Monika Reddy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Monika Reddy has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Nick Oliver
Department of Metabolism, Digestion and Reproduction Imperial College London London UK
23 shared publications - Pau Herrero
Roche Diagnostics SL, Barcelona, Spain
11 shared publications - Pantelis Georgiou
Centre for Bio-Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, U.K.
9 shared publications - Parizad Avari
Department of Metabolism, Digestion and Reproduction, Imperial College London, London, United Kingdom
9 shared publications Narvada Jugnee
Department of Metabolism, Digestion and Reproduction, Imperial College London, London, United Kingdom
6 shared publicationsChristofer Toumazou
Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Institute of Biomedical Engineering , Imperial College London, London, United Kingdom
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Wiley in Diabetes, Obesity and Metabolism
A Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes
Aims: The continuous glucose monitoring (CGM)‐derived glucose management indicator (GMI) is used for estimating glycated haemoglobin (HbA1c). This study assessed agreement between GMI—calculated using both original and updated (uGMI) models—and laboratory‐measured HbA1c across Dexcom, MiniMed and Abbott sensors. Materials and Methods: Real‐world data from adults with type 1 diabetes using automated insulin delivery were retrospectively analysed. Δ(GMI‐HbA1c) and Δ(uGMI‐HbA1c) were evaluated over 90 days preceding HbA1c ( n = 383) and over 28 days preceding HbA1c ( n = 375). Agreement was measured as directional difference, indicating GMI overestimation or underestimation of HbA1c, and absolute difference, indicating magnitude of agreement between GMI and HbA1c. Agreement was assessed across sensor groups using ANCOVA, adjusting for coefficient of variation and ethnicity. Results: Although mean directional differences were statistically significant for Δ(GMI‐HbA1c) and Δ(uGMI‐HbA1c) across all sensor groups ( p < 0.001), differences were small and not clinically important, 90‐day adjusted means (95% CI)—Δ(GMI‐HbA1c): Dexcom 0.17% (0.09, 0.25), MiniMed −0.15% (−0.28, −0.02), Abbott −0.08% (−0.25, 0.09); Δ(uGMI‐HbA1c): Dexcom 0.22% (0.14, 0.30), MiniMed −0.10% (−0.23, 0.02), Abbott −0.02% (−0.19, 0.15). Mean absolute difference did not significantly differ across sensor groups—Δ(GMI‐HbA1c): 0.42%–0.51% ( p = 0.353), Δ(uGMI‐HbA1c): 0.41%–0.52% ( p = 0.221). Conclusions: GMI/uGMI performed consistently across sensor groups. Where clinically meaningful discrepancies between GMI/uGMI and HbA1c arise, these warrant interpretation within the context of individual clinical and laboratory factors rather than attribution to sensor manufacturer, reinforcing the need for personalised use of GMI alongside HbA1c.
- 27 October 2026
- Published by Wiley in Diabetes, Obesity and Metabolism
Open AccessA Comparative Analysis Between Original and Updated Glucose Management Indicator and Glycated Haemoglobin Across Continuous Glucose Monitoring Sensors in Type 1 Diabetes
Aims: The continuous glucose monitoring (CGM)‐derived glucose management indicator (GMI) is used for estimating glycated haemoglobin (HbA1c). This study assessed agreement between GMI—calculated using both original and updated (uGMI) models—and laboratory‐measured HbA1c across Dexcom, MiniMed and Abbott sensors. Materials and Methods: Real‐world data from adults with type 1 diabetes using automated insulin delivery were retrospectively analysed. Δ(GMI‐HbA1c) and Δ(uGMI‐HbA1c) were evaluated over 90 days preceding HbA1c ( n = 383) and over 28 days preceding HbA1c ( n = 375). Agreement was measured as directional difference, indicating GMI overestimation or underestimation of HbA1c, and absolute difference, indicating magnitude of agreement between GMI and HbA1c. Agreement was assessed across sensor groups using ANCOVA, adjusting for coefficient of variation and ethnicity. Results: Although mean directional differences were statistically significant for Δ(GMI‐HbA1c) and Δ(uGMI‐HbA1c) across all sensor groups ( p < 0.001), differences were small and not clinically important, 90‐day adjusted means (95% CI)—Δ(GMI‐HbA1c): Dexcom 0.17% (0.09, 0.25), MiniMed −0.15% (−0.28, −0.02), Abbott −0.08% (−0.25, 0.09); Δ(uGMI‐HbA1c): Dexcom 0.22% (0.14, 0.30), MiniMed −0.10% (−0.23, 0.02), Abbott −0.02% (−0.19, 0.15). Mean absolute difference did not significantly differ across sensor groups—Δ(GMI‐HbA1c): 0.42%–0.51% ( p = 0.353), Δ(uGMI‐HbA1c): 0.41%–0.52% ( p = 0.221). Conclusions: GMI/uGMI performed consistently across sensor groups. Where clinically meaningful discrepancies between GMI/uGMI and HbA1c arise, these warrant interpretation within the context of individual clinical and laboratory factors rather than attribution to sensor manufacturer, reinforcing the need for personalised use of GMI alongside HbA1c.
- Open Access
- 12 February 2026
- Published by Wiley in Diabetic Medicine
- Vol. 43 (5) , e70251
Real‐world glycaemic outcomes observed with the use of Medtronic 780G , Tandem Control‐ IQ and Omnipod 5 automated insulin delivery systems
Background: No randomised controlled trials have directly compared commercially available hybrid automated insulin delivery (AID) systems, and real‐world comparative data remain limited. This study evaluated glycaemic outcomes across three hybrid AID systems in adults with type 1 diabetes (T1D). Methods: This was a retrospective, observational, single‐centre study and included adults with T1D who transitioned from multiple daily injections (MDI) or non‐automated insulin pump therapy to hybrid AID. Data were collected from routinely used clinical data‐sharing platforms and electronic health records. Outcomes compared across systems included time in range (TIR; 3.9–10.0 mmol/L), time below range (TBR; 13.9 mmol/L), glucose management indicator (GMI, %) and coefficient of variation (CV, %). Results: A total of 213 participants were included (Medtronic 780G n = 38; Tandem Control‐IQ n = 81; Omnipod 5 n = 94). After adjustment for baseline TIR, diabetes duration, insulin modality and AID use duration 780G users achieved a higher TIR increase (21.1% [95% CI 18.4–23.7]) compared to Control‐IQ (10.1% [3.2–17.3], p = 0.010) and Omnipod 5 (15.2% [12.9–17.5], p = 0.002), with corresponding reductions in TAR. Conclusion: All three hybrid AID systems were associated with improvements in glycaemic outcomes in real‐world use, supporting the role of AID systems in the management of T1D. Medtronic 780G use was associated with higher TIR increase compared with the other systems; however, these findings are based on measurements from different continuous glucose monitors between AID groups and cannot be used to infer superiority in glycaemic attainment.
- 12 February 2026
- Published by Wiley in Diabetic Medicine
- Vol. 43 (5) , e70251
Open AccessReal‐world glycaemic outcomes observed with the use of Medtronic 780G , Tandem Control‐ IQ and Omnipod 5 automated insulin delivery systems
Background: No randomised controlled trials have directly compared commercially available hybrid automated insulin delivery (AID) systems, and real‐world comparative data remain limited. This study evaluated glycaemic outcomes across three hybrid AID systems in adults with type 1 diabetes (T1D). Methods: This was a retrospective, observational, single‐centre study and included adults with T1D who transitioned from multiple daily injections (MDI) or non‐automated insulin pump therapy to hybrid AID. Data were collected from routinely used clinical data‐sharing platforms and electronic health records. Outcomes compared across systems included time in range (TIR; 3.9–10.0 mmol/L), time below range (TBR; 13.9 mmol/L), glucose management indicator (GMI, %) and coefficient of variation (CV, %). Results: A total of 213 participants were included (Medtronic 780G n = 38; Tandem Control‐IQ n = 81; Omnipod 5 n = 94). After adjustment for baseline TIR, diabetes duration, insulin modality and AID use duration 780G users achieved a higher TIR increase (21.1% [95% CI 18.4–23.7]) compared to Control‐IQ (10.1% [3.2–17.3], p = 0.010) and Omnipod 5 (15.2% [12.9–17.5], p = 0.002), with corresponding reductions in TAR. Conclusion: All three hybrid AID systems were associated with improvements in glycaemic outcomes in real‐world use, supporting the role of AID systems in the management of T1D. Medtronic 780G use was associated with higher TIR increase compared with the other systems; however, these findings are based on measurements from different continuous glucose monitors between AID groups and cannot be used to infer superiority in glycaemic attainment.
- 1 May 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (5) , 402-406
Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)
The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.0 [58.0–74.5] years) were recruited. Overall percentage (%) mean and median absolute relative differences were 10.4% and 8.5% for matched laboratory pairs, respectively ( n = 720). Diabetes Technology Society error grid analysis showed 99.7%, 100%, and 99.9% of pairs within zones A and B for lab, glucometer, and EKF methods, respectively. This, the first Dexcom G7 accuracy study conducted in people on hemodialysis, demonstrates accuracy and safety when compared with lab reference readings. These data support the accessibility of continuous glucose monitoring (CGM) and hybrid closed-loop systems for people with diabetes on hemodialysis.
- 1 May 2025
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 27 (5) , 402-406
Accuracy of the Dexcom G7 Continuous Glucose Monitoring Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA-2 Study)
The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.0 [58.0–74.5] years) were recruited. Overall percentage (%) mean and median absolute relative differences were 10.4% and 8.5% for matched laboratory pairs, respectively ( n = 720). Diabetes Technology Society error grid analysis showed 99.7%, 100%, and 99.9% of pairs within zones A and B for lab, glucometer, and EKF methods, respectively. This, the first Dexcom G7 accuracy study conducted in people on hemodialysis, demonstrates accuracy and safety when compared with lab reference readings. These data support the accessibility of continuous glucose monitoring (CGM) and hybrid closed-loop systems for people with diabetes on hemodialysis.
- Open Access
- 12 July 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (7) , 498-502
Switching from Intermittently Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia
Differences in the effectiveness of real-time continuous glucose monitoring (rtCGM) and intermittently scanned continuous glucose monitoring (isCGM) in type 1 diabetes (T1D) are reported. The impact on percent time in range of switching from an isCGM with glucose threshold-based optional alerts only (FreeStyle Libre 2 [FSL2]) to an rtCGM (Dexcom G7) with an urgent low soon predictive alert was assessed, alongside other secondary outcomes including hemoglobin A1c (HbA1c) and other continuous glucose monitoring metrics. Adults with T1D using FSL2 were switched to Dexcom G7 for 12 weeks. HbA1c and continuous glucose data during FSL2 and Dexcom G7 use were compared. Data from 29 participants (aged 44.8 ± 16.5 years, 12 male and 17 female) were analyzed. After switching to rtCGM, participants spent less time in hypoglycemia below 3.9 mmol/L (70 mg/dL) (3.0% [1.0%, 5.0%] vs. 2.0% [1.0%, 3.0%], P = 0.006) and had higher percentage achievement of time below 3.9 mmol/L (70 mg/dL) of P = 0.005). Coefficient of variation was lower (39.3 ± 6.6% vs. 37.2 ± 5.6%, P = 0.008). In conclusion, adults with T1D who switched from isCGM to rtCGM may benefit from reduced exposure to hypoglycemia and glycemic variability.
- 12 July 2024
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 26 (7) , 498-502
Open AccessSwitching from Intermittently Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia
Differences in the effectiveness of real-time continuous glucose monitoring (rtCGM) and intermittently scanned continuous glucose monitoring (isCGM) in type 1 diabetes (T1D) are reported. The impact on percent time in range of switching from an isCGM with glucose threshold-based optional alerts only (FreeStyle Libre 2 [FSL2]) to an rtCGM (Dexcom G7) with an urgent low soon predictive alert was assessed, alongside other secondary outcomes including hemoglobin A1c (HbA1c) and other continuous glucose monitoring metrics. Adults with T1D using FSL2 were switched to Dexcom G7 for 12 weeks. HbA1c and continuous glucose data during FSL2 and Dexcom G7 use were compared. Data from 29 participants (aged 44.8 ± 16.5 years, 12 male and 17 female) were analyzed. After switching to rtCGM, participants spent less time in hypoglycemia below 3.9 mmol/L (70 mg/dL) (3.0% [1.0%, 5.0%] vs. 2.0% [1.0%, 3.0%], P = 0.006) and had higher percentage achievement of time below 3.9 mmol/L (70 mg/dL) of P = 0.005). Coefficient of variation was lower (39.3 ± 6.6% vs. 37.2 ± 5.6%, P = 0.008). In conclusion, adults with T1D who switched from isCGM to rtCGM may benefit from reduced exposure to hypoglycemia and glycemic variability.
- Open Access
- 5 March 2024
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 26 (S1) , 46-56
The role of real‐time continuous glucose monitoring in diabetes management and how it should link to integrated personalized diabetes management
Diabetes is a complex metabolic condition that demands tailored, individualized approaches for effective management. Real‐time continuous glucose monitoring (rtCGM) systems have improved in terms of design, usability and accuracy over the years and play a pivotal role in the delivery of integrated personalized diabetes management (iPDM). iPDM is a comprehensive multidisciplinary approach that combines individualized care strategies utilizing technologies and interventions and encourages the active involvement of the person with diabetes in the care provided. The use of stand‐alone rtCGM and its integration with other diabetes technologies, such as hybrid automated insulin delivery, have enabled improved glycaemic and quality of life outcomes for people with diabetes. As the uptake of rtCGM and associated technologies is increasing and becoming the standard of care for people with diabetes, it is important that efforts are focused on associated goals such as reducing health inequalities in terms of access, aligning structured education with rtCGM usage, choosing the right technology based on needs and preferences, and minimizing burden while aiming for optimal glucose outcomes. Utilizing rtCGM in other settings than outpatients and in diabetes cohorts beyond type 1 and type 2 diabetes needs further exploration. This review aims to provide an overview of the role of rtCGM and how best to link rtCGM to iPDM, highlighting its role in enhancing personalized treatment strategies.
- 5 March 2024
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 26 (S1) , 46-56
Open AccessThe role of real‐time continuous glucose monitoring in diabetes management and how it should link to integrated personalized diabetes management
Diabetes is a complex metabolic condition that demands tailored, individualized approaches for effective management. Real‐time continuous glucose monitoring (rtCGM) systems have improved in terms of design, usability and accuracy over the years and play a pivotal role in the delivery of integrated personalized diabetes management (iPDM). iPDM is a comprehensive multidisciplinary approach that combines individualized care strategies utilizing technologies and interventions and encourages the active involvement of the person with diabetes in the care provided. The use of stand‐alone rtCGM and its integration with other diabetes technologies, such as hybrid automated insulin delivery, have enabled improved glycaemic and quality of life outcomes for people with diabetes. As the uptake of rtCGM and associated technologies is increasing and becoming the standard of care for people with diabetes, it is important that efforts are focused on associated goals such as reducing health inequalities in terms of access, aligning structured education with rtCGM usage, choosing the right technology based on needs and preferences, and minimizing burden while aiming for optimal glucose outcomes. Utilizing rtCGM in other settings than outpatients and in diabetes cohorts beyond type 1 and type 2 diabetes needs further exploration. This review aims to provide an overview of the role of rtCGM and how best to link rtCGM to iPDM, highlighting its role in enhancing personalized treatment strategies.
- 28 June 2023
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (7) , 447-456
The Accuracy of Continuous Glucose Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA Study)
Objectives: Real-time and intermittently scanned continuous glucose monitoring are increasingly used for glucose monitoring in people with diabetes requiring renal replacement therapy, with limited data reporting their accuracy in this cohort. We evaluated the accuracy of Dexcom G6 and Abbott Freestyle Libre 1 glucose monitoring systems in people with diabetes undergoing hemodialysis. Methods: Participants on hemodialysis with diabetes (on insulin or sulfonylureas) were recruited. Paired sensor glucose from Dexcom G6 and Freestyle Libre 1 were recorded with plasma glucose analyzed using the Yellow Springs Instrument (YSI) method at frequent intervals during hemodialysis. Analysis of accuracy metrics included mean absolute relative difference (MARD), Clarke error grid (CEG) analysis and proportion of CGM values within 15% and 20% or 15 and 20 mg/dL of YSI reference values for blood glucose >100 or ≤100 mg/dL, respectively (% 15/15, % 20/20). Results: Forty adults (median age 64.7 [60.2–74.4] years) were recruited. Overall MARD for Dexcom G6 was 22.7% (2656 matched glucose pairs), and 11.3% for Libre 1 ( n = 2785). The proportions of readings meeting %15/15 and %20/20 were 29.1% and 45.4% for Dexcom G6, respectively, and 73.5% and 85.6% for Libre 1. CEG analysis showed 98.9% of all values in zones A and B for Dexcom G6 and 99.8% for Libre 1. Conclusions: Our results indicate Freestyle Libre 1 is a reliable tool for glucose monitoring in adults on hemodialysis. Further studies are required to evaluate Dexcom G6 accuracy in people on hemodialysis.
- 28 June 2023
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (7) , 447-456
The Accuracy of Continuous Glucose Sensors in People with Diabetes Undergoing Hemodialysis (ALPHA Study)
Objectives: Real-time and intermittently scanned continuous glucose monitoring are increasingly used for glucose monitoring in people with diabetes requiring renal replacement therapy, with limited data reporting their accuracy in this cohort. We evaluated the accuracy of Dexcom G6 and Abbott Freestyle Libre 1 glucose monitoring systems in people with diabetes undergoing hemodialysis. Methods: Participants on hemodialysis with diabetes (on insulin or sulfonylureas) were recruited. Paired sensor glucose from Dexcom G6 and Freestyle Libre 1 were recorded with plasma glucose analyzed using the Yellow Springs Instrument (YSI) method at frequent intervals during hemodialysis. Analysis of accuracy metrics included mean absolute relative difference (MARD), Clarke error grid (CEG) analysis and proportion of CGM values within 15% and 20% or 15 and 20 mg/dL of YSI reference values for blood glucose >100 or ≤100 mg/dL, respectively (% 15/15, % 20/20). Results: Forty adults (median age 64.7 [60.2–74.4] years) were recruited. Overall MARD for Dexcom G6 was 22.7% (2656 matched glucose pairs), and 11.3% for Libre 1 ( n = 2785). The proportions of readings meeting %15/15 and %20/20 were 29.1% and 45.4% for Dexcom G6, respectively, and 73.5% and 85.6% for Libre 1. CEG analysis showed 98.9% of all values in zones A and B for Dexcom G6 and 99.8% for Libre 1. Conclusions: Our results indicate Freestyle Libre 1 is a reliable tool for glucose monitoring in adults on hemodialysis. Further studies are required to evaluate Dexcom G6 accuracy in people on hemodialysis.
- 29 May 2023
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (6) , 414-425
Safety and Efficacy of an Adaptive Bolus Calculator for Type 1 Diabetes: A Randomized Controlled Crossover Study
Background: The Advanced Bolus Calculator for Type 1 Diabetes (ABC4D) is a decision support system using the artificial intelligence technique of case-based reasoning to adapt and personalize insulin bolus doses. The integrated system comprises a smartphone application and clinical web portal. We aimed to assess the safety and efficacy of the ABC4D (intervention) compared with a nonadaptive bolus calculator (control). Methods: This was a prospective randomized controlled crossover study. Following a 2-week run-in period, participants were randomized to ABC4D or control for 12 weeks. After a 6-week washout period, participants crossed over for 12 weeks. The primary outcome was difference in % time in range (%TIR) (3.9–10.0 mmol/L [70–180 mg/dL]) change during the daytime (07:00–22:00) between groups. Results: Thirty-seven adults with type 1 diabetes on multiple daily injections of insulin were randomized, median (interquartile range [IQR]) age 44.7 (28.2–55.2) years, diabetes duration 15.0 (9.5–29.0) years, and glycated hemoglobin 61.0 (58.0–67.0) mmol/mol (7.7 [7.5–8.3]%). Data from 33 participants were analyzed. There was no significant difference in daytime %TIR change with ABC4D compared with control (median [IQR] +0.1 [−2.6 to +4.0]% vs. +1.9 [−3.8 to +10.1]%; P = 0.53). Participants accepted fewer meal dose recommendations in the intervention compared with control (78.7 [55.8–97.6]% vs. 93.5 [73.8–100]%; P = 0.009), with a greater reduction in insulin dosage from that recommended. Conclusion: The ABC4D is safe for adapting insulin bolus doses and provided the same level of glycemic control as the nonadaptive bolus calculator. Results suggest that participants did not follow the ABC4D recommendations as frequently as control, impacting its effectiveness. Clinical Trials Registration: clinicaltrials.gov NCT03963219 (Phase 5).
- 29 May 2023
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 25 (6) , 414-425
Safety and Efficacy of an Adaptive Bolus Calculator for Type 1 Diabetes: A Randomized Controlled Crossover Study
Background: The Advanced Bolus Calculator for Type 1 Diabetes (ABC4D) is a decision support system using the artificial intelligence technique of case-based reasoning to adapt and personalize insulin bolus doses. The integrated system comprises a smartphone application and clinical web portal. We aimed to assess the safety and efficacy of the ABC4D (intervention) compared with a nonadaptive bolus calculator (control). Methods: This was a prospective randomized controlled crossover study. Following a 2-week run-in period, participants were randomized to ABC4D or control for 12 weeks. After a 6-week washout period, participants crossed over for 12 weeks. The primary outcome was difference in % time in range (%TIR) (3.9–10.0 mmol/L [70–180 mg/dL]) change during the daytime (07:00–22:00) between groups. Results: Thirty-seven adults with type 1 diabetes on multiple daily injections of insulin were randomized, median (interquartile range [IQR]) age 44.7 (28.2–55.2) years, diabetes duration 15.0 (9.5–29.0) years, and glycated hemoglobin 61.0 (58.0–67.0) mmol/mol (7.7 [7.5–8.3]%). Data from 33 participants were analyzed. There was no significant difference in daytime %TIR change with ABC4D compared with control (median [IQR] +0.1 [−2.6 to +4.0]% vs. +1.9 [−3.8 to +10.1]%; P = 0.53). Participants accepted fewer meal dose recommendations in the intervention compared with control (78.7 [55.8–97.6]% vs. 93.5 [73.8–100]%; P = 0.009), with a greater reduction in insulin dosage from that recommended. Conclusion: The ABC4D is safe for adapting insulin bolus doses and provided the same level of glycemic control as the nonadaptive bolus calculator. Results suggest that participants did not follow the ABC4D recommendations as frequently as control, impacting its effectiveness. Clinical Trials Registration: clinicaltrials.gov NCT03963219 (Phase 5).
- Open Access
- 18 April 2023
- Published by Wiley in Diabetic Medicine
- Vol. 40 (7) , e15100
Real‐time continuous glucose monitoring immediately after severe hypoglycaemia requiring emergency medical services: A randomised controlled trial
Aims: Severe hypoglycaemia requiring emergency medical services remains prevalent despite advances in all aspects of diabetes self‐management. Real‐time continuous glucose monitoring (RTCGM) technologies can reduce the risk of severe hypoglycaemia for adults with type 1 diabetes, but the impact of these devices has not been assessed in the acute phase after an episode of severe hypoglycaemia.Methods: We recruited and randomised 35 adults with type 1 diabetes in the acute period after an episode of severe hypoglycaemia requiring emergency medical services and randomised participants to RTCGM with alerts and alarms, or usual care with self‐monitored blood glucose for 12 weeks with intermittent blinded CGM. The primary outcome was the difference between groups in percentage time spent in hypoglycaemia (≤3.0 mmol/L, 55 mg/dL).Results: Thirty participants completed the study (median (IQR) age, duration of diabetes, and BMI was 43 (36–56) years, 26 (19–37) years, and 24.9 (21.9–29.0) kg/m2, respectively). Sufficient CGM data was available for 15 participants in RT‐CGM group and 8 in SMBG group for the primary outcome analysis. The RTCGM group had a significantly larger reduction in exposure to glucose below 3.0 mmol/L (RTCGM −0.16 [−1.23 to 0.01] vs. SMBG 1.58 [0.41 to 3.48], p = 0.03) and episodes of nocturnal hypoglycaemia (RT‐CGM −0.03 [−0.15 to 0.02] vs. SMBG 0.05 [−0.03 to 0.40], p = 0.02). Episodes of severe hypoglycaemia were significantly lower in the RTCGM group (RTCGM 0.0 vs. SMBG 4.0, p 0.04).Conclusions: RTCGM implemented acutely after an episode of severe hypoglycaemia is feasible and clinically effective with important implications for hypoglycaemia management pathways and self‐monitoring cost effectiveness.
- 18 April 2023
- Published by Wiley in Diabetic Medicine
- Vol. 40 (7) , e15100
Open AccessReal‐time continuous glucose monitoring immediately after severe hypoglycaemia requiring emergency medical services: A randomised controlled trial
Aims: Severe hypoglycaemia requiring emergency medical services remains prevalent despite advances in all aspects of diabetes self‐management. Real‐time continuous glucose monitoring (RTCGM) technologies can reduce the risk of severe hypoglycaemia for adults with type 1 diabetes, but the impact of these devices has not been assessed in the acute phase after an episode of severe hypoglycaemia.Methods: We recruited and randomised 35 adults with type 1 diabetes in the acute period after an episode of severe hypoglycaemia requiring emergency medical services and randomised participants to RTCGM with alerts and alarms, or usual care with self‐monitored blood glucose for 12 weeks with intermittent blinded CGM. The primary outcome was the difference between groups in percentage time spent in hypoglycaemia (≤3.0 mmol/L, 55 mg/dL).Results: Thirty participants completed the study (median (IQR) age, duration of diabetes, and BMI was 43 (36–56) years, 26 (19–37) years, and 24.9 (21.9–29.0) kg/m2, respectively). Sufficient CGM data was available for 15 participants in RT‐CGM group and 8 in SMBG group for the primary outcome analysis. The RTCGM group had a significantly larger reduction in exposure to glucose below 3.0 mmol/L (RTCGM −0.16 [−1.23 to 0.01] vs. SMBG 1.58 [0.41 to 3.48], p = 0.03) and episodes of nocturnal hypoglycaemia (RT‐CGM −0.03 [−0.15 to 0.02] vs. SMBG 0.05 [−0.03 to 0.40], p = 0.02). Episodes of severe hypoglycaemia were significantly lower in the RTCGM group (RTCGM 0.0 vs. SMBG 4.0, p 0.04).Conclusions: RTCGM implemented acutely after an episode of severe hypoglycaemia is feasible and clinically effective with important implications for hypoglycaemia management pathways and self‐monitoring cost effectiveness.
- 31 May 2022
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 24 (6) , 403-408
Identifying Continuous Glucose Monitoring Data Using Machine Learning
Background and Aims: The recent increase in wearable devices for diabetes care, and in particular the use of continuous glucose monitoring (CGM), generates large data sets and associated cybersecurity challenges. In this study, we demonstrate that it is possible to identify CGM data at an individual level by using standard machine learning techniques. Methods: The publicly available REPLACE-BG data set (NCT02258373) containing 226 adult participants with type 1 diabetes (T1D) wearing CGM over 6 months was used. A support vector machine (SVM) binary classifier aiming to determine if a CGM data stream belongs to an individual participant was trained and tested for each of the subjects in the data set. To generate the feature vector used for classification, 12 standard glycemic metrics were selected and evaluated at different time periods of the day (24 h, day, night, breakfast, lunch, and dinner). Different window lengths of CGM data (3, 7, 15, and 30 days) were chosen to evaluate their impact on the classification performance. A recursive feature selection method was employed to select the minimum subset of features that did not significantly degrade performance. Results: A total of 40 features were generated as a result of evaluating the glycemic metrics over the selected time periods (24 h, day, night, breakfast, lunch, and dinner). A window length of 15 days was found to perform the best in terms of accuracy (86.8% ± 12.8%) and F1 score (0.86 ± 0.16). The corresponding sensitivity and specificity were 85.7% ± 19.5% and 87.9% ± 17.5%, respectively. Through recursive feature selection, a subset of 9 features was shown to perform similarly to the 40 features. Conclusion: It is possible to determine with a relatively high accuracy if a CGM data stream belongs to an individual. The proposed approach can be used as a digital CGM “fingerprint” or for detecting glycemic changes within an individual, for example during intercurrent illness.
- 31 May 2022
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 24 (6) , 403-408
Identifying Continuous Glucose Monitoring Data Using Machine Learning
Background and Aims: The recent increase in wearable devices for diabetes care, and in particular the use of continuous glucose monitoring (CGM), generates large data sets and associated cybersecurity challenges. In this study, we demonstrate that it is possible to identify CGM data at an individual level by using standard machine learning techniques. Methods: The publicly available REPLACE-BG data set (NCT02258373) containing 226 adult participants with type 1 diabetes (T1D) wearing CGM over 6 months was used. A support vector machine (SVM) binary classifier aiming to determine if a CGM data stream belongs to an individual participant was trained and tested for each of the subjects in the data set. To generate the feature vector used for classification, 12 standard glycemic metrics were selected and evaluated at different time periods of the day (24 h, day, night, breakfast, lunch, and dinner). Different window lengths of CGM data (3, 7, 15, and 30 days) were chosen to evaluate their impact on the classification performance. A recursive feature selection method was employed to select the minimum subset of features that did not significantly degrade performance. Results: A total of 40 features were generated as a result of evaluating the glycemic metrics over the selected time periods (24 h, day, night, breakfast, lunch, and dinner). A window length of 15 days was found to perform the best in terms of accuracy (86.8% ± 12.8%) and F1 score (0.86 ± 0.16). The corresponding sensitivity and specificity were 85.7% ± 19.5% and 87.9% ± 17.5%, respectively. Through recursive feature selection, a subset of 9 features was shown to perform similarly to the 40 features. Conclusion: It is possible to determine with a relatively high accuracy if a CGM data stream belongs to an individual. The proposed approach can be used as a digital CGM “fingerprint” or for detecting glycemic changes within an individual, for example during intercurrent illness.
- 20 April 2021
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 23 (5) , 392-396
Self-Monitoring of Blood Glucose Requirements with the Use of Intermittently Scanned Continuous Glucose Monitoring: A Follow-Up Analysis Using Real-Life Data
Hypoglycemia-prone individuals with type 1 diabetes (T1D) who use intermittently scanned continuous glucose monitoring (isCGM) systems spend about 5 h/day in states where self-monitoring of blood glucose (SMBG) is indicated. Here we present estimates of the need for SMBG testing by retrospectively analyzing isCGM data from a cohort of real-world isCGM users. Data from 67 individuals were included in the analysis. Mean (SD) 3.18 (1.63) h/day was spent in an SMBG-indicated state and the number of transitions to an SMBG-indicated state was 3.86 (1.46)/day. Frequency of clinically important hypoglycemia [<3.0 mmol/L (<54 mmol/dL)] was median (IQR) 1.5 (0.6–3.4) episodes/week, of which only 50% were associated with a scan during the episode, and the average duration was 75.2 (63.9–91.8) min/episode. The need for continued SMBG testing remains important for all isCGM users and may affect the overall cost-effectiveness of isCGM. Impaired awareness of hypoglycemia and incidence of asymptomatic hypoglycemia may be underreported among real-life isCGM users in clinical practice.
- 20 April 2021
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 23 (5) , 392-396
Self-Monitoring of Blood Glucose Requirements with the Use of Intermittently Scanned Continuous Glucose Monitoring: A Follow-Up Analysis Using Real-Life Data
Hypoglycemia-prone individuals with type 1 diabetes (T1D) who use intermittently scanned continuous glucose monitoring (isCGM) systems spend about 5 h/day in states where self-monitoring of blood glucose (SMBG) is indicated. Here we present estimates of the need for SMBG testing by retrospectively analyzing isCGM data from a cohort of real-world isCGM users. Data from 67 individuals were included in the analysis. Mean (SD) 3.18 (1.63) h/day was spent in an SMBG-indicated state and the number of transitions to an SMBG-indicated state was 3.86 (1.46)/day. Frequency of clinically important hypoglycemia [<3.0 mmol/L (<54 mmol/dL)] was median (IQR) 1.5 (0.6–3.4) episodes/week, of which only 50% were associated with a scan during the episode, and the average duration was 75.2 (63.9–91.8) min/episode. The need for continued SMBG testing remains important for all isCGM users and may affect the overall cost-effectiveness of isCGM. Impaired awareness of hypoglycemia and incidence of asymptomatic hypoglycemia may be underreported among real-life isCGM users in clinical practice.