Hélène Fleurbaey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hélène Fleurbaey has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Alain Campargue
Univ. Grenoble Alpes CNRS LIPhy 38000 Grenoble France
8 shared publications - Samir Kassi
Univ. Grenoble Alpes, CNRS, LIPhy, Grenoble, France
5 shared publications - Didier Mondelain
University Grenoble Alpes, CNRS, LIPhy , Grenoble
3 shared publications - Erin M. Adkins
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publications - Joseph T. Hodges
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publications - Aleksandra O. Koroleva
A. V. Gaponov-Grekhov Institute of Applied Physics of the Russian Academy of Sciences, 46 Ulyanov Street, Nizhny Novgorod 603950, Russia
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (35) , 21511-21523
Difference-frequency spectroscopy of water in the 600–1300 GHz region
Beyond-Voigt line profiles of water vapour were revealed using a highly accurate difference-frequency THz spectrometer and rigorous standing-wave modeling.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 28 (35) , 21511-21523
Open AccessDifference-frequency spectroscopy of water in the 600–1300 GHz region
Beyond-Voigt line profiles of water vapour were revealed using a highly accurate difference-frequency THz spectrometer and rigorous standing-wave modeling.
- 6 January 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (1)
Density dependence of measured line intensities for O2 transitions
We report predictions and measurements of O2 absorption spectra that exhibit line intensity depletion with increasing gas density. This effect, which is attributed to the finite duration of collisions, alters the line shape by redistributing a portion of the intensity from a relatively narrow spectrum that can be described by an impact-approximation-based profile to a broad pedestal with a width that is inversely related to the collision duration. Using classical molecular dynamics simulations (CMDS), we predicted details regarding this mechanism for O2 with four collision partners: O2, N2, Ar, and He at a temperature of 296 K. These simulations were validated by comparisons with experimental intensity depletion coefficients obtained from absorption spectra of the 1.27 μm band of O2 in air; Ar and He acquired over a wide pressure range up to 120 kPa. All experimental spectra were recorded using high-precision cavity ring-down spectroscopy (CRDS) apparatuses at NIST (United States of America) and LIPhy (France). For air-broadened O2, more specifically, a mean depletion value of ∼0.3% amagat−1 was observed, with almost no resolvable rotational dependence. The temperature dependence of the intensity depletion in this system was also investigated by CMDS at 250 and 296 K and by CRDS spectra of air at 250, 275, and 296 K. The theoretical results suggest a nearly 1/T2 temperature dependence of the intensity-weighted depletion coefficient, which over the limited temperature range considered, was only slightly greater than the measurement precision. Finally, simulations of atmospheric solar absorption spectra were implemented to quantify the impact of neglecting this depletion effect on the retrieved surface pressure, resulting in a negatively biased measurement of ∼0.14%, with a spread of ∼0.02% caused by seasonal variations in gas temperature.
- 6 January 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (1)
Density dependence of measured line intensities for O2 transitions
We report predictions and measurements of O2 absorption spectra that exhibit line intensity depletion with increasing gas density. This effect, which is attributed to the finite duration of collisions, alters the line shape by redistributing a portion of the intensity from a relatively narrow spectrum that can be described by an impact-approximation-based profile to a broad pedestal with a width that is inversely related to the collision duration. Using classical molecular dynamics simulations (CMDS), we predicted details regarding this mechanism for O2 with four collision partners: O2, N2, Ar, and He at a temperature of 296 K. These simulations were validated by comparisons with experimental intensity depletion coefficients obtained from absorption spectra of the 1.27 μm band of O2 in air; Ar and He acquired over a wide pressure range up to 120 kPa. All experimental spectra were recorded using high-precision cavity ring-down spectroscopy (CRDS) apparatuses at NIST (United States of America) and LIPhy (France). For air-broadened O2, more specifically, a mean depletion value of ∼0.3% amagat−1 was observed, with almost no resolvable rotational dependence. The temperature dependence of the intensity depletion in this system was also investigated by CMDS at 250 and 296 K and by CRDS spectra of air at 250, 275, and 296 K. The theoretical results suggest a nearly 1/T2 temperature dependence of the intensity-weighted depletion coefficient, which over the limited temperature range considered, was only slightly greater than the measurement precision. Finally, simulations of atmospheric solar absorption spectra were implemented to quantify the impact of neglecting this depletion effect on the retrieved surface pressure, resulting in a negatively biased measurement of ∼0.14%, with a spread of ∼0.02% caused by seasonal variations in gas temperature.
- Open Access
- 24 July 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (33) , 21974-21981
Room temperature detection of the (H2)2 dimer
The absorption spectrum of the hydrogen dimer, (H2)2, is detected at room temperature while from its bond dissociation energy of only about 3 cm−1 (∼4.5 K), such a detection was unexpected.
- 24 July 2024
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 26 (33) , 21974-21981
Open AccessRoom temperature detection of the (H2)2 dimer
The absorption spectrum of the hydrogen dimer, (H2)2, is detected at room temperature while from its bond dissociation energy of only about 3 cm−1 (∼4.5 K), such a detection was unexpected.
- 6 March 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 160 (9)
First detection and absolute transition frequencies in the (3–0) band of D2
Three electric quadrupole transitions in the second overtone band of D2 are newly measured by comb-referenced cavity ring down spectroscopy around 1.18 µm. These extremely weak transitions (line intensities smaller than 10−29 cm/molecule) are the first to be detected in the (3–0) band of D2. The spectra of the O(3), O(2), and Q(2) lines near 8321, 8446, and 8607 cm−1, respectively, are recorded at room temperature for pressure values ranging between 100 and 600 Torr. Accurate transition frequencies and line intensities of the three D2 transitions are determined from a line fitting procedure using beyond-Voigt profiles, including strong Dicke narrowing. Considering statistical fit errors and possible biases due to the interference with water lines (which are six orders of magnitude stronger than the studied D2 lines), total uncertainties on the frequencies extrapolated at zero pressure are estimated below 14 MHz (∼4.7 × 10−4 cm−1). The derived experimental frequencies and intensities are compared to ab initio values. An overall agreement is achieved, confirming the positional accuracy of the most advanced theoretical calculations.
- 6 March 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 160 (9)
First detection and absolute transition frequencies in the (3–0) band of D2
Three electric quadrupole transitions in the second overtone band of D2 are newly measured by comb-referenced cavity ring down spectroscopy around 1.18 µm. These extremely weak transitions (line intensities smaller than 10−29 cm/molecule) are the first to be detected in the (3–0) band of D2. The spectra of the O(3), O(2), and Q(2) lines near 8321, 8446, and 8607 cm−1, respectively, are recorded at room temperature for pressure values ranging between 100 and 600 Torr. Accurate transition frequencies and line intensities of the three D2 transitions are determined from a line fitting procedure using beyond-Voigt profiles, including strong Dicke narrowing. Considering statistical fit errors and possible biases due to the interference with water lines (which are six orders of magnitude stronger than the studied D2 lines), total uncertainties on the frequencies extrapolated at zero pressure are estimated below 14 MHz (∼4.7 × 10−4 cm−1). The derived experimental frequencies and intensities are compared to ab initio values. An overall agreement is achieved, confirming the positional accuracy of the most advanced theoretical calculations.
- Open Access
- 16 August 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (34) , 22662-22668
Accurate absolute frequency measurement of the S(2) transition in the fundamental band of H2 near 2.03 μm
A comb-referenced CRDS spectrometer is used to measure the absolute frequency of the S(2) transition in the fundamental band of H2 with a 150 kHz uncertainty.
- 16 August 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (34) , 22662-22668
Open AccessAccurate absolute frequency measurement of the S(2) transition in the fundamental band of H2 near 2.03 μm
A comb-referenced CRDS spectrometer is used to measure the absolute frequency of the S(2) transition in the fundamental band of H2 with a 150 kHz uncertainty.
- 2 May 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (21) , 14749-14756
The high-accuracy spectroscopy of H2 rovibrational transitions in the (2-0) band near 1.2 μm
Transition frequencies of six weak lines of the (2-0) vibrational band of H2 are measured with accuracy better than 100 kHz, improving the accuracy of previous measurements by three orders of magnitude.
- 2 May 2023
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 25 (21) , 14749-14756
The high-accuracy spectroscopy of H2 rovibrational transitions in the (2-0) band near 1.2 μm
Transition frequencies of six weak lines of the (2-0) vibrational band of H2 are measured with accuracy better than 100 kHz, improving the accuracy of previous measurements by three orders of magnitude.
- 12 February 2022
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 282
Characterization of the H2O+CO2 continuum within the infrared transparency windows
- 12 February 2022
- Published by Elsevier in Journal of Quantitative Spectroscopy and Radiative Transfer
- Vol. 282
Characterization of the H2O+CO2 continuum within the infrared transparency windows