Haijing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haijing Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Chengxiong Mao
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Dan Wang
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Jinli Zhu
Department of Electrical and Computer Engineering, University of Pittsburgh, Pittsburgh, PA, USA
2 shared publications - Zhaoyuan Wang
Department of Electrical and Electronic Engineering, The Hong Kong Polytechnic University, 11 Yuk Choi Rd, Hong Kong
2 shared publications - Bin Liu
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
1 shared publication Hong Lu
Electric Power Research Inst. of Guangdong Power Grid Corp., Guangzhou, 510080, China
1 shared publication
Latest Publications
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (8) , 7560-7570
Design and Field Application of DC and Harmonic Suppression System for Neutral Current in 220 kV Substation
Recently, the grounding system of substation has been seriously invaded by earth current generated by flourishing urban rail transit network. The invasion leads to abnormal vibration of transformer and even some electrical safety problems. This article presents a dc and harmonic current suppression system (DHSS) applied to the neutral point of transformer. The design and development of the DHSS are described in detail. The power circuit is designed as a segmented structure with dc current blocking and harmonic current suppression. The high-speed bypass protection circuit is implemented to ensure the reliable grounding of neutral point in any case. The matching control and protection system is developed. The proposed controller for suppressing harmonic current is applicable for the neutral point and meets the requirements of relay protection. The design details and difficulties are discussed. The development, commissioning, and experiment are completed in the laboratory. The developed prototype has been subjected to high current impulse tests. The performance and reliability are verified by the presented results. This prototype is running on-site in a 220 kV substation.
- 19 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (8) , 7560-7570
Design and Field Application of DC and Harmonic Suppression System for Neutral Current in 220 kV Substation
Recently, the grounding system of substation has been seriously invaded by earth current generated by flourishing urban rail transit network. The invasion leads to abnormal vibration of transformer and even some electrical safety problems. This article presents a dc and harmonic current suppression system (DHSS) applied to the neutral point of transformer. The design and development of the DHSS are described in detail. The power circuit is designed as a segmented structure with dc current blocking and harmonic current suppression. The high-speed bypass protection circuit is implemented to ensure the reliable grounding of neutral point in any case. The matching control and protection system is developed. The proposed controller for suppressing harmonic current is applicable for the neutral point and meets the requirements of relay protection. The design details and difficulties are discussed. The development, commissioning, and experiment are completed in the laboratory. The developed prototype has been subjected to high current impulse tests. The performance and reliability are verified by the presented results. This prototype is running on-site in a 220 kV substation.
- Open Access
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 1079-1089
Suppression strategy for rail transit ground current in transformer neutral points
- 1 December 2020
- Published by Elsevier in Energy Reports
- Vol. 6, 1079-1089
Open AccessSuppression strategy for rail transit ground current in transformer neutral points
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 34, 1-4
Experimental investigation of partial discharge detection in medium-voltage switchgear based on Ultra-High-Frequency sensor
Partial discharge (PD) detection is the important research topic in the safe operation of electric equipment and power grid. Experimental investigation of partial discharge detection was carried out in a 12 kV switchgear by Ultra-High-Frequency (UHF) method. Two kinds of typical artificial fault models, namely suspended-metal model and voids-in-dielectric model were used as discharge sources. The UHF antenna was placed in the vicinity of joints for better capture efficiency. High-voltage probe was used to synchronize with the input voltage wave form, which determined the phase distributions of different defect models. Signal's amplitude rose with the increasing of input voltage till fully breaking down resulting in fatal damages to discharge models. Relations between the models' dimensions and discharge amplitude were also investigated. Further study focused on the frequency spectrums of these discharge signals. It revealed that the signal's frequency components were located mainly in less than 200 MHz and 520 MHz~540 MHz. These results might contribute to a better understanding of partial discharge detection by UHF method.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 34, 1-4
Experimental investigation of partial discharge detection in medium-voltage switchgear based on Ultra-High-Frequency sensor
Partial discharge (PD) detection is the important research topic in the safe operation of electric equipment and power grid. Experimental investigation of partial discharge detection was carried out in a 12 kV switchgear by Ultra-High-Frequency (UHF) method. Two kinds of typical artificial fault models, namely suspended-metal model and voids-in-dielectric model were used as discharge sources. The UHF antenna was placed in the vicinity of joints for better capture efficiency. High-voltage probe was used to synchronize with the input voltage wave form, which determined the phase distributions of different defect models. Signal's amplitude rose with the increasing of input voltage till fully breaking down resulting in fatal damages to discharge models. Relations between the models' dimensions and discharge amplitude were also investigated. Further study focused on the frequency spectrums of these discharge signals. It revealed that the signal's frequency components were located mainly in less than 200 MHz and 520 MHz~540 MHz. These results might contribute to a better understanding of partial discharge detection by UHF method.