Ozgur Cemal Ozerdem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ozgur Cemal Ozerdem has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Samuel Nii Tackie
Department of Electrical and Electronic Engineering, Near East University, Nicosia 99138, Northern Cyprus
3 shared publications - Ali Sidi Abubaker Hesri1 shared publication
- Ebrahim Babaei
Department of Electrical and Electronic Engineering, Near East University, Nicosia 99138, Northern Cyprus
1 shared publication - Malabika Basu
School of Electrical and Electronic Engineering, Dublin Institute of Technology, Dublin, Ireland
1 shared publication - Murat Fahrioglu
Dept. of Electr. & Comput. Eng., Wisconsin Univ., Madison, WI, USA
1 shared publication Salim Tsowa Mohammed
1 shared publication
Latest Publications
- Open Access
High-Performance Multilevel Inverter Integrated DVR for Comprehensive Power Quality Improvement in Power Systems
This paper proposes a dynamic voltage restorer (DVR) based on a new three-phase multilevel inverter (MLI). An integral component of DVRs is the power electronic converter. At medium-to-high voltage levels, MLIs are the ideal converters for DVR applications because lower voltage-rated switches are used to generate high voltages, thus minimizing power losses. The proposed three-phase MLI generates 15 levels of load voltage per phase, using a reduced component count: eight lower-rated semiconductor power switches, four primary DC voltage sources, two auxiliary DC sources, and eight driver circuits per phase. Additionally, each phase features a low-frequency transformer with voltage-boosting and galvanic isolation capabilities. The switching sequence of the proposed MLI is simpler to execute using fundamental frequency control; this methodology provides reduced switching stress and reduced switching losses as merits. Structurally, the proposed MLI is less complex and thus scalable. The proposed DVR, based on three-phase MLI, efficiently offsets power quality problems such as voltage swell, voltage sags, and harmonics for balanced and unbalanced loads. The operational performance of the proposed DVR-MLI is verified by a simulation, using PSCAD software and an experimental prototype.
Open AccessHigh-Performance Multilevel Inverter Integrated DVR for Comprehensive Power Quality Improvement in Power Systems
This paper proposes a dynamic voltage restorer (DVR) based on a new three-phase multilevel inverter (MLI). An integral component of DVRs is the power electronic converter. At medium-to-high voltage levels, MLIs are the ideal converters for DVR applications because lower voltage-rated switches are used to generate high voltages, thus minimizing power losses. The proposed three-phase MLI generates 15 levels of load voltage per phase, using a reduced component count: eight lower-rated semiconductor power switches, four primary DC voltage sources, two auxiliary DC sources, and eight driver circuits per phase. Additionally, each phase features a low-frequency transformer with voltage-boosting and galvanic isolation capabilities. The switching sequence of the proposed MLI is simpler to execute using fundamental frequency control; this methodology provides reduced switching stress and reduced switching losses as merits. Structurally, the proposed MLI is less complex and thus scalable. The proposed DVR, based on three-phase MLI, efficiently offsets power quality problems such as voltage swell, voltage sags, and harmonics for balanced and unbalanced loads. The operational performance of the proposed DVR-MLI is verified by a simulation, using PSCAD software and an experimental prototype.
- Open Access
- 19 December 2023
- Published by MDPI AG in Preprints.org
Cascaded Three-Phase Multilevel Inverter with Minimal Components for Power System Applications
This paper proposes a new cascaded three-phase multilevel inverter based on a cascaded submultilevel and single-phase H-bridge structure. The voltage source of the traditional single-phase H-bridge is replaced with the proposed cascaded submultilevel. Cascading two basic units forms the submultilevel unit. The basic and submultilevel units generate positive voltage only hence the need for an H-bridge to generate both polarities of load voltage. Five algorithms of source voltage are proposed and the optimal algorithm selected to generate the peak load voltage and output levels. The proposed three-phase cascaded multilevel inverter generates 31-level of load voltage. The per-phase component distribution of the proffered inverter are twelve power switches, four dc sources and twelve driver circuits accordingly. Principal merits of the proposed 31-level inverter are high quality load waveforms, production of high levels of load voltage utilizing reduced component quantity, simple cascaded layout, decreased inverter area, minimal inverter cost, minimum inverter losses and utilizing lower rated switches. Also, the proposed topology is highly suited for employment in PV-DVR and other power systems. To validate these advantages of the proposed multilevel inverter, contrastive analysis of the proposed inverter and existing topologies are studied. Finally, the functionality of the proposed inverter is substantiated by simulation in PSCAD/ EMTDC software.
- 19 December 2023
- Published by MDPI AG in Preprints.org
Open AccessCascaded Three-Phase Multilevel Inverter with Minimal Components for Power System Applications
This paper proposes a new cascaded three-phase multilevel inverter based on a cascaded submultilevel and single-phase H-bridge structure. The voltage source of the traditional single-phase H-bridge is replaced with the proposed cascaded submultilevel. Cascading two basic units forms the submultilevel unit. The basic and submultilevel units generate positive voltage only hence the need for an H-bridge to generate both polarities of load voltage. Five algorithms of source voltage are proposed and the optimal algorithm selected to generate the peak load voltage and output levels. The proposed three-phase cascaded multilevel inverter generates 31-level of load voltage. The per-phase component distribution of the proffered inverter are twelve power switches, four dc sources and twelve driver circuits accordingly. Principal merits of the proposed 31-level inverter are high quality load waveforms, production of high levels of load voltage utilizing reduced component quantity, simple cascaded layout, decreased inverter area, minimal inverter cost, minimum inverter losses and utilizing lower rated switches. Also, the proposed topology is highly suited for employment in PV-DVR and other power systems. To validate these advantages of the proposed multilevel inverter, contrastive analysis of the proposed inverter and existing topologies are studied. Finally, the functionality of the proposed inverter is substantiated by simulation in PSCAD/ EMTDC software.
- Open Access
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 2237-2247
Performance Evaluation and Viability Studies of Photovoltaic Power Plants in North Cyprus
Generating electric power by photovoltaic systems largely depends on multiple factors such as weather condition, panel orientation, panel efficiency, inverter efficiency, etc. These factors directly affect the magnitude of the PV output power. The first grid-tied photovoltaic power plant in Northern Cyprus is the K?b-Tek solar panel station located in Serhatkoy with a capacity of 1.275 MW. The aim of this paper is to comprehensively investigate K?b-Tek solar panel station considering investment made, plant efficiency, performance ratio, capacity factor and also determine the potential impact on levels of output power when a single axis solar tracking system is incorporated into the plant design. K?b-Tek solar panel station is at a fixed tilt angle of 24.840. Furthermore, other locations such as Famagusta, Girne and Lefkosa are investigated by simulation to determine their viability/suitability for the construction of similar photovoltaic power plants. The simulations are done using the technical parameters of K?b-Tek solar panel station as a model. Simulation results for these three locations are validated by comparing the magnitude of power produced by the actual plant (K?b-Tek solar panel station) and the simulated plants. PVsyst software is used for the simulation. Finally, the payback period of the actual plant and the simulated plants are determined.
- 1 January 2022
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 12 (V12i4) , 2237-2247
Open AccessPerformance Evaluation and Viability Studies of Photovoltaic Power Plants in North Cyprus
Generating electric power by photovoltaic systems largely depends on multiple factors such as weather condition, panel orientation, panel efficiency, inverter efficiency, etc. These factors directly affect the magnitude of the PV output power. The first grid-tied photovoltaic power plant in Northern Cyprus is the K?b-Tek solar panel station located in Serhatkoy with a capacity of 1.275 MW. The aim of this paper is to comprehensively investigate K?b-Tek solar panel station considering investment made, plant efficiency, performance ratio, capacity factor and also determine the potential impact on levels of output power when a single axis solar tracking system is incorporated into the plant design. K?b-Tek solar panel station is at a fixed tilt angle of 24.840. Furthermore, other locations such as Famagusta, Girne and Lefkosa are investigated by simulation to determine their viability/suitability for the construction of similar photovoltaic power plants. The simulations are done using the technical parameters of K?b-Tek solar panel station as a model. Simulation results for these three locations are validated by comparing the magnitude of power produced by the actual plant (K?b-Tek solar panel station) and the simulated plants. PVsyst software is used for the simulation. Finally, the payback period of the actual plant and the simulated plants are determined.
- 28 July 2016
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 53 (4) , 331-340
Design of two experimental setups for programmable logic controller (PLC) laboratory
As programmable logic controllers (PLC) technology, programming languages and communication capabilities have advanced, PLCs offer many control devices to be attached directly to the PLC. For this reason PLC education became an important issue in many interdisciplinary engineering departments of the Universities. In this paper an automation set for the laboratory of PLC is developed which can be operated in various ways by programming a PLC as desired. The designed set also enables the students to understand the operation principle of an elevator. This developed educational laboratory set can be used as a practice for sensors and actuators, control systems and industrial automation courses. The laboratory tool also provides a method to improve learning outcomes, skills and the real-time experiences in engineering education such as electrical, electronics, mechatronics and control engineering.
- 28 July 2016
- Published by SAGE Publications in International Journal of Electrical Engineering & Education
- Vol. 53 (4) , 331-340
Design of two experimental setups for programmable logic controller (PLC) laboratory
As programmable logic controllers (PLC) technology, programming languages and communication capabilities have advanced, PLCs offer many control devices to be attached directly to the PLC. For this reason PLC education became an important issue in many interdisciplinary engineering departments of the Universities. In this paper an automation set for the laboratory of PLC is developed which can be operated in various ways by programming a PLC as desired. The designed set also enables the students to understand the operation principle of an elevator. This developed educational laboratory set can be used as a practice for sensors and actuators, control systems and industrial automation courses. The laboratory tool also provides a method to improve learning outcomes, skills and the real-time experiences in engineering education such as electrical, electronics, mechatronics and control engineering.
- Open Access
- 1 July 2014
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 7 (7) , 1895-1905
Real‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter
In this paper, an alternative control method is proposed to improve the harmonic suppression efficiency of the active power filter in a distorted and an unbalanced power system to compensate for the perturbations caused by the unbalanced non‐linear loads. The proposed method uses a self‐tuning filter (STF) to process the grid voltage in order to provide a uniform reference voltage to obtain the correct angular position of the phase locked loop. Moreover, the required compensation currents are obtained by implementing another STF in the transformed set of currents in order to separate the fundamental and the harmonic currents. This allows the calculation of a precise reference current for the unbalanced, the non‐linear and the variable load conditions. The proposed control method gives an adequate compensating current reference even for a non‐ideal voltage and unbalanced current conditions. The real‐time control of the filter under the distorted and the unbalanced power system is developed in an RT‐LAB real‐time platform. The results obtained in the software‐in‐the‐loop configuration are presented to verify the effectiveness of the proposed control technique.
- 1 July 2014
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 7 (7) , 1895-1905
Open AccessReal‐time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self‐tuning filter
In this paper, an alternative control method is proposed to improve the harmonic suppression efficiency of the active power filter in a distorted and an unbalanced power system to compensate for the perturbations caused by the unbalanced non‐linear loads. The proposed method uses a self‐tuning filter (STF) to process the grid voltage in order to provide a uniform reference voltage to obtain the correct angular position of the phase locked loop. Moreover, the required compensation currents are obtained by implementing another STF in the transformed set of currents in order to separate the fundamental and the harmonic currents. This allows the calculation of a precise reference current for the unbalanced, the non‐linear and the variable load conditions. The proposed control method gives an adequate compensating current reference even for a non‐ideal voltage and unbalanced current conditions. The real‐time control of the filter under the distorted and the unbalanced power system is developed in an RT‐LAB real‐time platform. The results obtained in the software‐in‐the‐loop configuration are presented to verify the effectiveness of the proposed control technique.