Jia Qian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jia Qian has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Baoli Yao
Xi'an Institute of Optics and Precision Mechanics
6 shared publications - Dan Dan
State Key Laboratory of Ultrafast Optical Science and Technology, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, People’s Republic of China
5 shared publications - Xing Li
State Key Laboratory of Ultrafast Optical Science and Technology, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences 1 , Xi’an 710119
4 shared publications - Chen Bai
State Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics Chinese Academy of Sciences Xi'an China
2 shared publications - Wang Ma
State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
2 shared publications - Bin Zhang
Institute of Automation, Chinese Academy of Sciences
1 shared publication
Latest Publications
- Open Access
- 4 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (27) , eadx3900
Optical tweeze-sectioning microscopy for 3D imaging and manipulation of suspended cells
Optical manipulation and detection of biological particulates are crucial procedures in biophotonics. Optical sectioning (OS) opens the avenue to three-dimensional (3D) microscopy, but nonoptical approaches, including sample adhesion and mechanical scanning, have always been required in this technique, rendering it impossible to image suspended cells. Here, we develop optical tweeze-sectioning microscopy by coupling structured illumination microscopy (SIM) with holographic optical tweezers (HOTs). By sculpting light in HOTs, we demonstrate that the position fluctuations of suspended yeast cells can be optically squeezed to tens of nanometers, which is sufficient for the implementation of OS with SIM. Sample scanning is achieved through optical delivery of the cells, instead of translation stages as in the conventional way. Our work presents an all-optical solution for OS, broadening its application to nonadherent, suspended cells. It further furnishes the original technique that enables both SIM-based 3D imaging and optical manipulation.
- 4 July 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (27) , eadx3900
Open AccessOptical tweeze-sectioning microscopy for 3D imaging and manipulation of suspended cells
Optical manipulation and detection of biological particulates are crucial procedures in biophotonics. Optical sectioning (OS) opens the avenue to three-dimensional (3D) microscopy, but nonoptical approaches, including sample adhesion and mechanical scanning, have always been required in this technique, rendering it impossible to image suspended cells. Here, we develop optical tweeze-sectioning microscopy by coupling structured illumination microscopy (SIM) with holographic optical tweezers (HOTs). By sculpting light in HOTs, we demonstrate that the position fluctuations of suspended yeast cells can be optically squeezed to tens of nanometers, which is sufficient for the implementation of OS with SIM. Sample scanning is achieved through optical delivery of the cells, instead of translation stages as in the conventional way. Our work presents an all-optical solution for OS, broadening its application to nonadherent, suspended cells. It further furnishes the original technique that enables both SIM-based 3D imaging and optical manipulation.
- 17 March 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 189
Proof of the equivalence between two-frame and three-frame optical sectioning structured illumination microscopy
- 17 March 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 189
Proof of the equivalence between two-frame and three-frame optical sectioning structured illumination microscopy
- 9 August 2024
- Published by Elsevier in Optics & Laser Technology
- Vol. 180
Deep full-color optically-sectioned microscopy with multi-reference colorization
- 9 August 2024
- Published by Elsevier in Optics & Laser Technology
- Vol. 180
Deep full-color optically-sectioned microscopy with multi-reference colorization
- Open Access
High Fidelity Full-Color Optical Sectioning Structured Illumination Microscopy by Fourier Domain Based Reconstruction
The natural color of biological specimens plays a crucial role in body protection, signaling, physiological adaptations, etc. Full-color optical sectioning structured illumination microscopy (OS-SIM) color is a promising approach that can reconstruct biological specimens in three-dimension meanwhile maintaining their natural color. Full-color OS-SIM takes the advantages of rapid imaging speed, compatibility with fluorescence and non-fluorescence samples, compact configuration, and low cost. However, the commonly used HSV-RMS reconstruction algorithm for full-color OS-SIM faces two issues to be improved. One is the RMS (root-mean-square) OS reconstruction algorithm is prone to background noise, and the other is the reconstruction is bound in RGB and HSV color spaces, consuming more reconstructing time. In this paper, we propose a full-color Fourier-OS-SIM method that allows for the OS reconstruction using the high-frequency spectrum of the sample and thus is immune to the low-frequency background noise. The full-color Fourier-OS-SIM directly runs in the RGB color space, providing an easy way to restore the color information. Simulation and experiments with various samples (pollen grains and tiny animals) demonstrate that the full-color Fourier-OS-SIM method is superior to the HSV-RMS method regarding background noise suppression. Moreover, benefiting from the background noise suppression merit, the quantitative morphological height map analysis with the full-color Fourier-OS-SIM method is more accurate. The proposed full-color Fourier-OS-SIM method is expected to find broad applications in biological and industrial fields where the 3D morphology and the color information of objects both need to be recovered.
Open AccessHigh Fidelity Full-Color Optical Sectioning Structured Illumination Microscopy by Fourier Domain Based Reconstruction
The natural color of biological specimens plays a crucial role in body protection, signaling, physiological adaptations, etc. Full-color optical sectioning structured illumination microscopy (OS-SIM) color is a promising approach that can reconstruct biological specimens in three-dimension meanwhile maintaining their natural color. Full-color OS-SIM takes the advantages of rapid imaging speed, compatibility with fluorescence and non-fluorescence samples, compact configuration, and low cost. However, the commonly used HSV-RMS reconstruction algorithm for full-color OS-SIM faces two issues to be improved. One is the RMS (root-mean-square) OS reconstruction algorithm is prone to background noise, and the other is the reconstruction is bound in RGB and HSV color spaces, consuming more reconstructing time. In this paper, we propose a full-color Fourier-OS-SIM method that allows for the OS reconstruction using the high-frequency spectrum of the sample and thus is immune to the low-frequency background noise. The full-color Fourier-OS-SIM directly runs in the RGB color space, providing an easy way to restore the color information. Simulation and experiments with various samples (pollen grains and tiny animals) demonstrate that the full-color Fourier-OS-SIM method is superior to the HSV-RMS method regarding background noise suppression. Moreover, benefiting from the background noise suppression merit, the quantitative morphological height map analysis with the full-color Fourier-OS-SIM method is more accurate. The proposed full-color Fourier-OS-SIM method is expected to find broad applications in biological and industrial fields where the 3D morphology and the color information of objects both need to be recovered.
- Open Access
Axial Resolution Enhancement of Optical Sectioning Structured Illumination Microscopy Based on Three-Beam Interference
As a branch of 3D microscopy, optical sectioning structured illumination microscopy (OS-SIM) has the advantages of fast imaging speed, weak photobleaching and phototoxicity, and flexible and compatible configuration. Although the method of using the one-dimensional periodic fringe pattern projected on the sample can remove the out-of-focus background from the in-focus signal, the axial resolution of the final reconstructed 3D image is not improved. Here, we propose a three-beam interference OS-SIM, namely TBOS, instead of the common-used dual-beam interference OS-SIM (DBOS). The three-beam interference scheme has been adopted in 3D super-resolution SIM (3D-SR-SIM), where the fringe phase shifting needs to be along each of the three orientations. In contrast, TBOS applies phase shifting only in one arbitrary direction. We built a TBOS SIM microscope and performed the 3D imaging experiments with 46 nm diameter fluorescent microspheres and a mouse kidney section. The axial resolution of the 3D image obtained with TBOS was enhanced by a factor of 1.36 compared to the DBOS method, consistent with the theoretical analysis and simulation. The OS-SIM with enhanced axial resolution for 3D imaging may find a wide range of applications in the biomedical field.
Open AccessAxial Resolution Enhancement of Optical Sectioning Structured Illumination Microscopy Based on Three-Beam Interference
As a branch of 3D microscopy, optical sectioning structured illumination microscopy (OS-SIM) has the advantages of fast imaging speed, weak photobleaching and phototoxicity, and flexible and compatible configuration. Although the method of using the one-dimensional periodic fringe pattern projected on the sample can remove the out-of-focus background from the in-focus signal, the axial resolution of the final reconstructed 3D image is not improved. Here, we propose a three-beam interference OS-SIM, namely TBOS, instead of the common-used dual-beam interference OS-SIM (DBOS). The three-beam interference scheme has been adopted in 3D super-resolution SIM (3D-SR-SIM), where the fringe phase shifting needs to be along each of the three orientations. In contrast, TBOS applies phase shifting only in one arbitrary direction. We built a TBOS SIM microscope and performed the 3D imaging experiments with 46 nm diameter fluorescent microspheres and a mouse kidney section. The axial resolution of the 3D image obtained with TBOS was enhanced by a factor of 1.36 compared to the DBOS method, consistent with the theoretical analysis and simulation. The OS-SIM with enhanced axial resolution for 3D imaging may find a wide range of applications in the biomedical field.
- 1 January 2020
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 69 (12) , 128701-128701-11
Fast structured illumination three-dimensional color microscopic imaging method based on Hilbert-transform
As a wide-field microscopy, structured illumination microscopy (SIM) enables super-resolution and three-dimensional (3D) imaging. It has recently received lots of attention due to the advantages of high spatial resolution, short image recording time, and less photobleaching and phototoxicity. The SIM has found numerous important applications in time-lapse imaging of living tissues and cellular structures in the field of biomedical science. Color information is an important physical quantity describing the characteristics of living creatures and reflects the differences in its microstructure and optical property to some extent. Although HSV (hue, saturation, value) color space based structured illumination full-color 3D optical sectioning technique can recover the full color information on the surface of the samples without color distortion. However, for each optical sectioning, three raw images with fixed phase shift are required to calculate the sectioning images by the rootmean square (RMS) algorithm. This will dramatically increase the data acquisition time and data storage space, especially for a large-scaled sample that needs image stitching strategy. The image processing progress operated in HSV color space need to run the RMS algorithm three times in each channel of HSV space for every section, and transform the images between RGB (red-green-blue) space and HSV space twice. This will absolutely extend the data processing time and put forward higher requirements for computer hardware and software for data storage and processing. To this end, in this paper, a fast 3D color optical sectioning SIM algorithm based on Hilbert-transform is proposed. The Hilbert-transform has proved to be a powerful tool in digital signal and image processing and has successfully applied to the SIM. Here, only two raw images with structured illumination are needed to reconstruct a full-color optical sectioned image for each slice. This fast 3D color sectioning method has the advantage of insensitivity to phase-shift error and has better adaptability to noise, high quality color sectioning images can be obtained under the phase-shift error or noise disturbed environment. The image acquisition data are reduced by 1/3 and the color optical sectioning reconstruction time is saved by about 28%, this new method effectively improves the efficiency and speed for 3D color imaging and will bring a wider application range for SIM.
- 1 January 2020
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 69 (12) , 128701-128701-11
Fast structured illumination three-dimensional color microscopic imaging method based on Hilbert-transform
As a wide-field microscopy, structured illumination microscopy (SIM) enables super-resolution and three-dimensional (3D) imaging. It has recently received lots of attention due to the advantages of high spatial resolution, short image recording time, and less photobleaching and phototoxicity. The SIM has found numerous important applications in time-lapse imaging of living tissues and cellular structures in the field of biomedical science. Color information is an important physical quantity describing the characteristics of living creatures and reflects the differences in its microstructure and optical property to some extent. Although HSV (hue, saturation, value) color space based structured illumination full-color 3D optical sectioning technique can recover the full color information on the surface of the samples without color distortion. However, for each optical sectioning, three raw images with fixed phase shift are required to calculate the sectioning images by the rootmean square (RMS) algorithm. This will dramatically increase the data acquisition time and data storage space, especially for a large-scaled sample that needs image stitching strategy. The image processing progress operated in HSV color space need to run the RMS algorithm three times in each channel of HSV space for every section, and transform the images between RGB (red-green-blue) space and HSV space twice. This will absolutely extend the data processing time and put forward higher requirements for computer hardware and software for data storage and processing. To this end, in this paper, a fast 3D color optical sectioning SIM algorithm based on Hilbert-transform is proposed. The Hilbert-transform has proved to be a powerful tool in digital signal and image processing and has successfully applied to the SIM. Here, only two raw images with structured illumination are needed to reconstruct a full-color optical sectioned image for each slice. This fast 3D color sectioning method has the advantage of insensitivity to phase-shift error and has better adaptability to noise, high quality color sectioning images can be obtained under the phase-shift error or noise disturbed environment. The image acquisition data are reduced by 1/3 and the color optical sectioning reconstruction time is saved by about 28%, this new method effectively improves the efficiency and speed for 3D color imaging and will bring a wider application range for SIM.
- 1 May 2017
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 48 (1) , 1585-1588
P‐89: Analysis of Mura related to Aperture Ratio Non‐uniformity from Pixel Design
The larger BM width are needed to cover PI scratching due to poster spacer moved by large external force, and so, the issue of brightness non‐uniformity issue caused by aperture differences between non‐PS located pixels and PS‐located pixels easily appeared in the gray pattern. In this paper, we studied Mura mechanism; how to related the aperture ratio difference, pixel size, PS distribution and degree of seriousness of Mura based on contrast sensitivity value (=1/contrast value), cycles per degree (cpd). From several experimental test, we could find that cpd and 1/contrast value are the critical factor when determining the safe direction to prevent the PS‐related Mura.
- 1 May 2017
- Published by Wiley in SID Symposium Digest of Technical Papers
- Vol. 48 (1) , 1585-1588
P‐89: Analysis of Mura related to Aperture Ratio Non‐uniformity from Pixel Design
The larger BM width are needed to cover PI scratching due to poster spacer moved by large external force, and so, the issue of brightness non‐uniformity issue caused by aperture differences between non‐PS located pixels and PS‐located pixels easily appeared in the gray pattern. In this paper, we studied Mura mechanism; how to related the aperture ratio difference, pixel size, PS distribution and degree of seriousness of Mura based on contrast sensitivity value (=1/contrast value), cycles per degree (cpd). From several experimental test, we could find that cpd and 1/contrast value are the critical factor when determining the safe direction to prevent the PS‐related Mura.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A 0.13μm 64Mb HfOx ReRAM using configurable ramped voltage write and low read-disturb sensing techniques for reliability improvement
This paper presents a 0.13μm 64Mb HfO x ReRAM for embedded storage in IoT device. The configurable ramped voltage write and low read-disturb sensing techniques are proposed to address the reliability challenges in ReRAM. Experimental results show that, the ReRAM chip achieves more than 107 cycles' endurance and 10 years' retention at 75°C. In addition, its full function and superior random write performance are demonstrated on a developed evaluation board.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A 0.13μm 64Mb HfOx ReRAM using configurable ramped voltage write and low read-disturb sensing techniques for reliability improvement
This paper presents a 0.13μm 64Mb HfO x ReRAM for embedded storage in IoT device. The configurable ramped voltage write and low read-disturb sensing techniques are proposed to address the reliability challenges in ReRAM. Experimental results show that, the ReRAM chip achieves more than 107 cycles' endurance and 10 years' retention at 75°C. In addition, its full function and superior random write performance are demonstrated on a developed evaluation board.