Yifan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yifan Huang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Jiandong Yang
5 shared publicationsZhigao Zhao
5 shared publicationsWeijia Yang
4 shared publicationsJiebin Yang
State Key Laboratory of Water Resources and Hydropower Engineering Science Wuhan University Wuhan People's Republic of China
3 shared publicationsWeichao Ma
2 shared publicationsChengpeng Liu
State Key Laboratory of Water Resources and Hydropower Engineering Science Wuhan University Wuhan People's Republic of China
1 shared publication
Latest Publications
- 28 October 2026
- Published by Elsevier in Water Research
- Vol. 309
State estimation under operational uncertainty in water distribution systems
- 28 October 2026
- Published by Elsevier in Water Research
- Vol. 309
State estimation under operational uncertainty in water distribution systems
- 25 February 2023
- Published by Elsevier in Renewable Energy
- Vol. 206, 769-783
Dynamic modeling and favorable speed command of variable-speed pumped-storage unit during power regulation
- 25 February 2023
- Published by Elsevier in Renewable Energy
- Vol. 206, 769-783
Dynamic modeling and favorable speed command of variable-speed pumped-storage unit during power regulation
- Open Access
- 14 January 2023
- Published by Wiley in Energy Science & Engineering
- Vol. 11 (3) , 1251-1269
Turbine modeling for steady‐state analysis in hydropower plant networks with complex layouts using a modified global gradient algorithm
Turbines are generally oversimplified in conventional algorithms for steady‐state analysis of hydropower plant (HPP) networks. Moreover, conventional algorithms are hardly suitable for serial HPPs. In this paper, a modified global gradient algorithm (MGGA) is developed by extending turbine models and optimizing turbine interpolation. First, the nonlinear model of turbines is established with the proposed variable resistance factor and added to the global matrix. Then turbine unit quantity interpolation is proposed to compute the turbine operating parameters. Finally, turbine links and pipes can be iterated synchronously, and the global matrix is solved using the Newton–Raphson method. Characteristics of MGGA are evaluated by employing two test HPPs, including rapidity of convergence, computational stability of turbine, and applicability for serial HPPs. The results show that: (a) The iterative numbers of the MGGA are 0.72 and 4.98 times on average less than that of CA1 and CA2 for the accuracy of 10−6 in 400 operating conditions, even though MGGA has an obvious hysteretic nature; (b) Only MGGA can successfully calculate the extreme cases that large head losses in HPP networks; (c) Although fixed head nodes are not present between turbine links, such as serial HPPs, MGGA still works.
- 14 January 2023
- Published by Wiley in Energy Science & Engineering
- Vol. 11 (3) , 1251-1269
Open AccessTurbine modeling for steady‐state analysis in hydropower plant networks with complex layouts using a modified global gradient algorithm
Turbines are generally oversimplified in conventional algorithms for steady‐state analysis of hydropower plant (HPP) networks. Moreover, conventional algorithms are hardly suitable for serial HPPs. In this paper, a modified global gradient algorithm (MGGA) is developed by extending turbine models and optimizing turbine interpolation. First, the nonlinear model of turbines is established with the proposed variable resistance factor and added to the global matrix. Then turbine unit quantity interpolation is proposed to compute the turbine operating parameters. Finally, turbine links and pipes can be iterated synchronously, and the global matrix is solved using the Newton–Raphson method. Characteristics of MGGA are evaluated by employing two test HPPs, including rapidity of convergence, computational stability of turbine, and applicability for serial HPPs. The results show that: (a) The iterative numbers of the MGGA are 0.72 and 4.98 times on average less than that of CA1 and CA2 for the accuracy of 10−6 in 400 operating conditions, even though MGGA has an obvious hysteretic nature; (b) Only MGGA can successfully calculate the extreme cases that large head losses in HPP networks; (c) Although fixed head nodes are not present between turbine links, such as serial HPPs, MGGA still works.
- 13 January 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 60
Active power fluctuations and control in hydraulic disturbance of variable speed pumped storage plants
- 13 January 2023
- Published by Elsevier in Journal of Energy Storage
- Vol. 60
Active power fluctuations and control in hydraulic disturbance of variable speed pumped storage plants
- 5 July 2022
- Published by Elsevier in Renewable Energy
- Vol. 196, 390-404
Improved transfer function method for flexible simulation of hydraulic-mechanical-electrical transient processes of hydro-power plants
- 5 July 2022
- Published by Elsevier in Renewable Energy
- Vol. 196, 390-404
Improved transfer function method for flexible simulation of hydraulic-mechanical-electrical transient processes of hydro-power plants
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability Analysis and Subsynchronous Oscillation of Grid-Tied VSC Under Different Grid Strengths
Recently, with the development of renewable energy, the proportion of power electronic equipment in the power system has gradually increased, which makes the stability and subsynchronous oscillation (SSO) of power system more complicated. In this paper, based on the sixth-order state space model of the grid-tied voltage source converter (VSC) in the time domain, we discuss the stability domain of the system when the parameters of different controllers change under different power grid intensities. These stable regions can provide guidance for the adjustment of controller parameters. Then we further research the dynamic process of the eigenvalues when the system leaves the stable region, and verify that the situation where a single eigenvalue crosses the virtual axis only occurs when the controller parameter is negative. Finally, in the area where the system is unstable, we find that the main factor causing SSO is phase-locked loop (PLL) by comparing the bandwidth of the controller. The results are also consistent with the time domain simulation in Matlab / Simulink.
- 28 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Stability Analysis and Subsynchronous Oscillation of Grid-Tied VSC Under Different Grid Strengths
Recently, with the development of renewable energy, the proportion of power electronic equipment in the power system has gradually increased, which makes the stability and subsynchronous oscillation (SSO) of power system more complicated. In this paper, based on the sixth-order state space model of the grid-tied voltage source converter (VSC) in the time domain, we discuss the stability domain of the system when the parameters of different controllers change under different power grid intensities. These stable regions can provide guidance for the adjustment of controller parameters. Then we further research the dynamic process of the eigenvalues when the system leaves the stable region, and verify that the situation where a single eigenvalue crosses the virtual axis only occurs when the controller parameter is negative. Finally, in the area where the system is unstable, we find that the main factor causing SSO is phase-locked loop (PLL) by comparing the bandwidth of the controller. The results are also consistent with the time domain simulation in Matlab / Simulink.
- 1 May 2021
- Published by Elsevier in Renewable Energy
- Vol. 168, 606-631
Improvement of regulation quality for hydro-dominated power system: quantifying oscillation characteristic and multi-objective optimization
- 1 May 2021
- Published by Elsevier in Renewable Energy
- Vol. 168, 606-631
Improvement of regulation quality for hydro-dominated power system: quantifying oscillation characteristic and multi-objective optimization
- Open Access
- 19 December 2020
- Published by Wiley in Energy Science & Engineering
- Vol. 9 (5) , 694-709
Stability region of hydropower plant with surge tank at HVDC sending terminal
This paper aims to study the stability region of hydropower plants (HPPs) at high‐voltage direct current (HVDC) sending terminal, to theoretically predict the frequency stability of isolated HPPs under small disturbances. The overall transfer function of the system is derived, and the Hurwitz stability criterion is applied to deduce the stability region. The theoretical analysis of the stability region and time‐domain simulation results of the system show good consistency, and this proves the accuracy of the model. The focus of this paper is mainly on the influence of the hydraulic‐mechanical aspects. Improperly tuned governor parameters and unfavourable design of the surge tank could lead to the frequency instability of HPPs, which appears as divergent oscillations of the frequency of units. A key suggestion of this paper is that the control strategy should consider the factors from not only the electrical side but also hydraulic‐mechanical aspects, for enhancing the stability of the HVDC sending terminal. Besides, the influence mechanism and parameter tuning of frequency limitation controller (FLC) are investigated and the results demonstrate its capability of quick compensation for power disturbances at the HVDC receiving terminal.
- 19 December 2020
- Published by Wiley in Energy Science & Engineering
- Vol. 9 (5) , 694-709
Open AccessStability region of hydropower plant with surge tank at HVDC sending terminal
This paper aims to study the stability region of hydropower plants (HPPs) at high‐voltage direct current (HVDC) sending terminal, to theoretically predict the frequency stability of isolated HPPs under small disturbances. The overall transfer function of the system is derived, and the Hurwitz stability criterion is applied to deduce the stability region. The theoretical analysis of the stability region and time‐domain simulation results of the system show good consistency, and this proves the accuracy of the model. The focus of this paper is mainly on the influence of the hydraulic‐mechanical aspects. Improperly tuned governor parameters and unfavourable design of the surge tank could lead to the frequency instability of HPPs, which appears as divergent oscillations of the frequency of units. A key suggestion of this paper is that the control strategy should consider the factors from not only the electrical side but also hydraulic‐mechanical aspects, for enhancing the stability of the HVDC sending terminal. Besides, the influence mechanism and parameter tuning of frequency limitation controller (FLC) are investigated and the results demonstrate its capability of quick compensation for power disturbances at the HVDC receiving terminal.