Paul Perito
Research Subjects
Paul Perito has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Alfredo Suarez-Sarmiento
Perito Urology, Coral Gables, USA
3 shared publications- Abrar Mian
Mayo Clinic Rochester, Department of Urology, Rochester, MN, USA
2 shared publications - Daniar Osmonov
Department of Urology, University Medical Center Schleswig-Holstein, Campus Lübeck, Germany
2 shared publications - Ettore De Berardinis
Department of Maternal-Infant and Urological Sciences, “Sapienza” University of Rome, Umberto I Hospital, 00185 Rome, Italy
2 shared publications - Francesco Del Giudice
Department of Engineering, University of Basilicata, Ateneo Lucano Avenue 10, 85100 Potenza, Italy
2 shared publications - Gabriele Antonini
Rome, Italy
2 shared publications
Latest Publications
- 13 October 2026
- Published by Springer Nature in International Journal Of Impotence Research
- p. 1-4
Top ten surgical tricks: infrapubic inflatable penile prothesis implantation
The infrapubic penile prosthesis implantation approach represents a surgical variant to the traditional penoscrotal approach, characterized by a distinctive incision site used to maintain excellent surgical exposure for a penile prosthesis implantation. Its peculiar features include short operative time, minimally invasive nature, low-reported infection rate, and a direct line of sight for reservoir placement; its specific technical challenges include preservation of the dorsal neurovascular bundle, a restricted working space, and a non-negligible learning curve. In the present manuscript, we describe ten surgical tips covering patient selection and positioning, incision placement, fascial dissection, corporotomy and corporal dilation, reservoir dissection and placement, scrotal pump positioning, hemostasis and drain management, intra-operative device testing, tubing routing, and postoperative care. Each tip is supported, where available, by published evidence and is otherwise drawn from surgical experience.
- 13 October 2026
- Published by Springer Nature in International Journal Of Impotence Research
- p. 1-4
Top ten surgical tricks: infrapubic inflatable penile prothesis implantation
The infrapubic penile prosthesis implantation approach represents a surgical variant to the traditional penoscrotal approach, characterized by a distinctive incision site used to maintain excellent surgical exposure for a penile prosthesis implantation. Its peculiar features include short operative time, minimally invasive nature, low-reported infection rate, and a direct line of sight for reservoir placement; its specific technical challenges include preservation of the dorsal neurovascular bundle, a restricted working space, and a non-negligible learning curve. In the present manuscript, we describe ten surgical tips covering patient selection and positioning, incision placement, fascial dissection, corporotomy and corporal dilation, reservoir dissection and placement, scrotal pump positioning, hemostasis and drain management, intra-operative device testing, tubing routing, and postoperative care. Each tip is supported, where available, by published evidence and is otherwise drawn from surgical experience.
- 9 August 2025
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 38 (8) , 580-584
Mechanical failure of inflatable penile prostheses: a 2025 snapshot and historical context
- 9 August 2025
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 38 (8) , 580-584
Mechanical failure of inflatable penile prostheses: a 2025 snapshot and historical context
- 5 March 2024
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 37 (1) , 72-75
Glans hypermobility scale (GHS): A simple grading scale and description of a modified glanspexy technique
Glans hypermobility (GH) is a well-described clinical entity that can have significant implications for cosmesis and function, resulting in sexual dissatisfaction, penile pain, and early device erosion, with an estimated incidence of 0.04% to 10%. We developed a novel grading scale to assess GH severity intraoperatively during primary inflatable penile prosthesis (IPP) placement and describe a modified glanspexy technique to correct GH when encountered during IPP placement. 530 patients who underwent primary IPP placements from two high-volume prosthetic surgeons between February 2018 – November 2019 were retrospectively reviewed in order to identify the incidence of GH. Of these, 139 (26.2%) had hypermobility. Employing our new scaling system, grade 1, 2, and 3 GH was seen in 86 (16.2%), 29 (5.5%), and 24 (4.5%) cases, respectively. Increased implant size correlated with a decreased likelihood of GH incidence. Each increase in implant size by 1 cm decreased the incidence of detecting GH by 11.0% (OR = 0.89; p = 0.015). 11 patients underwent primary GH repair using our described technique. At one-year follow-up, one patient required repeat glanspexy for recurrent bothersome GH and a second patient developed a suture granuloma at the glanspexy incision requiring unilateral cylinder explant. Our modified glanspexy technique can be used to correct GH in any direction and is a useful tool for the prosthetic surgeon’s armamentarium.
- 5 March 2024
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 37 (1) , 72-75
Glans hypermobility scale (GHS): A simple grading scale and description of a modified glanspexy technique
Glans hypermobility (GH) is a well-described clinical entity that can have significant implications for cosmesis and function, resulting in sexual dissatisfaction, penile pain, and early device erosion, with an estimated incidence of 0.04% to 10%. We developed a novel grading scale to assess GH severity intraoperatively during primary inflatable penile prosthesis (IPP) placement and describe a modified glanspexy technique to correct GH when encountered during IPP placement. 530 patients who underwent primary IPP placements from two high-volume prosthetic surgeons between February 2018 – November 2019 were retrospectively reviewed in order to identify the incidence of GH. Of these, 139 (26.2%) had hypermobility. Employing our new scaling system, grade 1, 2, and 3 GH was seen in 86 (16.2%), 29 (5.5%), and 24 (4.5%) cases, respectively. Increased implant size correlated with a decreased likelihood of GH incidence. Each increase in implant size by 1 cm decreased the incidence of detecting GH by 11.0% (OR = 0.89; p = 0.015). 11 patients underwent primary GH repair using our described technique. At one-year follow-up, one patient required repeat glanspexy for recurrent bothersome GH and a second patient developed a suture granuloma at the glanspexy incision requiring unilateral cylinder explant. Our modified glanspexy technique can be used to correct GH in any direction and is a useful tool for the prosthetic surgeon’s armamentarium.
- Open Access
- 29 September 2023
- Published by Springer Nature in Research Square
Glans Hypermobility Scale (GHS) Score: a Simple and Reliable Grading Scale for Glanular Hypermobility.
Glans hypermobility (GH) is a well-described clinical entity that can have significant implications for cosmesis and function, resulting in sexual dissatisfaction, penile pain, and early device erosion, with an estimated incidence of 0.04–10%. We developed a novel grading scale to assess GH severity intraoperatively during primary inflatable penile prosthesis (IPP) placement and describe a modified glanspexy technique to correct GH when encountered during IPP placement. A total of 530 patients underwent primary device implantation. Of these, 139 (26%) had hypermobility. Employing our new scaling system, grade 1, 2, and 3 GH was seen in 86 (16%), 29 (5.5%), and 24 (4.5%) cases, respectively. Increased implant size correlated with decreased likelihood of GH incidence. Each increase in implant size by 1 cm decreased the incidence of detecting GH by 11% (OR = 0.89; p = 0.015). 11 patients underwent primary GH repair using our described technique. At one-year follow-up, one patient required repeat glanspexy for recurrent bothersome GH and a second patient developed a suture granuloma at the glanspexy incision requiring unilateral cylinder explant. Our modified glanspexy technique can be used to correct GH in any direction and is a useful tool for the prosthetic surgeon’s armamentarium.
- 29 September 2023
- Published by Springer Nature in Research Square
Open AccessGlans Hypermobility Scale (GHS) Score: a Simple and Reliable Grading Scale for Glanular Hypermobility.
Glans hypermobility (GH) is a well-described clinical entity that can have significant implications for cosmesis and function, resulting in sexual dissatisfaction, penile pain, and early device erosion, with an estimated incidence of 0.04–10%. We developed a novel grading scale to assess GH severity intraoperatively during primary inflatable penile prosthesis (IPP) placement and describe a modified glanspexy technique to correct GH when encountered during IPP placement. A total of 530 patients underwent primary device implantation. Of these, 139 (26%) had hypermobility. Employing our new scaling system, grade 1, 2, and 3 GH was seen in 86 (16%), 29 (5.5%), and 24 (4.5%) cases, respectively. Increased implant size correlated with decreased likelihood of GH incidence. Each increase in implant size by 1 cm decreased the incidence of detecting GH by 11% (OR = 0.89; p = 0.015). 11 patients underwent primary GH repair using our described technique. At one-year follow-up, one patient required repeat glanspexy for recurrent bothersome GH and a second patient developed a suture granuloma at the glanspexy incision requiring unilateral cylinder explant. Our modified glanspexy technique can be used to correct GH in any direction and is a useful tool for the prosthetic surgeon’s armamentarium.
- 8 August 2022
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 35 (6) , 564-568
Satisfaction rates of inflatable penile prosthesis in men who have sex with men are high
Men with erectile dysfunction (ED) have high patient satisfaction after placement of inflatable penile prostheses (IPP). The impact on satisfaction and quality of life has never been studied in men who have sex with men (MSM). This study sought to assess the satisfaction rates and quality of life of MSM after placement of IPP for ED. This study was a multi-institutional, retrospective study that enrolled adult men who self-identified as MSM and underwent IPP placement. Two questionnaires were administered at one time point post-operatively, the Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS), and the Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire. Results of these questionnaires were analyzed with descriptive statistics. Forty-nine MSM were assessed retrospectively with median age of 62 years with average follow-up of 15.2 months. Median EDITS score was 93.2/100 (range, 70.5–100). Median overall QoLSPP score was 72/80 (58–79), with median scores of 22/25 (16–25), 19/20 (13–20), 18/20 (12–20), and 14/15 (9–15), for the functional, personal, relational, and social domains respectively. Overall, MSM report high satisfaction rates and quality of life after IPP placement. A better understanding of the needs and demands of this patient population may lead to improved patient satisfaction and quality of life.
- 8 August 2022
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 35 (6) , 564-568
Satisfaction rates of inflatable penile prosthesis in men who have sex with men are high
Men with erectile dysfunction (ED) have high patient satisfaction after placement of inflatable penile prostheses (IPP). The impact on satisfaction and quality of life has never been studied in men who have sex with men (MSM). This study sought to assess the satisfaction rates and quality of life of MSM after placement of IPP for ED. This study was a multi-institutional, retrospective study that enrolled adult men who self-identified as MSM and underwent IPP placement. Two questionnaires were administered at one time point post-operatively, the Erectile Dysfunction Inventory of Treatment Satisfaction (EDITS), and the Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire. Results of these questionnaires were analyzed with descriptive statistics. Forty-nine MSM were assessed retrospectively with median age of 62 years with average follow-up of 15.2 months. Median EDITS score was 93.2/100 (range, 70.5–100). Median overall QoLSPP score was 72/80 (58–79), with median scores of 22/25 (16–25), 19/20 (13–20), 18/20 (12–20), and 14/15 (9–15), for the functional, personal, relational, and social domains respectively. Overall, MSM report high satisfaction rates and quality of life after IPP placement. A better understanding of the needs and demands of this patient population may lead to improved patient satisfaction and quality of life.
- 27 June 2022
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 35 (6) , 539-543
Analysis of the effects of different surgical approaches on corporotomy localization in inflatable penile implant surgery performed by expert implant surgeons
Inflatable penile prostheses may be a solution for patients with erectile dysfunction. To our knowledge, no data exist regarding the effect of different surgical approaches used during implantation on the site of the corporotomy. The main purpose of this multicentre study was to investigate the influence of different surgical approaches on the corporotomy site. Data were collected from six expert implant surgeons. Surgical notes were searched for the incision site, proximal, distal and total corporal length measurement, total cylinder length, length of rear tip extenders, surgery time, type of implant, and reservoir placement. The association between the proximal/distal corporal length and the recorded covariates was examined using a linear mixed model. A total of 1757 patients who underwent virgin prosthesis implantation were included in the analysis. Analysis of proximal/distal measurements was performed on 1709 patients. The proximal/distal ratio had a mean of 0.8 ± 0.3 in penoscrotal incisions (n = 391), 0.7 ± 0.2 in infrapubic incisions (n = 832) and 0.7 ± 0.2 in subcoronal (n = 486) incisions. We observed no significant differences in proximal/distal measurements between the highest-volume surgeons. We could not draw a firm conclusion about the difference in corporotomy site between different surgical approaches, but we found no significant difference between the highest-volume surgeons using different techniques.
- 27 June 2022
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 35 (6) , 539-543
Analysis of the effects of different surgical approaches on corporotomy localization in inflatable penile implant surgery performed by expert implant surgeons
Inflatable penile prostheses may be a solution for patients with erectile dysfunction. To our knowledge, no data exist regarding the effect of different surgical approaches used during implantation on the site of the corporotomy. The main purpose of this multicentre study was to investigate the influence of different surgical approaches on the corporotomy site. Data were collected from six expert implant surgeons. Surgical notes were searched for the incision site, proximal, distal and total corporal length measurement, total cylinder length, length of rear tip extenders, surgery time, type of implant, and reservoir placement. The association between the proximal/distal corporal length and the recorded covariates was examined using a linear mixed model. A total of 1757 patients who underwent virgin prosthesis implantation were included in the analysis. Analysis of proximal/distal measurements was performed on 1709 patients. The proximal/distal ratio had a mean of 0.8 ± 0.3 in penoscrotal incisions (n = 391), 0.7 ± 0.2 in infrapubic incisions (n = 832) and 0.7 ± 0.2 in subcoronal (n = 486) incisions. We observed no significant differences in proximal/distal measurements between the highest-volume surgeons. We could not draw a firm conclusion about the difference in corporotomy site between different surgical approaches, but we found no significant difference between the highest-volume surgeons using different techniques.
- 18 December 2020
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 34 (6) , 524-533
Nuances of infrapubic incision for inflatable penile prosthesis
This workshop completes the trilogy of nuances of the various incisions used to place an inflatable penile prosthesis (IPP). Infrapubic placement was the original technique employed 50 years ago for the very first IPP surgeries. The historical perspective of the development of implantation incisions and the original Scott prosthesis highlighted in this work should be fascinating to today’s younger prosthetic urologists. The developing surgeon should also find some surprising maneuvers considered important technique nuances from the highest volume infrapubic implanter in the world. Among the wonders of the infrapubic approach covered are: The surgery is conducted without the aid of an in-dwelling Foley catheter or post-operative inflation. Hydrodistension of the corpora substitutes for corporal dilatation. The “chicken choke” protects the urethra from damage. Closed suction drainage is employed despite minimal scrotal dissection. Motivated patients may use their new device as early as 14 days after implantation.
- 18 December 2020
- Published by Springer Nature in International Journal Of Impotence Research
- Vol. 34 (6) , 524-533
Nuances of infrapubic incision for inflatable penile prosthesis
This workshop completes the trilogy of nuances of the various incisions used to place an inflatable penile prosthesis (IPP). Infrapubic placement was the original technique employed 50 years ago for the very first IPP surgeries. The historical perspective of the development of implantation incisions and the original Scott prosthesis highlighted in this work should be fascinating to today’s younger prosthetic urologists. The developing surgeon should also find some surprising maneuvers considered important technique nuances from the highest volume infrapubic implanter in the world. Among the wonders of the infrapubic approach covered are: The surgery is conducted without the aid of an in-dwelling Foley catheter or post-operative inflation. Hydrodistension of the corpora substitutes for corporal dilatation. The “chicken choke” protects the urethra from damage. Closed suction drainage is employed despite minimal scrotal dissection. Motivated patients may use their new device as early as 14 days after implantation.
- 9 October 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (9) , e3323
Closed suction drainage (CSD) versus no drainage of the scrotum in inflatable penile prosthesis (IPP) placement with minimally invasive infrapubic approach: Retrospective comparative outcomes at two high-volume implanting centers
- 9 October 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (9) , e3323
Closed suction drainage (CSD) versus no drainage of the scrotum in inflatable penile prosthesis (IPP) placement with minimally invasive infrapubic approach: Retrospective comparative outcomes at two high-volume implanting centers
- 15 March 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (1) , e448-e449
Postoperative vacuum therapy following AMS™ LGX 700® inflatable penile prosthesis placement: Penile dimension outcomes and overall satisfaction
- 15 March 2019
- Published by Elsevier in European Urology Supplements
- Vol. 18 (1) , e448-e449
Postoperative vacuum therapy following AMS™ LGX 700® inflatable penile prosthesis placement: Penile dimension outcomes and overall satisfaction