Shahbaz Ahmed Qazi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shahbaz Ahmed Qazi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Muhammad Arabi
King Abdul Aziz Medical City National Guards Health Affairs, Riyadh, Saudi Arabia
2 shared publicationsOmar Bashir
King Abdul Aziz Medical City National Guards Health Affairs, Riyadh, Saudi Arabia
2 shared publicationsAbdul Aziz Harbi
King Abdul Aziz Medical City National Guards Health Affairs, Riyadh, Saudi Arabia
1 shared publicationAbdullah T. Tatwani
Medical Education, College of Medicine - King Saud Bin Abdulaziz University for Health Sciences, Riyadh, SAU
1 shared publication- Bader AlMutairi
NGHA, Riyadh, Saudi Arabia
1 shared publication - Johara AlMulhim
King Faisal University, Ahsa, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 28 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e22692
Trans-Biliary Gastric Outlet Recanalization and Stenting: A Case Report
Gastric ischemia is a condition of hypo-perfusion associated with hypotension, vasculitis, and thromboembolism. We report a case of a gastric outflow obstruction due to sizeable visceral artery thrombo-embolism leading to the ischemic conclusion, the frailty, multiple comorbidities deeming general anesthesia (GA) risky, and the patient’s decision not to have an open surgery under GA. Invasive procedures in patients with similar profiles like our patient are usually not risk-free, this leads the intervention radiology team to believe a minimally invasive procedure while avoiding GA might be optimal. A 63-year-old female with multiple comorbidities came eight weeks after significant surgery complaining of severe acute epigastric pain, abdominal distention and rigidity, and persistent vomiting. Further investigations showed obstruction in the gastric antrum and pyloric canal. Three separate endoscopic attempts to find and cross the stricture failed. Firstly, gastrostomy access was established, but due to the stomach being massively distended, passing a guidewire through the pylorus failed despite using multiple hydrophilic wires and pre-shaped catheters, this is due to the collapsed pylorus. Subsequently, two attempts under ultrasound guidance to puncture the duodenal bulb and pass a wire and catheter through the antrum stricture were unsuccessful, and another attempt was considered of high risk. An alternative approach through the gallbladder was established, and cholangiography was performed to delineate the anatomy. Then an approach through the right hepatic duct and ampulla of Vater was successfully performed. The attempted passage through the stricture was successful. The dilation was successful, and the patient tolerated both fluid and solids orally. Due to having such a frail patient, interventions of minimal invasiveness and favorable outcome are welcomed. This case report suggests that this technique showed satisfactory results and achieved the goal to improve the overall quality of life where the patient had a good oral intake with no post-operation complications.
- 28 February 2022
- Published by Springer Nature in Cureus
- Vol. 14 (2) , e22692
Open AccessTrans-Biliary Gastric Outlet Recanalization and Stenting: A Case Report
Gastric ischemia is a condition of hypo-perfusion associated with hypotension, vasculitis, and thromboembolism. We report a case of a gastric outflow obstruction due to sizeable visceral artery thrombo-embolism leading to the ischemic conclusion, the frailty, multiple comorbidities deeming general anesthesia (GA) risky, and the patient’s decision not to have an open surgery under GA. Invasive procedures in patients with similar profiles like our patient are usually not risk-free, this leads the intervention radiology team to believe a minimally invasive procedure while avoiding GA might be optimal. A 63-year-old female with multiple comorbidities came eight weeks after significant surgery complaining of severe acute epigastric pain, abdominal distention and rigidity, and persistent vomiting. Further investigations showed obstruction in the gastric antrum and pyloric canal. Three separate endoscopic attempts to find and cross the stricture failed. Firstly, gastrostomy access was established, but due to the stomach being massively distended, passing a guidewire through the pylorus failed despite using multiple hydrophilic wires and pre-shaped catheters, this is due to the collapsed pylorus. Subsequently, two attempts under ultrasound guidance to puncture the duodenal bulb and pass a wire and catheter through the antrum stricture were unsuccessful, and another attempt was considered of high risk. An alternative approach through the gallbladder was established, and cholangiography was performed to delineate the anatomy. Then an approach through the right hepatic duct and ampulla of Vater was successfully performed. The attempted passage through the stricture was successful. The dilation was successful, and the patient tolerated both fluid and solids orally. Due to having such a frail patient, interventions of minimal invasiveness and favorable outcome are welcomed. This case report suggests that this technique showed satisfactory results and achieved the goal to improve the overall quality of life where the patient had a good oral intake with no post-operation complications.
- Open Access
- 1 March 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (3) , 560-563
Retrohepatic IVC injury: A new treatment approach with arterial stent graft
- 1 March 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (3) , 560-563
Open AccessRetrohepatic IVC injury: A new treatment approach with arterial stent graft
- Open Access
- 1 February 2019
- Published by Georg Thieme Verlag KG in The Arab Journal of Interventional Radiology
- Vol. 03 (03) , P434
Hepatic Artery Stenosis in Liver Transplant Recipient’s Angioplasty and Stenting a Single Center Experience
Background: Significant hepatic artery stenosis after liver transplantation can lead to thrombosis with associated high morbidity and mortality. The aim of our study is to evaluate our technical success rate, clinical outcomes and complications. Method(s): It’s a retrospective study in 13 patients who underwent liver transplantation between 2010 and 2018. Recipients demographics, type of liver transplant, clinical presentations methods of diagnosing hepatic artery stenosis, types of anastomosis, approached for intervention, hepatic artery stenosis grading, primary angioplasty and in some cases assisted stenting were evaluated. All patients were assessed after intervention by clinical outcomes, Doppler examination. Result(s): Out of 13 patients, 5 patients after angioplasty were assisted by stenting, 11 patients have good flow (84%), in 1 patient no change in flow and 1 have poor flow,1 patient complicated by non flow limiting dissection, 1 underwent for surgical redo, 10 patients are still alive. Conclusion(s): Our results suggest hepatic artery angioplasty and stenting in liver recipients are minimally and safe procedures good alternative option to open surgeries. Publication Date: 11 May 2021 (online) © 2019. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 February 2019
- Published by Georg Thieme Verlag KG in The Arab Journal of Interventional Radiology
- Vol. 03 (03) , P434
Open AccessHepatic Artery Stenosis in Liver Transplant Recipient’s Angioplasty and Stenting a Single Center Experience
Background: Significant hepatic artery stenosis after liver transplantation can lead to thrombosis with associated high morbidity and mortality. The aim of our study is to evaluate our technical success rate, clinical outcomes and complications. Method(s): It’s a retrospective study in 13 patients who underwent liver transplantation between 2010 and 2018. Recipients demographics, type of liver transplant, clinical presentations methods of diagnosing hepatic artery stenosis, types of anastomosis, approached for intervention, hepatic artery stenosis grading, primary angioplasty and in some cases assisted stenting were evaluated. All patients were assessed after intervention by clinical outcomes, Doppler examination. Result(s): Out of 13 patients, 5 patients after angioplasty were assisted by stenting, 11 patients have good flow (84%), in 1 patient no change in flow and 1 have poor flow,1 patient complicated by non flow limiting dissection, 1 underwent for surgical redo, 10 patients are still alive. Conclusion(s): Our results suggest hepatic artery angioplasty and stenting in liver recipients are minimally and safe procedures good alternative option to open surgeries. Publication Date: 11 May 2021 (online) © 2019. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- Open Access
- 1 August 2018
- Published by Georg Thieme Verlag KG
- Vol. 02 (03) , OC401
Removal of Embedded Tunneled Hemodialysis Catheters Using Endoluminal Balloon Dilatation: A Single-Center Experience
Background: Increasing frequency of tunneled hemodialysis catheter usage increases the burden for removal or exchange. A small proportion of dialysis catheter failed to be removed by conventional techniques. Methods: We retrospectively report a series of 12 cases in our institution between September 2015 and December 2017 who failed removal of tunneled dialysis catheters by conventional methods. The study cohort included 11 males and 1 female with mean age of 44 (12–90 years). The mean catheter dwelling time was 770 (153–1442 days). Reason for catheter removal included dysfunctional catheter (n = 5), line sepsis (n = 4), and switching to functioning fistula (n = 1). Catheter types included GlidePath Bard (n = 2), Vaxel Boston Scientific (n = 2), HemoStar Bard PV (n = 2), Palindrome Medtronic (n = 2), Equistream Bard (n = 1), Medcomp (n = 1), and unknown catheter. The insertion sites were internal jugular vein (n = 11) and femoral vein (n = 1). Nine cases were performed under local and 3 under general anesthesia. Single-lumen endoluminal balloon dilatation is done in eight cases and double-lumen dilatation in four cases. Low profile 0.018” or 0.014” balloons ranging from 5–8 mm were used. Results: All catheters were removed safely without any minor or major adverse events. In one case, the catheter was shredded completely but removed over the balloon with no complications. Conclusion: Minimally invasive endoluminal balloon dilatation of tunneled dialysis catheter is a safe and effective technique for removing embedded catheters. Publication Date: 11 May 2021 (online) © 2018. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 1 August 2018
- Published by Georg Thieme Verlag KG
- Vol. 02 (03) , OC401
Open AccessRemoval of Embedded Tunneled Hemodialysis Catheters Using Endoluminal Balloon Dilatation: A Single-Center Experience
Background: Increasing frequency of tunneled hemodialysis catheter usage increases the burden for removal or exchange. A small proportion of dialysis catheter failed to be removed by conventional techniques. Methods: We retrospectively report a series of 12 cases in our institution between September 2015 and December 2017 who failed removal of tunneled dialysis catheters by conventional methods. The study cohort included 11 males and 1 female with mean age of 44 (12–90 years). The mean catheter dwelling time was 770 (153–1442 days). Reason for catheter removal included dysfunctional catheter (n = 5), line sepsis (n = 4), and switching to functioning fistula (n = 1). Catheter types included GlidePath Bard (n = 2), Vaxel Boston Scientific (n = 2), HemoStar Bard PV (n = 2), Palindrome Medtronic (n = 2), Equistream Bard (n = 1), Medcomp (n = 1), and unknown catheter. The insertion sites were internal jugular vein (n = 11) and femoral vein (n = 1). Nine cases were performed under local and 3 under general anesthesia. Single-lumen endoluminal balloon dilatation is done in eight cases and double-lumen dilatation in four cases. Low profile 0.018” or 0.014” balloons ranging from 5–8 mm were used. Results: All catheters were removed safely without any minor or major adverse events. In one case, the catheter was shredded completely but removed over the balloon with no complications. Conclusion: Minimally invasive endoluminal balloon dilatation of tunneled dialysis catheter is a safe and effective technique for removing embedded catheters. Publication Date: 11 May 2021 (online) © 2018. The Arab Journal of Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India