Katharina Giannis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katharina Giannis has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Georg D. Strbac
Clinical Division of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
10 shared publications - Michael Hans Bertl
Division of Orthodontics, School of Dentistry, Medical University of Vienna, Vienna, Austria
4 shared publications Christian Ulm
Division of Oral Surgery, (Head: C. Ulm, PhD), School of Dentistry, Medical University of Vienna, Sensengasse 2a, A-1090 Vienna, Austria
3 shared publicationsMartina Mittlböck
Section for Clinical Biometrics, Center for Medical Statistics, Informatics and Intelligent Systems, (Head: G. Heinze, PhD), Medical University of Vienna, Spitalgasse 23, A-1090 Vienna, Austria
3 shared publicationsWerner Zechner
Division of Oral Surgery, (Head: C. Ulm, PhD), School of Dentistry, Medical University of Vienna, Sensengasse 2a, A-1090 Vienna, Austria
3 shared publicationsAndrea Foltin
Resident, Division of Orthodontics, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria
2 shared publications
Latest Publications
- 11 November 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (1) , 152-165
Drilling‐ and withdrawing‐related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone
Introduction: Excessive surgical trauma is believed to be among the most important causes for early implant losses. As thermal injury to the bone is not only dependent on the amount of generated heat but also on the tissue exposure time, and the greatest temperature increase was found within the withdrawing period, the entire osteotomy procedure with the parameters contributing to thermal damage is of particular clinical relevance. The aim of this study was to investigate the thermal performance of metal‐based and ceramic implant drills regarding the temperature exposure time during the whole osteotomy process.Materials and Methods: This investigation consisted of 240 individual preparations in total, comprising two different drilling depths (10 and 16 mm), two irrigation methods (external and without irrigation), two implant drill materials (stainless steel and zirconia), and three consecutive drill diameters per material (2.0/2.2, 2.8, and 3.5 mm) with 10 identical repetitions. Real‐time multichannel temperature measurement was conducted during automated drilling procedures in standardized bovine bone specimens.Results: The maximum temperature changes were highly associated with the time period of passive drill withdrawing (p ≤ 0.05), irrespective of drill material, drilling depth, or drill diameter. Statistically significant differences in temperature generation between stainless steel and ceramic drills were observed in irrigated testing sites at both drilling depths with smaller drill diameters (2.0/2.2 and 2.8 mm, p ≤ 0.05).Conclusion: Results of this in vitro study could demonstrate a strong association between the highest temperature increase and the passive withdrawing time period in both investigated drill materials. Considering these findings and the resulting thermal bone damage due to the whole surgical procedure, high overall temperatures in combination with a prolonged heat exposure time may impact the future osseointegration process.
- 11 November 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (1) , 152-165
Drilling‐ and withdrawing‐related thermal effects of implant site preparation for ceramic and stainless steel twist drills in standardized bovine bone
Introduction: Excessive surgical trauma is believed to be among the most important causes for early implant losses. As thermal injury to the bone is not only dependent on the amount of generated heat but also on the tissue exposure time, and the greatest temperature increase was found within the withdrawing period, the entire osteotomy procedure with the parameters contributing to thermal damage is of particular clinical relevance. The aim of this study was to investigate the thermal performance of metal‐based and ceramic implant drills regarding the temperature exposure time during the whole osteotomy process.Materials and Methods: This investigation consisted of 240 individual preparations in total, comprising two different drilling depths (10 and 16 mm), two irrigation methods (external and without irrigation), two implant drill materials (stainless steel and zirconia), and three consecutive drill diameters per material (2.0/2.2, 2.8, and 3.5 mm) with 10 identical repetitions. Real‐time multichannel temperature measurement was conducted during automated drilling procedures in standardized bovine bone specimens.Results: The maximum temperature changes were highly associated with the time period of passive drill withdrawing (p ≤ 0.05), irrespective of drill material, drilling depth, or drill diameter. Statistically significant differences in temperature generation between stainless steel and ceramic drills were observed in irrigated testing sites at both drilling depths with smaller drill diameters (2.0/2.2 and 2.8 mm, p ≤ 0.05).Conclusion: Results of this in vitro study could demonstrate a strong association between the highest temperature increase and the passive withdrawing time period in both investigated drill materials. Considering these findings and the resulting thermal bone damage due to the whole surgical procedure, high overall temperatures in combination with a prolonged heat exposure time may impact the future osseointegration process.
- Open Access
- 21 November 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 32 (2) , 154-166
Thermal effects of various drill materials during implant site preparation—Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model
Objectives: The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model.Material and Methods: A total of 320 automated intermittent osteotomies of 10‐ and 16‐mm drilling depths were performed using zirconium dioxide‐based and stainless steel drills. Various drill diameters (2.0/ 2.2, 2.8, 3.5, 4.2 mm ∅) and different cooling methods (without/ with external saline irrigation) were investigated at room temperature (21 ± 1°C). Temperature changes were recorded in real time using two custom‐built multichannel thermoprobes in 1‐ and 2‐mm distance to the osteotomy site. For comparisons, a linear mixed model was estimated.Results: Comparing thermal effects, significantly lower temperatures could be detected with steel‐based drills in various drill diameters, regardless of drilling depth or irrigation method. Recorded temperatures for metal drills of all diameters and drilling depths using external irrigation were below the defined critical temperature threshold of 47°C, whereas ceramic drills of smaller diameters reached or exceeded the harmful temperature threshold at 16‐mm drilling depths, regardless of whether irrigation was applied or not. The results of this study suggest that the highest temperature changes were not found at the deepest point of the osteotomy site but were observed at subcortical and deeper layers of bone, depending on drill material, drill diameter, drilling depth and irrigation method.Conclusions: This standardised investigation revealed drill material and geometry to have a substantial impact on heat generation, as well as external irrigation, drilling depth and drill diameter.
- 21 November 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 32 (2) , 154-166
Open AccessThermal effects of various drill materials during implant site preparation—Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model
Objectives: The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model.Material and Methods: A total of 320 automated intermittent osteotomies of 10‐ and 16‐mm drilling depths were performed using zirconium dioxide‐based and stainless steel drills. Various drill diameters (2.0/ 2.2, 2.8, 3.5, 4.2 mm ∅) and different cooling methods (without/ with external saline irrigation) were investigated at room temperature (21 ± 1°C). Temperature changes were recorded in real time using two custom‐built multichannel thermoprobes in 1‐ and 2‐mm distance to the osteotomy site. For comparisons, a linear mixed model was estimated.Results: Comparing thermal effects, significantly lower temperatures could be detected with steel‐based drills in various drill diameters, regardless of drilling depth or irrigation method. Recorded temperatures for metal drills of all diameters and drilling depths using external irrigation were below the defined critical temperature threshold of 47°C, whereas ceramic drills of smaller diameters reached or exceeded the harmful temperature threshold at 16‐mm drilling depths, regardless of whether irrigation was applied or not. The results of this study suggest that the highest temperature changes were not found at the deepest point of the osteotomy site but were observed at subcortical and deeper layers of bone, depending on drill material, drill diameter, drilling depth and irrigation method.Conclusions: This standardised investigation revealed drill material and geometry to have a substantial impact on heat generation, as well as external irrigation, drilling depth and drill diameter.
- 1 November 2018
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 88 (6) , 719-725
Association between maxillary lateral incisors' root volume and palatally displaced canines: An instrumental variables approach to the guidance theory
Objectives: To evaluate association and causation between maxillary lateral incisors' (MxI2) apical root volume (ARV) and palatally displaced canines (PDC). Materials and Methods: In a retrospective cross-sectional study, computed tomography scans of 179 patients with unilateral PDC were analyzed. MxI2 root length and volume on the impaction and eruption side were measured. A mixed logit model was used to infer the association between ARV and PDC and an instrumental variables approach to interpret causality. Results: MxI2 root length on the impaction side was shorter in 42%, equal in 33% and longer in 25% of the patients. ARV amounted for 13.5% of total root volume on the impaction and 14.9% on the eruption side. Reduced ARV was significantly associated with the impaction side ( P < .001). The causal effect of ARV on PDC in the instrumental variable approach amounted to less than half of the association in a standard noncausal approach. Conclusions: An association between PDC and reduced MxI2 root length and volume was confirmed. However, the lack of causality did not allow the researchers to draw a conclusion as to whether a reduced ARV is causing PDC or resulting from it; this should be considered in etiologic theories.
- 1 November 2018
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 88 (6) , 719-725
Association between maxillary lateral incisors' root volume and palatally displaced canines: An instrumental variables approach to the guidance theory
Objectives: To evaluate association and causation between maxillary lateral incisors' (MxI2) apical root volume (ARV) and palatally displaced canines (PDC). Materials and Methods: In a retrospective cross-sectional study, computed tomography scans of 179 patients with unilateral PDC were analyzed. MxI2 root length and volume on the impaction and eruption side were measured. A mixed logit model was used to infer the association between ARV and PDC and an instrumental variables approach to interpret causality. Results: MxI2 root length on the impaction side was shorter in 42%, equal in 33% and longer in 25% of the patients. ARV amounted for 13.5% of total root volume on the impaction and 14.9% on the eruption side. Reduced ARV was significantly associated with the impaction side ( P < .001). The causal effect of ARV on PDC in the instrumental variable approach amounted to less than half of the association in a standard noncausal approach. Conclusions: An association between PDC and reduced MxI2 root length and volume was confirmed. However, the lack of causality did not allow the researchers to draw a conclusion as to whether a reduced ARV is causing PDC or resulting from it; this should be considered in etiologic theories.
- 26 September 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (8) , 2959
Reply to: letter to the editor about the article published in Clinical Oral Investigations tilted: impacted and transmigrated mandibular canines: an analysis of 3D radiographic imaging data (Bertl MH, Frey C, Bertl K, Giannis K, Gahleitner A, Strbac GD (2018) Clin Oral Investig, doi: 10.1007/s00784-018-2342-0
- 26 September 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (8) , 2959
Reply to: letter to the editor about the article published in Clinical Oral Investigations tilted: impacted and transmigrated mandibular canines: an analysis of 3D radiographic imaging data (Bertl MH, Frey C, Bertl K, Giannis K, Gahleitner A, Strbac GD (2018) Clin Oral Investig, doi: 10.1007/s00784-018-2342-0
- 1 February 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (6) , 2389-2399
Impacted and transmigrated mandibular canines: an analysis of 3D radiographic imaging data
Impacted and transmigrated mandibular canines differ greatly in incidence, etiopathology, associated anomalies, and treatment prospects, when compared to their maxillary counterparts. The aim of this study was to provide a detailed analysis of 3D radiographic imaging data of impacted mandibular canines.
- 1 February 2018
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 22 (6) , 2389-2399
Impacted and transmigrated mandibular canines: an analysis of 3D radiographic imaging data
Impacted and transmigrated mandibular canines differ greatly in incidence, etiopathology, associated anomalies, and treatment prospects, when compared to their maxillary counterparts. The aim of this study was to provide a detailed analysis of 3D radiographic imaging data of impacted mandibular canines.
- 1 August 2017
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 45 (8) , 1143-1149
Survival rate of autotransplanted teeth after 5 years – A retrospective cohort study
- 1 August 2017
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 45 (8) , 1143-1149
Survival rate of autotransplanted teeth after 5 years – A retrospective cohort study
- Top Cited Papers
- 1 March 2017
- Published by Elsevier in Journal of Endodontics
- Vol. 43 (3) , 496-501
Guided Modern Endodontic Surgery: A Novel Approach for Guided Osteotomy and Root Resection
- 1 March 2017
- Published by Elsevier in Journal of Endodontics
- Vol. 43 (3) , 496-501
Top Cited PapersGuided Modern Endodontic Surgery: A Novel Approach for Guided Osteotomy and Root Resection
- 1 December 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (12) , 1844-1850
Guided Autotransplantation of Teeth: A Novel Method Using Virtually Planned 3-dimensional Templates
- 1 December 2016
- Published by Elsevier in Journal of Endodontics
- Vol. 42 (12) , 1844-1850
Guided Autotransplantation of Teeth: A Novel Method Using Virtually Planned 3-dimensional Templates
- 1 July 2016
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 44 (7) , 843-847
Influence of repeat surgery on treatment time in the interdisciplinary management of impacted maxillary canines: A retrospective cohort study
- 1 July 2016
- Published by Elsevier in Journal of Cranio-Maxillofacial Surgery
- Vol. 44 (7) , 843-847
Influence of repeat surgery on treatment time in the interdisciplinary management of impacted maxillary canines: A retrospective cohort study
- 28 May 2013
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 17 (1) , 32-43
Drilling- and Withdrawing-Related Thermal Changes during Implant Site Osteotomies
Background Intrabony temperature increase is not only dependent on shearing energy and mechanical friction between bone and surgical drill but is also related to heat capacity and thermal conductivity of the surrounding bone and the applied surgical instrument. Thus time of occurrence of the highest temperature rise can be expected after the shearing process of the osteotomy, potentially affecting the process of osseointegration. Purpose The aim of this study was to evaluate temperature changes during the shearing and withdrawing processes during osteotomies. Materials and Methods An overall 160 automated intermittent osteotomies (10/16 mm drilling depth) with 2 mm diameter twist drills and 3.5 mm diameter conical drills and different irrigation methods (without/external/internal/combined) were performed on standardized bone specimens. The drilling cycles were operated by a computer-controlled surgical system, while a linear motion potentiometer and multichannel temperature sensors in various intrabony levels ensured the real-time documentation of temperature changes during the shearing and withdrawing processes. Results The highest temperature changes were invariably recorded during the process of withdrawal. Significantly lower temperature changes (p < .02) could be recorded at maximum drilling depths during the shearing process regardless of drilling depth, diameter or irrigation method. During coolant supply, 2 mm diameter twist drills showed higher temperatures (10 mm, p < .01/16 mm, p < .03) compared with 3.5 mm diameter conical implant drills. Internal (10 mm, p < .01) or combined irrigation (16 mm, p < .01) was associated with significantly lower temperatures compared with external irrigation by the use of conical implant drills. Conclusions Considering that heat generation during osteotomies is a multifactorial scenario, this study could demonstrate that the highest temperature rise during implant osteotomies occurs during the withdrawing process and that the time of occurrence is influenced by predominant factors such as osteotomy depth and mode of irrigation.
- 28 May 2013
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 17 (1) , 32-43
Drilling- and Withdrawing-Related Thermal Changes during Implant Site Osteotomies
Background Intrabony temperature increase is not only dependent on shearing energy and mechanical friction between bone and surgical drill but is also related to heat capacity and thermal conductivity of the surrounding bone and the applied surgical instrument. Thus time of occurrence of the highest temperature rise can be expected after the shearing process of the osteotomy, potentially affecting the process of osseointegration. Purpose The aim of this study was to evaluate temperature changes during the shearing and withdrawing processes during osteotomies. Materials and Methods An overall 160 automated intermittent osteotomies (10/16 mm drilling depth) with 2 mm diameter twist drills and 3.5 mm diameter conical drills and different irrigation methods (without/external/internal/combined) were performed on standardized bone specimens. The drilling cycles were operated by a computer-controlled surgical system, while a linear motion potentiometer and multichannel temperature sensors in various intrabony levels ensured the real-time documentation of temperature changes during the shearing and withdrawing processes. Results The highest temperature changes were invariably recorded during the process of withdrawal. Significantly lower temperature changes (p < .02) could be recorded at maximum drilling depths during the shearing process regardless of drilling depth, diameter or irrigation method. During coolant supply, 2 mm diameter twist drills showed higher temperatures (10 mm, p < .01/16 mm, p < .03) compared with 3.5 mm diameter conical implant drills. Internal (10 mm, p < .01) or combined irrigation (16 mm, p < .01) was associated with significantly lower temperatures compared with external irrigation by the use of conical implant drills. Conclusions Considering that heat generation during osteotomies is a multifactorial scenario, this study could demonstrate that the highest temperature rise during implant osteotomies occurs during the withdrawing process and that the time of occurrence is influenced by predominant factors such as osteotomy depth and mode of irrigation.