Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xue Hu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial Intelligence-Driven Framework for Augmented Reality Markerless Navigation in Knee Surgery

    by Xue Hu, Fabrizio Cutolo, Hisham Iqbal, Johann Henckel, Ferdinando Rodriguez Y Baena

    Conventional orthopaedic navigation systems depend on marker-based tracking, which may introduce additional skin incisions, increase the risk and discomfort for the patient, and entail increased workflow complexity. The guidance is conveyed via 2D monitors, which may distract the surgeon and increase the cognitive burden. This study presents an Artificial Intelligence (AI) - driven surgical navigation framework for knee replacement surgery. The system comprises an Augmented Reality (AR) interface that combines an occlusions-robust deep learning-based markerless bone tracking and registration algorithm with a commercial HoloLens 2 headset calibrated for the user’s perspective on both eyes. The feasibility of such a system in navigating a bone drilling task is investigated with an experienced orthopaedic surgeon on three cadaveric knees under realistic operating room conditions. After registering an implant model to computed tomography (CT) scans, the preoperative plans are determined based on the location of the fixation pins. Navigation accuracy is quantified using a highly accurate optical tracking system. The achieved drilling error is 7.88±2.41mm in translation and 7.36±1.77° in orientation. The results demonstrate the viability of integrating AI and AR technology to navigate knee surgery.


  • Occlusion-Robust Visual Markerless Bone Tracking for Computer-Assisted Orthopedic Surgery

    by Xue Hu, Anh Nguyen, Ferdinando Rodriguez Y Baena

    Conventional computer-assisted orthopaedic navigation systems rely on the tracking of dedicated optical markers for patient poses, which makes the surgical workflow more invasive, tedious, and expensive. To address this limitation, some previous studies have successfully adapted the existing deep learning framework to automatically segment and register the exposed femur surface for knee surgery, but these fail under real-world occlusion which often happens during a real surgical procedure. Furthermore, such methods are hardware-specific and not accurate enough for clinic acceptance. In this paper, we propose a learning-based RGB-D markerless tracking method that is robust against occlusion. To avoid expensive surgical data collection, which is a well-known challenge for surgical task training, we generate synthetic RGB-D data with various occlusion scenarios. A new segmentation network that features dynamic region-of-interest prediction and 3D geometric segmentation is designed, to learn the occlusion-related knowledge from simulated instances. Intensive experiments show that our proposed method achieves new state-of-the-art results in markerless bone tracking. Furthermore, our method generalises well to new cameras and new target models, including a cadaver, without the need for network retraining. By using a high-quality RGB-D camera, our proposed visual tracking method can achieve an accuracy of 1-2° and 2-4 mm on a phantom knee, which meets the clinical standard.


  • Head-Mounted Augmented Reality Platform for Markerless Orthopaedic Navigation

    by Xue Hu, Ferdinando Rodriguez Y Baena, Fabrizio Cutolo

    Visual augmented reality (AR) has the potential to improve the accuracy, efficiency and reproducibility of computer-assisted orthopaedic surgery (CAOS). AR Head-mounted displays (HMDs) further allow non-eye-shift target observation and egocentric view. Recently, a markerless tracking and registration (MTR) algorithm was proposed to avoid the artificial markers that are conventionally pinned into the target anatomy for tracking, as their use prolongs surgical workflow, introduces human-induced errors, and necessitates additional surgical invasion in patients. However, such an MTR-based method has neither been explored for surgical applications nor integrated into current AR HMDs, making the ergonomic HMD-based markerless AR CAOS navigation hard to achieve. To these aims, we present a versatile, device-agnostic and accurate HMD-based AR platform. Our software platform, supporting both video see-through (VST) and optical see-through (OST) modes, integrates two proposed fast calibration procedures using a specially designed calibration tool. According to the camera-based evaluation, our AR platform achieves a display error of 6.31 2.55 arcmin for VST and 7.72 3.73 arcmin for OST. A proof-of-concept markerless surgical navigation system to assist in femoral bone drilling was then developed based on the platform and Microsoft HoloLens 1. According to the user study, both VST and OST markerless navigation systems are reliable, with the OST system providing the best usability. The measured navigation error is 4.90 1.04 mm, 5.96 2.22 for VST system and 4.36 0.80 mm, 5.65 1.42 for OST system.


  • Open Access

    Automatic Bone Surface Restoration for Markerless Computer-assisted Orthopaedic Surgery

    by Xue Hu, Ferdinando Rodriguez Y Baena

    An automatic markerless knee tracking and registration algorithm has been proposed in the literature to avoid the marker insertion required by conventional computer-assisted knee surgery, resulting in a shorter and less invasive surgical workflow. However, such an algorithm considers intact femur geometry only. The bone surface modification is inevitable due to intra-operative intervention. The mismatched correspondences will degrade the reliability of registered target pose. To solve this problem, this work proposed a supervised deep neural network to automatically restore the surface of processed bone. The network was trained on a synthetic dataset that consists of real depth captures of a model leg and simulated realistic femur cutting. According to the evaluation on both synthetic data and real-time captures, the registration quality can be effectively improved by surface reconstruction. The improvement in tracking accuracy is only evident over test data, indicating the need for future enhancement of the dataset and network.

  • Open Access

    Markerless Navigation System for Orthopaedic Knee Surgery: A Proof of Concept Study

    by Xue Hu, He Liu, Ferdinando Rodriguez Y. Baena

    Current computer-assisted surgical navigation systems mainly rely on optical markers screwed into the bone for anatomy tracking. The insertion of these percutaneous markers increases operating complexity and causes additional harm to the patient. A markerless tracking and registration algorithm has recently been proposed to avoid anatomical markers for knee surgery. The femur points were directly segmented from the recorded RGBD scene by a neural network and then registered to a pre-scanned femur model for the real-time pose. However, in a practical setup such a method can produce unreliable registration results, especially in rotation. Furthermore, its potential application in surgical navigation has not been demonstrated. In this paper, we first improved markerless registration accuracy by adopting a bounded-ICP (BICP) technique, where an estimate of the remote hip centre, acquired also in a markerless way, was employed to constrain distal femur alignment. Then, a proof-of-concept markerless navigation system was proposed to assist in typical knee drilling tasks. Two example setups for global anchoring were proposed and tested on a phantom leg. Our BICP-based markerless tracking and registration method has better angular accuracy and stability than the original method, bringing our straightforward, less invasive markerless navigation approach one step closer to clinical application. According to user tests, our proposed optically anchored navigation system achieves comparable accuracy with the state-of-the-art (3.64± 1.49 mm in position and 2.13±0.81° in orientation). Conversely, our visually anchored, optical tracker-free setup has a lower accuracy (5.86± 1.63 mm in position and 4.18±1.44° in orientation), but is more cost-effective and flexible in the operating room.


  • Open Access

    Alignment-Free Offline Calibration of Commercial Optical See-Through Head-Mounted Displays With Simplified Procedures

    by Xue Hu, Ferdinando Rodriguez Y Baena, Fabrizio Cutolo

    Despite the growing availability of self-contained augmented reality head-mounted displays (AR HMDs) based on optical see-through (OST) technology, their potential applications across highly challenging medical and industrial settings are still hampered by the complexity of the display calibration required to ensure the locational coherence between the real and virtual elements. The calibration of commercial OST displays remains an open challenge due to the inaccessibility of the user’s perspective and the limited hardware information available to the end-user. State-of-the-art calibrations usually comprise both offline and online stages. The offline calibration at a generic viewpoint provides a starting point for the subsequent refinements and it is crucial. Current offline calibration methods either heavily rely on the user-alignment or require complicated hardware calibrations, making the overall procedure subjective and/or tedious. To address this problem, in this work we propose two fully alignment-free calibration methods with less complicated hardware calibration procedures compared with state-of-the-art solutions. The first method employs an eye-replacement camera to compute the rendering camera’s projection matrix based on photogrammetry techniques. The second method controls the rendered object position in a tracked 3D space to compensate for the parallax-related misalignment for a generic viewpoint. Both methods have been tested on Microsoft HoloLens 1. Quantitative results show that the average overlay misalignment is fewer than 4 pixels (around 1.5 mm or 9 arcmin) when the target stays within arm’s reach. The achieved misalignment is much lower than the HoloLens default interpupillary distance (IPD)-based correction, and equivalent but with lower variance than the Single Point Active Alignment Method (SPAAM)-based calibration. The two proposed methods offer strengths in complementary aspects and can be chosen according to the user’s needs. We also provide several update schemes for the two methods that can be integrated for an on-line viewpoint-dependent refinement of the calibration parameters. Both methods have been integrated into a Unity3D-based framework and can be directly applied to Unity-assisted devices.