Yichao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yichao Wang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Gaoxiang Li
Guangxi University
2 shared publications Xiangqi Li
State Grid Hunan Electric Power Company Limited Economic & Technical Research Institute Changsha People's Republic of China
2 shared publications- Yandong Chen
Hunan University
2 shared publications An Luo
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publicationDongrong Wang
China Power International Development Limited Beijing China
1 shared publication- Fujun Ma
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication
Latest Publications
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 13 (2) , 524-535
A Current-Limiting Scheme for Voltage-Controlled Inverter Using Instantaneous Current to Generate Virtual Impedance
In this paper, a current-limiting scheme is proposed for the voltage-controlled inverter. The method utilizes instantaneous current to quickly activate a resistive fault-current-limiting virtual impedance (R FCL ) to suppress the instantaneous impulse current and steady-state overload current, which can be directly integrated into the existing voltage-type control scheme. When a fault occurs, the inverter can be kept in the voltage control mode without mode switching. After the fault is cleared, it can automatically return to the normal operation mode. The parameter selection method of the current-limiting virtual impedance is analyzed, and the logic criterion for short-circuit fault clearance is presented to realize the automatic startup and exit of the current-limiting virtual impedance. Finally, the RT-LAB hardware in-loop experiment and the single-phase inverter platform experiment prove that the proposed current-limiting scheme can simplify the fault handling process and improve the anti-fault ability of the voltage-controlled inverter.
- 24 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
- Vol. 13 (2) , 524-535
A Current-Limiting Scheme for Voltage-Controlled Inverter Using Instantaneous Current to Generate Virtual Impedance
In this paper, a current-limiting scheme is proposed for the voltage-controlled inverter. The method utilizes instantaneous current to quickly activate a resistive fault-current-limiting virtual impedance (R FCL ) to suppress the instantaneous impulse current and steady-state overload current, which can be directly integrated into the existing voltage-type control scheme. When a fault occurs, the inverter can be kept in the voltage control mode without mode switching. After the fault is cleared, it can automatically return to the normal operation mode. The parameter selection method of the current-limiting virtual impedance is analyzed, and the logic criterion for short-circuit fault clearance is presented to realize the automatic startup and exit of the current-limiting virtual impedance. Finally, the RT-LAB hardware in-loop experiment and the single-phase inverter platform experiment prove that the proposed current-limiting scheme can simplify the fault handling process and improve the anti-fault ability of the voltage-controlled inverter.
- Open Access
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Hybrid voltage and current control strategy for virtual synchronous generator under unbalanced voltage conditions
The traditional VSG strategy does not consider the negative sequence component, which will lead to current imbalance and power oscillation under unbalanced voltage. Several improved control strategies of VSG are usable for operating under unbalanced voltage nowadays. These control strategies usually require a complex PLL (phase‐locked loop) to detect sequence components, and a current reference generator to convert voltage references to current references. This paper proposes an improved control strategy for VSG. The main contributions are in threefold: (1) A hybrid voltage and current control strategy by simultaneously controlling the positive sequence output voltage and negative sequence output current is proposed, which can achieve different operation demands under unbalanced voltage conditions without changing the original characteristics of VSG. (2) A positive and negative sequence decoupling method is designed to acquire the synchronization phase information directly from the positive sequence voltage control branch, thereby avoiding the use of complex PLL (phase locked loop). (3) A general formulation for the negative sequence current references is presented to control the power oscillations or the current balance flexibly. The correctness and effectiveness of the control strategy are verified by simulation and experimental results.
- 15 June 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessHybrid voltage and current control strategy for virtual synchronous generator under unbalanced voltage conditions
The traditional VSG strategy does not consider the negative sequence component, which will lead to current imbalance and power oscillation under unbalanced voltage. Several improved control strategies of VSG are usable for operating under unbalanced voltage nowadays. These control strategies usually require a complex PLL (phase‐locked loop) to detect sequence components, and a current reference generator to convert voltage references to current references. This paper proposes an improved control strategy for VSG. The main contributions are in threefold: (1) A hybrid voltage and current control strategy by simultaneously controlling the positive sequence output voltage and negative sequence output current is proposed, which can achieve different operation demands under unbalanced voltage conditions without changing the original characteristics of VSG. (2) A positive and negative sequence decoupling method is designed to acquire the synchronization phase information directly from the positive sequence voltage control branch, thereby avoiding the use of complex PLL (phase locked loop). (3) A general formulation for the negative sequence current references is presented to control the power oscillations or the current balance flexibly. The correctness and effectiveness of the control strategy are verified by simulation and experimental results.
- Open Access
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 94912-94922
Frequency Coupling Admittance Modeling of Quasi-PR Controlled Inverter and Its Stability Comparative Analysis Under the Weak Grid
This paper intends to comparatively study the stabilities of grid-connected inverters with three closely related controllers: quasi-proportional resonance (quasi-PR), proportional integral (PI), and proportional resonance (PR) under the weak grid. Firstly, considering the influence of frequency coupling characteristic, a frequency coupling admittance model of quasi-PR controlled inverter is established. Then, the admittance characteristics of the quasi-PR, PI and PR controlled inverters are compared. Admittance characteristics of the PI and PR controlled inverters are similar while the quasi-PR controlled inverter is quite different: the amplitude of the quasi-PR controlled inverter is larger than that of the PI controlled inverter and the phase difference between the two inverters is obvious in the mid-high frequency areas, which are mainly caused by the resonance bandwidth of the quasi-PR controller. Furthermore, the stabilities of the quasi-PR, PI and PR controlled inverters are analyzed. The stabilities of the PI and PR controlled inverters are similar but the quasi-PR controlled inverter is more sensitive to weak grid and high inverter output power. To achieve the same system stability, the voltage outer-loop bandwidth of the quasi-PR controlled inverter should be designed narrower than that of the PI and PR controlled inverters. Finally, experiments verify the correctness of the analyses.
- 29 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 94912-94922
Open AccessFrequency Coupling Admittance Modeling of Quasi-PR Controlled Inverter and Its Stability Comparative Analysis Under the Weak Grid
This paper intends to comparatively study the stabilities of grid-connected inverters with three closely related controllers: quasi-proportional resonance (quasi-PR), proportional integral (PI), and proportional resonance (PR) under the weak grid. Firstly, considering the influence of frequency coupling characteristic, a frequency coupling admittance model of quasi-PR controlled inverter is established. Then, the admittance characteristics of the quasi-PR, PI and PR controlled inverters are compared. Admittance characteristics of the PI and PR controlled inverters are similar while the quasi-PR controlled inverter is quite different: the amplitude of the quasi-PR controlled inverter is larger than that of the PI controlled inverter and the phase difference between the two inverters is obvious in the mid-high frequency areas, which are mainly caused by the resonance bandwidth of the quasi-PR controller. Furthermore, the stabilities of the quasi-PR, PI and PR controlled inverters are analyzed. The stabilities of the PI and PR controlled inverters are similar but the quasi-PR controlled inverter is more sensitive to weak grid and high inverter output power. To achieve the same system stability, the voltage outer-loop bandwidth of the quasi-PR controlled inverter should be designed narrower than that of the PI and PR controlled inverters. Finally, experiments verify the correctness of the analyses.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 4621-4631
An Inertia Phase Locked Loop for Suppressing Sub-Synchronous Resonance of Renewable Energy Generation System Under Weak Grid
Due to impedance interaction, the sub-synchronous resonance (SSR) issue of the renewable energy generation (REG) system connected to weak grid has recently become prominent. Firstly, the mechanism and characteristics of the SSR occurring in the REG system under weak grid are analyzed based on the impedance method. With the decline of grid stiffness, the REG system can easily cause SSR owing to the impedance interaction between the inductive grid impedance and the capacitive REG system impedance in the low frequency range. To suppress this SSR, an inertia phase locked loop (IPLL) is proposed, which can optimize the impedance of the REG system in the low frequency range. According to the impedance based SSR analysis, the REG system with the proposed IPLL can hardly cause SSR under weak grid. Moreover, the mechanism, characteristics and design method of the proposed IPLL is introduced in detail. By using the proposed IPLL, the SSR issue of the REG system under weak grid can be effectively solved. Finally, the theoretical analysis and the proposed mitigation method of SSR are validated with the simulation and experimental study.
- 17 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 36 (5) , 4621-4631
An Inertia Phase Locked Loop for Suppressing Sub-Synchronous Resonance of Renewable Energy Generation System Under Weak Grid
Due to impedance interaction, the sub-synchronous resonance (SSR) issue of the renewable energy generation (REG) system connected to weak grid has recently become prominent. Firstly, the mechanism and characteristics of the SSR occurring in the REG system under weak grid are analyzed based on the impedance method. With the decline of grid stiffness, the REG system can easily cause SSR owing to the impedance interaction between the inductive grid impedance and the capacitive REG system impedance in the low frequency range. To suppress this SSR, an inertia phase locked loop (IPLL) is proposed, which can optimize the impedance of the REG system in the low frequency range. According to the impedance based SSR analysis, the REG system with the proposed IPLL can hardly cause SSR under weak grid. Moreover, the mechanism, characteristics and design method of the proposed IPLL is introduced in detail. By using the proposed IPLL, the SSR issue of the REG system under weak grid can be effectively solved. Finally, the theoretical analysis and the proposed mitigation method of SSR are validated with the simulation and experimental study.
- Open Access
- 1 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (11) , 2274-2280
Power‐current coordinated control without sequence extraction under unbalanced voltage conditions
The increasing penetration of renewable power sources into power system is calling for an evolution of grid interconnection control strategy. In particular, during asymmetrical grid faults, power turbulence and current distortion of three‐phase inverter cannot be balanced unless coordinated control is adopted. Several coordinated control strategies are usable for operating under unbalanced grid voltage nowadays. These control strategies usually require a real‐time sequence detection block for reference generation. This study explores a coordinated control strategy without real‐time sequence detection. It has three theoretical innovations: (i) the internal mathematical connection between power fluctuation and current quality is derived; (ii) a control strategy with a continuous adjustable factor is proposed. The power oscillations and the current quality can be controlled flexibly by adjustment factor without using the filter and sequence extraction calculation; (iii) the method for selecting the continuous adjustable factor is also presented. The experiment and simulation results prove that these innovations facilitate power‐current coordinated control with simple reference selection criteria and excellent performance.
- 1 August 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (11) , 2274-2280
Open AccessPower‐current coordinated control without sequence extraction under unbalanced voltage conditions
The increasing penetration of renewable power sources into power system is calling for an evolution of grid interconnection control strategy. In particular, during asymmetrical grid faults, power turbulence and current distortion of three‐phase inverter cannot be balanced unless coordinated control is adopted. Several coordinated control strategies are usable for operating under unbalanced grid voltage nowadays. These control strategies usually require a real‐time sequence detection block for reference generation. This study explores a coordinated control strategy without real‐time sequence detection. It has three theoretical innovations: (i) the internal mathematical connection between power fluctuation and current quality is derived; (ii) a control strategy with a continuous adjustable factor is proposed. The power oscillations and the current quality can be controlled flexibly by adjustment factor without using the filter and sequence extraction calculation; (iii) the method for selecting the continuous adjustable factor is also presented. The experiment and simulation results prove that these innovations facilitate power‐current coordinated control with simple reference selection criteria and excellent performance.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 3835-3845
Design and Operation Analysis of Virtual Synchronous Compensator
To reduce the sensitivity of static synchronous compensator (STATCOM) to power or voltage fluctuation induced by renewable energy generation or grid itself, it can add inertia for reactive compensation. Analogizing the virtual synchronous generator (VSG), a virtual synchronous compensator (VSCOM) is proposed in this article, which adds virtual inertia in reactive power regulation. According to the differences and the respective characteristics of VSG and VSCOM, a proportional-differential (PD) controller is proposed to achieve the fast control of dc-side voltage and cooperates with a series integrator to achieve the stable control of dc voltage. Meanwhile, an integral controller is designed for realizing the inertial control of reactive power. The small-signal model of the proposed VSCOM is built, and the design method of the control parameters is analyzed. Meanwhile, the inertial performance of the proposed VSCOM with different control parameters is analyzed from the unit-step response. In weak grid or multiple parallel devices, the proposed VSCOM is more stable than the typical STATCOM in direct reactive power control mode. Finally, experimental results validate the proposed control strategy and parameter design method.
- 25 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 8 (4) , 3835-3845
Design and Operation Analysis of Virtual Synchronous Compensator
To reduce the sensitivity of static synchronous compensator (STATCOM) to power or voltage fluctuation induced by renewable energy generation or grid itself, it can add inertia for reactive compensation. Analogizing the virtual synchronous generator (VSG), a virtual synchronous compensator (VSCOM) is proposed in this article, which adds virtual inertia in reactive power regulation. According to the differences and the respective characteristics of VSG and VSCOM, a proportional-differential (PD) controller is proposed to achieve the fast control of dc-side voltage and cooperates with a series integrator to achieve the stable control of dc voltage. Meanwhile, an integral controller is designed for realizing the inertial control of reactive power. The small-signal model of the proposed VSCOM is built, and the design method of the control parameters is analyzed. Meanwhile, the inertial performance of the proposed VSCOM with different control parameters is analyzed from the unit-step response. In weak grid or multiple parallel devices, the proposed VSCOM is more stable than the typical STATCOM in direct reactive power control mode. Finally, experimental results validate the proposed control strategy and parameter design method.