Congcong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Congcong Zhou has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Xuesong Ye
Zhejiang University
17 shared publications Xuesong Ye
Zhejiang University
6 shared publications- Xianglin Ren
College of Biomedical Engineering and Instrument Science, Biosensor National Special Laboratory, Zhejiang University, Hangzhou, China
5 shared publications Jingjie Feng
Biosensor National Special Laboratory, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, 310027, People's Republic of China
4 shared publications- Bo Liang
Zhejiang University
3 shared publications - Hui Liu
Cognitive Systems Lab, University of Bremen, Enrique-Schmidt-Str. 5, 28359 Bremen, Germany
3 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 7, e10
A lightweight passive ankle exoskeleton with dual-phase energy harvesting and stiffness adaptation
Passive exoskeletons offer several advantages, including lightweight design, simple structure, and inherent energy efficiency. Most existing passive exoskeletons rely on clutch mechanisms to control spring-based energy storage and release, typically focusing only on recovering biomechanical energy during the stance phase of gait. In this study, we propose and analyze a lightweight passive ankle exoskeleton capable of harvesting and releasing energy during both the stance and swing phases of walking. The device aims to enhance gait assistance while maintaining structural simplicity and minimizing weight. By integrating the optimal stiffness ratio between the stance and swing phases, derived from musculoskeletal model simulations, with previously established optimal stance-phase stiffness parameters, we determined a suitable stiffness coefficient for the swing-phase spring. To validate the design, we conducted comparative experiments on participants walking with exoskeletons configured with different stiffness coefficients. Spatiotemporal parameters, metabolic energy cost, and muscle activation patterns were analyzed to evaluate performance. The results demonstrate that the proposed exoskeleton effectively reduces Soleus muscle activation while increasing tibialis anterior activity, leading to a 6.84% reduction in walking energy cost compared to a nonassistive condition. Furthermore, energy recovery during the swing phase alone contributes an additional 1.67% reduction in energy expenditure, improving overall walking efficiency. The proposed design also eliminates complex clutch components, significantly simplifying manufacturing and reducing costs, thereby enhancing the applicability of passive exoskeletons in daily mobility and rehabilitation scenarios.
- 4 August 2026
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 7, e10
Open AccessA lightweight passive ankle exoskeleton with dual-phase energy harvesting and stiffness adaptation
Passive exoskeletons offer several advantages, including lightweight design, simple structure, and inherent energy efficiency. Most existing passive exoskeletons rely on clutch mechanisms to control spring-based energy storage and release, typically focusing only on recovering biomechanical energy during the stance phase of gait. In this study, we propose and analyze a lightweight passive ankle exoskeleton capable of harvesting and releasing energy during both the stance and swing phases of walking. The device aims to enhance gait assistance while maintaining structural simplicity and minimizing weight. By integrating the optimal stiffness ratio between the stance and swing phases, derived from musculoskeletal model simulations, with previously established optimal stance-phase stiffness parameters, we determined a suitable stiffness coefficient for the swing-phase spring. To validate the design, we conducted comparative experiments on participants walking with exoskeletons configured with different stiffness coefficients. Spatiotemporal parameters, metabolic energy cost, and muscle activation patterns were analyzed to evaluate performance. The results demonstrate that the proposed exoskeleton effectively reduces Soleus muscle activation while increasing tibialis anterior activity, leading to a 6.84% reduction in walking energy cost compared to a nonassistive condition. Furthermore, energy recovery during the swing phase alone contributes an additional 1.67% reduction in energy expenditure, improving overall walking efficiency. The proposed design also eliminates complex clutch components, significantly simplifying manufacturing and reducing costs, thereby enhancing the applicability of passive exoskeletons in daily mobility and rehabilitation scenarios.
- Open Access
- 30 June 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (7) , 803
Gray Wolf Optimization-Long Short-Term Memory Based Temperature Estimation and Closed-Loop Control Method in Microfluidic Chemiluminescence Immunoassay
Driven by the rising demand for point-of-care testing (POCT) in aging societies, accurate temperature regulation of reaction solutions has become a core technical bottleneck for miniaturized chemiluminescence immunoassay systems, since conventional indirect control strategies inevitably produce systematic deviations. To tackle this challenge, we present an integrated solution that couples multiphysics simulation, data-driven temperature estimation modeling, and embedded hardware design. We constructed a COMSOL heat transfer model to analyze the thermal performance of the microfluidic chip. Meanwhile, a grey wolf optimization (GWO) enhanced long short-term memory (LSTM) network was developed to infer the unmeasured actual reaction solution temperature based on accessible parameters, including heating voltage, ambient temperature and substrate temperature. The obtained temperature estimation was then fed back to a fuzzy PID controller for closed-loop regulation. Experimental results demonstrated that the GWO-LSTM model limited the estimation error within 0.3 °C, and the steady-state temperature control accuracy reached ±0.2 °C or higher under fluctuating ambient conditions and diverse initial states. For cardiac troponin I (cTnI) detection, the proposed system shortened the incubation duration and reduced the coefficient of variation from 10.77% to 2.69%. This work addresses the key bottleneck restricting precise temperature control in microfluidic chemiluminescence analyzers, which provides robust technical support for the development of next-generation high-performance POCT instruments.
- 30 June 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (7) , 803
Open AccessGray Wolf Optimization-Long Short-Term Memory Based Temperature Estimation and Closed-Loop Control Method in Microfluidic Chemiluminescence Immunoassay
Driven by the rising demand for point-of-care testing (POCT) in aging societies, accurate temperature regulation of reaction solutions has become a core technical bottleneck for miniaturized chemiluminescence immunoassay systems, since conventional indirect control strategies inevitably produce systematic deviations. To tackle this challenge, we present an integrated solution that couples multiphysics simulation, data-driven temperature estimation modeling, and embedded hardware design. We constructed a COMSOL heat transfer model to analyze the thermal performance of the microfluidic chip. Meanwhile, a grey wolf optimization (GWO) enhanced long short-term memory (LSTM) network was developed to infer the unmeasured actual reaction solution temperature based on accessible parameters, including heating voltage, ambient temperature and substrate temperature. The obtained temperature estimation was then fed back to a fuzzy PID controller for closed-loop regulation. Experimental results demonstrated that the GWO-LSTM model limited the estimation error within 0.3 °C, and the steady-state temperature control accuracy reached ±0.2 °C or higher under fluctuating ambient conditions and diverse initial states. For cardiac troponin I (cTnI) detection, the proposed system shortened the incubation duration and reduced the coefficient of variation from 10.77% to 2.69%. This work addresses the key bottleneck restricting precise temperature control in microfluidic chemiluminescence analyzers, which provides robust technical support for the development of next-generation high-performance POCT instruments.
- Open Access
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 4288-4301
ECG-Based Energy Expenditure Prediction Using BiLSTM With Improved Snow Ablation Optimizer
Accurately estimating energy expenditure (EE) is essential for optimizing motion control strategies in human-in-the-loop (HIL) systems within the field of human-machine interface (HMI). This study aims to propose a method for accurately estimating EE under various movement conditions using a low-cost wearable electrocardiogram (ECG) device and to analyze the impact of various factors on the estimation results. In this study, we introduce an improved snow ablation optimizer (ISAO) to optimize the hyperparameters and input time series window length in a BiLSTM network for predicting EE under diverse motion conditions. ISAO adaptively adjusts the search strategy during different optimization stages by analyzing fitness changes throughout the iterative process. Additionally, the optimized input data window length considers both high-frequency ECG signals and low-frequency EE data collected using the breath-by-breath method, thus avoiding errors from empirical selection. After offline model training, we evaluated the model using test sets comprising multiple time intervals generated by the optimized window length, simulating real online testing scenarios. Experimental results demonstrate that the proposed ISAO-BiLSTM network structure can accurately predict EE across various motion paradigms (RMSE: 56 W; R²: 0.93). This study verifies that the ECG-based deep learning framework has more accurate EE predictions across various motion paradigms compared to those based on heart rate (HR) signals. Additionally, the optimized input data window length is expected to be valuable for real-time EE predictions in HIL HMI applications, as current closed-loop optimization strategies primarily rely on outputting an EE value within a specific time window.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 4288-4301
Open AccessECG-Based Energy Expenditure Prediction Using BiLSTM With Improved Snow Ablation Optimizer
Accurately estimating energy expenditure (EE) is essential for optimizing motion control strategies in human-in-the-loop (HIL) systems within the field of human-machine interface (HMI). This study aims to propose a method for accurately estimating EE under various movement conditions using a low-cost wearable electrocardiogram (ECG) device and to analyze the impact of various factors on the estimation results. In this study, we introduce an improved snow ablation optimizer (ISAO) to optimize the hyperparameters and input time series window length in a BiLSTM network for predicting EE under diverse motion conditions. ISAO adaptively adjusts the search strategy during different optimization stages by analyzing fitness changes throughout the iterative process. Additionally, the optimized input data window length considers both high-frequency ECG signals and low-frequency EE data collected using the breath-by-breath method, thus avoiding errors from empirical selection. After offline model training, we evaluated the model using test sets comprising multiple time intervals generated by the optimized window length, simulating real online testing scenarios. Experimental results demonstrate that the proposed ISAO-BiLSTM network structure can accurately predict EE across various motion paradigms (RMSE: 56 W; R²: 0.93). This study verifies that the ECG-based deep learning framework has more accurate EE predictions across various motion paradigms compared to those based on heart rate (HR) signals. Additionally, the optimized input data window length is expected to be valuable for real-time EE predictions in HIL HMI applications, as current closed-loop optimization strategies primarily rely on outputting an EE value within a specific time window.
- Open Access
- 10 April 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 242, 108092
A wearable ring oximeter for detection of sleep disordered breathing
- 10 April 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 242, 108092
Open AccessA wearable ring oximeter for detection of sleep disordered breathing
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4109-4120
Personalized Continuous Blood Pressure Tracking Through Single Channel PPG in Wearable Scenarios
The real-time tracking of human physiopathology states can significantly enhance the quality of personalized healthcare services. Photoplethysmography (PPG) detection is a rapid, portable and non-invasive method for measuring blood flow volume, widely used for monitoring blood pressure (BP) and cardiovascular status. However, continuous BP monitoring technologies based on PPG face numerous challenges in real-world wearable scenarios, such as poor signal quality, complex model computation, and the need for frequent calibration. This work proposed a personalized continuous BP tracking pipeline that performed automatic PPG signal quality grading to reduce the difficulty of model fitting, introduced a lightweight BP model (SCI-GTCN) to alleviate computational complexity, and employed an adaptive calibration strategy to achieve long-term BP monitoring performance under different scenarios. The proposed pipeline was validated using data from 134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states), assessing the model's performance during rapid BP changes, circadian rhythm fluctuations, and long-term monitoring. The ME±SD was 0.99±7.91/0.36±5.43 mmHg. Overall, the results of our method are within the accuracy requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards, though the subject distribution differs. The method demonstrated good robustness and applicability, making it convenient for deployment on wearable devices and promising in the healthcare field.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 29 (6) , 4109-4120
Personalized Continuous Blood Pressure Tracking Through Single Channel PPG in Wearable Scenarios
The real-time tracking of human physiopathology states can significantly enhance the quality of personalized healthcare services. Photoplethysmography (PPG) detection is a rapid, portable and non-invasive method for measuring blood flow volume, widely used for monitoring blood pressure (BP) and cardiovascular status. However, continuous BP monitoring technologies based on PPG face numerous challenges in real-world wearable scenarios, such as poor signal quality, complex model computation, and the need for frequent calibration. This work proposed a personalized continuous BP tracking pipeline that performed automatic PPG signal quality grading to reduce the difficulty of model fitting, introduced a lightweight BP model (SCI-GTCN) to alleviate computational complexity, and employed an adaptive calibration strategy to achieve long-term BP monitoring performance under different scenarios. The proposed pipeline was validated using data from 134 subjects in various monitoring scenarios (daytime, nighttime, and abnormal states), assessing the model's performance during rapid BP changes, circadian rhythm fluctuations, and long-term monitoring. The ME±SD was 0.99±7.91/0.36±5.43 mmHg. Overall, the results of our method are within the accuracy requirements of the Association for the Advancement of Medical Instrumentation (AAMI) standards, though the subject distribution differs. The method demonstrated good robustness and applicability, making it convenient for deployment on wearable devices and promising in the healthcare field.
- Open Access
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 4063-4075
Synergy-Based Estimation of Balance Condition During Walking Tests
In the area of human-machine interface research, the continuous estimation of the Center of Pressure (COP) in the human body can assess users’ balance conditions, thereby effectively enhancing the safety and diversity of studies. This paper aims to present a novel method for continuous synergy-based estimation of human balance states during walking, and simultaneously analyze the impact of various factors on the estimation results. Specifically, we introduce muscle synergy coherence features and analyze the variations of these features in different balance conditions. Furthermore, we fuse temporal features extracted by a bidirectional long short-term memory (BILSTM) network with spatial features derived from the analysis of muscle synergy coherence to continuously estimate the mediolateral COP and Ground Reaction Force (GRF) during human walking tests. Then, we analyze the influence of different electromechanical delay compensation (EMD) time, the number of synergies, and different walking speeds on the estimation results. Finally, we validate the estimation capability of the proposed method on data collected in real-world walking tests. The results indicate a significant correlation between the proposed muscle synergy coherence features and balance conditions. The network structure combining muscle synergy coherence features and BILSTM features enables accurate continuous estimation of COP ( R 2 =0.87±0.07) and GRF ( R 2 =0.83±0.09) during walking tests. Our research introduces a novel approach to the continuous estimation of balance conditions in human walking, with potential implications in various applications within human-machine engineering, such as exoskeletons and prosthetics.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 4063-4075
Open AccessSynergy-Based Estimation of Balance Condition During Walking Tests
In the area of human-machine interface research, the continuous estimation of the Center of Pressure (COP) in the human body can assess users’ balance conditions, thereby effectively enhancing the safety and diversity of studies. This paper aims to present a novel method for continuous synergy-based estimation of human balance states during walking, and simultaneously analyze the impact of various factors on the estimation results. Specifically, we introduce muscle synergy coherence features and analyze the variations of these features in different balance conditions. Furthermore, we fuse temporal features extracted by a bidirectional long short-term memory (BILSTM) network with spatial features derived from the analysis of muscle synergy coherence to continuously estimate the mediolateral COP and Ground Reaction Force (GRF) during human walking tests. Then, we analyze the influence of different electromechanical delay compensation (EMD) time, the number of synergies, and different walking speeds on the estimation results. Finally, we validate the estimation capability of the proposed method on data collected in real-world walking tests. The results indicate a significant correlation between the proposed muscle synergy coherence features and balance conditions. The network structure combining muscle synergy coherence features and BILSTM features enables accurate continuous estimation of COP ( R 2 =0.87±0.07) and GRF ( R 2 =0.83±0.09) during walking tests. Our research introduces a novel approach to the continuous estimation of balance conditions in human walking, with potential implications in various applications within human-machine engineering, such as exoskeletons and prosthetics.
- Open Access
- 30 September 2024
- Published by MDPI AG in Magnetochemistry
- Vol. 10 (10) , 75
Optimizing Magnetic Separation and Cleaning Module in Fully Automated Chemiluminescence Immunoassay Analyzer Using a Special Arrangement of Spliced Magnets and a Three-Stage Magnetic Bead Collection Method
The magnetic separation and cleaning module, as a core component of the fully automated chemiluminescence immunoassay (CLIA) analyzer, encounters issues including high magnetic bead loss rate, long cleaning time, and poor cleaning effect. Based on a simulation analysis using COMSOL, we proposed a novel magnetic separation and cleaning module applied to a fully automated CLIA analyzer. The module adopted a method of arranging spliced rectangular magnets on opposite sides, where the same polarity faced each other, as well as a three-stage magnetic bead collection method. With the proposed method, the total cleaning process can be accomplished within 225 s; the total magnetic bead loss rate over three rounds of cleaning is 6.03%, whereas that of traditional instruments is 25.85%; the coefficient of variation (CV) of the magnetic bead loss rate is less than 0.5%; effective cleaning of free markers is achieved under various sample conditions. Compared with traditional CLIA instruments, this method comprehensively improves key performance indicators of the magnetic separation and cleaning module, providing a reference for similar modules in fully automated CLIA analyzers and positively impacting the accuracy of CLIA for the detection of disease biomarkers.
- 30 September 2024
- Published by MDPI AG in Magnetochemistry
- Vol. 10 (10) , 75
Open AccessOptimizing Magnetic Separation and Cleaning Module in Fully Automated Chemiluminescence Immunoassay Analyzer Using a Special Arrangement of Spliced Magnets and a Three-Stage Magnetic Bead Collection Method
The magnetic separation and cleaning module, as a core component of the fully automated chemiluminescence immunoassay (CLIA) analyzer, encounters issues including high magnetic bead loss rate, long cleaning time, and poor cleaning effect. Based on a simulation analysis using COMSOL, we proposed a novel magnetic separation and cleaning module applied to a fully automated CLIA analyzer. The module adopted a method of arranging spliced rectangular magnets on opposite sides, where the same polarity faced each other, as well as a three-stage magnetic bead collection method. With the proposed method, the total cleaning process can be accomplished within 225 s; the total magnetic bead loss rate over three rounds of cleaning is 6.03%, whereas that of traditional instruments is 25.85%; the coefficient of variation (CV) of the magnetic bead loss rate is less than 0.5%; effective cleaning of free markers is achieved under various sample conditions. Compared with traditional CLIA instruments, this method comprehensively improves key performance indicators of the magnetic separation and cleaning module, providing a reference for similar modules in fully automated CLIA analyzers and positively impacting the accuracy of CLIA for the detection of disease biomarkers.
- 7 September 2024
- Published by Elsevier in Measurement
- Vol. 241
Core body temperature estimation model with thermal contact resistance compensation
- 7 September 2024
- Published by Elsevier in Measurement
- Vol. 241
Core body temperature estimation model with thermal contact resistance compensation
- 1 September 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (9) , 095016
Template-based synergy extrapolation analysis for prediction of muscle excitations
Objective. Accurate prediction of unmeasured muscle excitations can reduce the required wearable surface electromyography (sEMG) sensors, which is a critical factor in the study of physiological measurement. Synergy extrapolation uses synergy excitations as building blocks to reconstruct muscle excitations. However, the practical application of synergy extrapolation is still limited as the extrapolation process utilizes unmeasured muscle excitations it seeks to reconstruct. This paper aims to propose and derive methods to provide an avenue for the practical application of synergy extrapolation with non-negative matrix factorization (NMF) methods. Approach. Specifically, a tunable Gaussian–Laplacian mixture distribution NMF (GLD-NMF) method and related multiplicative update rules are derived to yield appropriate synergy excitations for extrapolation. Furthermore, a template-based extrapolation structure (TBES) is proposed to extrapolate unmeasured muscle excitations based on synergy weighting matrix templates totally extracted from measured sEMG datasets, improving the extrapolation performance. Moreover, we applied the proposed GLD-NMF method and TBES to selected muscle excitations acquired from a series of single-leg stance tests, walking tests and upper limb reaching tests. Main results. Experimental results show that the proposed GLD-NMF and TBES could extrapolate unmeasured muscle excitations accurately. Moreover, introducing synergy weighting matrix templates could decrease the number of sEMG sensors in a series of experiments. In addition, verification results demonstrate the feasibility of applying synergy extrapolation with NMF methods. Significance. With the TBES method, synergy extrapolation could play a significant role in reducing data dimensions of sEMG sensors, which will improve the portability of sEMG sensors-based systems and promotes applications of sEMG signals in human–machine interfaces scenarios.
- 1 September 2024
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (9) , 095016
Template-based synergy extrapolation analysis for prediction of muscle excitations
Objective. Accurate prediction of unmeasured muscle excitations can reduce the required wearable surface electromyography (sEMG) sensors, which is a critical factor in the study of physiological measurement. Synergy extrapolation uses synergy excitations as building blocks to reconstruct muscle excitations. However, the practical application of synergy extrapolation is still limited as the extrapolation process utilizes unmeasured muscle excitations it seeks to reconstruct. This paper aims to propose and derive methods to provide an avenue for the practical application of synergy extrapolation with non-negative matrix factorization (NMF) methods. Approach. Specifically, a tunable Gaussian–Laplacian mixture distribution NMF (GLD-NMF) method and related multiplicative update rules are derived to yield appropriate synergy excitations for extrapolation. Furthermore, a template-based extrapolation structure (TBES) is proposed to extrapolate unmeasured muscle excitations based on synergy weighting matrix templates totally extracted from measured sEMG datasets, improving the extrapolation performance. Moreover, we applied the proposed GLD-NMF method and TBES to selected muscle excitations acquired from a series of single-leg stance tests, walking tests and upper limb reaching tests. Main results. Experimental results show that the proposed GLD-NMF and TBES could extrapolate unmeasured muscle excitations accurately. Moreover, introducing synergy weighting matrix templates could decrease the number of sEMG sensors in a series of experiments. In addition, verification results demonstrate the feasibility of applying synergy extrapolation with NMF methods. Significance. With the TBES method, synergy extrapolation could play a significant role in reducing data dimensions of sEMG sensors, which will improve the portability of sEMG sensors-based systems and promotes applications of sEMG signals in human–machine interfaces scenarios.