Michael G. Tal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael G. Tal has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Alexander S Yevzlin
Department of Medicine, University of Michigan, Ann Arbor, MI, USA
2 shared publications- Alexander S. Yevzlin
University of Michigan
2 shared publications Ron Livne
Embrace Medical Ltd., Tel Aviv, Israel
2 shared publications- Andrew I. Spielman
New York University
1 shared publication Anne Covey
Memorial Sloan Kettering Cancer Center, New York, NY, USA
1 shared publication- Azza Naif
Muhimbili University of Health and Allied Sciences
1 shared publication
Latest Publications
- 27 November 2024
- Published by Springer Nature
- p. 111-122
Placement and Maintenance of Tunneled Hemodialysis Catheters
- 27 November 2024
- Published by Springer Nature
- p. 111-122
Placement and Maintenance of Tunneled Hemodialysis Catheters
- Open Access
- 23 November 2023
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 26 (1) , 211-216
Prospective evaluation of efficacy and safety of distal radial and radial artery access using a novel articulating-tip guidewire
Background: Guidewire-facilitated access to peripheral vessels is commonplace in vascular access, but guidewire insertion into small vessels, such as the radial and distal radial arteries, can still be challenging. Failure to gain access on the first attempt may contribute to increased risks of procedural complications, such as vessel dissection, spasm, and occlusion. This research assessed the safety and efficacy of radial and distal radial artery access using a novel, FDA-cleared, small-core-diameter guidewire with an articulating tip, under ultrasound guidance. Methods: This was a prospective, single-arm, single-center trial. Patients in need of vascular access were screened for participation and enrolled in the study. Guidewire insertion was attempted by four physicians (three interventional radiologists and an interventional nephrologist) at 162 arterial sites—65 radial and 97 distal radial, having a mean diameter of 2.0 mm. Results: First-attempt successful placement of the guidewire in the artery occurred at 87.6% of access sites (142/162) and differences in the success rate between the radial and distal radial arteries or between vessels with diameter smaller or larger than 2 mm were not observed (62/68 and 67/77, respectively; p = 0.6). Four of the five reported adverse events were unrelated to the study device or procedure. Two of the three distal radial artery spasms occurred before the guidewire was used. The other two events were a radial artery spasm, and a distal radial artery site hematoma. All adverse events resolved spontaneously. Conclusions: First-attempt placement of a novel articulating tip guidewire in the radial and distal radial arteries occurred at a high rate in our study and was not associated with safety concerns.
- 23 November 2023
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 26 (1) , 211-216
Open AccessProspective evaluation of efficacy and safety of distal radial and radial artery access using a novel articulating-tip guidewire
Background: Guidewire-facilitated access to peripheral vessels is commonplace in vascular access, but guidewire insertion into small vessels, such as the radial and distal radial arteries, can still be challenging. Failure to gain access on the first attempt may contribute to increased risks of procedural complications, such as vessel dissection, spasm, and occlusion. This research assessed the safety and efficacy of radial and distal radial artery access using a novel, FDA-cleared, small-core-diameter guidewire with an articulating tip, under ultrasound guidance. Methods: This was a prospective, single-arm, single-center trial. Patients in need of vascular access were screened for participation and enrolled in the study. Guidewire insertion was attempted by four physicians (three interventional radiologists and an interventional nephrologist) at 162 arterial sites—65 radial and 97 distal radial, having a mean diameter of 2.0 mm. Results: First-attempt successful placement of the guidewire in the artery occurred at 87.6% of access sites (142/162) and differences in the success rate between the radial and distal radial arteries or between vessels with diameter smaller or larger than 2 mm were not observed (62/68 and 67/77, respectively; p = 0.6). Four of the five reported adverse events were unrelated to the study device or procedure. Two of the three distal radial artery spasms occurred before the guidewire was used. The other two events were a radial artery spasm, and a distal radial artery site hematoma. All adverse events resolved spontaneously. Conclusions: First-attempt placement of a novel articulating tip guidewire in the radial and distal radial arteries occurred at a high rate in our study and was not associated with safety concerns.
- 1 August 2023
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 221 (2) , 277-278
The Global Reading Room: Treating a Fibrin Sheath
- 1 August 2023
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 221 (2) , 277-278
The Global Reading Room: Treating a Fibrin Sheath
- Open Access
- 8 August 2022
- Published by Springer Nature in Reproductive Sciences
- Vol. 30 (4) , 1366-1375
Pressure-Induced Fibroid Ischemia: First-In-Human Experience with a Novel Device for Laparoscopic Treatment of Symptomatic Uterine Fibroids
The purpose of this study was to assess the feasibility of use of a novel uterine fibroid treatment device hypothesized to cause fibroid infarction by increasing intra-tumoral pressure. Between August 2019 and January 2020, 21 uterine fibroids were treated in 16 symptomatic pre-menopausal black women. Pelvic magnetic resonance imaging was performed before the procedure, a day after the procedure and at 1, 3, 6, and 12 months. The subjects were also followed for clinical outcomes and quality of life up to 12 months at a single investigational site. At 3 months, the mean reduction in the fibroid volume was 36.3% (P = .002). Incremental reduction in volume peaked at the end of the follow-up, at the 12-month mark (60.4%; P = .008). There were no procedures in which the users failed to perform laparoscopic pressure suturing of fibroids with the pressure-induced fibroid ischemia device. Improvement in the quality of life was evident in the Health-Related Quality of Life total, Energy/Mood, Control, and Sexual Function domains of the Uterine Fibroid Symptom and Quality of Life questionnaire at 3 months post-procedure. Unanticipated risks were not identified. Serious adverse events were not identified. The initial clinical assessment of the pressure-induced fibroid ischemia device supports feasibility of the approach and does not reveal serious safety concerns. Trial is currently being registered retrospectively (This was a feasibility study and therefore registration was not mandatory).
- 8 August 2022
- Published by Springer Nature in Reproductive Sciences
- Vol. 30 (4) , 1366-1375
Open AccessPressure-Induced Fibroid Ischemia: First-In-Human Experience with a Novel Device for Laparoscopic Treatment of Symptomatic Uterine Fibroids
The purpose of this study was to assess the feasibility of use of a novel uterine fibroid treatment device hypothesized to cause fibroid infarction by increasing intra-tumoral pressure. Between August 2019 and January 2020, 21 uterine fibroids were treated in 16 symptomatic pre-menopausal black women. Pelvic magnetic resonance imaging was performed before the procedure, a day after the procedure and at 1, 3, 6, and 12 months. The subjects were also followed for clinical outcomes and quality of life up to 12 months at a single investigational site. At 3 months, the mean reduction in the fibroid volume was 36.3% (P = .002). Incremental reduction in volume peaked at the end of the follow-up, at the 12-month mark (60.4%; P = .008). There were no procedures in which the users failed to perform laparoscopic pressure suturing of fibroids with the pressure-induced fibroid ischemia device. Improvement in the quality of life was evident in the Health-Related Quality of Life total, Energy/Mood, Control, and Sexual Function domains of the Uterine Fibroid Symptom and Quality of Life questionnaire at 3 months post-procedure. Unanticipated risks were not identified. Serious adverse events were not identified. The initial clinical assessment of the pressure-induced fibroid ischemia device supports feasibility of the approach and does not reveal serious safety concerns. Trial is currently being registered retrospectively (This was a feasibility study and therefore registration was not mandatory).
- Open Access
- 17 September 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (11) , 1257-1262
Initial Clinical Experience with a Symmetric Tip Tunneled Hemodialysis Catheter Without Side Holes
The purpose of this article is to assess the performance and safety of a novel, symmetric, side-hole–free tunneled cuffed catheter hypothesized to sustain adequate flow without the need for side holes. Between November 2016 and January 2019, Pristine hemodialysis catheters were placed de novo in 45 end-stage renal disease patients (27 males and 18 females) at a single investigational site. Forty-one catheters were placed in the right and four in the left internal jugular vein. There were no incidents of insertion failure. Patients had dialysis three times per week and were followed at four investigational sites. Nominal catheter flows, incidence of poor flow, and catheter-related infections were recorded at each dialysis session and analyzed. The average follow-up time was 161.69 days for a total of 7116 catheter days. Nine patients died from reasons unrelated to the catheter and one patient switched to fistula. Four patients had poor flows necessitating catheter replacement. Four patients had catheter-related bloodstream infections which resolved with antibiotics. These equate to 0.56 events per 1000 catheter days. Catheter survival was 100%, 97.6%, and 89.7% at 30, 90, and 180 days, respectively. The initial clinical assessment of the symmetric Pristine hemodialysis catheter featuring a Y-tip devoid of side holes revealed good catheter performance and survival and a low complication rate.
- 17 September 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (11) , 1257-1262
Open AccessInitial Clinical Experience with a Symmetric Tip Tunneled Hemodialysis Catheter Without Side Holes
The purpose of this article is to assess the performance and safety of a novel, symmetric, side-hole–free tunneled cuffed catheter hypothesized to sustain adequate flow without the need for side holes. Between November 2016 and January 2019, Pristine hemodialysis catheters were placed de novo in 45 end-stage renal disease patients (27 males and 18 females) at a single investigational site. Forty-one catheters were placed in the right and four in the left internal jugular vein. There were no incidents of insertion failure. Patients had dialysis three times per week and were followed at four investigational sites. Nominal catheter flows, incidence of poor flow, and catheter-related infections were recorded at each dialysis session and analyzed. The average follow-up time was 161.69 days for a total of 7116 catheter days. Nine patients died from reasons unrelated to the catheter and one patient switched to fistula. Four patients had poor flows necessitating catheter replacement. Four patients had catheter-related bloodstream infections which resolved with antibiotics. These equate to 0.56 events per 1000 catheter days. Catheter survival was 100%, 97.6%, and 89.7% at 30, 90, and 180 days, respectively. The initial clinical assessment of the symmetric Pristine hemodialysis catheter featuring a Y-tip devoid of side holes revealed good catheter performance and survival and a low complication rate.
- Open Access
- 21 July 2021
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 24 (4) , 614-619
Catheter-related blood stream infection in hemodialysis patients with symmetric tunneled non-side-hole hemodialysis catheters
Background: Tunneled hemodialysis catheter-related bloodstream infection is a major cause of morbidity and mortality in end-stage renal disease patients. Side holes positioned near the tip of catheters have been linked to formation of thrombi, which, in turn, have been implicated in predisposition to infection. In addition, side holes allow spillage of catheter locking solution, including antibiotics, thereby minimizing the lock solution’s effect on the catheter tip. This study assessed the infection events that occurred in a series of hemodialysis patients using a non-side-hole catheter. Methods: Over a period of 2 years, a novel symmetric-tip non-side-hole catheter was placed in 60 patients. Hemodialysis was performed thrice weekly. Prescribed dialyzer flows were 300–350 mL/min. Catheters were routinely locked with heparin 5000 units/mL between treatments. Patients were followed up for any catheter related complications, specifically infection events. Results: Seven events of catheter-related bloodstream infection occurred for a rate of 0.76 events per 1000 catheter-days, with the first event occurring 9 weeks after insertion. These events were treated by locking the affected catheter with 2 g of clindamycin in 2 mL of heparin 1000 units/mL and administration of intravenous antibiotics, in most cases, for 7–14 days. Two catheters were removed due to infection. Conclusions: Catheter-related bloodstream infections with non-side-hole hemodialysis catheters do occur at a relatively low rate and in this initial preliminary study it seems that most of these infections can be successfully treated without removal of the affected catheters.
- 21 July 2021
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 24 (4) , 614-619
Open AccessCatheter-related blood stream infection in hemodialysis patients with symmetric tunneled non-side-hole hemodialysis catheters
Background: Tunneled hemodialysis catheter-related bloodstream infection is a major cause of morbidity and mortality in end-stage renal disease patients. Side holes positioned near the tip of catheters have been linked to formation of thrombi, which, in turn, have been implicated in predisposition to infection. In addition, side holes allow spillage of catheter locking solution, including antibiotics, thereby minimizing the lock solution’s effect on the catheter tip. This study assessed the infection events that occurred in a series of hemodialysis patients using a non-side-hole catheter. Methods: Over a period of 2 years, a novel symmetric-tip non-side-hole catheter was placed in 60 patients. Hemodialysis was performed thrice weekly. Prescribed dialyzer flows were 300–350 mL/min. Catheters were routinely locked with heparin 5000 units/mL between treatments. Patients were followed up for any catheter related complications, specifically infection events. Results: Seven events of catheter-related bloodstream infection occurred for a rate of 0.76 events per 1000 catheter-days, with the first event occurring 9 weeks after insertion. These events were treated by locking the affected catheter with 2 g of clindamycin in 2 mL of heparin 1000 units/mL and administration of intravenous antibiotics, in most cases, for 7–14 days. Two catheters were removed due to infection. Conclusions: Catheter-related bloodstream infections with non-side-hole hemodialysis catheters do occur at a relatively low rate and in this initial preliminary study it seems that most of these infections can be successfully treated without removal of the affected catheters.
- Open Access
- 2 July 2021
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 24 (2) , 232-237
Staphylococcus aureus accumulation at the tip of hemodialysis catheters with or without tip side holes in catheter related bloodstream infection in a large animal
Eighty percent of hemodialysis patients start their dialysis with a tunneled hemodialysis catheter. Catheter related bacteremia is the second most common cause of death in these patients. Side holes near the tips of the tunneled cuffed central venous catheters are associated with accumulation of thrombus, which can lead to catheter dysfunction and, possibly, also to catheter-related infection. To assess the hypothesis that a catheter without side holes would be associated with less bacterial growth, this study compared the susceptibility of a side-hole-free catheter to accumulation of pathogenic bacteria at the catheter tip with that of two catheters which have side holes. Eight tunneled cuffed double-lumen central venous catheters were inserted into both jugular veins of four sheep; one side-hole-free and one control catheter with side holes at the tip in each animal. Staphylococcus aureus bacteria were then infused intravenously to cause bacteremia. Six hours later, the catheters were removed, the clots that accumulated in their tips were collected and cultured, and the bacterial colonies were counted after additional 12 h of incubation. Bacteria grew on culture plates seeded with the clot homogenate obtained from the tips of all catheters. The colony counts from the catheters with side holes at the tip exceeded the colony counts of bacteria accumulated in the tips of the side-hole-free hemodialysis catheters by one or more orders of magnitude, with a difference of at least two orders of magnitude observed in three of the four intra-animal comparisons. In paired intra-animal post-inoculation comparison made in this limited study, fewer colony forming units of pathogenic bacteria accumulated at the tip of the side-hole-free catheters than at the tips of the catheters which have side holes. This may translate to a decreased rate of catheter-related blood stream infections in the side-hole-free catheters.
- 2 July 2021
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 24 (2) , 232-237
Open AccessStaphylococcus aureus accumulation at the tip of hemodialysis catheters with or without tip side holes in catheter related bloodstream infection in a large animal
Eighty percent of hemodialysis patients start their dialysis with a tunneled hemodialysis catheter. Catheter related bacteremia is the second most common cause of death in these patients. Side holes near the tips of the tunneled cuffed central venous catheters are associated with accumulation of thrombus, which can lead to catheter dysfunction and, possibly, also to catheter-related infection. To assess the hypothesis that a catheter without side holes would be associated with less bacterial growth, this study compared the susceptibility of a side-hole-free catheter to accumulation of pathogenic bacteria at the catheter tip with that of two catheters which have side holes. Eight tunneled cuffed double-lumen central venous catheters were inserted into both jugular veins of four sheep; one side-hole-free and one control catheter with side holes at the tip in each animal. Staphylococcus aureus bacteria were then infused intravenously to cause bacteremia. Six hours later, the catheters were removed, the clots that accumulated in their tips were collected and cultured, and the bacterial colonies were counted after additional 12 h of incubation. Bacteria grew on culture plates seeded with the clot homogenate obtained from the tips of all catheters. The colony counts from the catheters with side holes at the tip exceeded the colony counts of bacteria accumulated in the tips of the side-hole-free hemodialysis catheters by one or more orders of magnitude, with a difference of at least two orders of magnitude observed in three of the four intra-animal comparisons. In paired intra-animal post-inoculation comparison made in this limited study, fewer colony forming units of pathogenic bacteria accumulated at the tip of the side-hole-free catheters than at the tips of the catheters which have side holes. This may translate to a decreased rate of catheter-related blood stream infections in the side-hole-free catheters.
- Open Access
- 25 December 2020
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 23 (1) , 128-134
Clot accumulation at the tip of hemodialysis catheters in a large animal model
The issue of side holes in the tips of the tunneled cuffed central venous catheters is complex and has been subject to longstanding debate. This study sought to compare the clotting potential of the side-hole-free Pristine hemodialysis catheter with that of a symmetric catheter with side holes. Both jugular veins of five goats were catheterized with the two different catheters. The catheters were left in place for 4 weeks and were flushed and locked with heparin thrice weekly. The aspirated intraluminal clot length was assessed visually prior to each flushing. In addition, the size and weight of the clot were recorded upon catheter extraction at the end of the 4-week follow-up The mean intraluminal clot length observed during the entire study follow-up measured up to a mean of 0.66 cm in the GlidePath (95% CI, 0.14–1.18) and 0.19 cm in the Pristine hemodialysis catheter (95% CI, −0.33 to 0.71), the difference being statistically significant (p = 0.026). On average, 0.01 g and 0.07 g of intraluminal clot were retrieved from the Pristine and GlidePath catheters, respectively (p = 0.052). The Pristine hemodialysis catheter was largely superior to a standard side hole catheter in impeding clot formation, and, contrary to the side hole catheter, allowed for complete aspiration of the intraluminal clot.
- 25 December 2020
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 23 (1) , 128-134
Open AccessClot accumulation at the tip of hemodialysis catheters in a large animal model
The issue of side holes in the tips of the tunneled cuffed central venous catheters is complex and has been subject to longstanding debate. This study sought to compare the clotting potential of the side-hole-free Pristine hemodialysis catheter with that of a symmetric catheter with side holes. Both jugular veins of five goats were catheterized with the two different catheters. The catheters were left in place for 4 weeks and were flushed and locked with heparin thrice weekly. The aspirated intraluminal clot length was assessed visually prior to each flushing. In addition, the size and weight of the clot were recorded upon catheter extraction at the end of the 4-week follow-up The mean intraluminal clot length observed during the entire study follow-up measured up to a mean of 0.66 cm in the GlidePath (95% CI, 0.14–1.18) and 0.19 cm in the Pristine hemodialysis catheter (95% CI, −0.33 to 0.71), the difference being statistically significant (p = 0.026). On average, 0.01 g and 0.07 g of intraluminal clot were retrieved from the Pristine and GlidePath catheters, respectively (p = 0.052). The Pristine hemodialysis catheter was largely superior to a standard side hole catheter in impeding clot formation, and, contrary to the side hole catheter, allowed for complete aspiration of the intraluminal clot.
- 4 May 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (1) , 114-119
Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis
To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P < 0.01, χ2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P < 0.01, χ2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.
- 4 May 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (1) , 114-119
Association Between Disruption of Fibrin Sheaths Using Percutaneous Transluminal Angioplasty Balloons and Late Onset of Central Venous Stenosis
To compare the rates of central venous stenosis in patients undergoing hemodialysis who underwent disruption of fibrin sheath with percutaneous transluminal angioplasty balloons and those who underwent over-the-wire catheter exchange. This study is a retrospective review of 209 percutaneous transluminal angioplasty balloon disruption and 1304 over-the-wire catheter exchange procedures performed in 753 patients. Approval from the Human Investigations Committee was obtained for this study. Up to 10-year follow-up was performed. A χ2 test was used to compare the rates of central venous stenosis after balloon disruption versus catheter exchange. A t-test was used to compare time to central venous stenosis development. Of the 753 patients in the study, 127 patients underwent balloon disruption of fibrin sheath and 626 had catheter exchange. Within the balloon disruption group, 18 (14.2%) of 127 patients subsequently developed central venous stenosis, compared with 44 (7.0%) of 626 in the catheter exchange group (P < 0.01, χ2 test). Time to central venous stenosis development was approximately 3 years in both groups and not significantly different (1371 and 1010 days, P = 0.20). A total of 25.2% of patients in the balloon disruption group had four or more subsequent catheter exchanges, versus 12.6% in the catheter exchange group (P < 0.01, χ2 test). In conclusions, there is a possible association between percutaneous transluminal angioplasty balloon disruption of fibrin sheath and late-onset central venous stenosis. Because venography was not routinely performed in catheter exchange patients, future randomized studies are necessary to confirm these findings.
- Open Access
- 1 October 2009
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 10 (4) , 288-289
Data-driven Tunneled Catheter Selection: Oxymoron?
- 1 October 2009
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 10 (4) , 288-289
Open AccessData-driven Tunneled Catheter Selection: Oxymoron?