Liset de la Fuente Rosales
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liset de la Fuente Rosales has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alexis Dimitriadis
1 shared publicationCheolha Baek
1 shared publication- Donghee Han
Department of Radiological Science, Kangwon National University, Samcheok, Republic of Korea
1 shared publication - Godfrey Azangwe
International Atomic Energy Agency, Department of Nuclear Sciences and Applications, Division of Human Health, Vienna, Austria
1 shared publication - Hans Rabus
Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
1 shared publication - J. Rahm
Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
Monte Carlo Simulation and Experimental Validation of Holder Correction Factors for Postal Dosimetry Audits
This study determined the holder correction factors (HCFs) for the new electron-holder to assess its use for photon beams within the IAEA/WHO postal dosimetry audits. MC simulations were used for photon beam qualities (6-18 MV), and were experimentally validated. MC simulations were first validated for the legacy photon-holder. The HCFs from the simulations ranged from 1.001 to 1.005 with the largest uncertainty of 0.24%. The experimentally validated HCFs ranged from 1.002 to 1.007 with uncertainties reaching up to 0.12%. This supports the adoption of a single, universal holder for photon and electron dosimetry audits, offering potential benefits in operational efficiency.
- 2 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMonte Carlo Simulation and Experimental Validation of Holder Correction Factors for Postal Dosimetry Audits
This study determined the holder correction factors (HCFs) for the new electron-holder to assess its use for photon beams within the IAEA/WHO postal dosimetry audits. MC simulations were used for photon beam qualities (6-18 MV), and were experimentally validated. MC simulations were first validated for the legacy photon-holder. The HCFs from the simulations ranged from 1.001 to 1.005 with the largest uncertainty of 0.24%. The experimentally validated HCFs ranged from 1.002 to 1.007 with uncertainties reaching up to 0.12%. This supports the adoption of a single, universal holder for photon and electron dosimetry audits, offering potential benefits in operational efficiency.
- 18 December 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (6) , 062418
Stopping power of water for carbon ions with energies in the Bragg peak region
The stopping power of liquid water was measured for carbon ions with energies in the Bragg peak region using the inverted Doppler shift attenuation method. Among the semiempirical data, the results of this work agree best with the data recommended in the Errata and Addendum of ICRU Report No. 73, which is based on an value of 78 eV for water. The agreement was worse when the present results were compared to the newer recommendation of the ICRU published in ICRU Report No. 90. The srim code seems to slightly overestimate the stopping power of water for carbon ions above 3 MeV. A semiexperimental stopping power of water for α particles was derived from the present results using the theoretical ratio between the stopping powers of water for carbon ions and α particles computed by means of the casp code. These values agree well with the experimental data for α particles within the uncertainties.- 18 December 2020
- Published by American Physical Society (APS) in Physical Review E
- Vol. 102 (6) , 062418
Stopping power of water for carbon ions with energies in the Bragg peak region
The stopping power of liquid water was measured for carbon ions with energies in the Bragg peak region using the inverted Doppler shift attenuation method. Among the semiempirical data, the results of this work agree best with the data recommended in the Errata and Addendum of ICRU Report No. 73, which is based on an value of 78 eV for water. The agreement was worse when the present results were compared to the newer recommendation of the ICRU published in ICRU Report No. 90. The srim code seems to slightly overestimate the stopping power of water for carbon ions above 3 MeV. A semiexperimental stopping power of water for α particles was derived from the present results using the theoretical ratio between the stopping powers of water for carbon ions and α particles computed by means of the casp code. These values agree well with the experimental data for α particles within the uncertainties.