YJYihang Jiang

Yihang Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yihang Jiang has a total of 101 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • AI-driven actuation-compatible tracking for closed-loop navigation of miniature robots in vivo

    by Delin Hu, Zhaoyang Qi, Yihang Jiang, Xurui Liu, Moqiu Zhang, Haojin Yang, Li Zhang

    Miniature wireless magnetic robots (MWMRs) hold immense potential for minimally invasive interventions. Real-time tracking of MWMRs is essential for precise in vivo navigation but remains challenging. Tracking MWMRs via their emitted magnetic signals offers a viable solution, yet it has been limited to centimeter-scale robots because isolating weak MWMR signals from overwhelming actuation-induced interference becomes increasingly difficult with miniaturization. Here, we present an artificial intelligence (AI)–driven tracking system to overcome these challenges, enabling precise localization of millimeter-scale MWMRs in the presence of actuation fields. Our approach integrates a sensor array design with a transformer to accurately model and filter the interference, followed by a spatiotemporal transformer that interprets the extracted MWMR signals over a short time window to corresponding three-dimensional coordinates. Our system has been validated in a range of in vitro and in vivo experiments, demonstrating its applicability to closed-loop navigation of MWMRs in unshielded clinical settings.

  • Top Cited Papers
    Open Access

    Modular magnetic microrobot system for robust endoluminal navigation and high–radial force stent delivery in complex ductal anatomy

    by Lin Su, Dongdong Jin, Neng Xia, Bo Hao, Yihang Jiang, Qinglong Wang, Haojin Yang, Xin Wang, Kai Fung Chan, Xing Ma, et al.

    Endoluminal stent implantation is a common intervention strategy for treating obstructive lesions, but conventional delivery systems struggle to reach deep, tortuous ducts. To overcome this limitation, we present a magnetically controlled microrobot that integrates two functional modules: a magnetic actuation (MA) module for agile navigation and an ultrasound-responsive self-expanding stent module (ST module) for lesion-specific dilation. The system uses a dynamically tunable assembly mechanism governed by rotational direction enabling integrated locomotion (clockwise) and on-demand module separation (counterclockwise) at stenotic sites. The platform is compatible with intraoperative ultrasound, allowing real-time navigation and thermally triggered expansion in physiological environments. By synergizing programmable magnetic actuation, ultrasound-mediated expansion, and clinical workflow compatibility, the robot can navigate tortuous phantom ducts, achieving controlled stent deployment within 3 seconds and complete expansion within 30 seconds, permitting minimally invasive treatment of biliary strictures. This work advances microrobotic stent delivery by overcoming key barriers to clinical translation in endoluminal interventions.


  • Top Cited Papers
    Open Access

    A magnetically actuated microcatheter with soft rotatable tip for enhanced endovascular access and treatment efficiency

    by Moqiu Zhang, Lidong Yang, Haojin Yang, Lin Su, Junnan Xue, Qinglong Wang, Bo Hao, Yihang Jiang, Kai Fung Chan, Joseph Jao Yiu Sung, et al.

    Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.


  • Open Access

    Magnetic Continuum Robot With Modular Axial Magnetization: Design, Modeling, Optimization, and Control

    by Yanfei Cao, Mingxue Cai, Bonan Sun, Zhaoyang Qi, Junnan Xue, Yihang Jiang, Bo Hao, Jiaqi Zhu, Xurui Liu, Chaoyu Yang, et al.

    Magnetic continuum robots (MCRs) have become popular owing to their inherent advantages of easy miniaturization without requiring complicated transmission structures. The evolution of MCRs, from initial designs with one embedded magnet to current designs with specific magnetization profile configurations (MPCs), has significantly enhanced their dexterity. While much progress has been achieved, the quantitative index-based evaluation of deformability for different MPCs, which can assist in designing MPCs with enhanced robot deformability, has not been addressed before. Here we use “deformability” to describe the capability for body deflection when an MCR forms different global shapes under an external magnetic field. Therefore, in this paper, we propose methodologies to design and control an MCR composed of modular axially magnetized segments. To guide robot MPC design, for the first time, we introduce a quantitative index-based evaluation strategy to analyze and optimize robot deformability. Additionally, a control framework with neural network-based controllers is developed to endow the robot with two control modes: the robot tip position and orientation ( $M_{1}$ ) and the global shape ( $M_{2}$ ). The excellent performance of the learnt controllers in terms of computation time and accuracy was validated via both simulation and experimental platforms. In the experimental results, the best closed-loop control performance metrics, indicated as the mean absolute errors, were 0.254 mm and 0.626 $^\circ$ for mode $M_{1}$ and 1.564 mm and 0.086 $^\circ$ for mode $M_{2}$ .


  • AIEgen Photosensitizer-Loaded Silica Nanoparticles for Lysosomes-Targeting Photodynamic Therapy in Tumor

    by Mingyan Zhao, Wenguang Zhang, Miaozhuang Fan, Zhourui Xu, Yihang Jiang, Zhengzheng Li, Peng Zhai, Xinmeng Zhang, Ting Chen, Yibin Zhang, et al.


  • Recent advances in nanotechnology approaches for non-viral gene therapy

    by Yihang Jiang, Miaozhuang Fan, Zhenxu Yang, Xiaochen Liu, Zhourui Xu, Shikang Liu, Gang Feng, Shuo Tang, Zhengzheng Li, Yibin Zhang, et al.

    Gene therapy has shown great potential in treating many diseases by downregulating the expression of certain genes. Various functional non-viral vectors have been well designed to enable efficient gene therapy.


  • Open Access

    Highly biocompatible chlorin e6-poly(dopamine) core–shell nanoparticles for enhanced cancer phototherapy

    by Shilin Chen, Yihang Jiang, Miaozhaung Fan, Xinmeng Zhang, Ying Zhang, Ting Chen, Chengbin Yang, Wing-Cheung Law, Zhourui Xu, Gaixia Xu

    Cancer is a life-threatening disease worldwide. Although several approaches, such as surgery, chemotherapy, and radiotherapy, have been proven effective for many patients in clinics, they usually suffer from drug resistance, severe toxic-side effects, patient discomfort, and sometimes, unsatisfactory efficacies. In recent years, phototherapy, as a less invasive but effective therapeutic method, has brought hope for cancer treatment. However, most reported photo-therapeutic agents are constructed using complex components with non-negligible toxicity risk, thus retarding the start of their clinical trials. To address this issue, herein, biocompatible photothermal/photodynamic dual-mode therapeutic nanoparticles (CBP NPs) were successfully designed and constructed based on the Food and Drug Administration (FDA)-approved ingredients, chlorin e6 (Ce6) and poly(dopamine) (PDA). Upon light irradiation, hyperthermia was induced and reactive oxygen species (ROS) were generated simultaneously by CBP NPs, contributing to synergistic phototherapy toward cancer. The in vitro and in vivo experiments have demonstrated well the antitumor effect of CBP NPs. More importantly, CBP NPs are completely harmless and degradable in vivo. Together, the CBP NPs developed by us are an ideal candidate for the enhanced phototherapy of tumors, which holds great potential for future clinical translation.


  • Open Access

    Fabry-Perot Interferometer Based on a Fiber-Tip Fixed-Supported Bridge for Fast Glucose Concentration Measurement

    by Shuo Tang, Mengqiang Zou, Cong Zhao, Yihang Jiang, Ribao Chen, Zhourui Xu, Chengbin Yang, Xiaomei Wang, Biqin Dong, Yiping Wang, et al.

    Blood glucose concentration is important for metabolic homeostasis in humans and animals. Many diabetic patients need to detect blood glucose daily which burdens community hospitals and family healthcare. Optical fiber sensors are widely used in biomedical detection because of their compact structure, fast response, high sensitivity, low cost, and ease of operation. In this work, we constructed a Fabry-Perot (FP) cavity biosensor for the fast detection of glucose concentration in serum. The femtosecond laser micromachining was applied to fabricate the FP cavity by printing the fiber-tip fixed-supported bridge at the end face of the optical fiber. An additional hemisphere was printed at the center of the outer surface of the bridge to avoid multi-beam interference. The results demonstrated that the proposed biosensor had high refractive index (RI) detection sensitivity, roughly 1039 nm/RIU at a wavelength of 1590 nm, and the detection sensitivity for glucose was around 0.185 nm/ (mg/mL) at a wavelength of 1590 nm. Due to its high sensitivity, compact structure, and fast response, the FP cavity biosensor has great potential to be applied in family healthcare for glucose concentration detection of diabetic patients.


  • Deep-Brain Three-Photon Imaging Enabled by Aggregation-Induced Emission Luminogens with Near-Infrared-III Excitation

    by Zhourui Xu, Zhijun Zhang, Xiangquan Deng, Jiangao Li, Yihang Jiang, Wing-Cheung Law, Chengbin Yang, Wanjian Zhang, Xiaolin Chen, Ke Wang, et al.

    Understanding the morphology and hemodynamics of cerebral vasculature at large penetration depths and microscale resolution is fundamentally important to decipher brain diseases. Among the various imaging technologies, three-photon (3P) microscopy is of significance by virtue of its deep-penetrating capability and submicron resolution, which especially benefits in vivo vascular imaging. Aggregation-induced emission luminogens (AIEgens) have been recognized to be extraordinarily powerful as 3P probes. However, systematic studies on the structure–performance relationship of 3P AIEgens have been seldom reported. Herein, a series of AIEgens has been designed and synthesized. By intentionally introducing benzene rings onto electron donors (D) and acceptors (A), the molecular distortion, conjugation strength, and the D–A relationship can be facilely manipulated. Upon encapsulation with DSPE-PEG2000, the optimized AIEgens are successfully applied for 3P microscopy with emission in the far-red/near-infrared-I (NIR-I, 700–950 nm) region under the near-infrared-III (NIR-III, 1600–1870 nm) excitation. Impressively, using mice with an opened skull, vasculature within 1700 μm and a microvessel with a diameter of 2.2 μm in deep mouse brain were clearly visualized. In addition, the hemodynamics of blood vessels were well-characterized. Thus, this work not only proposes a molecular design strategy of 3P AIEgens but also promotes the performance of 3P imaging in cerebral vasculature.


  • A biocompatible photosensitizer with a high intersystem crossing efficiency for precise two-photon photodynamic therapy

    by Zhourui Xu, Yihang Jiang, Yuanyuan Shen, Lele Tang, Zulu Hu, Guimiao Lin, Wing-Cheung Law, Mingze Ma, Biqin Dong, Ken-Tye Yong, et al.

    Photodynamic efficiency is strongly dependent on the generation rate of reactive oxygen species (ROS) and the tissue penetration depth. Recent advances in materials science reveal that organic molecules with room-temperature phosphorescence (RTP) can potentially serve as efficient photosensitizers owing to their limited dark cytotoxicity and abundant triplet excitons upon light irradiation. In this study, we combine RTP materials with two-photon excitation to improve the ROS generation, therapeutic precision, and tissue penetration of photodynamic therapy. We successfully prepared a novel RTP-based photosensitizer (BF2DCz) with a high photoluminescence quantum yield of 47.7 ± 3% and a remarkable intersystem crossing efficiency of ∼90.3%. By encapsulation into the bovine serum albumin (BSA) matrix, BF2DCz-BSA exhibits excellent biocompatibility, negligible dark toxicity, and superior photostability. Excitation using a femtosecond laser causes BF2DCz-BSA to efficiently generate ROS and precisely exert cell damage at the desired location.