HKHerbert G. Kroon

Herbert G. Kroon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Herbert G. Kroon has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Current Evidence of Neuroprotection in TAVR

    by Herbert G. Kroon, Nicolas M. Van Mieghem

  • Open Access

    Vascular complications with a plug‐based vascular closure device after transcatheter aortic valve replacement: Predictors and bail‐outs

    by Maarten P. van Wiechen, Herbert Kroon, Thijmen W. Hokken, Joris F. Ooms, Marjo J. de Ronde‐Tillmans, Joost Daemen, Peter P. de Jaegere, Nicolas M. Van Mieghem

    Background: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking.Aim: To evaluate MANTA in a real‐world population and identify predictors for vascular complications.Methods: All patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) between January 2016 and May 2020 with MANTA closure were included. Baseline characteristics were collected, pre‐procedural computed tomography and post‐deployment femoral angiograms were analyzed for anatomical differences. The primary endpoint was a composite of access site related major and minor vascular complications at 30 days follow‐up according to the VARC‐2 definitions. Secondary endpoints included bleeding, time to hemostasis, procedural length and incomplete arteriotomy closure or arterial occlusion by angiography. A Cox proportional hazards model was used to compare all‐cause mortality for patients with and without an access site complication.Results: The 512 patients underwent TAVR with MANTA access closure. Median age was 80 (IQR 75–85), 53% was male, median BMI was 26.4 kg/m2 (IQR 23.4–29.7). Access site related major‐ or minor vascular complication occurred in 20 (4%) and 23 (4%) of patients respectively. Median time to hemostasis was 42 s (IQR 28–98). Post deployment angiogram showed an occlusion in 24 patients (5%), incomplete closure in 60 patients (12%) or both in three patients (1%). Of these 87 patients, 36 (41%) had a vascular complication. Femoral artery diameter (OR 0.70 [0.53–0.93]), low‐ (OR 3.47 [1.21–10.00]) and high (OR 2.43 [1.16–5.10]) arteriotomies were independent predictors for vascular complications.Conclusion: In this contemporary TAVR population, access‐site related complications occurred in 8% of patients and were mainly due to percutaneous closure device failure. Small artery diameter and off‐target punctures were independent predictors.


  • Open Access

    Dedicated plug based closure for large bore access –The MARVEL prospective registry

    by Herbert G. Kroon, Pim A.L. Tonino, Mikko Savontaus, Giovanni Amoroso, Mika Laine, Evald H. Christiansen, Stefan Toggweiler, Jur Ten Berg, Janarthanan Sathananthan, Joost Daemen, et al.

    Objectives: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers.Background: The MANTA is a novel plug‐based device for large bore arteriotomy closure.Methods: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC‐2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications.Results: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS‐score of 2.7 [IQR 2.0–4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20–120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications.Conclusion: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real‐world conditions.