YTYoshitaka Terada

Yoshitaka Terada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshitaka Terada has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Successful treatment of rectal cancer with pelvic abscess using transrectal drainage followed by laparoscopic radical resection: a case report

    by Yusuke Nishina, Hiroyuki Ohta, Yoshitaka Terada, Hiroya Akabori, Naomi Kitamura, Nozomi Nagai, Eiji Mekata

    The incidence of rectal cancer with a pelvic abscess is rare; hence, treatment strategies are difficult because both malignant and infectious inflammation need to be addressed. Here, we report the case of a 53-year-old man diagnosed with rectal cancer accompanied by a pelvic abscess. We performed transrectal drainage of the abscess, and a transanal rectal drainage tube was inserted into the abscess cavity. His symptoms rapidly improved, and computed tomography showed that the pelvic abscess had disappeared. Six weeks after drainage, radical laparoscopic Hartmann’s procedure with resection of the rectal cancer and incision drainage scar was performed. After adjuvant chemotherapy, laparoscopic stoma closure was performed a year after the operation. The patient showed no evidence of cancer recurrence 1.5 years after radical surgery. Transrectal drainage followed by laparoscopic radical resection can be a less invasive and effective treatment for rectal cancer accompanied by a pelvic abscess.


  • Incidence of surgical site infections with triclosan-coated monofilament versus multifilament sutures in elective colorectal surgery

    by Yoshitaka Terada, Toru Miyake, Tomoyuki Ueki, Tomoharu Shimizu, Masatsugu Kojima, Katsushi Takebayashi, Hiromitsu Maehira, Sachiko Kaida, Tsuyoshi Yamaguchi, Hiroya Iida, et al.

    Purpose Surgical site infections (SSIs) are the most frequent complication of abdominal surgery. Using triclosan-coated sutures for abdominal wall closure reportedly reduces the incidence of SSIs. However, the SSI incidence has not been compared between the use of triclosan-coated multifilament and triclosan-coated monofilament sutures. We, therefore, compared the incidence of incisional SSIs between the use of triclosan-coated polyglactin 910 sutures (Vicryl Plus) and triclosan-coated polydioxanone sutures (PDS Plus). Methods This observational cohort study was conducted on 318 consecutive patients who underwent elective colorectal cancer surgery at the Shiga University of Medical Science Hospital from January 2015 to December 2018. Based on the suture type for abdominal wall closure, 151 patients were enrolled in the PDS Plus group, and 167 were enrolled in the Vicryl Plus group. Results The two suture groups were not significantly different in terms of risk factors for SSIs. Other postoperative complications also did not differ markedly between the two groups. In the multivariate logistic regression analysis, the presence of stoma was the only independent risk factor for incisional SSIs. Conclusion The incidence of incisional SSIs was unaffected by the type of triclosan-coated sutures. The presence of stoma was an independent risk factor for incisional SSIs.


  • Open Access

    Early experience with a new integrated microwave surgical device, Acrosurg Revo®, for laparoscopic surgery

    by Yoshitaka Terada, Hiroya Akabori, Hiroyuki Ohta, Yusuke Nishina, Eji Mekata

    Introduction: Abdominal surgery uses various energy devices for vessel sealing, tissue dissection, and detachment. Currently, Acrosurg Revo® (Nikkiso Co., Ltd., Tokyo, Japan), a novel energy device using microwaves, has been developed for use in laparoscopic surgery. This report describes the early clinical experience of using this device in two cases of laparoscopic surgery. Presentation of case: Case 1 was of a 64-year-old woman who underwent laparoscopic abdominal incisional hernia repair. Case 2 was of a 56-year-old man with a diagnosis of ascending and sigmoid colon cancer who underwent laparoscopic right hemicolectomy and sigmoid colectomy with D3 dissection. Each surgery was completed using Acrosurg Revo® and an endoscopic electrosurgical unit. The postoperative course was uneventful, and both patients were discharged from the hospital without any complications. Discussion: With this new and novel device, vessel sealing, hemostasis, coagulation, tissue dissection, and detachment were all possible. Notably, there was no spark or mist that hindered the surgical field of view. Furthermore, because microwave coagulation did not result in tissue carbonization, there was a considerable decrease in device tip contamination. Conclusion: The Acrosurg Revo® may be a useful energy device for laparoscopic surgery. Highlights: