Anna-Lena Robisch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna-Lena Robisch has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Tim Salditt
University of Göttingen
3 shared publications - Christine Stadelmann
Department of Neuropathology University Medical Center Göttingen Göttingen Germany
2 shared publications - Franziska van der Meer
Universitätsmedizin Göttingen
2 shared publications - Mareike Töpperwien
Georg-August-Univ. Göttingen
2 shared publications - Marina Eckermann
Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
2 shared publications J Frohn
Institut für Röntgenphysik, Georg-August-Universität Göttingen, Friedrich-Hund-Platz 1, 37077 Göttingen, Germany
1 shared publication
Latest Publications
- Open Access
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235034
Iterative micro-tomography of biopsy samples from truncated projections with quantitative gray values
Three-dimensional reconstruction from truncated two-dimensional projections cannot be solved analytically without prior knowledge of the sample or access to the non-truncated projections. To suppress reconstruction artifacts in region of interest (ROI) or local tomography, an iterative algorithm has been devised based on back-projection and re-projection, assuming an approximately cylindrical shape of the entire sample of general homogeneity, which is especially applicable for micro-tomography of biopsy samples from biological tissue. Tomographic reconstruction is iteratively refined by minimizing the mismatch between an empty ROI and the reconstruction from the difference between measured sinogram and forward projected ROI reconstruction. By numerical simulation and experimental demonstration, it is shown that the algorithm is not only able to reconstruct quantitative gray values, but also to reduce artifacts of peripheral glow, and may lead to increased image sharpness. The method is particularly suitable for examination of biopsy/autopsy-samples of soft tissue by micro/nano-computed tomography.
- 27 November 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235034
Open AccessIterative micro-tomography of biopsy samples from truncated projections with quantitative gray values
Three-dimensional reconstruction from truncated two-dimensional projections cannot be solved analytically without prior knowledge of the sample or access to the non-truncated projections. To suppress reconstruction artifacts in region of interest (ROI) or local tomography, an iterative algorithm has been devised based on back-projection and re-projection, assuming an approximately cylindrical shape of the entire sample of general homogeneity, which is especially applicable for micro-tomography of biopsy samples from biological tissue. Tomographic reconstruction is iteratively refined by minimizing the mismatch between an empty ROI and the reconstruction from the difference between measured sinogram and forward projected ROI reconstruction. By numerical simulation and experimental demonstration, it is shown that the algorithm is not only able to reconstruct quantitative gray values, but also to reduce artifacts of peripheral glow, and may lead to increased image sharpness. The method is particularly suitable for examination of biopsy/autopsy-samples of soft tissue by micro/nano-computed tomography.
- Open Access
- 10 June 2020
- Published by Springer Nature
- Vol. 134, 35-70
Coherent X-ray Imaging
This chapter briefly summarizes some main concepts of coherent X-ray imaging. More specifically, we consider lensless X-ray imaging based on free-space propagation. It is meant as primer and tutorial which should help to understand later chapters of this book devoted to X-ray imaging, phase contrast methods, and optical inverse problems. We start by an introduction to scalar wave propagation, first in free space, followed by propagation of short wavelength radiation within matter. This provides the basic tools to consider the mechanisms of coherent image formation in a lensless X-ray microscope. The recorded intensities are inline holograms created by self-interference behind the object. We then present single-step and iterative fixed-point techniques based on alternating projections onto constraint sets as tools to decode the measured intensities (phase retrieval). The chapter closes with a brief generalization of two dimensional coherent imaging to three dimensional imaging by tomography.
- 10 June 2020
- Published by Springer Nature
- Vol. 134, 35-70
Open AccessCoherent X-ray Imaging
This chapter briefly summarizes some main concepts of coherent X-ray imaging. More specifically, we consider lensless X-ray imaging based on free-space propagation. It is meant as primer and tutorial which should help to understand later chapters of this book devoted to X-ray imaging, phase contrast methods, and optical inverse problems. We start by an introduction to scalar wave propagation, first in free space, followed by propagation of short wavelength radiation within matter. This provides the basic tools to consider the mechanisms of coherent image formation in a lensless X-ray microscope. The recorded intensities are inline holograms created by self-interference behind the object. We then present single-step and iterative fixed-point techniques based on alternating projections onto constraint sets as tools to decode the measured intensities (phase retrieval). The chapter closes with a brief generalization of two dimensional coherent imaging to three dimensional imaging by tomography.
- Open Access
- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 013502-15
Phase-contrast x-ray tomography of neuronal tissue at laboratory sources with submicron resolution
Phase-contrast x-ray tomography offers a unique potential to realize 3-D virtual histology, with cellular and even subcellular resolution, and for 3-D volumes, which are inaccessible by more established techniques. While volume and throughput in conventional histology are limited by slicing and staining, volume penetration for both light- and electron-based microscopy techniques is unsuitable for larger tissue volumes. Several propagation-based x-ray phase-contrast tomography studies with synchrotron radiation have demonstrated this potential, both for stained1 – 3 and unstained 4,5 soft tissues, and including mouse models6 as well as human tissue.5,7 Many different types of tissues have been imaged, including heart and cardiovascular systems,8 – 10 skin,11 cancerous tissue in particular for mamma,12 the peripheral nervous system,1,13 and tissues of the central nervous system.7,14 – 16
- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 013502-15
Open AccessPhase-contrast x-ray tomography of neuronal tissue at laboratory sources with submicron resolution
Phase-contrast x-ray tomography offers a unique potential to realize 3-D virtual histology, with cellular and even subcellular resolution, and for 3-D volumes, which are inaccessible by more established techniques. While volume and throughput in conventional histology are limited by slicing and staining, volume penetration for both light- and electron-based microscopy techniques is unsuitable for larger tissue volumes. Several propagation-based x-ray phase-contrast tomography studies with synchrotron radiation have demonstrated this potential, both for stained1 – 3 and unstained 4,5 soft tissues, and including mouse models6 as well as human tissue.5,7 Many different types of tissues have been imaged, including heart and cardiovascular systems,8 – 10 skin,11 cancerous tissue in particular for mamma,12 the peripheral nervous system,1,13 and tissues of the central nervous system.7,14 – 16
- Open Access
- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 013501-13
Nanoscale x-ray holotomography of human brain tissue with phase retrieval based on multienergy recordings
In the hard x-ray regime with multi-keV photon energy , variations in the index of refraction are dominated by , and the imaginary contribution accounting for absorption becomes extremely weak. Correspondingly, the main interaction of light exploitable for imaging is related to the local phase shifts of the incoming radiation in proportion to the amount and electron density of the material traversed by the beam. Holographic x-ray phase-contrast imaging1 exploits this contrast mechanism due to interference of scattered and transmitted illumination.2 Combined with tomography, phase-contrast radiography is a well-established and nondestructive tool to image soft tissue samples in three dimensions.3,4,5- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 013501-13
Open AccessNanoscale x-ray holotomography of human brain tissue with phase retrieval based on multienergy recordings
In the hard x-ray regime with multi-keV photon energy , variations in the index of refraction are dominated by , and the imaginary contribution accounting for absorption becomes extremely weak. Correspondingly, the main interaction of light exploitable for imaging is related to the local phase shifts of the incoming radiation in proportion to the amount and electron density of the material traversed by the beam. Holographic x-ray phase-contrast imaging1 exploits this contrast mechanism due to interference of scattered and transmitted illumination.2 Combined with tomography, phase-contrast radiography is a well-established and nondestructive tool to image soft tissue samples in three dimensions.3,4,5