order to assign each data set to the correct location in conformation space. We illustrate this method using two independent observables (unit cell constants and intensities) to cluster mixed-state data from chymotrypsinogen (ChTg) crystals. We observe that the data populate an arc of the reaction trajectory as ChTg is converted into chymotrypsin.
Open AccessA simple technique to classify diffraction data from dynamic proteins according to individual polymorphs
One often observes small but measurable differences in diffraction data measured from different crystals of a single protein. These differences might reflect structural differences in the protein and potentially reflect the natural dynamism of the molecule in solution. Partitioning these mixed-state data into single-state clusters is a critical step to extract information about the dynamic behavior of proteins from hundreds or thousands of single-crystal data sets. Mixed-state data can be obtained deliberately (through intentional perturbation) or inadvertently (while attempting to measure highly redundant single-crystal data). State changes may be expressed as changes in morphology, so that a subset of the polystates may be observed as polymorphs. After mixed-state data are deliberately or inadvertently measured, the challenge is to sort the data into clusters that may represent relevant biological polystates. Here we address this problem using a simple multi-factor clustering approach that classifies each data set using independent observables in order to assign each data set to the correct location in conformation space. We illustrate this method using two independent observables (unit cell constants and intensities) to cluster mixed-state data from chymotrypsinogen (ChTg) crystals. We observe that the data populate an arc of the reaction trajectory as ChTg is converted into chymotrypsin.
- Open Access
Serial Crystallography with Multi-stage Merging of 1000s of Images
KAMO and Blend provide particularly effective tools to manage automatically the merging of large numbers of datasets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending Blend to support additional clustering options such as use of more accurate cell distance metrics and use of reflection-intensity correlation coefficients to infer “distances” among sets of reflec- tions. This increases the sensitivity to differences in unit cell parameters and allows for clustering to assemble nearly complete datasets on the basis of intensity or ampli- tude differences. If datasets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. If starting from incomplete datasets, one applies KAMO twice, first using cell parameters. In this step we use either the simple cell vector distance of the original Blend, or we use the more sensi- tive NCDist. This step tends to find clusters of sufficient size so that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between the reflections having a common hkl to merge clusters in a way sensitive to structural differences that may not have perturbed the cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into cate- gories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent from one another, it should be possible to greatly improve the efficacy of data clustering software by using a multi-stage partitioning strategy. Here, we have demonstrated one possible approach to multi-stage data clustering. Our strategy is to use unit-cell clustering until merged data is sufficiently complete then to use intensity-based clustering. We have demonstrated that, using this strategy, we are able to accurately cluster datasets from crystals that have subtle differences.
Open AccessSerial Crystallography with Multi-stage Merging of 1000s of Images
KAMO and Blend provide particularly effective tools to manage automatically the merging of large numbers of datasets from serial crystallography. The requirement for manual intervention in the process can be reduced by extending Blend to support additional clustering options such as use of more accurate cell distance metrics and use of reflection-intensity correlation coefficients to infer “distances” among sets of reflec- tions. This increases the sensitivity to differences in unit cell parameters and allows for clustering to assemble nearly complete datasets on the basis of intensity or ampli- tude differences. If datasets are already sufficiently complete to permit it, one applies KAMO once and clusters the data using intensities only. If starting from incomplete datasets, one applies KAMO twice, first using cell parameters. In this step we use either the simple cell vector distance of the original Blend, or we use the more sensi- tive NCDist. This step tends to find clusters of sufficient size so that, when merged, each cluster is sufficiently complete to allow reflection intensities or amplitudes to be compared. One then uses KAMO again using the correlation between the reflections having a common hkl to merge clusters in a way sensitive to structural differences that may not have perturbed the cell parameters sufficiently to make meaningful clusters. Many groups have developed effective clustering algorithms that use a measurable physical parameter from each diffraction still or wedge to cluster the data into cate- gories which then can be merged, one hopes, to yield the electron density from a single protein form. Since these physical parameters are often largely independent from one another, it should be possible to greatly improve the efficacy of data clustering software by using a multi-stage partitioning strategy. Here, we have demonstrated one possible approach to multi-stage data clustering. Our strategy is to use unit-cell clustering until merged data is sufficiently complete then to use intensity-based clustering. We have demonstrated that, using this strategy, we are able to accurately cluster datasets from crystals that have subtle differences.
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (1) , 012003
Three Biomedical Beamlines at NSLS-II for Macromolecular Crystallography and Small-Angle Scattering
We report on the status of the development of three beamlines for the National Synchrotron Light Source-II (NSLS-II), two for macromolecular crystallography (MX), and one for wide- and small-angle x-ray scattering (SAXS). Funded by the National Institutes of Health, this suite of Advanced Beamlines for Biological Investigations with X-rays (ABBIX) is scheduled to begin operation by 2015. The two MX beamlines share a sector with identical canted in-vacuum undulators (IVU21). The microfocusing FMX beamline on the inboard branch employs a two-stage horizontal source demagnification scheme, will cover an energy range of 5 – 23 keV, and at 12.7 keV will focus a flux of up to 1013 ph/s into a spot of 1 μm width. The companion AMX beamline on the short outboard branch of the sector is tunable in the range of 5 – 18 keV and has a native focus of 4 μm (h) × 2 μm (v). This robust beamline will be highly automated, have high throughput capabilities, and with larger beams and low divergence will be well suited for structure determinations on large complexes. The high brightness SAXS beamline, LIX, will provide multiple dynamic and static experimental systems to support scientific programs in solution scattering, membrane structure determination, and tissue imaging. It will occupy a different sector, equipped with a single in-vacuum undulator (IVU23). It can produce beams as small as 1 μm across, and with a broad energy range of 2.1 – 18 keV it will support anomalous SAXS.
- 22 March 2013
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 425 (1) , 012003
Three Biomedical Beamlines at NSLS-II for Macromolecular Crystallography and Small-Angle Scattering
We report on the status of the development of three beamlines for the National Synchrotron Light Source-II (NSLS-II), two for macromolecular crystallography (MX), and one for wide- and small-angle x-ray scattering (SAXS). Funded by the National Institutes of Health, this suite of Advanced Beamlines for Biological Investigations with X-rays (ABBIX) is scheduled to begin operation by 2015. The two MX beamlines share a sector with identical canted in-vacuum undulators (IVU21). The microfocusing FMX beamline on the inboard branch employs a two-stage horizontal source demagnification scheme, will cover an energy range of 5 – 23 keV, and at 12.7 keV will focus a flux of up to 1013 ph/s into a spot of 1 μm width. The companion AMX beamline on the short outboard branch of the sector is tunable in the range of 5 – 18 keV and has a native focus of 4 μm (h) × 2 μm (v). This robust beamline will be highly automated, have high throughput capabilities, and with larger beams and low divergence will be well suited for structure determinations on large complexes. The high brightness SAXS beamline, LIX, will provide multiple dynamic and static experimental systems to support scientific programs in solution scattering, membrane structure determination, and tissue imaging. It will occupy a different sector, equipped with a single in-vacuum undulator (IVU23). It can produce beams as small as 1 μm across, and with a broad energy range of 2.1 – 18 keV it will support anomalous SAXS.