MAMohammad Alabdulkareem

Mohammad Alabdulkareem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammad Alabdulkareem has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Light-Curing Distance on Polymerization Behavior of Resin Composites: A Systematic Review and Meta-Analysis

    by Mohammad Alabdulkareem, Waseem Radwan, Ammar Abumustafa, Dalia Alharith, Basil Alamassi, Oubada Sulaiman, Khaled Aldalaan

    Background: The distance between the light-curing unit (LCU) tip and the resin composite surface is a clinically important factor that may influence the quality of polymerization. However, the magnitude and consistency of its effects across different composite materials and curing devices remain unclear. Objective: To systematically evaluate the effect of LCU tip-to-surface distance on the polymerization behavior of resin composites, including degree of conversion (DC), microhardness, depth of cure, and flexural strength. Methods: A systematic search of PubMed/MEDLINE, Scopus, Web of Science, Embase, and Google Scholar was conducted from database inception to August 2026. In vitro studies that investigated at least two curing distances and reported quantitative polymerization outcomes were included. Methodological quality was assessed using a modified reporting checklist for in vitro dental materials research (not a validated risk-of-bias instrument). Findings were synthesized narratively according to the SWiM framework, with exploratory random-effects meta-analyses performed where data permitted. Results: Sixteen in vitro studies met the inclusion criteria. The narrative synthesis indicated that there was a tendency towards an association of increasing curing distance with decreased degree of conversion (DC), hardness, flexural strength, and depth of cure. However, the size of the effect depended on material, light-curing unit, irradiance, and exposure time. In exploratory random effects meta-analyses, which were based on two to four studies, an increase in distance was associated with lower values in comparison to direct curing at 0 mm, with all estimates in the same direction: DC was lower by 12.26 percentage points (95% confidence interval [CI], 8.07–16.45; eight comparisons from four studies), hardness was lower (standard mean difference [SMD] = 1.18; 95% CI, 0.17–2.18; seven comparisons from three studies), Knoop hardness was lower (mean difference [MD] = −5.34; 95% CI, −8.69 to −1.98; two studies), flexural strength was lower by 12.18 MPa (95% CI, −21.86 to −2.50; three studies), and depth of cure was lower by 0.54 mm (95% CI, 0.36–0.73; two studies). Heterogeneity was considerable to very high (I2 = 71.7–99.7%); 95% prediction intervals for DC, hardness, flexural strength, and depth of cure included zero, and estimates for hardness and flexural strength were not statistically significant with the Hartung–Knapp adjustment. In a single study (not pooled), bulk-fill composites demonstrated higher DC than a conventional composite at 0 mm, whereas the conventional composite showed slightly higher DC than the bulk-fill composites at 4 mm. DC was higher at the top than the bottom surface at 0 mm in three out of three studies that reported both values. These pooled estimates should be considered exploratory. Considerable heterogeneity was identified across pooled analyses. Conclusions: In these in vitro studies, a greater distance between the LCU tip and the composite surface was generally associated with lower polymerization-related properties of resin composites, with differences most often reported from about 4 mm in the experimental settings tested; this is an experimental observation rather than a validated clinical threshold, and the maximum distance investigated was 9 mm. These exploratory findings are compatible with minimizing unnecessary curing distance, but their clinical relevance has not been established. Further research, including clinical studies, should determine whether compensation for curing distance and specific material/LCU combinations can overcome such differences.

  • Open Access

    Ultrasonic activation of calcium silicate sealers in single-cone obturation: A micro-CT study of voids and gaps formation

    by Ammar AbuMostafa, Maram AlHati, Mohammad Alabdulkareem

    Aim: This study investigated the effect of ultrasonic activation (UA) on porosity formation in root fillings using two calcium silicate-based sealers. Methods: Forty single-rooted premolars were decoronated, and the roots were adjusted to a standardized length of 11 mm. Canals were shaped with the #F3 ProTaper Ultimate file system. Teeth were divided into two groups for single-cone obturation with two different sealers: Angelus Bio-C Sealer (n = 20) and TotalFill BC Sealer (n = 20). Each group was subdivided into two subgroups (with and without UA). In the UA groups, the tweezers holding the GP cone were contacted by a smooth ultrasonic tip for two to three seconds. After obturation, samples were scanned using micro-CT. Group differences in mean total porosity were analyzed with Mann-Whitney Z and Kruskal-Wallis tests, followed by Dunn-Bonferroni post-hoc tests. Interfacial gaps and internal voids were also quantified separately to assess distribution. Results: TotalFill BC Sealer with ultrasonic activation demonstrated the highest mean total porosity, whereas Angelus Bio-C Sealer without ultrasonic activation exhibited the lowest, though this difference was not statistically significant (p = 0.428). Quantitative analysis revealed that interfacial gaps were significantly higher than internal voids across all groups (p < 0.05). Total porosity varied significantly across root levels (p < 0.001), with the cervical third showing the greatest proportion of porosities, followed by the apical third, while the middle third consistently demonstrated the lowest porosity volume. Conclusion: No significant difference in total porosity was found between Bio-C Sealer and TotalFill BC Sealer, regardless of ultrasonic activation. However, interfacial gaps represented the majority of the total porosity volume, and significant differences in distribution were observed across different root levels.


  • Open Access

    Artificial Intelligence in Dental Treatment Planning and Diagnostic Decision‐Making: A Systematic Review and Meta‐Analysis

    by Mohammad Alabdulkareem, Momen Atieh, Ammar AbuMostafa, Khaled Aldalaan, Nada Alturki

    Objectives: This systematic review and meta‐analysis aimed to synthesize the available evidence on the use of AI in dental diagnostic decision‐making and treatment planning, evaluating both diagnostic accuracy and its influence on clinical decision‐making across different dental specialties and imaging modalities. Methods: A comprehensive search of MEDLINE, Embase, Cochrane CENTRAL, Web of Science, and Scopus was conducted from database inception to December 2025. Eligible studies evaluated AI algorithms used for dental diagnostic tasks or treatment planning and reported quantitative performance metrics or measurable decision‐making outcomes. Random‐effects meta‐analyses were conducted to pool diagnostic performance measures. Results: Twenty‐seven studies involving 60,857 radiographic images were included. AI systems demonstrated a pooled sensitivity of 0.85 (95% CI: 0.76–0.91) and specificity of 0.94 (95% CI: 0.86–0.97). The pooled F1‐score was 0.90 (95% CI: 0.77–0.96), and pooled precision was 0.88 (95% CI: 0.71–0.96). For segmentation tasks, the pooled Dice Similarity Coefficient was 0.89 (95% CI: 0.13–1.00). Substantial heterogeneity was observed across studies (I² > 95%). YOLO‐based architectures achieved the highest performance for tooth detection and segmentation, with sensitivities approaching 99% and mean average precision exceeding 0.96. AI assistance also improved diagnostic efficiency and interobserver agreement while reducing diagnostic interpretation time. Conclusions: AI systems demonstrate strong diagnostic performance in dental imaging and decision support, particularly for tooth detection, segmentation, and pathology identification. However, substantial heterogeneity, retrospective study designs, and limited external validation highlight the need for rigorous prospective evaluation before widespread clinical implementation.


  • Open Access

    Effect of Various Root Canal Irrigation Techniques on Root Dentin Mechanical Properties: An In Vitro Study

    by Ammar AbuMostafa, Mohammed Almarshad, Dalia Alharith, Mohammad Alabdulkareem, Alanoud Alqahtani, Bushra Alhawsawi, Basil Alamassi

    Background: Root canal irrigation is essential for effective canal disinfection, but activation techniques may alter the mechanical properties of root dentin. Objective: To evaluate the effects of four different root canal irrigation techniques on root dentin nanohardness, elastic modulus, and flexural strength. Methods: Forty extracted human mandibular premolars with single straight canals were randomly allocated to four groups ( n = 10): traditional needle irrigation, passive ultrasonic irrigation (PUI), negative‐pressure irrigation, and XP‐Endo Finisher irrigation. During canal preparation, specimens were irrigated with 1% sodium hypochlorite. The final irrigation procedures were performed using 2.5% sodium hypochlorite and 17% EDTA with identical irrigant sequences and volumes across all groups. Root dentin nanohardness, elastic modulus, and flexural strength were evaluated. Data were analyzed using one‐way ANOVA and Tukey’s post hoc test ( p < 0.05). Results: Traditional needle irrigation demonstrated the highest nanohardness (0.489 ± 0.064 GPa), whereas ultrasonic irrigation showed the lowest values (0.391 ± 0.021 GPa). Negative‐pressure irrigation (0.466 ± 0.043 GPa) and XP‐Endo Finisher irrigation (0.436 ± 0.056 GPa) showed intermediate values. Elastic modulus did not differ significantly among the groups ( p = 0.148). Likewise, no significant difference in flexural strength was observed among the irrigation protocols ( p = 0.371). Conclusion: Under the conditions of this in vitro study, ultrasonic irrigation reduced dentin nanohardness, whereas neither elastic modulus nor flexural strength was significantly affected by the irrigation protocol.

  • The socket shield technique for immediate implant placement: A systematic review and meta‐analysis

    by Momen A. Atieh, Maanas Shah, Mohammed Abdulkareem, Haif A. AlQahtani, Nabeel H. M. Alsabeeha

    Background: Immediate implant placement with socket shield technique (SST) may maintain the buccal bone plate and soft tissue levels, however, the potential clinical benefits of SST lack strong scientific evidence. The aim of this systematic review and meta‐analysis was to evaluate the effects of SST on dimensional changes of hard tissues, esthetic outcomes, implant stability, complication, and implant failure rates.Methods: Electronic databases were searched to identify randomized controlled trials (RCTs) that compared immediate implant placement with and without SST. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. Data were analyzed using a statistical software program.Results: A total of 982 studies were identified, of which, seven RCTs with 206 immediately placed dental implants in 191 participants were included. Overall meta‐analysis showed significant differences in the changes in buccal bone plate width (mean difference (MD) –0.22; 95% confidence interval (CI) –0.30 to −0.15; p < 0.0001) and height (MD –0.52; 95% CI ‐0.85 to −0.18; p = 0.002) in favor of SST. The use of SST was also associated with significantly less changes in peri‐implant marginal bone levels and better pink esthetic score than immediately placing implants without SST. The differences in implant stability, complication and implant failure rates were not statistically significant between immediate implant placement with or without SST.Conclusions: The short‐term complication and implant failure rates following immediate implant placement with or without SST were comparable. The SST has short‐term positive effects on the changes in width and height of buccal bone plate, peri‐implant marginal bone levels and esthetic outcomes. Further evidence from long‐term RCTs are still required to substantiate the current findings.Clinical Significance: SST can reduce changes in buccal plate width and height and improve the soft tissue profile following immediate implant placement in esthetic zone.


  • Open Access

    The role of prosthetic, orthodontic and implant-supported rehabilitation in the management of secondary malocclusion to maxillofacial trauma- A systematic review

    by Khaled Khalaf, Waad Kheder, Mohamed El-Kishawi, Haif A. AlQahtani, Fatemeh S. Ghiasi, Mohammad N. Alabdulkareem, Abdullah N. Zahiri, Noorieh I. Rahmani

    Purpose: Different approaches have been proposed to treat malocclusion secondary to the treatment of maxillofacial trauma. This study aimed to investigate the efficacy of prosthodontic treatment, orthodontic treatment, and implant-supported rehabilitation for the management of secondary malocclusion after maxillofacial trauma. Study selection: We searched five electronic databases and hand searched eight journals. The types of studies included were randomized controlled trials, cohorts, case–controls, and case series with at least eight patients with maxillofacial trauma and postoperative malocclusion. These studies used prosthetic treatment and implant-supported rehabilitation for secondary malocclusion after maxillofacial trauma. Risk of bias of eligible studies to be included in the final analysis was assessed independently by two authors using a tool for methodological quality assessment and synthesis of case series and case reports. Results: After initial screening and identification of titles and abstracts, full text of 44 articles were found and evaluated against inclusion criteria. Of these 42 articles were excluded and remaining two were included in the review. Both the studies were case series with moderate to high risk of bias. Conclusions: Both prosthetic treatment and implant-supported rehabilitation have the potential to restore secondary malocclusion after maxillofacial trauma. However, because less number of well-designed studies with high risk of bias were included in this systematic review, the findings should be interpreted with caution. Well-designed high-quality studies are required to draw definitive conclusions.