HCHung-Wei Chiu

Hung-Wei Chiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hung-Wei Chiu has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Low-Noise Ultrafast-Transient-Response Low-Transient-Voltage Boost Converter for Sensitive Wireless Sensor Networks

    by Jiann-Jong Chen, Yuh-Shyan Hwang, Ching-Tui Chen, Hung-Wei Chiu

    A low-noise ultra-fast-transient-response low-transient-voltage boost converter with hysteresis-voltage-controlled and noise-shaping techniques for low-voltage solar cells in sensitive wireless sensor networks is presented. Using oversampling and noise shaping techniques to generate a variable switching frequency to break up the output noise and achieve low electromagnetic interference. However, due to the second-order delta-sigma modulation, the transient response is relatively slow. The hysteresis-voltage-controller (HVC) circuit then generates an upper and lower voltage VBH and VBL. If the voltage Vsense is less than the lower voltage VBL or the voltage Vsense is greater than the upper voltage VBH, the power transistors MN and MP are switched on to achieve transient response acceleration. The transient times are all 1.5μs at load current (IOUT) is varied between 10 mA and 100 mA, respectively, and the peak conversion efficiency is 88.3% at an output voltage (VOUT) of 1.8 V with an IOUT of 100mA.

  • An Ultrafast-Transient-Response Boost Converter With V-Cubed-Controlled Techniques Suitable for Low-Voltage Solar Cells in Wireless Sensor Networks

    by Jiann-Jong Chen, Yuh-Shyan Hwang, Guan-Zhi Lin, Hung-Wei Chiu

    This paper proposed a V-cubed adaptive-on-time controlled boost converter with zero-current-detection techniques suitable for low-voltage solar cells in wireless sensor networks. This converter employs V-cubed adaptive-on-time control and incorporates a zero-current detector to enhance efficiency under light loads. The design and implementation are carried out using the T18HVG2 (TSMC 0.18μm HV 1P6M) process, with a chip area of 1.067×1.073 mm2. The input voltage range is 0.5V-1.2V, the output voltage is 1.5V-2.0V, and the load current range is 10mA-150mA. The transient response times are 1μs and 0.8μs, achieving a peak efficiency of 94.2% at a load current of 130mA. The major contributions of this paper are: (1) we proposed a V-cubed adaptive-on-time controlled boost converter with zero-current-detection techniques; (2) the proposed converter has been simulated with SIMPLIS and HSPICE to verify the function well; (3) The performance of the proposed converter is better than others’ work. In a DC-DC boost converter, a voltage cubed control strategy is used, which usually means adjusting the control parameters in the control loop according to the cube of the output voltage. The application of this method can bring some advantages, which are mainly reflected in the following aspects: (1) Improved efficiency; (2) Improved dynamic response; (3) Reduced control noise and oscillation; (4) Improved load regulation; (5) Extended component life; In summary, the application of voltage cubic control in DC-DC boost converters can improve efficiency, stability and dynamic response, giving it obvious advantages in applications requiring high performance and high stability.


  • Open Access

    A Low-Noise Current-Squared Delta-Sigma-Modulation Boost Converter Suitable for Low-Voltage Wireless Sensor Networks With Transient-Accelerated Techniques

    by Jiann-Jong Chen, Yuh-Shyan Hwang, Hung-Wei Chiu, Yu-Zhe Gao, Joshua Ku

    This paper presents a low-noise current-squared delta-sigma-modulation boost converter suitable for low-voltage wireless sensor networks with transient-accelerated techniques. There are two current-controlled loops and two voltage-controlled loops in the proposed converter to achieve low noise, fast-transient-response times, and low-transient voltages. The converter’s transient-accelerated circuit consists of a current sensing circuit and a dynamic slope compensation circuit, which significantly improves the transient response. Additionally, the converter has low output noise and a fast-transient recovery time, and exhibits good undershoot and overshoot voltage control ability when the load current changes. Experimental results indicate that the boost converter is fabricated using the TSMC T18HVG2 1P6M CMOS process with a chip area of 1.26 mm × 1.18 mm. The sampling frequency of 10 MHz, and the output-to-noise ratio (ONR) is 70.4dB. Furthermore, the converter achieves a peak power efficiency of 88 %, with optimal performance achieved at a load current of 70 mA and an output voltage of 1.8 V.


  • Open Access

    A New Low-Noise I-Squared Buck Converter Suitable for Wireless Sensor Networks With Dual-Current-Acceleration Techniques

    by Jiann-Jong Chen, Yuh-Shyan Hwang, Hung-Wei Chiu, Ming-Dao Luo, Chien-Hung Lai, Joshua Ku

    This paper proposed a new low-noise I-squard 2 nd -order continuous-time-delta-sigma-modulation (CT-DSM) buck converter suitable for wireless sensor networks with dual-current-acceleration (DCA) techniques. First, it adopts the second-order CT-DSM scheme, which can effectively utilize the oversampling and the noise shaping techniques to disperse the noise and push it to higher frequencies. Second, the use of the pseudo-inductor-current-sensor can increase the bandwidth of the closed-loop gain and consequently speeds up the transient response of the converter. Third, the dynamic-current regulator utilizes the principle of current charging and discharging to make the converter respond faster when the load changes dynamically. Fourth, this paper combines the pseudo-inductor-current-sensor and the dynamic-current regulator to realize the dual-current-acceleration technique, which can accelerate the transient response by up to 45.5%. The proposed converter is designed and fabricated in TSMC 0.18μm 1P6M CMOS process, and the chip area is 1.065 mm 2 . When the load current changes from 50mA to 500mA and 500mA to 50mA, the transient responses are 2.4μs and 3μs, respectively, and the peak efficiency is 92.4%. The measurement result of ONR is 78.087dB, with the sampling frequency of 10 MHz.


  • CMOS Monolithic Thermostatic Microwave Heater With Bioimpedance Load Effect Compensation

    by Shao-Jyun Lin, Hsiao-Chin Chen, Hung-Wei Chiu

    Based on microwave heating, a monolithic low-power temperature-programmable high-precision microheater is implemented for thermotherapy. The microwave heater is designed and fabricated in 0.18- $\mu$ m CMOS process. The $Q$ -factor of the on-chip inductor that serves as the heat applicator would be degraded by the bioimpedance load effect when the heating target is in the vicinity of the microwave heater. Because of such bioimpedance load effect, the electric field around the heat applicator is decreased, which limits the heating efficiency of the microwave heater. To improve the heating efficiency, a bioimpedance load effect compensation technique is adopted to enhance the electric field around the heat applicator. Moreover, a time-to-digital converter (TDC)-based temperature sensor with a sensing resolution of 0.052 is employed to realize the thermostatic function with the precision of $\pm$ 0.1 $^{\circ}$ C. Consuming 136 mW, the power amplifier of the heater delivers the output power of 25.36 mW (14 dBm). The heating rate of 0.24 $^{\circ}$ C/min and heating efficiency of 34.4 J/ $^{\circ}$ C are achieved.


  • A Dual-Mode Multifunctional Pulsed Radio-Frequency Stimulator for Trigeminal Neuralgia Relief and its Animal Model

    by Kun-Ying Yeh, Hung-Wei Chiu, Wan-Ting Tseng, Hsiao-Chin Chen, Chen-Tung Yen, Shey-Shi Lu, Mu-Lien Lin

    This work proposed a programmable pulsed radio-frequency (PRF) stimulator for trigeminal neuralgia (TN) relief on demand. The implantable stimulator is a miniaturized micro-system which integrates a wireless interface circuit, a sensor interface circuit, a PRF pattern generation circuit and a logic controller. The multifunctional stimulator capable of delivering current/voltage stimulation provides the choice of the biphasic sinusoidal, square and patterned waveform for PRF treatment researches. The external handheld device can wirelessly transmit the parameters of frequency, amplitude, pulse duration and repetition rate of the pulse train to the implanted stimulator. While stimulating, the temperature sensor can monitor the operating temperature. The feedback signal is transmitted in medical implanted communication system (MICS). The micro-system is fabricated in a 0.35 μm CMOS process with a chip size of 3.1 × 2.7 mm 2 . The fabricated chip was mounted on a 2.6 × 2.1 cm 2 test board for studying the in vivo efficacy of pain relief by PRF. Animal studies of PRF stimulation and commonly-used medication for trigeminal neuralgia are also demonstrated and the presented results prove that PRF stimulation has greater effectiveness on trigeminal neuralgia relief comparing to the medication. The effectiveness period lasts at least 14 days. The results of neural recording show that the PRF stimulation of trigeminal ganglion (TG) attenuated neuron activities without being severely damaged. Pathology also revealed no lesion found on the stimulated area.


  • Monolithic CMOS Microwave Heater With Programmable Thermostat Function for Thermotherapy

    by Tzu-Yu Tseng, Hsiao-Chin Chen, Hung-Wei Chiu

    A monolithic microwave heater with programmable thermostat function is implemented for thermotherapy. To achieve microwave heating, the heater adopts a 2.4-GHz oscillator to generate the microwave and uses an amplifier with LC resonance load to enhance the signal strength. Consuming the power of 113.0 mW, the amplifier delivers the power of 13.2 dBm. The microwave heater is integrated with temperature sensors, an 11-bit SAR-ADC and a comparator to achieve the programmable thermostat function. For 3-mm thick agar phantoms, the heating rate is around 0.16 ∘C/min. The heater successively achieves the programmed temperature increases of 1.5, 3.0 and 4.5 ∘C, with the standard deviation < 0.19 ∘C under the thermostat condition.


  • A Dual-Mode Highly Efficient Class-E Stimulator Controlled by a Low-Q Class-E Power Amplifier Through Duty Cycle

    by Hung-Wei Chiu, Chien-Chi Lu, Jia-Min Chuang, Wei-Tso Lin, Chii-Wann Lin, Ming-Chien Kao, Mu-Lien Lin

    This paper presents the design flow of two high-efficiency class-E amplifiers for the implantable electrical stimulation system. The implantable stimulator is a high-Q class-E driver that delivers a sine-wave pulsed radiofrequency (PRF) stimulation, which was verified to have a superior efficacy in pain relief to a square wave. The proposed duty-cycle-controlled class-E PRF driver designed with a high-Q factor has two operational modes that are able to achieve 100% DC-AC conversion, and involves only one switched series inductor and an unchanged parallel capacitor. The measured output amplitude under low-voltage (LV) mode using a 22% duty cycle was 0.98 V with 91% efficiency, and under high-voltage (HV) mode using a 47% duty cycle was 2.95 V with 92% efficiency. These modes were inductively controlled by a duty-cycle detector, which can detect the duty-cycle modulated signal generated from the external complementary low-Q class-E power amplifier (PA). The design methodology of the low-Q inductive interface for a non-50% duty cycle is presented. The experimental results exhibits that the 1.5-V PA that consumes DC power of 14.21 mW was able to deliver a 2.9-V sine wave to a 500 Ω load. The optimal 60% drain efficiency of the system from the PA to the load was obtained at a 10-mm coupling distance.


  • In Situ Measurement of Tissue Impedance Using an Inductive Coupling Interface Circuit

    by Hung-Wei Chiu, Jia-Min Chuang, Chien-Chi Lu, Wei-Tso Lin, Chii-Wann Lin, Mu-Lien Lin

    In this work, a method of an inductive coupling impedance measurement (ICIM) is proposed for measuring the nerve impedance of a dorsal root ganglion (DRG) under PRF stimulation. ICIM provides a contactless interface for measuring the reflected impedance by an impedance analyzer with a low excitation voltage of 7 mV. The paper develops a calibration procedure involving a 50-Ω reference resistor to calibrate the reflected resistance for measuring resistance of the nerve in the test. A de-embedding technique to build the equivalent transformer circuit model for the ICIM circuit is also presented. A batteryless PRF stimulator with ICIM circuit demonstrated good accuracy for the acute measurement of DRG impedance both in situ and in vivo. Besides, an in vivo animal experiment was conducted to show that the effectiveness of pulsed radiofrequency (PRF) stimulation in relieving pain gradually declined as the impedance of the stimulated nerve increased. The experiment also revealed that the excitation voltage for measuring impedance below 25 mV can prevent the excitation of a nonlinear response of DRG.


  • A 2.1 to 6 GHz Tunable-band LNA With Adaptive Frequency Responses by Transistor Size Scaling

    by Yu-Hsiang Wang, Kuan-Ting Lin, Tao Wang, Hung-Wei Chiu, Hsiao-Chin Chen, Shey-Shi Lu

    A 2.1 to 6 GHz tunable-band LNA by using transistor-size scaling technique is realized in 90 nm CMOS technology, which adopts a scalable-size transistor mimicked by the parallel-connected transistors with binary weighted device sizes. In the 16 programmable bands located in the frequencies of interest, the S21 varies in the range from 15.1 to 16.9 dB, and the NF is from 2.16 to 2.81 dB. This tunable -band LNA occupies only 0.23 mm2, which is readily compact compared with the prior arts of passive components switchable LNAs.