    Strength Characteristics and Microstructure of Cement Stabilized Soft Soil Admixed with Silica Fume

    by Nan Jiang, Changming Wang, Zeping Wang, Bailong Li, Yi-Ao Liu

    Soft soil improvement is an important subject in civil engineering, and searching for an effective admixture is an important research. Silica fume (SF) is a kind of recycled material, it can be used in engineering as a pozzolanic material. The main objective of this study is to assess the effectiveness of industrial waste silica fume (SF) as an admixture to improve the cement stabilized soft soil. The unconfined compressive test (UCT) and scanning electron microscopy (SEM) test of cement stabilized soil with different SF contents and different curing times have been carried out. UCT after 28 days revealed that the addition of SF can effectively increase the strength of cement stabilized soil and reduce the amount of cement, and 1.5% SF content is considered optimum, excessive SF will not further increase the strength. SF helped to accelerate the cement hydration reaction and significantly improve the early-age strength of stabilized soil even at 3 days, which can improve construction efficiency in actual projects. SEM analyses shows that the proper SF content could make the hydration product calcium silicate hydrate gel (CSH) fill the pores and increase the strength of the material, but excessive SF will increase the large pores content of the material and reduce the strength. This provided a basis for application of SF in improving soft soil.


  • Open Access

    Determination of Embedded Depth of Soldier Piles in Pile-Anchor Supporting System in Granite Residual Soil Area

    by Yiao Liu, Changming Wang, Xiaoyang Liu, Ruiyuan Gao, Bailong Li, Kaleem Ullah Jan Khan

    Reasonable depth of pile embedment is one of the key factors for the success of deep foundation pit projects. This paper has taken a deep foundation pit project in a granite residual soil area in Shenzhen as an example and used physical model tests to study the deformation law of the piles and the surrounding soil during the excavation of the deep foundation pit, revealing the variation law of earth pressure in time and space in the pit and then verified it by numerical simulation. The influence of the embedded depth of the pile on the deformation and earth pressure of the deep foundation pit is then explicitly discussed. The study shows that the embedded depth has a significant effect on the deformation and earth pressure distribution of the foundation pit. The earth pressure in front of the pile tends to approach the passive earth pressure as the embedment depth decreases, while the earth pressure behind the pile is in between the Rankine active earth pressure and the static soil pressure; the settlement value and settlement range of the surrounding soil are doubled. The pile displacement increases as the maximum displacement point rises. The maximum displacement of the pile body was used as the basis for determining the instability of the foundation pit. The optimum embedded depth is obtained when the depth of embedment of the pile is 0.22 H (H is the excavation depth of the foundation pit).


  • Open Access

    Dynamic Response Analysis of Retaining Dam under the Impact of Solid-Liquid Two-Phase Debris Flow Based on the Coupled SPH-DEM-FEM Method

    by Bailong Li, Changming Wang, Yanying Li, Yiao Liu, Nan Jiang, Zhu Liang, Kaleem Ullah Jan Khan

    Based on the coupled SPH-DEM-FEM numerical method, this paper analyzes the dynamic interaction of solid debris flow particle-liquid debris flow slurry-retaining dam in order to explore the dynamic response of retaining dam under the impact of the solid-liquid two-phase debris flow and delves into the process of the debris flow impact on the dam, the impact force of debris flow, and the elastic-plastic time-history characteristics of the dam under different slopes of trapezoidal grooves. The calculation results show that the coupled SPH-DEM-FEM method can vividly simulate the impact behavior of the solid-liquid two-phase debris flow on the dam, reproduce the impact, climbing, and siltation in the process of the debris flow impact; the dynamic time-history curve of the retaining dam is consistent with the law of the literature, and the result of the debris flow impact force obtained is close to that of the empirical formula. Moreover, this paper studies the impact force distribution of the debris flow impact process. The results have a certain reference value for the study of the dynamic response of the retaining dam under the impact of the solid-liquid two-phase debris flow and the engineering design of the debris flow-retaining dam.


  • Open Access

    Experimental Study for the Embedded Depth of Support Structure Foundation Pit in Granite Residual Soil Area

    by Yi-Ao Liu, Chang-Ming Wang, Rui-Yuan Gao, Bai-Long Li, Xiao-Yang Liu, Zhu Liang, Nan Jiang, Zhi-Dong Chen

    In order to deeply understand the appropriate embedded depth of the foundation pit diaphragm wall in granite residual soil area, a physical model of the diaphragm wall with inner support for foundation excavation was constructed according to the actual project in the proportion of 1 : 30. The distribution of Earth pressure, the horizontal displacement of the wall, and the settlement behind the wall were obtained by physical experiments. The numerical simulation was then performed to authenticate the results from physical modeling. It was observed that the embedded depth of the diaphragm wall had the most obvious influence on the horizontal displacement of the wall. Moreover, the final soil settlement and its influence were significantly increased with the decrease in embedded depth. The analysis results also suggested that the control value for the embedded depth of the wall should not be less than 0.36 H (H is the excavation depth of the foundation pit).