KAKoki Abe

Koki Abe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Koki Abe has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Acute asymptomatic pulmonary thromboembolism detected using dynamic digital radiography following total hip arthroplasty: A case report

    by Yuta Hieda, Kazuma Miyatake, Hyonmin Choe, Koki Abe, Yutaka Inaba

    Background: Acute pulmonary thromboembolism is a serious complication of total hip arthroplasty that may be asymptomatic, underscoring the importance of early detection. Contrast-enhanced computed tomography is the standard diagnostic modality; however, its use is limited by its invasiveness, radiation exposure, contrast allergy, and renal dysfunction. Dynamic digital radiography is a novel, minimally invasive imaging technique that enables visualisation of pulmonary perfusion without contrast agents. Case summary: We report a case of a 58-year-old woman who underwent primary total hip arthroplasty. Postoperatively, the patient remained asymptomatic. One week after total hip arthroplasty, follow-up dynamic digital radiography demonstrated newly-developed pulmonary perfusion abnormalities, with marked signal reduction in the right middle and lower lung zones, and a mild reduction in the left upper lung zone. Subsequent contrast-enhanced computed tomography confirmed bilateral pulmonary thromboembolism corresponding to perfusion defects detected using dynamic digital radiography. Anticoagulant therapy completely resolved the thromboembolism. Discussion: This case highlights the potential utility of dynamic digital radiography for early detection of asymptomatic acute pulmonary thromboembolism following total hip arthroplasty.

  • Open Access

    A novel in vitro experimental design for biomechanical testing of patellofemoral joint kinetics and kinematics

    by A. Mounir Boudali, Jobe Shatrov, Koki Abe, Marcus Zavala, David Parker, William L. Walter, Elizabeth Clarke

    Introduction: Complications arising from the patellofemoral joint (PFJ) represent the third most common cause for revision in total knee arthroplasty (TKA). Previous in vitro biomechanical studies have altered the native attachments of muscles controlling the PFJ. The purpose of this study was to design an in vitro biomechanical setup that would allow testing of both native and arthroplasty knee joints, specifically the PFJ, without disturbing the native attachments of the quadriceps and hamstrings muscles. Methods: After finalising a prototype, a pelvis-to-toe human cadaver specimen was tested. The simVITRO platform was used to simulate movement and control force trajectories. A motion capture system was used to capture the motion of the bones and to measure knee flexion angle and patellar movement with respect to the femur. The forces applied in the PFJ were measured using a custom patella sensor. Results: Displacement of the reflective cluster attached to the femur was measured during compression loading at different flexion angles, passive flexion and stairs descent trajectory. The femur showed less than 1 mm and 3 mm displacement with respect to the femur clamp in passive flexion and stairs descent. The most translation of 8.37 mm (Conclusion: This novel design provides a methodology for studying the biomechanics of the PFJ in vitro that preserves the soft tissues influencing the behaviour of the joint. This setup provides a biomechanics model that can be utilised to better understand and study the PFJ in vitro.


  • Open Access

    Evaluation of the Diagnostic Accuracy of Serum Albumin and Globulin in Pyogenic Spondylitis

    by Hideo Mitsui, Hyonmin Choe, Masashi Shimoda, Hironori Yamane, Yuta Hieda, Koki Abe, Yohei Ito, Hiroyuki Ike, Ken Kumagai, Naomi Kobayashi, et al.

    Background: Serum markers are commonly used to diagnose bone and joint infections; however, their accuracy for diagnosing pyogenic spondylitis remains unproven. This study aimed to validate the diagnostic accuracy of inflammatory, nutritional, and immunological serum markers for spinal infections and identify the most effective combinations. Methods: The retrospective cohort study analyzed 656 patients who visited the hospital for spinal diseases between 1 January 2004 and 31 March 2021; a total of 76 were diagnosed with pyogenic spondylitis. Blood samples were analyzed for serum albumin (Alb), total protein (TP), globulin (Glb), C-reactive protein (CRP), platelet count, white blood cell count, neutrophil count, lymphocyte count, and monocyte count. Combination markers, including albumin–globulin ratio (AGR), CRP–albumin ratio (CAR), CRP–AGR (CAGR), neutrophil–lymphocyte ratio (NLR), and platelet–lymphocyte ratio (PLR), were also evaluated. Receiver operating characteristic curves were used to determine each marker’s diagnostic performance. Furthermore, multivariate analysis was performed to examine the odds ratios. Results: Patients with pyogenic spondylitis showed significantly different levels in Alb (p < 0.0001), Glb (p < 0.0001), CRP (p < 0.0001), platelet count (p < 0.0001), WBC count (p < 0.0006), neutrophil count (p = 0.0019), lymphocyte count (p = 0.0085), AGR (p < 0.0001), CAR (p < 0.0001), CAGR (p < 0.0001), NLR (p < 0.0001), and PLR (p < 0.0001). CRP (AUC = 0.80) showed good diagnostic accuracy, while combination markers CAR (AUC = 0.82) and CAGR (AUC = 0.83) had the highest areas under the curve (AUC). Multivariate analysis indicated that decreased age and the presence of comorbidities (including chronic kidney disease, chronic liver disease, malignancy, or diabetes), were independent predictors of early pyogenic spondylitis (OR_age = 0.93, OR_comorbidities = 16.98, p_age = 0.0005, and p_comorbidities = 0.0001). In patients with low-inflammatory pyogenic spondylitis, significant differences were observed in TP (p = 0.0293), Glb (p = 0.0012), CRP (p = 0.0023), platelet count (p = 0.0108), AGR (p = 0.0044), CAR (p = 0.0006), CAGR (p = 0.0004), PLR (p = 0.0192), and NLR (p = 0.0027), with CAGR showing the highest AUC (AUC = 0.70) among them. Conclusions: Serum combination markers (AGR, CAGR, CAR, PLR, and NLR) showed diagnostic value for pyogenic spondylitis, with CAGR achieving the highest accuracy. In low-inflammatory pyogenic spondylitis patients (CRP ≤ 1.0 mg/dL), these markers may aid diagnosis.


  • Bead‐beating assay during synovial fluid DNA extraction improves real‐time PCR accuracy for periprosthetic joint infection

    by Yuta Hieda, Hyonmin Choe, Hiroyuki Ike, Koki Abe, Ken Kumagai, Masanobu Takeyama, Yusuke Kawabata, Naomi Kobayashi, Yutaka Inaba

    Polymerase chain reaction (PCR)-based genetic diagnosis is a rapid and sensitive method to diagnose periprosthetic joint infection (PJI). DNA extraction using bead beating is an effective method for collecting bacterial genes in Gram-positive bacteria. We compared the detection accuracy between the conventional and bead-beating DNA extraction assay. The detection rate improved from 86.7% using the conventional method to 95.6% using the bead-beating. Our results suggest that bead-beating during DNA extraction can improve the accuracy of PCR-based genetic diagnosis of PJI.


  • Open Access

    Targeting of Periprosthetic Muscles for the Ultrasonographic Screening of Hip Abnormalities in Hip Resurfacing Arthroplasty Patients

    by Hyonmin Choe, Naomi Kobayashi, Koki Abe, Yuta Hieda, Hiroyuki Ike, Ken Kumagai, Kazuma Miyatake, Takahiro Fujisawa, Yutaka Inaba

    Background: Hip resurfacing arthroplasty (HRA) patients require subsequent annual screening for postoperative complications. Ultrasonography may be useful for this purpose but lacks a screening protocol for hips. The purpose of this study was to evaluate the accuracy of ultrasonography for detecting postoperative complications in HRA patients using a screening protocol that specifically targets periprosthetic muscles. Methods: We enrolled 45 hips from 40 HRA patients with a mean follow-up period of 8.2 years. MRI and ultrasonography scans were simultaneously conducted at follow-up. The ultrasonography assessments were conducted on the anterior part of the hip that targets iliopsoas, sartorius, rectus femoris, lateral with anterior superior and inferior iliac spine (ASIS and AIIS) as bony landmarks, and the lateral and posterior parts that target fascia tensor, short rotators, and gluteus minimus, medius, and maximus with greater trochanter and ischial tuberosity as bony landmarks. The accuracy of diagnosing postoperative abnormalities and the visibility of periprosthetic muscles were compared between these two modalities. Results: Both MRI and ultrasonography detected an abnormal region in eight cases comprising two infections, two pseudotumors, and four patients with greater trochanteric bursitis. Among these cases, four hips required implant removal. The increase in anterior space, measured as the distance between the iliopsoas and resurfacing head, was a good indicator for the abnormal mass in these four HRA cases. In the assessment of periprosthetic muscles, MRI showed a much lower visibility than ultrasonography in the iliopsoas (6.7% vs. 100%), gluteus minimus (6.7% vs. 88.9%), and short rotators (8.8% vs. 71.4%) due to implant halation. Conclusions: By targeting periprosthetic muscles, ultrasonography can detect postoperative complications as effectively as MRI assessments in HRA patients. Ultrasonography has superior visibility in the periprosthetic muscles of HRA patients, indicating its utility for the screening of small legions in these cases which may not be visible by MRI.


  • Accuracy of Computer Navigation–Assisted Arthroscopic Osteochondroplasty for Cam-Type Femoroacetabular Impingement Using the Model-to-Image Registration Method

    by Koki Abe, Masatoshi Oba, Naomi Kobayashi, Shota Higashihira, Hyonmin Choe, Taro Tezuka, Hiroyuki Ike, Yutaka Inaba

    Background: Precise osteochondroplasty is important in arthroscopic hip surgery for cam-type femoroacetabular impingement (FAI). Although computer-assisted surgery with a navigation system may enhance the accuracy of arthroscopic osteochondroplasty, few clinical studies have assessed its accuracy. Purpose: To evaluate the accuracy of arthroscopic osteochondroplasty by a computed tomography (CT)–based navigation system for cam-type FAI, using 3-dimensional (3D) reconstruction with more detail compared with previous methods. Study design: Case series; Level of evidence, 4. Methods: Twenty patients (14 men and 6 women) who underwent navigation-assisted arthroscopic surgery for cam-type FAI were included. The preoperative 3D model of the femur was constructed from each patient’s CT data, and a planned model with virtual cam resection was generated. A femoral model was reconstructed from CT data postoperatively. The 3 models for each patient were overlaid using a 3D model registration method. Then, the contours of the bone resection area of each model were compared by measuring them. To measure the deviation between planned and actual bone resections, 4 cross-sectional images of the 3 femoral models were set at one-quarter intervals from the femoral head radius. All measurements were based on clockface lines set around the femoral neck axis at 30-minute intervals. Differences between the planned and postoperative contour lines were deemed resection deviations. Results: All cam resections were performed in the anterior half of the region of interest. Therefore, only the anterior half (48 points) of the 96 points per case were analyzed. In 876 (91.3%) points of the total measurement points (960 points/20 cases), the error in resection depth was within 3 mm. Overresection was observed at 35 (3.6%) points and underresection at 49 (5.1%) points. The observed maximum deviations from the planned models were 6.3 mm overresection and –7.1 mm underresection. The alpha angles of the postoperative model at the posterior 9- to 3-o’clock position were <55° in all patients. Conclusion: Navigation-assisted arthroscopic osteochondroplasty showed favorable accuracy. Underresection was more frequent than overresection on the anterosuperior side of the femur, despite assistance of the navigation system.


  • Application of Ultrasonography During Sternocleidomastoid Muscle Release for Congenital Muscular Torticollis

    by Hyonmin Choe, Naomi Kobayashi, Masatoshi Oba, Akira Morita, Koki Abe, Yutaka Inaba

    Case: We report a 4-year-old girl with congenital muscular torticollis (CMT) who was treated with sternocleidomastoid muscle (SCM) tenotomy using ultrasonography (US). Prior to the surgery, US was utilized to identify the clavicle and sternum branches of the SCM, sternohyoid muscles, internal jugular vein, and common carotid artery. Then, local anesthesia was injected into the layer between the fascial sheath of the SCM and carotid sheath to reduce bleeding and avoid vascular injury. During surgery, the SCM dissection was carefully conducted under US guidance to avoid vascular injury. No residual of SCM dissection and improvement of neck motion were confirmed before the skin closure. Postoperative course was good with no obvious complications in this patient. Conclusion: The intraoperative US investigation during SCM tenotomy is a useful procedure that provides vital information about dissection area of SCM and orientation of internal jugular vein that reduces the risk of insufficient tenotomy and vascular injury.

  • An automated real‐time PCR assay for synovial fluid improves the preoperative etiological diagnosis of periprosthetic joint infection and septic arthritis

    by Fan Yang, Hyonmin Choe, Naomi Kobayashi, Taro Tezuka, Masatoshi Oba, Yushi Miyamae, Akira Morita, Koki Abe, Yutaka Inaba

    Synovial fluid is important for the preoperative etiological diagnosis of suspected periprosthetic joint infection (PJI) or septic arthritis (SA). GENECUBE, an automated real‐time polymerase chain reaction (PCR) assay, was used to detect bacterial mecA (methicillin resistance) and was compared with microbiological cultures for preoperatively diagnosing PJI and SA in 74 patients suspected of these infections and thus earmarked for surgery. PJI and SA were diagnosed in 21 and 6 cases, respectively, using modified ICM 2018 diagnostic criteria. Microbiological cultures determined methicillin‐resistant staphylococcus (MRS) as the causative organism in six samples, which were all positive in the GENECUBE assay. Significantly also, the GENECUBE assay detected six MRS infections in culture‐negative but infection‐diagnosed patients, and in one inconclusive case, suggesting a higher sensitivity of this assay. Compared with microbiological culture, the sensitivity and specificity of the GENECUBE assay for mecAwas 100% and 92.2%, respectively. However, GENECUBE also produced invalid results in three cases, suggesting possible PCR inhibitors in the synovial fluid samples. We additionally validated the accuracy of pan‐bacterial real‐time PCR targeting 16S rRNA and other tests. Pan‐bacterial real‐time PCR was as effective as preoperative bacterial culture testing, although the α‐defensin assay had the highest sensitivity at 100%. Hence, fully automated real‐time PCR targeting of the bacterial mecA gene improves the etiological diagnosis of PJI and SA by reducing the testing time and lowering the false‐positive detection rates. A screening approach for α‐defensin followed by bacterial mecA gene testing in synovial fluids is therefore a more efficient method of preoperatively diagnosing PJI and SA.


  • Translational regulation by miR-301b upregulates AMP deaminase in diabetic hearts

    by Yuki Tatekoshi, Masaya Tanno, Hidemichi Kouzu, Koki Abe, Takayuki Miki, Atsushi Kuno, Toshiyuki Yano, Satoko Ishikawa, Wataru Ohwada, Tatsuya Sato, et al.