Zheng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zheng Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Timothy G. Constandinou
Imperial College London
12 shared publications - Oscar W. Savolainen
Imperial College London
5 shared publications - Peilong Feng
Department of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London, U.K.
3 shared publications Alexandru Oprea
Department of Electrical and Electronic Engineering, Imperial College London, South Kensington Campus, London, U.K.
2 shared publications- Adrien Rapeaux
Imperial College London Faculty of Engineering, Imperial College London, London, SW7 2AZ, United Kingdom of Great Britain and Northern Ireland
1 shared publication Bryan Hsieh
Imperial College London
1 shared publication
Latest Publications
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 725-740
Calibration-Free and Hardware-Efficient Neural Spike Detection for Brain Machine Interfaces
Recent translational efforts in brain-machine interfaces (BMI) are demonstrating the potential to help people with neurological disorders. The current trend in BMI technology is to increase the number of recording channels to the thousands, resulting in the generation of vast amounts of raw data. This in turn places high bandwidth requirements for data transmission, which increases power consumption and thermal dissipation of implanted systems. On-implant compression and/or feature extraction are therefore becoming essential to limiting this increase in bandwidth, but add further power constraints – the power required for data reduction must remain less than the power saved through bandwidth reduction. Spike detection is a common feature extraction technique used for intracortical BMIs. In this paper, we develop a novel firing-rate-based spike detection algorithm that requires no external training and is hardware efficient and therefore ideally suited for real-time applications. Key performance and implementation metrics such as detection accuracy, adaptability in chronic deployment, power consumption, area utilization, and channel scalability are benchmarked against existing methods using various datasets. The algorithm is first validated using a reconfigurable hardware (FPGA) platform and then ported to a digital ASIC implementation in both 65 nm and 0.18MU m CMOS technologies. The 128-channel ASIC design implemented in a 65 nm CMOS technology occupies 0.096 mm2 silicon area and consumes 4.86MU W from a 1.2 V power supply. The adaptive algorithm achieves a 96% spike detection accuracy on a commonly used synthetic dataset, without the need for any prior training.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (4) , 725-740
Calibration-Free and Hardware-Efficient Neural Spike Detection for Brain Machine Interfaces
Recent translational efforts in brain-machine interfaces (BMI) are demonstrating the potential to help people with neurological disorders. The current trend in BMI technology is to increase the number of recording channels to the thousands, resulting in the generation of vast amounts of raw data. This in turn places high bandwidth requirements for data transmission, which increases power consumption and thermal dissipation of implanted systems. On-implant compression and/or feature extraction are therefore becoming essential to limiting this increase in bandwidth, but add further power constraints – the power required for data reduction must remain less than the power saved through bandwidth reduction. Spike detection is a common feature extraction technique used for intracortical BMIs. In this paper, we develop a novel firing-rate-based spike detection algorithm that requires no external training and is hardware efficient and therefore ideally suited for real-time applications. Key performance and implementation metrics such as detection accuracy, adaptability in chronic deployment, power consumption, area utilization, and channel scalability are benchmarked against existing methods using various datasets. The algorithm is first validated using a reconfigurable hardware (FPGA) platform and then ported to a digital ASIC implementation in both 65 nm and 0.18MU m CMOS technologies. The 128-channel ASIC design implemented in a 65 nm CMOS technology occupies 0.096 mm2 silicon area and consumes 4.86MU W from a 1.2 V power supply. The adaptive algorithm achieves a 96% spike detection accuracy on a commonly used synthetic dataset, without the need for any prior training.
- Open Access
- 5 May 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (3) , 036003
Firing-rate-modulated spike detection and neural decoding co-design
Objective. Translational efforts on spike-signal-based implantable brain-machine interfaces (BMIs) are increasingly aiming to minimise bandwidth while maintaining decoding performance. Developing these BMIs requires advances in neuroscience and electronic technology, as well as using low-complexity spike detection algorithms and high-performance machine learning models. While some state-of-the-art BMI systems jointly design spike detection algorithms and machine learning models, it remains unclear how the detection performance affects decoding. Approach. We propose the co-design of the neural decoder with an ultra-low complexity spike detection algorithm. The detection algorithm is designed to attain a target firing rate, which the decoder uses to modulate the input features preserving statistical invariance in long term (over several months). Main results. We demonstrate a multiplication-free fixed-point spike detection algorithm with an average detection accuracy of 97% across different noise levels on a synthetic dataset and the lowest hardware complexity among studies we have seen. By co-designing the system to incorporate statistically invariant features, we observe significantly improved long-term stability, with decoding accuracy degrading by less than 10% after 80 days of operation. Our analysis also reveals a nonlinear relationship between spike detection and decoding performance. Increasing the detection sensitivity improves decoding accuracy and long-term stability, which means the activity of more neurons is beneficial despite the detection of more noise. Reducing the spike detection sensitivity still provides acceptable decoding accuracy whilst reducing the bandwidth by at least 30%. Significance. Our findings regarding the relationship between spike detection and decoding performance can provide guidance on setting the threshold for spike detection rather than relying on training or trial-and-error. The trade-off between data bandwidth and decoding performance can be effectively managed using appropriate spike detection settings. We demonstrate improved decoding performance by maintaining statistical invariance of input features. We believe this approach can motivate further research focused on improving decoding performance through the manipulation of data itself (based on a hypothesis) rather than using more complex decoding models.
- 5 May 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (3) , 036003
Open AccessFiring-rate-modulated spike detection and neural decoding co-design
Objective. Translational efforts on spike-signal-based implantable brain-machine interfaces (BMIs) are increasingly aiming to minimise bandwidth while maintaining decoding performance. Developing these BMIs requires advances in neuroscience and electronic technology, as well as using low-complexity spike detection algorithms and high-performance machine learning models. While some state-of-the-art BMI systems jointly design spike detection algorithms and machine learning models, it remains unclear how the detection performance affects decoding. Approach. We propose the co-design of the neural decoder with an ultra-low complexity spike detection algorithm. The detection algorithm is designed to attain a target firing rate, which the decoder uses to modulate the input features preserving statistical invariance in long term (over several months). Main results. We demonstrate a multiplication-free fixed-point spike detection algorithm with an average detection accuracy of 97% across different noise levels on a synthetic dataset and the lowest hardware complexity among studies we have seen. By co-designing the system to incorporate statistically invariant features, we observe significantly improved long-term stability, with decoding accuracy degrading by less than 10% after 80 days of operation. Our analysis also reveals a nonlinear relationship between spike detection and decoding performance. Increasing the detection sensitivity improves decoding accuracy and long-term stability, which means the activity of more neurons is beneficial despite the detection of more noise. Reducing the spike detection sensitivity still provides acceptable decoding accuracy whilst reducing the bandwidth by at least 30%. Significance. Our findings regarding the relationship between spike detection and decoding performance can provide guidance on setting the threshold for spike detection rather than relying on training or trial-and-error. The trade-off between data bandwidth and decoding performance can be effectively managed using appropriate spike detection settings. We demonstrate improved decoding performance by maintaining statistical invariance of input features. We believe this approach can motivate further research focused on improving decoding performance through the manipulation of data itself (based on a hypothesis) rather than using more complex decoding models.
- Open Access
Firing-rate-modulated spike detection and neural decoding co-design
Objective Translational efforts on spike-signal-based implantable brain-machine interfaces (BMIs) are increasingly aiming to minimise bandwidth while maintaining decoding performance. Developing these BMIs requires advances in neuroscience and electronic technology, as well as using low-complexity spike detection algorithms and high-performance machine learning models. While some state-of-the-art BMI systems jointly design spike detection algorithms and machine learning models, it remains unclear how the detection performance affects decoding. Approach We propose the co-design of the neural decoder with an ultra-low complexity spike detection algorithm. The detection algorithm is designed to attain a target firing rate, which the decoder uses to modulate the input features preserving statistical invariance. Main results We demonstrate a multiplication-free fixed-point spike detection algorithm with nearly perfect detection accuracy and the lowest complexity among studies we have seen. By co-designing the system to incorporate statistically invariant features, we observe significantly improved long-term stability, with decoding accuracy degrading by less than 10% after 80 days of operation. Our analysis also reveals a nonlinear relationship between spike detection and decoding performance. Increasing the detection sensitivity improves decoding accuracy and long-term stability, which means the activity of more neurons is beneficial despite the detection of more noise. Reducing the spike detection sensitivity still provides acceptable decoding accuracy whilst reducing the bandwidth by at least 30%. Significance Our findings regarding the relationship between spike detection and decoding performance can provide guidance on setting the threshold for spike detection rather than relying on training or trial-and-error. The trade-off between data bandwidth and decoding performance can be effectively managed using appropriate spike detection settings. We demonstrate improved decoding performance by maintaining statistical invariance of input features. We believe this approach can motivate further research focused on improving decoding performance through the manipulation of data itself (based on a hypothesis) rather than using more complex decoding models.
Open AccessFiring-rate-modulated spike detection and neural decoding co-design
Objective Translational efforts on spike-signal-based implantable brain-machine interfaces (BMIs) are increasingly aiming to minimise bandwidth while maintaining decoding performance. Developing these BMIs requires advances in neuroscience and electronic technology, as well as using low-complexity spike detection algorithms and high-performance machine learning models. While some state-of-the-art BMI systems jointly design spike detection algorithms and machine learning models, it remains unclear how the detection performance affects decoding. Approach We propose the co-design of the neural decoder with an ultra-low complexity spike detection algorithm. The detection algorithm is designed to attain a target firing rate, which the decoder uses to modulate the input features preserving statistical invariance. Main results We demonstrate a multiplication-free fixed-point spike detection algorithm with nearly perfect detection accuracy and the lowest complexity among studies we have seen. By co-designing the system to incorporate statistically invariant features, we observe significantly improved long-term stability, with decoding accuracy degrading by less than 10% after 80 days of operation. Our analysis also reveals a nonlinear relationship between spike detection and decoding performance. Increasing the detection sensitivity improves decoding accuracy and long-term stability, which means the activity of more neurons is beneficial despite the detection of more noise. Reducing the spike detection sensitivity still provides acceptable decoding accuracy whilst reducing the bandwidth by at least 30%. Significance Our findings regarding the relationship between spike detection and decoding performance can provide guidance on setting the threshold for spike detection rather than relying on training or trial-and-error. The trade-off between data bandwidth and decoding performance can be effectively managed using appropriate spike detection settings. We demonstrate improved decoding performance by maintaining statistical invariance of input features. We believe this approach can motivate further research focused on improving decoding performance through the manipulation of data itself (based on a hypothesis) rather than using more complex decoding models.
- Open Access
Ultra Low Power, Event-Driven Data Compression of Multi-Unit Activity
Recent years have demonstrated the feasibility of using intracortical Brain-Machine Interfaces (iBMIs), by decoding thoughts, for communication and cursor control tasks. iBMIs are increasingly becoming wireless due to the risk of infection and mechanical failure, typically associated with percutaneous connections. The wireless communication itself, however, increases the power consumption further; with the total dissipation being strictly limited due to safety heating limits of cortical tissue. Since wireless power is typically proportional to the communication bandwidth, the output Bit Rate (BR) must be minimised. Whilst most iBMIs utilise Multi-Unit activity (MUA), i.e. spike events, and this in itself significantly reduces the output BR (compared to raw data), it still limits the scalability (number of channels) that can be achieved. As such, additional compression for MUA signals are essential for fully-implantable, high-information-bandwidth systems. To meet this need, this work proposes various hardware-efficient, ultra-low power MUA compression schemes. We investigate them in terms of their BRs and hardware requirements as a function of various on-implant conditions such as MUA Binning Period (BP) and number of channels. It was found that for BPs ≤ 10 ms, the delta-asynchronous method had the lowest total power and reduced the BR by almost an order of magnitude relative to classical methods (e.g. to approx. 151 bps/channel for a BP of 1 ms and 1000 channels on-implant.). However, at larger BPs the synchronous method performed best (e.g. approx. 29 bps/channel for a BP of 50 ms, independent of channel count). As such, this work can guide the choice of MUA data compression scheme for BMI applications, where the BR can be significantly reduced in hardware efficient ways. This enables the next generation of wireless iBMIs, with small implant sizes, high channel counts, low-power, and small hardware footprint. All code and results have been made publicly available.
Open AccessUltra Low Power, Event-Driven Data Compression of Multi-Unit Activity
Recent years have demonstrated the feasibility of using intracortical Brain-Machine Interfaces (iBMIs), by decoding thoughts, for communication and cursor control tasks. iBMIs are increasingly becoming wireless due to the risk of infection and mechanical failure, typically associated with percutaneous connections. The wireless communication itself, however, increases the power consumption further; with the total dissipation being strictly limited due to safety heating limits of cortical tissue. Since wireless power is typically proportional to the communication bandwidth, the output Bit Rate (BR) must be minimised. Whilst most iBMIs utilise Multi-Unit activity (MUA), i.e. spike events, and this in itself significantly reduces the output BR (compared to raw data), it still limits the scalability (number of channels) that can be achieved. As such, additional compression for MUA signals are essential for fully-implantable, high-information-bandwidth systems. To meet this need, this work proposes various hardware-efficient, ultra-low power MUA compression schemes. We investigate them in terms of their BRs and hardware requirements as a function of various on-implant conditions such as MUA Binning Period (BP) and number of channels. It was found that for BPs ≤ 10 ms, the delta-asynchronous method had the lowest total power and reduced the BR by almost an order of magnitude relative to classical methods (e.g. to approx. 151 bps/channel for a BP of 1 ms and 1000 channels on-implant.). However, at larger BPs the synchronous method performed best (e.g. approx. 29 bps/channel for a BP of 50 ms, independent of channel count). As such, this work can guide the choice of MUA data compression scheme for BMI applications, where the BR can be significantly reduced in hardware efficient ways. This enables the next generation of wireless iBMIs, with small implant sizes, high channel counts, low-power, and small hardware footprint. All code and results have been made publicly available.
- Open Access
- 4 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 117515-117529
Hardware-Efficient Compression of Neural Multi-Unit Activity
Brain-machine interfaces (BMI) are tools for treating neurological disorders and motor-impairments. It is essential that the next generation of intracortical BMIs is wireless so as to remove percutaneous connections, i.e. wires, and the associated mechanical and infection risks. This is required for the effective translation of BMIs into clinical applications and is one of the remaining bottlenecks. However, due to cortical tissue thermal dissipation safety limits, the on-implant power consumption must be strictly limited. Therefore, both the neural signal processing and wireless communication power should be minimal, while the implants should provide signals that offer high behavioural decoding performance (BDP). The Multi-Unit Activity (MUA) signal is the most common signal in modern BMIs. However, with an ever-increasing channel count, the raw data bandwidth is becoming prohibitively high due to the associated communication power exceeding the safety limits. Data compression is therefore required. To meet this need, this work developed hardware-efficient static Huffman compression schemes for MUA data. Our final system reduced the bandwidth to 27 bps/channel, compared to the standard MUA rate of 1 kbps/channel. This compression is over an order of magnitude more than has been achieved before, while using only 0.96 uW/channel processing power and 246 logic cells. Our results were verified on 3 datasets and less than 1% loss in BDP was observed. As such, with the use of effective data compression, an order more of MUA channels can be fitted on-implant, enabling the next generation of high-performance wireless intracortical BMIs.
- 4 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 117515-117529
Open AccessHardware-Efficient Compression of Neural Multi-Unit Activity
Brain-machine interfaces (BMI) are tools for treating neurological disorders and motor-impairments. It is essential that the next generation of intracortical BMIs is wireless so as to remove percutaneous connections, i.e. wires, and the associated mechanical and infection risks. This is required for the effective translation of BMIs into clinical applications and is one of the remaining bottlenecks. However, due to cortical tissue thermal dissipation safety limits, the on-implant power consumption must be strictly limited. Therefore, both the neural signal processing and wireless communication power should be minimal, while the implants should provide signals that offer high behavioural decoding performance (BDP). The Multi-Unit Activity (MUA) signal is the most common signal in modern BMIs. However, with an ever-increasing channel count, the raw data bandwidth is becoming prohibitively high due to the associated communication power exceeding the safety limits. Data compression is therefore required. To meet this need, this work developed hardware-efficient static Huffman compression schemes for MUA data. Our final system reduced the bandwidth to 27 bps/channel, compared to the standard MUA rate of 1 kbps/channel. This compression is over an order of magnitude more than has been achieved before, while using only 0.96 uW/channel processing power and 246 logic cells. Our results were verified on 3 datasets and less than 1% loss in BDP was observed. As such, with the use of effective data compression, an order more of MUA channels can be fitted on-implant, enabling the next generation of high-performance wireless intracortical BMIs.
- Open Access
Hardware evaluation of spike detection algorithms towards wireless brain machine interfaces
The current trend for implantable Brain Machine Interfaces (BMIs) is to increase the channel count, towards next generation devices that improve on information transfer rate. This however increases the raw data bandwidth for wired or wireless systems that ultimately impacts the power budget (and thermal dissipation). On-implant feature extraction and/or compression are therefore becoming essential to reduce the data rate, however the processing power is of concern. One common feature extraction technique for intracortical BMIs is spike detection. In this work, we have empirically compared the performance, resource utilization, and power consumption of three hardware efficient spike emphasizers, Non-linear Energy Operator (NEO), Amplitude Slope Operator (ASO) and Energy of Derivative (ED), and two common statistical thresholding mechanisms (using mean or median). We also propose a novel median approximation to address the issue of the median operator not being hardware-efficient to implement. These have all been implemented and evaluated on reconfigurable hardware (FPGA) to estimate their hardware efficiency in an ultimate ASIC design. Our results suggest that ED with average thresholding provides the most hardware efficient (low power/resource) choice, while using median has the advantage of improved detection accuracy and higher robustness on threshold multiplier settings. This work is significant because it is the first to implement and compare the hardware and algorithm trade-offs that have to be made before translating the algorithms into hardware instances to design wireless implantable BMIs.
Open AccessHardware evaluation of spike detection algorithms towards wireless brain machine interfaces
The current trend for implantable Brain Machine Interfaces (BMIs) is to increase the channel count, towards next generation devices that improve on information transfer rate. This however increases the raw data bandwidth for wired or wireless systems that ultimately impacts the power budget (and thermal dissipation). On-implant feature extraction and/or compression are therefore becoming essential to reduce the data rate, however the processing power is of concern. One common feature extraction technique for intracortical BMIs is spike detection. In this work, we have empirically compared the performance, resource utilization, and power consumption of three hardware efficient spike emphasizers, Non-linear Energy Operator (NEO), Amplitude Slope Operator (ASO) and Energy of Derivative (ED), and two common statistical thresholding mechanisms (using mean or median). We also propose a novel median approximation to address the issue of the median operator not being hardware-efficient to implement. These have all been implemented and evaluated on reconfigurable hardware (FPGA) to estimate their hardware efficiency in an ultimate ASIC design. Our results suggest that ED with average thresholding provides the most hardware efficient (low power/resource) choice, while using median has the advantage of improved detection accuracy and higher robustness on threshold multiplier settings. This work is significant because it is the first to implement and compare the hardware and algorithm trade-offs that have to be made before translating the algorithms into hardware instances to design wireless implantable BMIs.
- Open Access
Hardware-Efficient Compression of Neural Multi-Unit Activity
Objective Recent advances in intracortical brain machine interfaces (iBMIs) have demonstrated the feasibility of using our thoughts; by sensing and decoding neural activity, for communication and cursor control tasks. It is essential that any invasive device is completely wireless so as to remove percutaneous connections and the associated infection risks. However, wireless communication consumes significant power and there are strict heating limits in cortical tissue. Most iBMIs use Multi Unit Activity (MUA) processing, however the required bandwidth can be excessive for large channel counts in mm or submm scale implants. As such, some form of data compression for MUA iBMIs is desirable. Approach We used a Machine Learning approach to select static Huffman encoders that worked together, and investigated a broad range of resulting compression systems. They were implemented in reconfigurable hardware and their power consumption, resource utilization and compression performance measured. Main Results Our design results identified a specific system that provided top performance. We tested it on data from 3 datasets, and found that, with less than 1% behavioural decoding performance reduction from peak, the communication bandwidth was reduced from 1 kb/s/channel to approximately 27 bits/s/channel, using only a Look-Up Table and a 50 ms temporal resolution for threshold crossings. Relative to raw broadband data, this is a compression ratio of 1700-15,000 × and is over an order of magnitude higher than has achieved before. Assuming 20 nJ per communicated bit, the total compression and communication power was between 1.37 and 1.52 μW/channel, occupying 246 logic cells and 4 kbit RAM supporting up to 512-channels. Significance We show that MUA data can be significantly compressed in a hardware efficient manner, ‘out of the box’ with no calibration necessary. This can significantly reduce onimplant power consumption and enable much larger channel counts in WI-BMIs. All results, code and hardware designs have been made publicly available.
Open AccessHardware-Efficient Compression of Neural Multi-Unit Activity
Objective Recent advances in intracortical brain machine interfaces (iBMIs) have demonstrated the feasibility of using our thoughts; by sensing and decoding neural activity, for communication and cursor control tasks. It is essential that any invasive device is completely wireless so as to remove percutaneous connections and the associated infection risks. However, wireless communication consumes significant power and there are strict heating limits in cortical tissue. Most iBMIs use Multi Unit Activity (MUA) processing, however the required bandwidth can be excessive for large channel counts in mm or submm scale implants. As such, some form of data compression for MUA iBMIs is desirable. Approach We used a Machine Learning approach to select static Huffman encoders that worked together, and investigated a broad range of resulting compression systems. They were implemented in reconfigurable hardware and their power consumption, resource utilization and compression performance measured. Main Results Our design results identified a specific system that provided top performance. We tested it on data from 3 datasets, and found that, with less than 1% behavioural decoding performance reduction from peak, the communication bandwidth was reduced from 1 kb/s/channel to approximately 27 bits/s/channel, using only a Look-Up Table and a 50 ms temporal resolution for threshold crossings. Relative to raw broadband data, this is a compression ratio of 1700-15,000 × and is over an order of magnitude higher than has achieved before. Assuming 20 nJ per communicated bit, the total compression and communication power was between 1.37 and 1.52 μW/channel, occupying 246 logic cells and 4 kbit RAM supporting up to 512-channels. Significance We show that MUA data can be significantly compressed in a hardware efficient manner, ‘out of the box’ with no calibration necessary. This can significantly reduce onimplant power consumption and enable much larger channel counts in WI-BMIs. All results, code and hardware designs have been made publicly available.
- Open Access
- 1 February 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (1) , 016029
Algorithm and hardware considerations for real-time neural signal on-implant processing
Objective. Various on-workstation neural-spike-based brain machine interface (BMI) systems have reached the point of in-human trials, but on-node and on-implant BMI systems are still under exploration. Such systems are constrained by the area and battery. Researchers should consider the algorithm complexity, available resources, power budgets, CMOS technologies, and the choice of platforms when designing BMI systems. However, the effect of these factors is currently still unclear. Approaches. Here we have proposed a novel real-time 128 channel spike detection algorithm and optimised it on microcontroller (MCU) and field programmable gate array (FPGA) platforms towards consuming minimal power and memory/resources. It is presented as a use case to explore the different considerations in system design. Main results. The proposed spike detection algorithm achieved over 97% sensitivity and a smaller than 3% false detection rate. The MCU implementation occupies less than 3 KB RAM and consumes 31.5 µW ch−1. The FPGA platform only occupies 299 logic cells and 3 KB RAM for 128 channels and consumes 0.04 µW ch−1. Significance. On the spike detection algorithm front, we have eliminated the processing bottleneck by reducing the dynamic power consumption to lower than the hardware static power, without sacrificing detection performance. More importantly, we have explored the considerations in algorithm and hardware design with respect to scalability, portability, and costs. These findings can facilitate and guide the future development of real-time on-implant neural signal processing platforms.
- 1 February 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (1) , 016029
Open AccessAlgorithm and hardware considerations for real-time neural signal on-implant processing
Objective. Various on-workstation neural-spike-based brain machine interface (BMI) systems have reached the point of in-human trials, but on-node and on-implant BMI systems are still under exploration. Such systems are constrained by the area and battery. Researchers should consider the algorithm complexity, available resources, power budgets, CMOS technologies, and the choice of platforms when designing BMI systems. However, the effect of these factors is currently still unclear. Approaches. Here we have proposed a novel real-time 128 channel spike detection algorithm and optimised it on microcontroller (MCU) and field programmable gate array (FPGA) platforms towards consuming minimal power and memory/resources. It is presented as a use case to explore the different considerations in system design. Main results. The proposed spike detection algorithm achieved over 97% sensitivity and a smaller than 3% false detection rate. The MCU implementation occupies less than 3 KB RAM and consumes 31.5 µW ch−1. The FPGA platform only occupies 299 logic cells and 3 KB RAM for 128 channels and consumes 0.04 µW ch−1. Significance. On the spike detection algorithm front, we have eliminated the processing bottleneck by reducing the dynamic power consumption to lower than the hardware static power, without sacrificing detection performance. More importantly, we have explored the considerations in algorithm and hardware design with respect to scalability, portability, and costs. These findings can facilitate and guide the future development of real-time on-implant neural signal processing platforms.
- Open Access
Development of an Ultra Low-Cost SSVEP-based BCI Device for Real-Time On-Device Decoding
This study details the development of a novel, approx. £20 electroencephalogram (EEG)-based brain-computer interface (BCI) intended to offer a financially and operationally accessible device that can be deployed on a mass scale to facilitate education and public engagement in the domain of EEG sensing and neurotechnologies. Real-time decoding of steady-state visual evoked potentials (SSVEPs) is achieved using variations of the widely-used canonical correlation analysis (CCA) algorithm: multi-set CCA and generalised CCA. All BCI functionality is executed on board an inexpensive ESP32 microcontroller. SSVEP decoding accuracy of 95.56 ± 3.74% with an ITR of 102 bits/min was achieved with modest calibration.
Open AccessDevelopment of an Ultra Low-Cost SSVEP-based BCI Device for Real-Time On-Device Decoding
This study details the development of a novel, approx. £20 electroencephalogram (EEG)-based brain-computer interface (BCI) intended to offer a financially and operationally accessible device that can be deployed on a mass scale to facilitate education and public engagement in the domain of EEG sensing and neurotechnologies. Real-time decoding of steady-state visual evoked potentials (SSVEPs) is achieved using variations of the widely-used canonical correlation analysis (CCA) algorithm: multi-set CCA and generalised CCA. All BCI functionality is executed on board an inexpensive ESP32 microcontroller. SSVEP decoding accuracy of 95.56 ± 3.74% with an ITR of 102 bits/min was achieved with modest calibration.
- Open Access
Selecting an effective amplitude threshold for neural spike detection
This paper assesses and challenges whether commonly used methods for defining amplitude thresholds for spike detection are optimal. This is achieved through empirical testing of single amplitude thresholds across multiple recordings of varying SNR levels. Our results suggest that the most widely used noise-statistics-driven threshold can suffer from parameter deviation in different noise levels. The spike-noise-driven threshold can be an ideal approach to set the threshold for spike detection, which suffers less from the parameter deviation and is robust to sub-optimal settings.
Open AccessSelecting an effective amplitude threshold for neural spike detection
This paper assesses and challenges whether commonly used methods for defining amplitude thresholds for spike detection are optimal. This is achieved through empirical testing of single amplitude thresholds across multiple recordings of varying SNR levels. Our results suggest that the most widely used noise-statistics-driven threshold can suffer from parameter deviation in different noise levels. The spike-noise-driven threshold can be an ideal approach to set the threshold for spike detection, which suffers less from the parameter deviation and is robust to sub-optimal settings.