Dinesh Varma Tekumalla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dinesh Varma Tekumalla has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Deepak Pullaguram
Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India
2 shared publications Prabodh Bajpai
2 shared publications- Arghya Mallick
Delft Center for Systems and Control, TU Delft, Delft, The Netherlands
1 shared publication - Ashish Ranjan Hota
Department of Electrical Engineering, IIT Kharagpur, Kharagpur, India
1 shared publication Deepak Reddy Pullaguram
1 shared publicationDiptendu Pal
Department of Electrical Engineering Indian Institute of Technology Kharagpur Kharagpur West Bengal India
1 shared publication
Latest Publications
- Open Access
- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Adaptive Conformal Constraint Tightening for Distribution-Shift-Resilient Volt--VAR Optimization in PV-Rich Distribution Networks
Chance-constrained voltage control typically relies on uncertainty models calibrated offline, which can become unreliable under changing photovoltaic (PV) forecast-error regimes. This paper proposes adaptive conformal constraint tightening (ACCT), where the voltage margin is defined as $\delta_t=\theta_t\hat{\sigma}(a_t)$. The dimensionless state $\theta_t$ is updated online from measured voltage violations only when constraints are active, while $\hat{\sigma}(a_t)$ is learned from residuals of the exact AC power-flow solution, thereby absorbing linearization error. Three analytical results are established: (i) a distribution-free bound showing that the violation frequency over active-constraint intervals is at most $\alpha+(D+\gamma)/(\gamma N_T)$ for any bounded uncertainty sequence; (ii) a tracking bound yielding the step-size rule $\gamma^\star=(2\varsigma^2/\mu)^{1/3}$; and (iii) proof that the tightened-LP optimal cost is convex, piecewise linear, non-decreasing, and Lipschitz in the margin, with slope determined by voltage-constraint dual variables. On the IEEE 33-bus feeder, static conformal margins produce approximately 10% post-shift violations against a 5% target, whereas ACCT limits them to 4.5% and reduces curtailment by 31% in the calibrated regime. Similar behavior is observed on the IEEE 123-node feeder, where ACCT achieves 4.0% post-shift violations and remains near target for shifts up to $3.5\times$. With unbalanced three-phase OpenDSS ground truth and a balanced optimization model, ACCT maintains 4.1% violations versus 17--47% for deterministic, Gaussian, and static-conformal controllers. ACCT therefore provides automatic online calibration with finite-sample guarantees under distribution shift and model mismatch.- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAdaptive Conformal Constraint Tightening for Distribution-Shift-Resilient Volt--VAR Optimization in PV-Rich Distribution Networks
Chance-constrained voltage control typically relies on uncertainty models calibrated offline, which can become unreliable under changing photovoltaic (PV) forecast-error regimes. This paper proposes adaptive conformal constraint tightening (ACCT), where the voltage margin is defined as $\delta_t=\theta_t\hat{\sigma}(a_t)$. The dimensionless state $\theta_t$ is updated online from measured voltage violations only when constraints are active, while $\hat{\sigma}(a_t)$ is learned from residuals of the exact AC power-flow solution, thereby absorbing linearization error. Three analytical results are established: (i) a distribution-free bound showing that the violation frequency over active-constraint intervals is at most $\alpha+(D+\gamma)/(\gamma N_T)$ for any bounded uncertainty sequence; (ii) a tracking bound yielding the step-size rule $\gamma^\star=(2\varsigma^2/\mu)^{1/3}$; and (iii) proof that the tightened-LP optimal cost is convex, piecewise linear, non-decreasing, and Lipschitz in the margin, with slope determined by voltage-constraint dual variables. On the IEEE 33-bus feeder, static conformal margins produce approximately 10% post-shift violations against a 5% target, whereas ACCT limits them to 4.5% and reduces curtailment by 31% in the calibrated regime. Similar behavior is observed on the IEEE 123-node feeder, where ACCT achieves 4.0% post-shift violations and remains near target for shifts up to $3.5\times$. With unbalanced three-phase OpenDSS ground truth and a balanced optimization model, ACCT maintains 4.1% violations versus 17--47% for deterministic, Gaussian, and static-conformal controllers. ACCT therefore provides automatic online calibration with finite-sample guarantees under distribution shift and model mismatch. - Open Access
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
A Model-Predictive Smart Energy Management System for Grid-Connected PV–Battery Microgrids with Hardware-in-the-Loop Validation
Smart energy management systems (SEMS) are increasingly used to coordinate photovoltaic (PV) generation, battery energy storage, and flexible loads in grid-connected and islandable microgrids. However, most reported SEMS are validated only through software simulations, leaving controller timing, converter nonlinearities, and communication delays largely unverified. This paper presents a hierarchical SEMS combining a receding-horizon model predictive control (MPC) secondary/tertiary economic dispatch layer with a primary droop-controlled inverter layer. The control problem is formulated as a convex quadratic program (QP) incorporating battery state-of-charge (SOC) dynamics, inverter power constraints, and a coincident-peak-aware cost objective. First-order optimality (KKT) conditions provide a shadow-price interpretation of battery dispatch, while recursive feasibility, input-to-state stability, and small-signal analysis establish closed-loop stability and exponential elimination of droop-induced steady-state error. The proposed controller is validated using a Controller-Hardware-in-the-Loop (CHIL) platform, where the physical EMS controller operates in real time against a real-time simulated microgrid. For a 24-hour PV–battery–load case study, the SEMS reduces coincident peak grid import by 22% and day-ahead energy cost by 8% compared with a fixed-threshold reactive controller. During islanding transitions, the secondary control restores voltage and frequency within regulatory limits in under 3 s. Across 5000 test cycles, execution time remains below the 100 ms real-time deadline, with a mean of 51.3 ± 0.3 ms. Sensitivity analysis of the MPC prediction horizon (R² = 0.984) quantifies the trade-off between computational effort and economic performance, demonstrating the practicality of the proposed SEMS for real-time deployment and future multi-microgrid applications.
- 18 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Model-Predictive Smart Energy Management System for Grid-Connected PV–Battery Microgrids with Hardware-in-the-Loop Validation
Smart energy management systems (SEMS) are increasingly used to coordinate photovoltaic (PV) generation, battery energy storage, and flexible loads in grid-connected and islandable microgrids. However, most reported SEMS are validated only through software simulations, leaving controller timing, converter nonlinearities, and communication delays largely unverified. This paper presents a hierarchical SEMS combining a receding-horizon model predictive control (MPC) secondary/tertiary economic dispatch layer with a primary droop-controlled inverter layer. The control problem is formulated as a convex quadratic program (QP) incorporating battery state-of-charge (SOC) dynamics, inverter power constraints, and a coincident-peak-aware cost objective. First-order optimality (KKT) conditions provide a shadow-price interpretation of battery dispatch, while recursive feasibility, input-to-state stability, and small-signal analysis establish closed-loop stability and exponential elimination of droop-induced steady-state error. The proposed controller is validated using a Controller-Hardware-in-the-Loop (CHIL) platform, where the physical EMS controller operates in real time against a real-time simulated microgrid. For a 24-hour PV–battery–load case study, the SEMS reduces coincident peak grid import by 22% and day-ahead energy cost by 8% compared with a fixed-threshold reactive controller. During islanding transitions, the secondary control restores voltage and frequency within regulatory limits in under 3 s. Across 5000 test cycles, execution time remains below the 100 ms real-time deadline, with a mean of 51.3 ± 0.3 ms. Sensitivity analysis of the MPC prediction horizon (R² = 0.984) quantifies the trade-off between computational effort and economic performance, demonstrating the practicality of the proposed SEMS for real-time deployment and future multi-microgrid applications.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Model Predictive Control Based Economic Operation of Grid-connected DC Microgrid System
Microgrids are becoming a quintessential option due to rapid growth of renewable energy technologies. However, the stochastic nature of renewable energy sources and variable power demand have introduced challenges such as voltage and frequency instabilities, complex power management and inter-action with the utility grid. In this paper, a Model Predictive Control (MPC) based energy management approach is proposed to facilitate stable and economic operation of grid-connected DC microgrids. Case studies are designed to evaluate the stability and economic operation of a DC microgrid under the proposed optimization based control strategy.
- 16 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Model Predictive Control Based Economic Operation of Grid-connected DC Microgrid System
Microgrids are becoming a quintessential option due to rapid growth of renewable energy technologies. However, the stochastic nature of renewable energy sources and variable power demand have introduced challenges such as voltage and frequency instabilities, complex power management and inter-action with the utility grid. In this paper, a Model Predictive Control (MPC) based energy management approach is proposed to facilitate stable and economic operation of grid-connected DC microgrids. Case studies are designed to evaluate the stability and economic operation of a DC microgrid under the proposed optimization based control strategy.
- Open Access
- 13 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (8) , 1261-1270
Comprehensive performance evaluation of various solar PV system configurations
This study presents a year‐long comprehensive performance analysis of four distinct solar photovoltaic (SPV) system configurations with central inverter, micro inverter, fixed axis structure and dual axis sun tracker (DAST) structure installed at the Indian Institute of Technology Kharagpur, West Bengal, India. Technical and economic performance indices are used to analyse the impact of inverter technology and DAST structure using field data of one year. Specifically, technical parameters specified by IEC 61724 are used to compare simulated results with field data from June 2017 to May 2018. The difference between the simulated and measured values of all the configurations is mostly attributed to the variation in solar irradiance and module temperature data. For simulation study, daily and monthly average values are considered while daily instantaneous data are used for measured values. Comparison of measured values through energy yield, capacity factor and performance ratio (PR) indices has confirmed the superiority of dual axis micro inverter system configuration. Additionally, the impact of seasonal variation on PR values for all four system configurations is also analysed. Economic performance for 25 years of project life using payback period, net present value and levelised cost of energy indices concludes dual axis central inverter system configuration as the most economical.
- 13 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (8) , 1261-1270
Open AccessComprehensive performance evaluation of various solar PV system configurations
This study presents a year‐long comprehensive performance analysis of four distinct solar photovoltaic (SPV) system configurations with central inverter, micro inverter, fixed axis structure and dual axis sun tracker (DAST) structure installed at the Indian Institute of Technology Kharagpur, West Bengal, India. Technical and economic performance indices are used to analyse the impact of inverter technology and DAST structure using field data of one year. Specifically, technical parameters specified by IEC 61724 are used to compare simulated results with field data from June 2017 to May 2018. The difference between the simulated and measured values of all the configurations is mostly attributed to the variation in solar irradiance and module temperature data. For simulation study, daily and monthly average values are considered while daily instantaneous data are used for measured values. Comparison of measured values through energy yield, capacity factor and performance ratio (PR) indices has confirmed the superiority of dual axis micro inverter system configuration. Additionally, the impact of seasonal variation on PR values for all four system configurations is also analysed. Economic performance for 25 years of project life using payback period, net present value and levelised cost of energy indices concludes dual axis central inverter system configuration as the most economical.