Arne Meindl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arne Meindl has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Rodrigo Antunes
Max Planck Institute for Plasma Physics
7 shared publications - Ante Hecimovic
ITED, Max-Planck-Institut für Plasmaphysik, Garching, 85748, GERMANY
6 shared publications - Ursel Fantz
Max-Planck-Institut für Plasmaphysik
6 shared publications S. Loehle
High Enthalpy Flow Diagnostics Group, Institute of Space Systems, University of Stuttgart 1 , Pfaffenwaldring 29, 70569 Stuttgart, Germany
4 shared publications- C. Kranig
Max Planck Institute for Plasma Physics
3 shared publications S. Fasoulas
Institute of Space Systems, University of Stuttgart 2 , Pfaffenwaldring 29, 70569 Stuttgart, Germany
3 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (22) , 225201
High-resolution optical emission spectroscopy for CO 2 /CH 4 microwave plasmas: a study of temperatures and electron densities
Dry reforming of methane ( CH 4 + CO 2 → 2 CO + 2 H 2 ) in a microwave plasma torch reactor with two different flow configurations is investigated experimentally via optical emission spectroscopy using a high-resolution Echelle spectrometer in a large pressure range, from 200 mbar to atmospheric pressure and a wide range of CH 4 inflow concentrations, between 0 and 55 % . The rotational and vibrational temperatures determined from C 2 Swan emission are found to be in equilibrium. Temperature measurements for varying CH 4 inflow concentrations reveal two distinct regimes with a narrow transition region: below 40 vol . % CH 4 , temperatures around 6000 K , similar to those in pure CO 2 plasma, are detected. For higher CH 4 inflow concentrations, a steep drop in temperature down to around 4500 K and a subsequent temperature stabilization above 50 vol . % CH 4 is observed. This effect is correlated with the energy demand for the dissociation of increasing amounts of H 2 , potentially preventing undesired dissociation of CO in the process. A flexible methodology for electron density ( n e ) determination from Stark broadening of hydrogen Balmer emission, which includes calculations of Doppler, van der Waals, and resonance broadening for different pressures, temperatures, and CH 4 / CO 2 inflow concentrations is developed and tested. Wherever both could be detected, n e results using H α and H β emission are compared and show very good agreement, building confidence in the methodology. The electron densities are found to be in the range 0.2 − 6 × 10 20 m − 3 , varying most strongly with CH 4 inflow concentration and pressure. Results obtained for a standard forward vortex flow configuration and a reverse vortex configuration featuring a constricted resonator outlet indicate that the latter promotes larger electron densities compared to the former in the pressure range above 600 mbar .
- 3 June 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (22) , 225201
Open AccessHigh-resolution optical emission spectroscopy for CO 2 /CH 4 microwave plasmas: a study of temperatures and electron densities
Dry reforming of methane ( CH 4 + CO 2 → 2 CO + 2 H 2 ) in a microwave plasma torch reactor with two different flow configurations is investigated experimentally via optical emission spectroscopy using a high-resolution Echelle spectrometer in a large pressure range, from 200 mbar to atmospheric pressure and a wide range of CH 4 inflow concentrations, between 0 and 55 % . The rotational and vibrational temperatures determined from C 2 Swan emission are found to be in equilibrium. Temperature measurements for varying CH 4 inflow concentrations reveal two distinct regimes with a narrow transition region: below 40 vol . % CH 4 , temperatures around 6000 K , similar to those in pure CO 2 plasma, are detected. For higher CH 4 inflow concentrations, a steep drop in temperature down to around 4500 K and a subsequent temperature stabilization above 50 vol . % CH 4 is observed. This effect is correlated with the energy demand for the dissociation of increasing amounts of H 2 , potentially preventing undesired dissociation of CO in the process. A flexible methodology for electron density ( n e ) determination from Stark broadening of hydrogen Balmer emission, which includes calculations of Doppler, van der Waals, and resonance broadening for different pressures, temperatures, and CH 4 / CO 2 inflow concentrations is developed and tested. Wherever both could be detected, n e results using H α and H β emission are compared and show very good agreement, building confidence in the methodology. The electron densities are found to be in the range 0.2 − 6 × 10 20 m − 3 , varying most strongly with CH 4 inflow concentration and pressure. Results obtained for a standard forward vortex flow configuration and a reverse vortex configuration featuring a constricted resonator outlet indicate that the latter promotes larger electron densities compared to the former in the pressure range above 600 mbar .
- Open Access
- 24 March 2026
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 106
Reverse water gas shift in microwave plasma for O2 removal and CO2 conversion enhancement
- 24 March 2026
- Published by Elsevier in Journal of CO2 Utilization
- Vol. 106
Open AccessReverse water gas shift in microwave plasma for O2 removal and CO2 conversion enhancement
- Open Access
- 30 August 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 170
Hydrogen production from ammonia using a microwave plasma torch at atmospheric pressure
- 30 August 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 170
Open AccessHydrogen production from ammonia using a microwave plasma torch at atmospheric pressure
- 16 July 2025
- Published by Springer Nature
- p. 135-165
Plasmas for the Production of Value-Added Chemicals
- 16 July 2025
- Published by Springer Nature
- p. 135-165
Plasmas for the Production of Value-Added Chemicals
- Open Access
- 1 April 2024
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 33 (4) , 045013
Spatially resolved TALIF investigation of atomic oxygen in the effluent of a CO2 microwave discharge
A diagnostic setup for one-dimensionally spatially resolved two-photon absorption laser-induced fluorescence (TALIF) detection of ground state oxygen atoms ( 2 p 4 3 P 2 , 1 , 0 ) is developed. The goal of this study is to investigate the evolution of temperatures and absolute number densities of oxygen atoms along the effluent of a low-pressure CO2 microwave discharge in order to gain insights into some of the mechanisms governing the post-discharge regime. The plasma source is operated at conditions of 600 W– 1200 W of absorbed power with flow rates of 74 sccm and 370 sccm pure CO2 at pressures between 1.2 mbar and 5 mbar with specific energy inputs up to 111.9 eV/molecule. These operating conditions exhibit high CO2 conversions (up to 90%) at low energy efficiencies (2%–7.4%), due to direct electron impact dissociation driving the conversion process resulting in splitting of CO2 into CO and metastable oxygen atoms. The TALIF measurements yield spatially resolved translational temperatures between 1000 K– 1600 K for most operating conditions and axial positions along the effluent. Reference measurements with xenon 6 p ′ [ 3 / 2 ] 2 are used for absolute number density calibration. The resulting axially resolved number density profiles of ground state atomic oxygen increase along the effluent, even at considerable distances of several centimeters from the active discharge, before they reach a maximum between 5 × 10 20 m−3 and 2.2 × 10 21 m−3 depending on the condition, and decrease after that. This behavior indicates the potential significance of quenching of metastable oxygen atoms within the post-discharge regime of the investigated CO2 discharges. The measured spatially resolved number density evolutions are qualitatively consistent with quenching via wall collisions being the dominant deactivation mechanism, underlining the importance of particle-wall interactions.
- 1 April 2024
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 33 (4) , 045013
Open AccessSpatially resolved TALIF investigation of atomic oxygen in the effluent of a CO2 microwave discharge
A diagnostic setup for one-dimensionally spatially resolved two-photon absorption laser-induced fluorescence (TALIF) detection of ground state oxygen atoms ( 2 p 4 3 P 2 , 1 , 0 ) is developed. The goal of this study is to investigate the evolution of temperatures and absolute number densities of oxygen atoms along the effluent of a low-pressure CO2 microwave discharge in order to gain insights into some of the mechanisms governing the post-discharge regime. The plasma source is operated at conditions of 600 W– 1200 W of absorbed power with flow rates of 74 sccm and 370 sccm pure CO2 at pressures between 1.2 mbar and 5 mbar with specific energy inputs up to 111.9 eV/molecule. These operating conditions exhibit high CO2 conversions (up to 90%) at low energy efficiencies (2%–7.4%), due to direct electron impact dissociation driving the conversion process resulting in splitting of CO2 into CO and metastable oxygen atoms. The TALIF measurements yield spatially resolved translational temperatures between 1000 K– 1600 K for most operating conditions and axial positions along the effluent. Reference measurements with xenon 6 p ′ [ 3 / 2 ] 2 are used for absolute number density calibration. The resulting axially resolved number density profiles of ground state atomic oxygen increase along the effluent, even at considerable distances of several centimeters from the active discharge, before they reach a maximum between 5 × 10 20 m−3 and 2.2 × 10 21 m−3 depending on the condition, and decrease after that. This behavior indicates the potential significance of quenching of metastable oxygen atoms within the post-discharge regime of the investigated CO2 discharges. The measured spatially resolved number density evolutions are qualitatively consistent with quenching via wall collisions being the dominant deactivation mechanism, underlining the importance of particle-wall interactions.
- Open Access
- 27 December 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 481
CO 2 dissociation using a lab-scale microwave plasma torch: An experimental study in view of industrial application
- 27 December 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 481
Open AccessCO 2 dissociation using a lab-scale microwave plasma torch: An experimental study in view of industrial application
- Open Access
- 21 October 2023
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 11 (44) , 15984-15993
Proof of Concept for O2 Removal with Multiple LCCF Membranes Accommodated in the Effluent of a CO2 Plasma Torch
- 21 October 2023
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 11 (44) , 15984-15993
Open AccessProof of Concept for O2 Removal with Multiple LCCF Membranes Accommodated in the Effluent of a CO2 Plasma Torch
- Open Access
- 6 July 2022
- Published by Copernicus GmbH
Spectral Observations at the CILBO Observatory: Calibration andData Sets
This talk will introduce the The Canary Island Long-Baseline Observatory (CILBO), a double station meteor camera setup located on the Canary Islands and operated by ESA’s Meteor Research Group since 2010. Our observations of meteors are obtained in the visual wavelength band by intensified video cameras from both stations, supplemented by an intensified video camera mounted with a spectral grating at one of the locations. The cameras observe during cloudless and precipitation-free nights and data are transferred to a main computer located at ESA/ESTEC once a day. The image frames that contain spectral information are calibrated, corrected, and finally processed into line intensity profiles. An ablation simulation, based on Bayesian statistics using a Markov-Chain Monte-Carlo method, allows to determine a parameter space, including the ablation temperatures, chemical elements and their corresponding line intensities, to fit against the line intensity profiles of the observed meteor spectra. The algorithm is presented in this talk. Several hundred spectra have been processed and will be made available through the Guest Archive Facility of the Planetary Science Archive of ESA.
- 6 July 2022
- Published by Copernicus GmbH
Open AccessSpectral Observations at the CILBO Observatory: Calibration andData Sets
This talk will introduce the The Canary Island Long-Baseline Observatory (CILBO), a double station meteor camera setup located on the Canary Islands and operated by ESA’s Meteor Research Group since 2010. Our observations of meteors are obtained in the visual wavelength band by intensified video cameras from both stations, supplemented by an intensified video camera mounted with a spectral grating at one of the locations. The cameras observe during cloudless and precipitation-free nights and data are transferred to a main computer located at ESA/ESTEC once a day. The image frames that contain spectral information are calibrated, corrected, and finally processed into line intensity profiles. An ablation simulation, based on Bayesian statistics using a Markov-Chain Monte-Carlo method, allows to determine a parameter space, including the ablation temperatures, chemical elements and their corresponding line intensities, to fit against the line intensity profiles of the observed meteor spectra. The algorithm is presented in this talk. Several hundred spectra have been processed and will be made available through the Guest Archive Facility of the Planetary Science Archive of ESA.
- Open Access
- 1 November 2021
- Published by Springer Nature in CEAS Space Journal
- Vol. 14 (2) , 395-406
Assessment of high enthalpy flow conditions for re-entry aerothermodynamics in the plasma wind tunnel facilities at IRS
This article presents the full operational experimental capabilities of the plasma wind tunnel facilities at the Institute of Space Systems at the University of Stuttgart. The simulation of the aerothermodynamic environment experienced by vehicles entering the atmosphere of Earth is attempted using three different facilities. Utilizing the three different facilities, the recent improvements enable a unique range of flow conditions in relation to other known facilities. Recent performance optimisations are highlighted in this article. Based on the experimental conditions demonstrated a corresponding flight scenario is derived using a ground-to-flight extrapolation approach based on local mass-specific enthalpy, total pressure and boundary layer edge velocity gradient. This shows that the three facilities cover the challenging parts of the aerothermodynamics along the entry trajectory from Low Earth Orbit. Furthermore, the more challenging conditions arising during interplanetary return at altitudes above 70 km are as well covered.
- 1 November 2021
- Published by Springer Nature in CEAS Space Journal
- Vol. 14 (2) , 395-406
Open AccessAssessment of high enthalpy flow conditions for re-entry aerothermodynamics in the plasma wind tunnel facilities at IRS
This article presents the full operational experimental capabilities of the plasma wind tunnel facilities at the Institute of Space Systems at the University of Stuttgart. The simulation of the aerothermodynamic environment experienced by vehicles entering the atmosphere of Earth is attempted using three different facilities. Utilizing the three different facilities, the recent improvements enable a unique range of flow conditions in relation to other known facilities. Recent performance optimisations are highlighted in this article. Based on the experimental conditions demonstrated a corresponding flight scenario is derived using a ground-to-flight extrapolation approach based on local mass-specific enthalpy, total pressure and boundary layer edge velocity gradient. This shows that the three facilities cover the challenging parts of the aerothermodynamics along the entry trajectory from Low Earth Orbit. Furthermore, the more challenging conditions arising during interplanetary return at altitudes above 70 km are as well covered.