RHRobert Huhle

Robert Huhle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Huhle has a total of 83 co-authors. Here are the top co-authors by number of shared publications:

  • Marcelo Gama de Abreu

    Department of Anaesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

    6 shared publications
  • Thea Koch

    Department of Anaesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

    5 shared publications
  • Marcelo Gama de Abreu

    Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, Dresden University of Technology, Dresden 01307, Germany; Division of Intensive Care and Resuscitation, Department of Anesthesiology, Integrated Hospital Care Institute, Cleveland Clinic, Cleveland, OH, USA; Outcomes Research Consortium, Department of Anesthesiology, Integrated Hospital Care Institute, Cleveland Clinic, Cleveland, OH, USA

    4 shared publications
  • Jakob Wittenstein

    Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

    3 shared publications
  • Martin Scharffenberg

    Department of Anaesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

    3 shared publications
  • Andreas Güldner

    Department of Anesthesiology and Intensive Care Medicine, Pulmonary Engineering Group, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

    2 shared publications

Latest Publications

  • Open Access

    Dual-energy computed tomography derived pulmonary blood volume: association with pulmonary blood flow

    by Jakob Wittenstein, Rudi Apolle, Martin Scharffenberg, Carolin Rothmann, Sabine Müller, Ralf-Thorsten Hoffmann, Esther G. C. Troost, Thea Koch, Marcelo Gama de Abreu, Robert Huhle

    Background: Distribution of ventilation and pulmonary perfusion are the major determinants of pulmonary gas exchange. To study and compare strategies of mechanical ventilation in respiratory research accurate and high-resolution methods are needed to derive distribution of ventilation and perfusion with minimal additional intervention or radiation allowing repeated measurements. Dual-energy computed tomography (DECT) is an imaging technique allowing for the derivation of regional pulmonary perfused blood volume, as a surrogate for pulmonary perfusion (PP DECT ). Here accuracy of PP DECT is evaluated in comparison to pulmonary blood flow measured with fluorescence-labeled microspheres (PP FLM ). Its feasibility of repeated measurements is evaluated. Methods: Agreement between PP FLM and PP DECT was assessed by regression as well as Bland–Altman analysis in three anesthetized pigs using DECT and fluorescence labelled microspheres, respectively. Measurements were performed in two-lung and, after right sided thoracotomy, at one-lung ventilation with inhaled nitric oxide. PP FLM and PP DECT were assessed in three different regions of interest (ROI): the right (non-ventilated) and left (ventilated) upper and lower lung, yielding a total of 45 paired measurements over four hours. Persistent iodine accumulation was assessed by additional DECT scans before each contrast administration. Results: Regression analysis revealed a good overall association (R2 = 0.81) between PP FLM and PP DECT , with PP DECT substantially overestimating PP FLM up to 30%, with limits of agreement of -18 and 18%, Low PP FLM was underestimated, while high PP FLM was overestimated by PP DECT , indicating a higher sensitivity of the later. Changes of PP DECT and PP FLM had a concordance of 69.4% for all measurements. Agreement and concordance were highest in ventilated and lowest in non-ventilated ROIs. No persistent iodine enhancement was detected in the lung parenchyma after repetitive measurements per hour. Conclusions: Dual-energy CT based measurement of pulmonary perfusion shows promising results indicating its feasibility in translational research on strategies of mechanical ventilation.


  • Open Access

    The PROtective VEntilation (PROVE) Network - advancing research and collaboration in mechanical ventilation

    by Marcus J Schultz, Lorenzo Ball, Martin Bernardi, Denise Battaglini, Laura A Buiteman, Juliana Carvalho Ferreira, Marcelo Gama de Abreu, Silvia De Rosa, Sabrine N Hemmes, Robert Huhle, et al.

    The PROtective VEntilation (PROVE) Network is a globally-recognized collaborative research group dedicated to advancing research, education, and collaboration in the field of mechanical ventilation. Established to address critical questions in intraoperative and intensive care ventilation, the network focuses on improving outcomes for patients undergoing mechanical ventilation in diverse settings, including operating rooms, intensive care […] ABSTRACT The PROtective VEntilation (PROVE) Network is a globally-recognized collaborative research group dedicated to advancing research, education, and collaboration in the field of mechanical ventilation. Established to address critical questions in intraoperative and intensive care ventilation, the network focuses on improving outcomes for patients undergoing mechanical ventilation in diverse settings, including operating rooms, intensive care […]

  • Open Access

    Induction of subject-ventilator asynchrony by variation of respiratory parameters in a lung injury model in pigs

    by Xi Ran, Martin Scharffenberg, Jakob Wittenstein, Mark Leidermann, Andreas Güldner, Thea Koch, Marcelo Gama de Abreu, Robert Huhle

    Background: Subject-ventilator asynchrony (SVA) was shown to be associated with negative clinical outcomes. To elucidate pathophysiology pathways and effects of SVA on lung tissue histology a reproducible animal model of artificially induced asynchrony was developed and evaluated. Methods: Alterations in ventilator parameters were used to induce the three main types of asynchrony: ineffective efforts (IE), auto-triggering (AT), and double-triggering (DT). Airway flow and pressure, as well as oesophageal pressure waveforms, were recorded, asynchrony cycles were manually classified and the asynchrony index (AIX) was calculated. Bench tests were conducted on an active lung simulator with ventilator settings altered cycle by cycle. The developed algorithm was evaluated in three pilot experiments and a study in pigs ventilated for twelve hours with AIX = 25%. Results: IE and AT were induced reliably and fail-safe by end-expiratory hold and adjustment of respiratory rate, respectively. DT was provoked using airway pressure ramp prolongation, however not controlled specifically in the pilots. In the subsequent study, an AIX = 28.8% [24.0%-34.4%] was induced and maintained over twelve hours. Conclusions: The method allows to reproducibly induce and maintain three clinically relevant types of SVA observed in ventilated patients and may thus serve as a useful tool for future investigations on cellular and inflammatory effects of asynchrony.


  • Open Access

    Respiratory system mechanics in one-lung ventilation using double-lumen tubes

    by Jakob Wittenstein, Marcelo Gama de Abreu, Robert Huhle


  • Open Access

    Automatic Lung Segmentation and Quantification of Aeration in Computed Tomography of the Chest Using 3D Transfer Learning

    by Lorenzo Maiello, Lorenzo Ball, Marco Micali, Francesca Iannuzzi, Nico Scherf, Ralf-Thorsten Hoffmann, Marcelo Gama de Abreu, Paolo Pelosi, Robert Huhle

    Background: Identification of lung parenchyma on computer tomographic (CT) scans in the research setting is done semi-automatically and requires cumbersome manual correction. This is especially true in pathological conditions, hindering the clinical application of aeration compartment (AC) analysis. Deep learning based algorithms have lately been shown to be reliable and time-efficient in segmenting pathologic lungs. In this contribution, we thus propose a novel 3D transfer learning based approach to quantify lung volumes, aeration compartments and lung recruitability.Methods: Two convolutional neural networks developed for biomedical image segmentation (uNet), with different resolutions and fields of view, were implemented using Matlab. Training and evaluation was done on 180 scans of 18 pigs in experimental ARDS (u2NetPig) and on a clinical data set of 150 scans from 58 ICU patients with lung conditions varying from healthy, to COPD, to ARDS and COVID-19 (u2NetHuman). One manual segmentations (MS) was available for each scan, being a consensus by two experts. Transfer learning was then applied to train u2NetPig on the clinical data set generating u2NetTransfer. General segmentation quality was quantified using the Jaccard index (JI) and the Boundary Function score (BF). The slope between JI or BF and relative volume of non-aerated compartment (SJI and SBF, respectively) was calculated over data sets to assess robustness toward non-aerated lung regions. Additionally, the relative volume of ACs and lung volumes (LV) were compared between automatic and MS.Results: On the experimental data set, u2NetPig resulted in JI = 0.892 [0.88 : 091] (median [inter-quartile range]), BF = 0.995 [0.98 : 1.0] and slopes SJI = −0.2 {95% conf. int. −0.23 : −0.16} and SBF = −0.1 {−0.5 : −0.06}. u2NetHuman showed similar performance compared to u2NetPig in JI, BF but with reduced robustness SJI = −0.29 {−0.36 : −0.22} and SBF = −0.43 {−0.54 : −0.31}. Transfer learning improved overall JI = 0.92 [0.88 : 0.94], P < 0.001, but reduced robustness SJI = −0.46 {−0.52 : −0.40}, and affected neither BF = 0.96 [0.91 : 0.98] nor SBF = −0.48 {−0.59 : −0.36}. u2NetTransfer improved JI compared to u2NetHuman in segmenting healthy (P = 0.008), ARDS (P < 0.001) and COPD (P = 0.004) patients but not in COVID-19 patients (P = 0.298). ACs and LV determined using u2NetTransfer segmentations exhibited < 5% volume difference compared to MS.Conclusion: Compared to manual segmentations, automatic uNet based 3D lung segmentation provides acceptable quality for both clinical and scientific purposes in the quantification of lung volumes, aeration compartments, and recruitability.


  • Open Access

    Continuous external negative pressure improves oxygenation and respiratory mechanics in Experimental Lung Injury in Pigs – A pilot proof-of-concept trial

    by Martin Scharffenberg, Jakob Wittenstein, Moritz Herzog, Sebastian Tauer, Luigi Vivona, Raphael Theilen, Thomas Bluth, Thomas Kiss, Thea Koch, Giuseppe Fiorentino, et al.

    Background: Continuous external negative pressure (CENP) during positive pressure ventilation can recruit dependent lung regions. We hypothesised that CENP applied regionally to the thorax or the abdomen only, increases the caudal end-expiratory transpulmonary pressure depending on positive end-expiratory pressure (PEEP) in lung-injured pigs. Eight pigs were anesthetised and mechanically ventilated in the supine position. Pressure sensors were placed in the left pleural space, and a lung injury was induced by saline lung lavages. A CENP shell was placed at the abdomen and thorax (randomised order), and animals were ventilated with PEEP 15, 7 and zero cmH2O (15 min each). On each PEEP level, CENP of − 40, − 30, − 20, − 10 and 0 cmH2O was applied (3 min each). Respiratory and haemodynamic variables were recorded. Electrical impedance tomography allowed assessment of centre of ventilation. Results: Compared to positive pressure ventilation alone, the caudal transpulmonary pressure was significantly increased by CENP of ≤ 20 cmH2O at all PEEP levels. CENP of – 20 cmH2O reduced the mean airway pressure at zero PEEP (P = 0.025). The driving pressure decreased at CENP of ≤ 10 at PEEP of 0 and 7 cmH2O (P < 0.001 each) but increased at CENP of – 30 cmH2O during the highest PEEP (P = 0.001). CENP of – 30 cmH2O reduced the mechanical power during zero PEEP (P < 0.001). Both elastance (P < 0.001) and resistance (P < 0.001) were decreased at CENP ≤ 30 at PEEP of 0 and 7 cmH2O. Oxygenation increased at CENP of ≤ 20 at PEEP of 0 and 7 cmH2O (P < 0.001 each). Applying external negative pressure significantly shifted the centre of aeration towards dorsal lung regions irrespectively of the PEEP level. Cardiac output decreased significantly at CENP -20 cmH2O at all PEEP levels (P < 0.001). Effects on caudal transpulmonary pressure, elastance and cardiac output were more pronounced when CENP was applied to the abdomen compared with the thorax. Conclusions: In this lung injury model in pigs, CENP increased the end-expiratory caudal transpulmonary pressure. This lead to a shift of lung aeration towards dependent zones as well as improved respiratory mechanics and oxygenation, especially when CENP was applied to the abdomen as compared to the thorax. CENP values ≤ 20 cmH2O impaired the haemodynamics.


  • Open Access

    Variable ventilation improves pulmonary function and reduces lung damage without increasing bacterial translocation in a rat model of experimental pneumonia

    by Raquel F. de Magalhães, Cynthia S. Samary, Raquel S. Santos, Milena V. de Oliveira, Nazareth N. Rocha, Cintia L. Santos, Jamil Kitoko, Carlos A. M. Silva, Caroline L. Hildebrandt, Cassiano F. Goncalves-De-Albuquerque, et al.

    Variable ventilation has been shown to improve pulmonary function and reduce lung damage in different models of acute respiratory distress syndrome. Nevertheless, variable ventilation has not been tested during pneumonia. Theoretically, periodic increases in tidal volume (VT) and airway pressures might worsen the impairment of alveolar barrier function usually seen in pneumonia and could increase bacterial translocation into the bloodstream. We investigated the impact of variable ventilation on lung function and histologic damage, as well as markers of lung inflammation, epithelial and endothelial cell damage, and alveolar stress, and bacterial translocation in experimental pneumonia. Thirty-two Wistar rats were randomly assigned to receive intratracheal of Pseudomonas aeruginosa (PA) or saline (SAL) (n = 16/group). After 24-h, animals were anesthetized and ventilated for 2 h with either conventional volume-controlled (VCV) or variable volume-controlled ventilation (VV), with mean VT = 6 mL/kg, PEEP = 5cmH2O, and FiO2 = 0.4. During VV, tidal volume varied randomly with a coefficient of variation of 30% and a Gaussian distribution. Additional animals assigned to receive either PA or SAL (n = 8/group) were not ventilated (NV) to serve as controls. In both SAL and PA, VV improved oxygenation and lung elastance compared to VCV. In SAL, VV decreased interleukin (IL)-6 expression compared to VCV (median [interquartile range]: 1.3 [0.3–2.3] vs. 5.3 [3.6–7.0]; p = 0.02) and increased surfactant protein-D expression compared to NV (2.5 [1.9–3.5] vs. 1.2 [0.8–1.2]; p = 0.0005). In PA, compared to VCV, VV reduced perivascular edema (2.5 [2.0–3.75] vs. 6.0 [4.5–6.0]; p < 0.0001), septum neutrophils (2.0 [1.0–4.0] vs. 5.0 [3.3–6.0]; p = 0.0008), necrotizing vasculitis (3.0 [2.0–5.5] vs. 6.0 [6.0–6.0]; p = 0.0003), and ultrastructural lung damage scores (16 [14–17] vs. 24 [14–27], p < 0.0001). Blood colony-forming-unit (CFU) counts were comparable (7 [0–28] vs. 6 [0–26], p = 0.77). Compared to NV, VCV, but not VV, increased expression amphiregulin, IL-6, and cytokine-induced neutrophil chemoattractant (CINC)-1 (2.1 [1.6–2.5] vs. 0.9 [0.7–1.2], p = 0.025; 12.3 [7.9–22.0] vs. 0.8 [0.6–1.9], p = 0.006; and 4.4 [2.9–5.6] vs. 0.9 [0.8–1.4], p = 0.003, respectively). Angiopoietin-2 expression was lower in VV compared to NV animals (0.5 [0.3–0.8] vs. 1.3 [1.0–1.5], p = 0.01). In this rat model of pneumonia, VV improved pulmonary function and reduced lung damage as compared to VCV, without increasing bacterial translocation.


  • Assessing the eligibility of a non-invasive continuous blood pressure measurement technique for application during total intravenous anaesthesia

    by Robert Huhle, Joachim Siegert, Fred Wonka, Christoph Schindler, Marcelo Gama de Abreu, Thea Koch, Ute Morgenstern, Herman Theilen

    Objective: To assess the eligibility for replacement of invasive blood pressure as measured “within” the arterial vessel (IBP) with non-invasive continuous arterial blood pressure (cNIP) monitoring during total intravenous anaesthesia (TIVA), the ability of cNiP to track fast blood pressure changes needs to be quantified. A new method of statistical data analysis is developed for this purpose.Methods: In a pilot study on patients undergoing neurosurgical anaesthesia, mean arterial pressure MAPIBP measured with IBP was compared to MAPCNP measured by the CNAP Monitor 500 in ten patients (age: 63±13 a). Correlation analysis of changes of device differences ΔeMAP=ΔMAPCNP-ΔMAPIBP with changes of MAPIBP (ΔMAPIBP) during intervals of vasoactivity was conducted. An innovative technique, of linear trend analysis (LTA) applied to two signals, is described to perform this analysis without a priori knowledge of intervals of vasoactivity.Results: Analysis of ΔeMAP during vasoactivity revealed that ΔMAPCNP systematically underestimated ΔMAPIBP by 37%. This was confirmed in the complete data set using LTA technique showing a systematic, yet patient specific, underestimation in tracking ΔMAPIBP (16…120%).Conclusion: The proposed LTA technique is able to detect systematic errors in tracking short-term blood pressure changes otherwise masked by established analysis. LTA may thus be a useful tool to assess the eligibility of cNIP to replace IBP during TIVA.

  • Anti Stress App

    by Hagen Malberg, Liudmilla Ziaziulchyk, Max Braer, Martin Hoffmann, Aline Mittag, Robert Huhle, Sebastian Zaunseder, Hendrik Bonnemeier, Andreas Heinig, Wolf-Joachim Fischer