RRRajul V. Randive

Rajul V. Randive

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rajul V. Randive has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards a Healthy Car: UVC LEDs in an Automobile’s HVAC Demonstrates Effective Disinfection of Cabin Air

    by Richard M. Mariita, James H. Davis, Michelle M. Lottridge, Rajul V. Randive, Hauke Witting, Johannes Yu

    Vehicle Heating, ventilation, and air conditioning (HVAC) systems can accumulate and recirculate highly infectious respiratory diseases via aerosols. Integrating Ultraviolet Subtype C (UVC) light-emitting diodes (LEDs) to complement automobile HVAC systems can protect occupants from developing allergies, experiencing inflammatory problems, or acquiring respiratory infectious diseases by inactivating pathogenic organisms. UVC can add little to no static pressure with minimal space, unlike mercury lamps which are larger and heavier. Additionally, UVC LEDs are effective at low voltage and have no mercury or glass. While previous experiments have shown UVC LED technology can reduce bacteriophage Phi6 concentrations by 1 log in 5 min (selected as the average time to clean the cabin air), those studies had not positioned LED within the HVAC itself or studied the susceptibility of the surrogate at the specific wavelength. This study aimed to assess the disinfection performance of UVC LEDs in automotive HVAC systems and determine the dose–response curve for bacteriophage Phi6, a SARS-CoV-2 surrogate. To achieve this, UVC LEDs were installed in a car HVAC system. To determine inactivation efficacy, a model chamber of 3.5 m3, replicating the typical volume of a car, containing the modified automobile HVAC system was filled with bacteriophage Phi6, and the HVAC was turned on with and without the UVC LEDs being turned on. The results revealed that HVAC complemented with UVC reduced bacteriophage Phi6 levels significantly more than the HVAC alone and reduced the viral concentration in the cabin by more than 90% viral reduction in less than 5 min. The performance after 5 min is expected to be significantly better against SARS-CoV-2 because of its higher sensitivity to UVC, especially at lower wavelengths (below 270 nm). HVAC alone could not achieve a 90% viral reduction of bacteriophage Phi6 in 15 min. Applying UVC LEDs inside an HVAC system is an effective means of quickly reducing the number of aerosolized viral particles in the chamber, by inactivating microorganisms leading to improved cabin air quality.


  • Open Access

    Towards a Healthy Car: UVC LEDs Inside Automobile HVAC Chamber Offers Effective Complementary Disinfection to Ensure Clean Cabin Air

    by Richard Mariita, James H. Davis, Michelle M. Lottridge, Rajul V. Randive, Hauke Witting, Johannes Yu

    Vehicle HVAC systems can accumulate and recirculate highly infectious respiratory diseases via aerosols. Integrating UVC to complement automobile HVAC systems can protect occupants from developing allergies, experiencing inflammatory problems, or acquiring respiratory infectious diseases by inactivating pathogenic organisms. UVC can add little to no static pressure with minimal space, unlike mercury lamps which are larger and heavier. Additionally, UVC LEDs are effective at low voltage and have no mercury or glass. While previous experiments have shown UVC LED technology can reduce bacteriophage Phi6 concentrations by 1 log in 5 minutes (selected as the average time to clean the cabin air), those studies had not positioned LED within the HVAC itself or studied the susceptibility of the surrogate at the specific wavelength. This study aimed to assess the disinfection performance of UVC LEDs in automotive HVAC systems and determine the dose-response curve for bacteriophage Phi6, a SARS-CoV-2 surrogate. To achieve this, UVC LEDs were installed in a car HVAC system. To determine inactivation efficacy, a model chamber of 3.5 m3, replicating the typical volume of a car, containing the modified automobile HVAC system was filled with bacteriophage Phi6, and the HVAC was turned on with and without the UVC LEDs being turned on. The results revealed that HVAC complemented with UVC reduced bacteriophage Phi6 levels significantly more than the HVAC alone and reduced the viral concentration in the cabin by more than 1 LRV (90% viral reduction) in less than 5 minutes. The performance after 5 minutes is expected to be significantly better against SARS-CoV-2 because of its higher sensitivity to UVC, especially at lower wavelengths (below 270 nm). HVAC alone could not achieve a 90% viral reduction of bacteriophage Phi6 in 15 minutes. Applying UVC LEDs inside an HVAC system is an effective means of quickly reducing the number of aerosolized viral particles in the chamber, by inactivating microorganisms leading to improved cabin air quality.


  • Open Access

    Illuminating Human Norovirus: A Perspective on Disinfection of Water and Surfaces Using UVC, Norovirus Model Organisms, and Radiation Safety Considerations

    by Richard M. Mariita, James H. Davis, Rajul V. Randive

    Human noroviruses (HuNoVs) are a major cause of gastroenteritis and are associated with high morbidity because of their ability to survive in the environment and small inoculum size required for infection. Norovirus is transmitted through water, food, high touch-surfaces, and human-to-human contact. Ultraviolet Subtype C (UVC) light-emitting diodes (LEDs) can disrupt the norovirus transmission chain for water, food, and surfaces. Here, we illuminate considerations to be adhered to when picking norovirus surrogates for disinfection studies and shine light on effective use of UVC for norovirus infection control in water and air and validation for such systems and explore the blind spot of radiation safety considerations when using UVC disinfection strategies. This perspective also discusses the promise of UVC for norovirus mitigation to save and ease life.


  • Open Access

    Shining light on multi‐drug resistant Candida auris: Ultraviolet‐C disinfection, wavelength sensitivity, and prevention of biofilm formation of an emerging yeast pathogen

    by Richard M. Mariita, James H. Davis, Michelle M. Lottridge, Rajul V. Randive

    Candida auris is an emerging fungal superbug of worldwide interest. It is associated with high mortality rates and exhibits increased resistance to antifungals. Ultraviolet subtype C (UVC) light can be used to disinfect surfaces to mitigate its spread. The objectives of this study were (1) To investigate UVC disinfection performances and wavelength sensitivity of C. auris. (2) To evaluate the UVC dose required for the prevention of biofilm formation on stainless‐steel, plastic (polystyrene), and poly‐cotton fabric surfaces. C. auris was grown following standard procedures. The study utilized six different UVC LED arrays with wavelengths between 252 and 280 nm. Arrays were set at similar intensities, to obtain doses of 5–40 mJ cm−2 and similar irradiation time. Disinfection performance for each array was determined using log reduction value (LRV) and percentage reduction by comparing the controls against the irradiated treatments. Evaluation of the ability of 267 nm UVC LEDs to prevent C. auris biofilm formation was investigated using stainless‐steel, plastic coupons, and poly‐cotton fabric. Peak sensitivity to UVC disinfection was between 267 and 270 nm. With 20 mJ cm−2, the study obtained ≥LRV3. On stainless‐steel coupons, 30 mJ cm−2 was sufficient to prevent biofilm formation, while on plastic, this required 10 mJ cm−2. A dose of 60 mJ cm−2 reduced biofilms on poly‐cotton fabric significantly (R2 = 0.9750, p = 0.0002). The study may allow for the design and implementation of disinfection systems.


  • Open Access

    Evaluation of the virucidal efficacy of Klaran UVC LEDs against surface-dried norovirus

    by Richard M. Mariita, Amy C. Wilson Miller, Rajul V. Randive

    Human norovirus (HuNoV) is a highly contagious pathogenic virus that is transmitted through contaminated food, water, high-touch surfaces and aerosols. Globally, there are an estimated 685 million infections annually due to norovirus, including 200 million affecting children under the age of 5. HuNoV causes approximately 50, 000 child deaths per year and costs an estimated USD $60 billion annually in healthcare. This study sought to determine the inactivation profile of ultraviolet subtype C (UVC) against norovirus using a UVC light-emitting diode (LED) array, KL265-50V-SM-WD. The array emitted radiation at 269 nm peak wavelength and a measured fluence of 1.25 mW cm−2 at a 7 cm source–surface distance. Since the HuNoV is not cultivable, the study utilized feline calicivirus (FCV) ATCC VR-782, a recommended surrogate as challenge organism. The test followed modified ASTM E2197. Assessment of virus inactivation was performed using a plaque assay method. With irradiance at a UVC dose of 22.5 mJ cm−2, the study obtained 99.9 % virus reduction (3 log reduction). The results demonstrate that the UVC LED array can provide effective inactivation of HuNoV.


  • Open Access

    Disinfection of methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus faecium and Acinetobacter baumannii using Klaran WD array system

    by Richard M. Mariita, Rajul V. Randive

    Hospital-associated infections (HAIs) are a major burden in healthcare systems. In this study, UVC LEDs emitting radiation from 260 to 270 nm were evaluated for effectiveness in reducing methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus faecium and Acinetobacter baumannii . The array has four WD LEDs, each with 70 mW placed at 7 cm from test organisms. With 11.76 mJ cm−2, the study obtained 99.99% reduction (log10 reduction factor of 4) against MRSA and VRE. For A. baumannii , 9 mJ cm−2 obtained 99.999% reduction (log10 reduction factor of 5). These results present scientific evidence on how effective UVC LEDs can be used in the fight against HAIs.


  • Open Access

    Disinfection of SARS-CoV-2 using UVC reveals wavelength sensitivity contributes towards rapid virucidal activity

    by Richard M. Mariita, Amy C. Wilson Miller, Rajul V. Randive, Lindsay G. A. McKay, Nadia Storm, Anthony Griffiths

    SARS-CoV-2 can be disinfected using ultraviolet-C (UVC) light. For effective inactivation strategies, design and implementation, knowledge of UVC wavelength sensitivity, and disinfection rate of the relevant pathogen are required. This study aimed to determine the inactivation profile of SARS-CoV-2 using UVC irradiation with different wavelengths. Specifically, the study determined dosage, inactivation levels, and wavelength sensitivity of SARS-CoV-2. Assessment of SARS-CoV-2 (isolate USA/WA1-2020) inactivation at peak wavelengths of 259, 268, 270, 275 and 280 nm was performed using a plaque assay method. A UVC dose of 3.1 mJ/cm 2 using 259 and 268 nm arrays yielded log reduction values (LRV) of 2.32 and 2.44, respectively. With a dose of 5 mJ/cm 2 , arrays of peak wavelengths at 259 and 268 nm obtained similar inactivation levels (LRV 2.97 and 2.80 respectively). The arrays of longer wavelength (270, 275 and 280 nm), demonstrated lower performances (≤LRV 2.0) when applying an irradiation dose of 5 mJ/cm 2 . Additional study with the 268 nm array revealed that a dose of 6.25 mJ/cm 2 is enough to obtain a LRV of 3. These results suggest that 259 and 268 nm are the most efficient wavelengths for SARS-CoV-2 inactivation compared to longer UVC wavelengths, allowing the calculation of disinfection systems efficacy.


  • Open Access

    Disinfection performance of a drinking water bottle system with a UVC LED cap against waterborne pathogens and heterotrophic contaminants

    by Richard M. Mariita, Sébastien A. Blumenstein, Christian M. Beckert, Thomas Gombas, Rajul V. Randive

    Background: The purgaty One systems (cap+bottle) are portable stainless-steel water bottles with ultraviolet subtype C (UVC) disinfection capability. This study examines the bottle design, verifies disinfection performance against Escherichia coli , Pseudomonas aeruginosa , Vibrio cholerae and heterotrophic contaminants and addresses the public health relevance of heterotrophic bacteria. Methods: Bottles were inoculated with bacterial strains and disinfection efficacy examined using colony forming unit (CFU) assay. The heterotrophic plate count (HPC) method was used to determine the disinfection performance against environmental contaminants at day 0 and after 3 days of water stagnation. All UVC irradiation experiments were performed under stagnant conditions to confirm that the preset application cycle of 55 seconds offers the desired disinfection performance under worst case condition. To determine effectiveness of purgaty One systems (cap+bottle) in disinfection, inactivation efficacy or log reduction value (LRV) was determined using bacteria concentration between UVC ON condition and controls (UVC OFF). The study utilized the 16S rRNA gene for isolate characterization by identifying HPC bacteria to confirm if they belong to groups that are of public health concern. Results: Purgaty One systems fitted with Klaran UVC LEDs achieved 99.99% inactivation (LRV4) efficacy against E. coli and 99.9% inactivation (LRV3) against P. aeruginosa , V. cholerae and heterotrophic contaminants. Based on the 16S rRNA gene analyses, the study determined that the identified HPC isolates enriched by UVC irradiation are of rare public health concern. Conclusion: The bottles satisfactorily inactivated the target pathogenic bacteria and HPC contaminants even after 3 days of water stagnation.

  • Open Access

    Evaluation of the virucidal efficacy of Klaran UVC LEDs against surface dried norovirus

    by Richard M. Mariita, Amy C. Wilson Miller, Rajul V. Randive

    Human norovirus (HuNoV) is a highly contagious pathogenic virus that is transmitted through contaminated food, water, high-touch surfaces and aerosols. Globally, there are an estimated 685 million infections annually due to norovirus, among them 200 million children under the age of 5, causing approximately 50,000 child deaths per year and costing an estimated $60 billion annually in healthcare. In the USA, HuNoV is responsible for 19-21 million illnesses, with an average of 570-800 deaths per year. HuNoV is especially pernicious because it requires less than 100 viral particles to cause an infection, and there are few effective disinfectants. It is believed that Ultraviolet Subtype C (UVC) irradiation might prove to be an effective disinfectant. This study seeks to determine the inactivation profile of UVC against norovirus using a Klaran UVC Light-emitting diode (LED) array product number KL265-50V-SM-WD, emitting radiation at 269 nm peak wavelength and a measured fluence of 1.25 mW/cm 2 at a 7 cm source-surface distance. Since the HuNoV cannot currently be propagated in cell cultures, the study utilized feline calicivirus (FCV), a recommended surrogate as challenge organism. The test followed Modified ASTM E2197. Assessment of virus inactivation was performed using plaque assay method, with Crystal Violet as a staining agent to enhance plaque visualization. Within 18 seconds of exposure time at a UVC irradiance of 1.25mW/cm 2 and a dose of 22.5 mJ/cm 2 , the study obtained 99.9 % virus reduction (3 log reduction value). These results demonstrate that Klaran UVC-LED array (KL265-50V-SM-WD) can provide effective inactivation of HuNoV.


  • Open Access

    Disinfection of Methicillin-Resistant Staphylococcus aureus , Vancomycin-resistant Enterococcus faecium and Acinetobacter baumannii using Klaran WD array system

    by Richard M. Mariita, Rajul V. Randive

    Healthcare-associated infections (HAIs) are a major burden in healthcare systems. In this study, UVC LEDs emitting radiation from 260-270 nm were evaluated for effectiveness in reducing methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE), and Acinetobacter baumannii . The array has four WD LEDs, each with 70mW placed at 7cm from test organism. With 11.76 mJ/cm 2 , the study obtained 99.99% reduction (log10 reduction factor of 4) against MRSA and VRE. For A. baumannii , 9 mJ/cm 2 obtained 99.999% reduction (log10 reduction factor of 5). These results present scientific evidence on how effective UVC LEDs can be used in the fight against HAIs.