Malik I. Al-Amayreh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Malik I. Al-Amayreh has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Ali Alahmer
Department of Mechanical Engineering, Tuskegee University, Tuskegee, USA
6 shared publications Ahmad Alamayreh
American University of Madaba
4 shared publications- Ahmad Alamayreh
Department of Intelligent Robotics Systems Engineering, American University of Madaba, Madaba, Jordan
2 shared publications Amal A. Amer
2 shared publicationsChristian Weindl
Lehrstuhl für Elektrische Energieversorgung, Universität Erlangen, Erlangen, Germany
2 shared publicationsHarald Hofmann
Lehrstuhl für Elektrische Energieversorgung, Universität Erlangen, Erlangen, Germany
2 shared publications
Latest Publications
- 20 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (29) , 295102
Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier
Hot-wire anemometry is fundamentally constrained by an inverse physical relationship between static sensitivity and dynamic bandwidth, creating an inherent trade-off between measurement precision and response speed. Conventional single-mode architectures cannot achieve optimal performance across the full velocity envelope: constant power (CP) operation offers superior sensitivity but becomes dynamically unstable at low flow velocities due to excessive thermal inertia, while the constant temperature difference (CTD) mode guarantees stability under weak convective cooling yet suffers from severely degraded resolution at high velocities, where elevated electronic noise floors dominate. To address these limitations, this work introduces a physics-informed digital twin control framework that enables adaptive mode switching designed for real-time minimization of the velocity resolution limit ( δ U min ) for hot-wire sensors. The proposed control architecture employs a unified utility function that simultaneously maximizes the signal-to-noise ratio (SNR) while enforcing a bandwidth-penalized dynamic fidelity constraint. For a defined target bandwidth of 1000 Hz, the controller defaults to CTD mode at low velocities ( U < 4.3 m s −1 ) to ensure stability when convective heat transfer cannot sufficiently counteract thermal inertia. As velocity increases, the system autonomously transitions to CP mode once the intrinsic thermal time constant satisfies the required bandwidth, safely unlocking up to three orders of magnitude of precision improvement relative to a conventional, stability-locked CTD baseline. The steady-state physics engine is validated against experimental power consumption benchmarks ( R 2 = 0.95 , MAPE = 2.01 % ), accurately resolving complex substrate heat leakage without empirical curve-fitting. The resulting hybrid architecture achieves a resolution gain factor of > 2700 relative to conventional methods, offering a scalable, geometry-invariant solution for next-generation aerodynamic and fluid-mechanics measurement systems.
- 20 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (29) , 295102
Physics-informed digital twin for adaptive smart anemometry: overcoming the bandwidth–sensitivity barrier
Hot-wire anemometry is fundamentally constrained by an inverse physical relationship between static sensitivity and dynamic bandwidth, creating an inherent trade-off between measurement precision and response speed. Conventional single-mode architectures cannot achieve optimal performance across the full velocity envelope: constant power (CP) operation offers superior sensitivity but becomes dynamically unstable at low flow velocities due to excessive thermal inertia, while the constant temperature difference (CTD) mode guarantees stability under weak convective cooling yet suffers from severely degraded resolution at high velocities, where elevated electronic noise floors dominate. To address these limitations, this work introduces a physics-informed digital twin control framework that enables adaptive mode switching designed for real-time minimization of the velocity resolution limit ( δ U min ) for hot-wire sensors. The proposed control architecture employs a unified utility function that simultaneously maximizes the signal-to-noise ratio (SNR) while enforcing a bandwidth-penalized dynamic fidelity constraint. For a defined target bandwidth of 1000 Hz, the controller defaults to CTD mode at low velocities ( U < 4.3 m s −1 ) to ensure stability when convective heat transfer cannot sufficiently counteract thermal inertia. As velocity increases, the system autonomously transitions to CP mode once the intrinsic thermal time constant satisfies the required bandwidth, safely unlocking up to three orders of magnitude of precision improvement relative to a conventional, stability-locked CTD baseline. The steady-state physics engine is validated against experimental power consumption benchmarks ( R 2 = 0.95 , MAPE = 2.01 % ), accurately resolving complex substrate heat leakage without empirical curve-fitting. The resulting hybrid architecture achieves a resolution gain factor of > 2700 relative to conventional methods, offering a scalable, geometry-invariant solution for next-generation aerodynamic and fluid-mechanics measurement systems.
- 20 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (29) , 295103
A computational framework for real-time compensation of substrate thermal inertia in hot-film sensors via a physics-informed digital twin
Flush-mounted hot-film sensors offer exceptional mechanical robustness, but their dynamic fidelity is fundamentally constrained by conductive heat leakage into the underlying substrate. This thermal inertia acts as a dominant low-pass filter, corrupting unsteady flow diagnostics with severe phase lag and artificial hysteresis. To overcome this inherent trade-off without physically compromising structural durability, this work introduces a Cyber-Physical Co-Design framework centered on a physics-informed digital twin (PIDT). The framework embeds a two-state coupled energy model within a deterministic, time-domain inverse dynamics compensator, enabling the real-time analytical compensation of parasitic substrate heat flux. Validated computationally using steady-state data from a 1 mm 3D-printed substrate, the PIDT drastically reduces sensor settling time from 34.86 s to 1.75 s. Furthermore, the framework demonstrates a theoretical capacity to extend the effective measurement bandwidth by approximately 8-fold (from 1.0 Hz to 7.9 Hz), effectively collapsing artificial dynamic hysteresis loops to recover ground-truth flow trajectories. Ultimately, this computational architecture establishes the mathematical foundation for rugged sensors to achieve dynamic spectral fidelity approaching that of delicate micro-fabricated devices.
- 20 July 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (29) , 295103
A computational framework for real-time compensation of substrate thermal inertia in hot-film sensors via a physics-informed digital twin
Flush-mounted hot-film sensors offer exceptional mechanical robustness, but their dynamic fidelity is fundamentally constrained by conductive heat leakage into the underlying substrate. This thermal inertia acts as a dominant low-pass filter, corrupting unsteady flow diagnostics with severe phase lag and artificial hysteresis. To overcome this inherent trade-off without physically compromising structural durability, this work introduces a Cyber-Physical Co-Design framework centered on a physics-informed digital twin (PIDT). The framework embeds a two-state coupled energy model within a deterministic, time-domain inverse dynamics compensator, enabling the real-time analytical compensation of parasitic substrate heat flux. Validated computationally using steady-state data from a 1 mm 3D-printed substrate, the PIDT drastically reduces sensor settling time from 34.86 s to 1.75 s. Furthermore, the framework demonstrates a theoretical capacity to extend the effective measurement bandwidth by approximately 8-fold (from 1.0 Hz to 7.9 Hz), effectively collapsing artificial dynamic hysteresis loops to recover ground-truth flow trajectories. Ultimately, this computational architecture establishes the mathematical foundation for rugged sensors to achieve dynamic spectral fidelity approaching that of delicate micro-fabricated devices.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 15117-15124
Autonomous Design of Microcalorimetric Flow Sensors: A Bayesian-Optimized Machine Learning Framework
The geometric configuration of micro-calorimetric flow sensors strongly influences their sensitivity and linear dynamic range. Traditional design workflows often rely on static heuristics or exhaustive Finite Element Method (FEM) simulations. These approaches are computationally expensive and frequently lead to suboptimal sensor placement. To overcome this limitation, we propose an autonomous Physics-Informed Machine Learning (PIML) framework for geometric optimization. The framework integrates a reduced-order digital twin—solving the one-dimensional convection-diffusion equation—with a Bayesian Optimization (BO) engine based on Gaussian Process regression. Using an Expected Improvement acquisition function, the system efficiently identifies the globally optimal heater-sensor separation distance with minimal evaluations. Results show that the optimal sensor location is dynamic, shifting downstream as flow velocity increases to follow the elongating thermal wake. Moreover, optimizing for the absolute signal magnitude provides a superior signal-to-noise ratio compared to traditional derivative-based sensitivity metrics, especially in saturation regimes. The framework was validated against 3D numerical simulations and experimental data with less than 5% error. It also identified a critical design point at a microchannel height of 200 μm, enabling rapid, fluid-specific sensor synthesis.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (10) , 15117-15124
Autonomous Design of Microcalorimetric Flow Sensors: A Bayesian-Optimized Machine Learning Framework
The geometric configuration of micro-calorimetric flow sensors strongly influences their sensitivity and linear dynamic range. Traditional design workflows often rely on static heuristics or exhaustive Finite Element Method (FEM) simulations. These approaches are computationally expensive and frequently lead to suboptimal sensor placement. To overcome this limitation, we propose an autonomous Physics-Informed Machine Learning (PIML) framework for geometric optimization. The framework integrates a reduced-order digital twin—solving the one-dimensional convection-diffusion equation—with a Bayesian Optimization (BO) engine based on Gaussian Process regression. Using an Expected Improvement acquisition function, the system efficiently identifies the globally optimal heater-sensor separation distance with minimal evaluations. Results show that the optimal sensor location is dynamic, shifting downstream as flow velocity increases to follow the elongating thermal wake. Moreover, optimizing for the absolute signal magnitude provides a superior signal-to-noise ratio compared to traditional derivative-based sensitivity metrics, especially in saturation regimes. The framework was validated against 3D numerical simulations and experimental data with less than 5% error. It also identified a critical design point at a microchannel height of 200 μm, enabling rapid, fluid-specific sensor synthesis.
- Open Access
- 10 December 2025
- Published by Elsevier in Materials Today Communications
- Vol. 50
Bayesian-optimized machine learning framework for predicting Thermal Contact Resistance
- 10 December 2025
- Published by Elsevier in Materials Today Communications
- Vol. 50
Open AccessBayesian-optimized machine learning framework for predicting Thermal Contact Resistance
- Open Access
- 23 September 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 75
Harnessing fuel cell and PVT for cogeneration in buildings: A comparative analysis in different climates
- 23 September 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 75
Open AccessHarnessing fuel cell and PVT for cogeneration in buildings: A comparative analysis in different climates
- Open Access
- 15 May 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 6 (1) , 1-16
Impact of EV charging strategies on solar-powered residential buildings: unidirectional vs. bidirectional charging in Jordan
Unidirectional chargers, valued for their simplicity and cost-effectiveness, are widely deployed. In contrast, bidirectional chargers enable advanced functionalities such as Vehicle-to-Grid (V2G) and Vehicle-to-Home (V2H) but come with greater complexity, higher costs, and design challenges. This aim of this research is to analyze unidirectional and bidirectional charging systems integrated with renewable energy, from both economic and environmental perspectives. Additionally, the research conducts a technical analysis of different EV charging technologies via Polysun software, considering a predefined mobility profile that includes charging times and kilometers driven. The study focuses on households with renewable energy systems connected to the grid, evaluating energy consumption, grid reliance, CO₂ emissions, and financial viability across scenarios with varying numbers of EVs (1–3) over one year. While bidirectional EV setups enhance self-consumption and reduce dependence on the external grid, they face financial challenges, including higher initial costs and a lower net present value (NPV) due to maintenance expenses. In Jordan the time-of-use (TOU) pricing system has applied for EVs charging. This study reveals that the bidirectional EV charging improves energy efficiency and reduces CO2 emissions by optimizing PV energy utilization in Jordan to charge EVs, however, its increased initial costs under TOU pricing highlight the need for supportive policies to encourage wider adoption.
- 15 May 2025
- Published by Springer Nature in Discover Sustainability
- Vol. 6 (1) , 1-16
Open AccessImpact of EV charging strategies on solar-powered residential buildings: unidirectional vs. bidirectional charging in Jordan
Unidirectional chargers, valued for their simplicity and cost-effectiveness, are widely deployed. In contrast, bidirectional chargers enable advanced functionalities such as Vehicle-to-Grid (V2G) and Vehicle-to-Home (V2H) but come with greater complexity, higher costs, and design challenges. This aim of this research is to analyze unidirectional and bidirectional charging systems integrated with renewable energy, from both economic and environmental perspectives. Additionally, the research conducts a technical analysis of different EV charging technologies via Polysun software, considering a predefined mobility profile that includes charging times and kilometers driven. The study focuses on households with renewable energy systems connected to the grid, evaluating energy consumption, grid reliance, CO₂ emissions, and financial viability across scenarios with varying numbers of EVs (1–3) over one year. While bidirectional EV setups enhance self-consumption and reduce dependence on the external grid, they face financial challenges, including higher initial costs and a lower net present value (NPV) due to maintenance expenses. In Jordan the time-of-use (TOU) pricing system has applied for EVs charging. This study reveals that the bidirectional EV charging improves energy efficiency and reduces CO2 emissions by optimizing PV energy utilization in Jordan to charge EVs, however, its increased initial costs under TOU pricing highlight the need for supportive policies to encourage wider adoption.
- Open Access
- 5 November 2024
- Published by Springer Nature in Discover Sustainability
- Vol. 5 (1) , 1-21
Evaluating the economic and environmental viability of hybrid solar-geothermal heat pump systems in Jordan using multi-criteria decision analysis
- 5 November 2024
- Published by Springer Nature in Discover Sustainability
- Vol. 5 (1) , 1-21
Open AccessEvaluating the economic and environmental viability of hybrid solar-geothermal heat pump systems in Jordan using multi-criteria decision analysis
- Open Access
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135159-135171
Artificial Coherent Circulation of Electromagnetic Flows in Free-Space
This paper explores the generation of coherent electromagnetic energy flows to form a shock wave in free-space as a linear medium. Flows of energies from several waves need to build up coherently to create the wave. In free-space, energy in the propagation direction flows at speed of light and therefore cannot match the required energy accumulation. Electromagnetic waves carrying orbital angular momentum are suggested instead of ordinary plane waves because they have a controllable energy flow in the transverse direction of propagation. Flows of several waves are managed under certain conditions to accumulate energy and create a shock wave in the transverse direction. These conditions must be maintained to preserve the waveform during propagation. Previous studies on acoustical shock waves in a nonlinear medium explained the effect of nonlinear medium on the wave. Nonlinear effects are implemented to create similar propagation conditions in the linear medium and to preserve the waveform. The wave, however, rotates and expands during propagation due to the evolution of its internal energies. Internal energy flows are studied, and an analogy is drawn with flows in fluids. Numerical simulations are conducted to support the theoretical derivations on wave generation and propagation.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135159-135171
Open AccessArtificial Coherent Circulation of Electromagnetic Flows in Free-Space
This paper explores the generation of coherent electromagnetic energy flows to form a shock wave in free-space as a linear medium. Flows of energies from several waves need to build up coherently to create the wave. In free-space, energy in the propagation direction flows at speed of light and therefore cannot match the required energy accumulation. Electromagnetic waves carrying orbital angular momentum are suggested instead of ordinary plane waves because they have a controllable energy flow in the transverse direction of propagation. Flows of several waves are managed under certain conditions to accumulate energy and create a shock wave in the transverse direction. These conditions must be maintained to preserve the waveform during propagation. Previous studies on acoustical shock waves in a nonlinear medium explained the effect of nonlinear medium on the wave. Nonlinear effects are implemented to create similar propagation conditions in the linear medium and to preserve the waveform. The wave, however, rotates and expands during propagation due to the evolution of its internal energies. Internal energy flows are studied, and an analogy is drawn with flows in fluids. Numerical simulations are conducted to support the theoretical derivations on wave generation and propagation.
- Open Access
- 20 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Efficiency enhancement in direct thermal energy storage systems using dual phase change materials and nanoparticle additives
- 20 May 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 59
Open AccessEfficiency enhancement in direct thermal energy storage systems using dual phase change materials and nanoparticle additives
- 1 January 2024
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 36 (1) , 31-43
Cryogenic cooling using liquid nitrogen to produce massive concrete: temperature, setting time and compressive strength
Mixing cement with water in mass concrete production is associated with hydration heat generation, which may cause concrete mixes to dry out and crack. The experimental work aims to evaluate the effects of using liquid nitrogen (LN) in cooling mortar mixes and concrete. LN was used in doses of 0, 25, 50, 75 and 100% by water volume to either cool the mixing water at T = 4°C or to inject it into concrete mixtures directly. The concrete mix proportions were based on ACI PRC-207.1-21 for mass concrete. The mortars' initial and final setting times and temperatures indicated that a greater percentage of LN delayed the hardening process and the peak hardening rates, exhibiting slower cement hydration. LN cooling enhances the compressive strength of mortar and concrete cubes when VLN/Vwater≤1. However, concrete compressive strength decreased due to ice formation that turned into voids when VLN/Vwater>1. Cooling concrete with chilled water (T = 4°C) showed a 30% and 34.51% increase in mortar and concrete cubes' compressive strength, respectively, and a maximum of 16.45% and 12.97% when LN was injected into mortars and concrete mixes. Cooling the concrete with chilled water (T = 4°C) showed a slower cooling process, which improved cement hydration results.
- 1 January 2024
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 36 (1) , 31-43
Cryogenic cooling using liquid nitrogen to produce massive concrete: temperature, setting time and compressive strength
Mixing cement with water in mass concrete production is associated with hydration heat generation, which may cause concrete mixes to dry out and crack. The experimental work aims to evaluate the effects of using liquid nitrogen (LN) in cooling mortar mixes and concrete. LN was used in doses of 0, 25, 50, 75 and 100% by water volume to either cool the mixing water at T = 4°C or to inject it into concrete mixtures directly. The concrete mix proportions were based on ACI PRC-207.1-21 for mass concrete. The mortars' initial and final setting times and temperatures indicated that a greater percentage of LN delayed the hardening process and the peak hardening rates, exhibiting slower cement hydration. LN cooling enhances the compressive strength of mortar and concrete cubes when VLN/Vwater≤1. However, concrete compressive strength decreased due to ice formation that turned into voids when VLN/Vwater>1. Cooling concrete with chilled water (T = 4°C) showed a 30% and 34.51% increase in mortar and concrete cubes' compressive strength, respectively, and a maximum of 16.45% and 12.97% when LN was injected into mortars and concrete mixes. Cooling the concrete with chilled water (T = 4°C) showed a slower cooling process, which improved cement hydration results.