Susanne Weber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Susanne Weber has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Peter B. Luppa
Institut für Klinische Chemie und Pathobiochemie, Klinikum rechts der Isar der TU München , Munich , Germany
3 shared publications - Alexander M. Herrmann
Department of Neurology, Institute of Translational Neurology, University of Münster, D-48149 Münster, Germany
1 shared publication Ambra Giannetti
Institute of Applied Physics “Nello Carrara”, National Research Council , Sesto Fiorentino (FI) , Italy
1 shared publicationAmélie F. Menke
Department of Neurology, Institute of Translational Neurology, University of Münster, D-48149 Münster, Germany
1 shared publicationAna B. Descalzo
Department of Organic Chemistry , Universidad Complutense de Madrid , Madrid , Spain
1 shared publication- Andreas Bietenbeck
MVZ Ärztliche Laboratorien München-Land GmbH , Poing , Germany
1 shared publication
Latest Publications
- Open Access
- 27 April 2026
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 11 (2) , 247-256
Blood gas analyzers enable reliable measurement of synovial pH, lactate, and glucose in native and periprosthetic joint infection: an analytical agreement study
Background: Synovial pH, lactate, and glucose are established biomarkers for septic arthritis in native joints and have emerging utility in periprosthetic joint infection (PJI). In routine care, these biomarkers are commonly analyzed in central laboratories, which may delay clinical decision-making. Blood gas analyzers (BGAs), which can also measure these parameters, are widely available at the point of care, and their use could accelerate decision-making. However, BGAs are not validated for synovial fluid analysis. Materials and methods: This prospective analytical agreement study included 35 consecutive patients undergoing knee joint aspiration for suspected PJI or septic arthritis of the native joint. Each sample was measured in triplicate both in the central laboratory and using a BGA. The agreement between the two methods was assessed using Passing–Bablok and Bland–Altman analyses. The study was designed to assess analytical agreement between both methods rather than diagnostic accuracy. Results: BGA measurements for synovial pH, lactate, and glucose demonstrated good to excellent agreement with those obtained using central laboratory methods. Agreement was excellent for synovial glucose and overall good for lactate, with negligible mean bias. Linear regression showed very strong correlations for glucose (r= 0.997) and lactate (r= 0.989). Synovial pH showed greater variability, with a mean bias of −0.10 pH units; however, repeatability analysis revealed lower within-sample variability for BGA-based pH measurements compared with laboratory pH measurements. Conclusion: BGAs enable rapid, reliable measurement of synovial pH, lactate, and glucose from small sample volumes and may support timely clinical decision-making in suspected septic arthritis and PJI. Further studies should assess inter-device generalizability and establish device-specific reference ranges.
- 27 April 2026
- Published by Copernicus GmbH in Journal of Bone and Joint Infection
- Vol. 11 (2) , 247-256
Open AccessBlood gas analyzers enable reliable measurement of synovial pH, lactate, and glucose in native and periprosthetic joint infection: an analytical agreement study
Background: Synovial pH, lactate, and glucose are established biomarkers for septic arthritis in native joints and have emerging utility in periprosthetic joint infection (PJI). In routine care, these biomarkers are commonly analyzed in central laboratories, which may delay clinical decision-making. Blood gas analyzers (BGAs), which can also measure these parameters, are widely available at the point of care, and their use could accelerate decision-making. However, BGAs are not validated for synovial fluid analysis. Materials and methods: This prospective analytical agreement study included 35 consecutive patients undergoing knee joint aspiration for suspected PJI or septic arthritis of the native joint. Each sample was measured in triplicate both in the central laboratory and using a BGA. The agreement between the two methods was assessed using Passing–Bablok and Bland–Altman analyses. The study was designed to assess analytical agreement between both methods rather than diagnostic accuracy. Results: BGA measurements for synovial pH, lactate, and glucose demonstrated good to excellent agreement with those obtained using central laboratory methods. Agreement was excellent for synovial glucose and overall good for lactate, with negligible mean bias. Linear regression showed very strong correlations for glucose (r= 0.997) and lactate (r= 0.989). Synovial pH showed greater variability, with a mean bias of −0.10 pH units; however, repeatability analysis revealed lower within-sample variability for BGA-based pH measurements compared with laboratory pH measurements. Conclusion: BGAs enable rapid, reliable measurement of synovial pH, lactate, and glucose from small sample volumes and may support timely clinical decision-making in suspected septic arthritis and PJI. Further studies should assess inter-device generalizability and establish device-specific reference ranges.
- 1 January 2025
- Published by Springer Nature
- p. 123-138
Molekularbiologische Testungen
- 1 January 2025
- Published by Springer Nature
- p. 105-121
Immunologische Verfahren
- Open Access
- 4 January 2024
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 22 (4) , 1187-1201
Recombinantly Expressed Tagged SUrface Protein (RETSUP) assay: a new diagnostic system for the detection of antibodies to platelets
- 4 January 2024
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 22 (4) , 1187-1201
Open AccessRecombinantly Expressed Tagged SUrface Protein (RETSUP) assay: a new diagnostic system for the detection of antibodies to platelets
- Open Access
- 26 January 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (7) , 1255-1265
Surface plasmon resonance assays for the therapeutic drug monitoring of infliximab indicate clinical relevance of anti-infliximab antibody binding properties
Objectives: The therapeutic antibody infliximab (IFX) has improved the life quality of numerous autoinflammatory disease patients. However, IFX can trigger the generation of anti-drug antibodies (ADA), whose optimal evaluation and management are currently subject of controversial discussions. We present two novel surface plasmon resonance (SPR) biosensor assays for therapeutic drug monitoring of IFX and characterization of ADA and investigated the diagnostic value of ADA binding properties. Methods: IFX and ADA were quantified via developed SPR biosensor assays (IFXmon and ADAmon, respectively) and diagnostics-approved ELISA in sera from inflammatory bowel disease patients. Pre-analytic ADA enrichment with magnetic beads enabled analytical drug tolerance of the ADAmon assay. The dissociation ratio (DissR) as an index for ADA:IFX binding stability was calculated from the SPR sensorgrams of ADA quantification runs. Results: IFX levels determined by IFXmon assay and ELISA showed high agreement, whereas ADA quantification concordance between ADAmon assay and ELISA was poor. In patients, DissR was predominantly constant over time and differed significantly between therapy outcomes. A DissR cut-off of 1.524 indicated undetectable IFX levels with 71.4% sensitivity and 88.9% specificity. Additionally, the SPR reference surface was exploited as serum-individual negative control to check result plausibility within multi-sample run sequences. Conclusions: Overall, both SPR biosensor assays exhibited reliable quantitative performance with accuracies superior to their ELISA counterparts and precision inferior to ELISA only for ADAmon. DissR presented itself as promising ADA binding parameter and could contribute to both earlier and more tailored therapeutic decisions.
- 26 January 2023
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (7) , 1255-1265
Open AccessSurface plasmon resonance assays for the therapeutic drug monitoring of infliximab indicate clinical relevance of anti-infliximab antibody binding properties
Objectives: The therapeutic antibody infliximab (IFX) has improved the life quality of numerous autoinflammatory disease patients. However, IFX can trigger the generation of anti-drug antibodies (ADA), whose optimal evaluation and management are currently subject of controversial discussions. We present two novel surface plasmon resonance (SPR) biosensor assays for therapeutic drug monitoring of IFX and characterization of ADA and investigated the diagnostic value of ADA binding properties. Methods: IFX and ADA were quantified via developed SPR biosensor assays (IFXmon and ADAmon, respectively) and diagnostics-approved ELISA in sera from inflammatory bowel disease patients. Pre-analytic ADA enrichment with magnetic beads enabled analytical drug tolerance of the ADAmon assay. The dissociation ratio (DissR) as an index for ADA:IFX binding stability was calculated from the SPR sensorgrams of ADA quantification runs. Results: IFX levels determined by IFXmon assay and ELISA showed high agreement, whereas ADA quantification concordance between ADAmon assay and ELISA was poor. In patients, DissR was predominantly constant over time and differed significantly between therapy outcomes. A DissR cut-off of 1.524 indicated undetectable IFX levels with 71.4% sensitivity and 88.9% specificity. Additionally, the SPR reference surface was exploited as serum-individual negative control to check result plausibility within multi-sample run sequences. Conclusions: Overall, both SPR biosensor assays exhibited reliable quantitative performance with accuracies superior to their ELISA counterparts and precision inferior to ELISA only for ADAmon. DissR presented itself as promising ADA binding parameter and could contribute to both earlier and more tailored therapeutic decisions.
- 22 February 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (9)
Cross-reactivity of a pathogenic autoantibody to a tumor antigen in GABA A receptor encephalitis
Significance: Antibodies recognizing the neuronal gamma-aminobutyric acid A receptor (GABA A -R) cause severe encephalitis by triggering internalization of the antibody–receptor complexes in inhibitory synapses, which leads to hyperexcitability and dysfunction of neuronal networks. From the cerebrospinal fluid of a patient with GABA A -R encephalitis we cloned a highly expressed antibody and showed that it binds the GABA A -R and influences signal transduction in neurons, explaining clinical symptoms. Using several experimental techniques, we confirmed that the antibody cross-reacts to an oncoprotein which is known to be involved in several malignancies. We showed that cross-reactivity to this oncoprotein may also be detected in two other GABA A -R patients, suggesting that such cross-reactivity is presumably a key event in the pathogenesis of GABA A -R encephalitis.
- 22 February 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (9)
Cross-reactivity of a pathogenic autoantibody to a tumor antigen in GABA A receptor encephalitis
Significance: Antibodies recognizing the neuronal gamma-aminobutyric acid A receptor (GABA A -R) cause severe encephalitis by triggering internalization of the antibody–receptor complexes in inhibitory synapses, which leads to hyperexcitability and dysfunction of neuronal networks. From the cerebrospinal fluid of a patient with GABA A -R encephalitis we cloned a highly expressed antibody and showed that it binds the GABA A -R and influences signal transduction in neurons, explaining clinical symptoms. Using several experimental techniques, we confirmed that the antibody cross-reacts to an oncoprotein which is known to be involved in several malignancies. We showed that cross-reactivity to this oncoprotein may also be detected in two other GABA A -R patients, suggesting that such cross-reactivity is presumably a key event in the pathogenesis of GABA A -R encephalitis.
- 4 December 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 59 (5) , 935-945
Immunosuppressant quantification in intravenous microdialysate – towards novel quasi-continuous therapeutic drug monitoring in transplanted patients
Objectives: Therapeutic drug monitoring (TDM) plays a crucial role in personalized medicine. It helps clinicians to tailor drug dosage for optimized therapy through understanding the underlying complex pharmacokinetics and pharmacodynamics. Conventional, non-continuous TDM fails to provide real-time information, which is particularly important for the initial phase of immunosuppressant therapy, e.g., with cyclosporine (CsA) and mycophenolic acid (MPA). Methods: We analyzed the time course over 8 h of total and free of immunosuppressive drug (CsA and MPA) concentrations measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 16 kidney transplant patients. Besides repeated blood sampling, intravenous microdialysis was used for continuous sampling. Free drug concentrations were determined from ultracentrifuged EDTA-plasma (UC) and compared with the drug concentrations in the respective microdialysate (µD). µDs were additionally analyzed for free CsA using a novel immunosensor chip integrated into a fluorescence detection platform. The potential of microdialysis coupled with an optical immunosensor for the TDM of immunosuppressants was assessed. Results: Using LC-MS/MS, the free concentrations of CsA (fCsA) and MPA (fMPA) were detectable and the time courses of total and free CsA comparable. fCsA and fMPA and area-under-the-curves (AUCs) in µDs correlated well with those determined in UCs (r≥0.79 and r≥0.88, respectively). Moreover, fCsA in µDs measured with the immunosensor correlated clearly with those determined by LC-MS/MS (r=0.82). Conclusions: The new microdialysis-supported immunosensor allows real-time analysis of immunosuppressants and tailor-made dosing according to the AUC concept. It readily lends itself to future applications as minimally invasive and continuous near-patient TDM.
- 4 December 2020
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 59 (5) , 935-945
Immunosuppressant quantification in intravenous microdialysate – towards novel quasi-continuous therapeutic drug monitoring in transplanted patients
Objectives: Therapeutic drug monitoring (TDM) plays a crucial role in personalized medicine. It helps clinicians to tailor drug dosage for optimized therapy through understanding the underlying complex pharmacokinetics and pharmacodynamics. Conventional, non-continuous TDM fails to provide real-time information, which is particularly important for the initial phase of immunosuppressant therapy, e.g., with cyclosporine (CsA) and mycophenolic acid (MPA). Methods: We analyzed the time course over 8 h of total and free of immunosuppressive drug (CsA and MPA) concentrations measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in 16 kidney transplant patients. Besides repeated blood sampling, intravenous microdialysis was used for continuous sampling. Free drug concentrations were determined from ultracentrifuged EDTA-plasma (UC) and compared with the drug concentrations in the respective microdialysate (µD). µDs were additionally analyzed for free CsA using a novel immunosensor chip integrated into a fluorescence detection platform. The potential of microdialysis coupled with an optical immunosensor for the TDM of immunosuppressants was assessed. Results: Using LC-MS/MS, the free concentrations of CsA (fCsA) and MPA (fMPA) were detectable and the time courses of total and free CsA comparable. fCsA and fMPA and area-under-the-curves (AUCs) in µDs correlated well with those determined in UCs (r≥0.79 and r≥0.88, respectively). Moreover, fCsA in µDs measured with the immunosensor correlated clearly with those determined by LC-MS/MS (r=0.82). Conclusions: The new microdialysis-supported immunosensor allows real-time analysis of immunosuppressants and tailor-made dosing according to the AUC concept. It readily lends itself to future applications as minimally invasive and continuous near-patient TDM.
- 1 October 2017
- Published by Elsevier in Chemico-Biological Interactions
- Vol. 276, 182-193
Characterization of AKR1B16, a novel mouse aldo-keto reductase
- 1 October 2017
- Published by Elsevier in Chemico-Biological Interactions
- Vol. 276, 182-193
Characterization of AKR1B16, a novel mouse aldo-keto reductase