Junqing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junqing Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Lipeng Zhang
North China Electric Power University
3 shared publications - Haibo Yu
North China Electric Power University
2 shared publications - Luo Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
2 shared publications - Chengzhi Zhang
School of Electrical and Electronic Engineering, North China Electric Power University, Baoding 071003, China
1 shared publication - Dong Wang
North China Electric Power University
1 shared publication - Huilin Li
Department of Electrical Engineering, North China Electric Power University, Baoding 071051, China
1 shared publication
Latest Publications
- Open Access
- 13 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3078
Research on SCADA Data Preprocessing Method for Wind Turbines Based on Variable Grid Optimization (VGO-K-Means)
To address the high dimensionality, redundancy, and noise interference present in wind turbine Supervisory Control and Data Acquisition (SCADA) data, as well as the limitations of conventional K-means algorithms—including excessive reliance on manual parameter tuning and weak anti-noise performance—this paper proposes a Variable Grid Optimized K-means (VGO-K-means) preprocessing algorithm. Z-score standardization is adopted to unify feature magnitudes. Meanwhile, an adaptive grid density calculation strategy is developed to dynamically adjust grid resolution according to the value range of each dimension, enabling accurate characterization of the spatial distribution of monitoring samples. Furthermore, a multi-index voting mechanism integrating the silhouette coefficient, Davies–Bouldin index, and inertia metric is established to adaptively determine the optimal cluster number without manual intervention. Utilizing the density discrepancy between dense normal samples and sparse outliers, the proposed method identifies abnormal samples through a clustering density threshold. Validated on real wind farm SCADA data containing 892 manually labeled abnormal samples, the VGO-K-means algorithm achieves a precision of 96.8% and an F1-score (the harmonic mean of precision and recall) of 0.89. Under identical test conditions, it outperforms traditional K-means, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), and fixed-grid K-means methods. The entire workflow consumes only 3.9 s, achieving an excellent balance between detection accuracy and computational cost. The proposed framework provides a reliable and practical preprocessing solution for wind turbine condition monitoring data.
- 13 July 2026
- Published by MDPI AG in Electronics
- Vol. 15 (14) , 3078
Open AccessResearch on SCADA Data Preprocessing Method for Wind Turbines Based on Variable Grid Optimization (VGO-K-Means)
To address the high dimensionality, redundancy, and noise interference present in wind turbine Supervisory Control and Data Acquisition (SCADA) data, as well as the limitations of conventional K-means algorithms—including excessive reliance on manual parameter tuning and weak anti-noise performance—this paper proposes a Variable Grid Optimized K-means (VGO-K-means) preprocessing algorithm. Z-score standardization is adopted to unify feature magnitudes. Meanwhile, an adaptive grid density calculation strategy is developed to dynamically adjust grid resolution according to the value range of each dimension, enabling accurate characterization of the spatial distribution of monitoring samples. Furthermore, a multi-index voting mechanism integrating the silhouette coefficient, Davies–Bouldin index, and inertia metric is established to adaptively determine the optimal cluster number without manual intervention. Utilizing the density discrepancy between dense normal samples and sparse outliers, the proposed method identifies abnormal samples through a clustering density threshold. Validated on real wind farm SCADA data containing 892 manually labeled abnormal samples, the VGO-K-means algorithm achieves a precision of 96.8% and an F1-score (the harmonic mean of precision and recall) of 0.89. Under identical test conditions, it outperforms traditional K-means, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), and fixed-grid K-means methods. The entire workflow consumes only 3.9 s, achieving an excellent balance between detection accuracy and computational cost. The proposed framework provides a reliable and practical preprocessing solution for wind turbine condition monitoring data.
- Open Access
Impact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced conditions, while research on short-circuit faults under unbalanced voltage conditions is limited. Therefore, this paper aims to analyze the fault characteristics of inter-turn short circuits in the excitation windings of synchronous condensers under unbalanced grid voltage. Mathematical models were developed to represent the air gap flux density and stator parallel currents for four operating conditions: normal operation and inter-turn short circuit fault under balanced voltage, as well as a process without fault and with inter-turn short circuit fault under unbalanced voltage. By comparing the harmonic content and amplitudes, various aspects of the fault mechanism of synchronous condensers were revealed, and the operating characteristics under different conditions were analyzed. Considering the four aforementioned operating conditions, finite element simulation models were created for the TTS-300-2 synchronous condenser in a specific substation as a case study. The results demonstrate that the inter-turn short circuit fault in the excitation windings under unbalanced voltage leads to an increase in even harmonic currents in the stator parallel currents, particularly the second and fourth harmonics. This validates the accuracy of the theoretical analysis findings.
Open AccessImpact of Inter-Turn Short Circuit in Excitation Windings on Magnetic Field and Stator Current of Synchronous Condenser under Unbalanced Voltage
Inter-turn short circuit in the excitation windings of synchronous condensers is a common fault that directly impacts their normal operation. However, current fault analysis and diagnosis of synchronous condensers primarily rely on voltage-balanced conditions, while research on short-circuit faults under unbalanced voltage conditions is limited. Therefore, this paper aims to analyze the fault characteristics of inter-turn short circuits in the excitation windings of synchronous condensers under unbalanced grid voltage. Mathematical models were developed to represent the air gap flux density and stator parallel currents for four operating conditions: normal operation and inter-turn short circuit fault under balanced voltage, as well as a process without fault and with inter-turn short circuit fault under unbalanced voltage. By comparing the harmonic content and amplitudes, various aspects of the fault mechanism of synchronous condensers were revealed, and the operating characteristics under different conditions were analyzed. Considering the four aforementioned operating conditions, finite element simulation models were created for the TTS-300-2 synchronous condenser in a specific substation as a case study. The results demonstrate that the inter-turn short circuit fault in the excitation windings under unbalanced voltage leads to an increase in even harmonic currents in the stator parallel currents, particularly the second and fourth harmonics. This validates the accuracy of the theoretical analysis findings.
- Open Access
Calculation and Analysis of Rotor Thermal Static Field for Inter-Turn Short Circuit of Large Hydro-Generator Excitation Winding
Rotor winding inter-turn short circuit a common fault in hydro-generators. This fault would change the temperature, stress, and other thermal fields of a rotor and threaten the safe operation of the generator. In this paper, the Three Gorges hydro-generator is taken as an example. Mathematical models of three-dimensional temperature field and thermal stress field of rotor magnetic poles are established based on heat transfer theory and solved by finite element method. The temperature field, thermal deformation, and thermal stress distribution of magnetic poles in rotor winding inter-turn short circuit are calculated. On the basis of the calculation, the effects of the different turn numbers and positions of short circuit on the temperature, thermal deformation, and thermal stress of rotor magnetic poles are further studied. It is concluded that the thermal stress of the winding adjacent to the shorted turn would decrease, the thermal stress of the winding farther away from the shorted winding would increase, and so on. The results of this paper can provide references for inter-turn short circuit fault diagnosis and lay a foundation for the further studies of related faults.
Open AccessCalculation and Analysis of Rotor Thermal Static Field for Inter-Turn Short Circuit of Large Hydro-Generator Excitation Winding
Rotor winding inter-turn short circuit a common fault in hydro-generators. This fault would change the temperature, stress, and other thermal fields of a rotor and threaten the safe operation of the generator. In this paper, the Three Gorges hydro-generator is taken as an example. Mathematical models of three-dimensional temperature field and thermal stress field of rotor magnetic poles are established based on heat transfer theory and solved by finite element method. The temperature field, thermal deformation, and thermal stress distribution of magnetic poles in rotor winding inter-turn short circuit are calculated. On the basis of the calculation, the effects of the different turn numbers and positions of short circuit on the temperature, thermal deformation, and thermal stress of rotor magnetic poles are further studied. It is concluded that the thermal stress of the winding adjacent to the shorted turn would decrease, the thermal stress of the winding farther away from the shorted winding would increase, and so on. The results of this paper can provide references for inter-turn short circuit fault diagnosis and lay a foundation for the further studies of related faults.
- Open Access
- 22 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (8) , 1343-1350
Health condition assessment of wind turbine generators based on supervisory control and data acquisition data
As the running time of a wind turbine generator unit (WTGU) increases, the ageing and wear of its components will be aggravated gradually, which leads to deterioration of its operation condition. In order to ensure the safe and stable operation of WTGU and prolong its service life, it is of great significance to know the health condition of the WTGU and reasonably arrange maintenance. Based on the structure of the WTGU and the operation principle of the wind turbine generator (WTG), the condition assessment indexes of WTG were built, and the factors influencing the assessment index were determined. The relationship function between the assessment indexes and their influencing factors was established by using the least square support vector machine, which was used to determine the dynamic limitation of condition assessment index of WTG. The dynamic weight of each assessment index was used to characterise the influence of deterioration degree of different components on WTG conditions. Then the health conditions of WTG were evaluated using a similar cloud and fuzzy comprehensive assessment method separately. Finally, the proposed methods were verified by two examples including a direct‐drive permanent magnet wind generator and a doubly‐fed wind generator.
- 22 March 2019
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 13 (8) , 1343-1350
Open AccessHealth condition assessment of wind turbine generators based on supervisory control and data acquisition data
As the running time of a wind turbine generator unit (WTGU) increases, the ageing and wear of its components will be aggravated gradually, which leads to deterioration of its operation condition. In order to ensure the safe and stable operation of WTGU and prolong its service life, it is of great significance to know the health condition of the WTGU and reasonably arrange maintenance. Based on the structure of the WTGU and the operation principle of the wind turbine generator (WTG), the condition assessment indexes of WTG were built, and the factors influencing the assessment index were determined. The relationship function between the assessment indexes and their influencing factors was established by using the least square support vector machine, which was used to determine the dynamic limitation of condition assessment index of WTG. The dynamic weight of each assessment index was used to characterise the influence of deterioration degree of different components on WTG conditions. Then the health conditions of WTG were evaluated using a similar cloud and fuzzy comprehensive assessment method separately. Finally, the proposed methods were verified by two examples including a direct‐drive permanent magnet wind generator and a doubly‐fed wind generator.
- Open Access
Diagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
The inter-turn short circuit is a common fault in the synchronous generator. This fault is not easily detected at early stage. However, with the development of the fault, it will pose a threat to the safe operation of the generator. To detect the inter-turn short circuit of rotor winding, the feasibility of identifying the stator branch characteristics of synchronous generator during inter-turn short circuit was analyzed. In this paper, an on-line fault identification method based on Volterra kernel identification is presented. This method uses the stator branch voltage and stator unbalance branch current collected from the generator as input and output signals of the series model. Recursive batch least squares method is applied to calculate the three kernels of Volterra series. When the generator is in normal state or fault state, the Volterra kernel will change accordingly. Through the identification of the time-domain kernel of the nonlinear transfer model, the inter-turn short circuit fault of the synchronous generator is diagnosed. The correctness and effectiveness of this method is verified by using the data of fault experimental synchronous generator.
Open AccessDiagnosis of Inter-Turn Short Circuit of Synchronous Generator Rotor Winding Based on Volterra Kernel Identification
The inter-turn short circuit is a common fault in the synchronous generator. This fault is not easily detected at early stage. However, with the development of the fault, it will pose a threat to the safe operation of the generator. To detect the inter-turn short circuit of rotor winding, the feasibility of identifying the stator branch characteristics of synchronous generator during inter-turn short circuit was analyzed. In this paper, an on-line fault identification method based on Volterra kernel identification is presented. This method uses the stator branch voltage and stator unbalance branch current collected from the generator as input and output signals of the series model. Recursive batch least squares method is applied to calculate the three kernels of Volterra series. When the generator is in normal state or fault state, the Volterra kernel will change accordingly. Through the identification of the time-domain kernel of the nonlinear transfer model, the inter-turn short circuit fault of the synchronous generator is diagnosed. The correctness and effectiveness of this method is verified by using the data of fault experimental synchronous generator.
- 4 August 2015
- Published by Springer Nature
- p. 29-38
Fault Features Study of Doubly Fed Induction Generators on the Stator Windings Turn-to-Turn Short Circuit
- 4 August 2015
- Published by Springer Nature
- p. 29-38
Fault Features Study of Doubly Fed Induction Generators on the Stator Windings Turn-to-Turn Short Circuit
- 4 August 2015
- Published by Springer Nature
- p. 47-54
Rotor Fault Slot Positioning of Doubly Fed Induction Generators Based on Wavelet Decomposition
- 4 August 2015
- Published by Springer Nature
- p. 47-54
Rotor Fault Slot Positioning of Doubly Fed Induction Generators Based on Wavelet Decomposition
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 733-736
Static state stability analysis of AC-excited generators
- 21 June 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 733-736
Static state stability analysis of AC-excited generators