Jonathan Glenday
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jonathan Glenday has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Kontaxis
Leon Root Motion Analysis Laboratory, Rehabilitation Department, Hospital for Special Surgery, New York, NY, USA
3 shared publications - Jean-Pierre du Plessis
Department of Surgery, Division of Orthopaedic Surgery, Groote Schuur Hospital, Cape Town, South Africa
2 shared publications Lawrence V. Gulotta
Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY, USA
2 shared publicationsMichael C. Fu
Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY, USA
2 shared publications- Roopam Dey
University of Cape Town, Rondebosch, South Africa
2 shared publications Samuel A. Taylor
Department of Sports Medicine and Shoulder Surgery, Hospital for Special Surgery, New York, NY, USA
2 shared publications
Latest Publications
- 28 June 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113438
Torque provides a more comprehensive assessment of reverse total shoulder arthroplasty lateralization than moment arms or muscle forces
- 28 June 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 205, 113438
Torque provides a more comprehensive assessment of reverse total shoulder arthroplasty lateralization than moment arms or muscle forces
- 13 March 2026
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (9) , 2266-2273
Source of lateralization in reverse total shoulder arthroplasty matters: a comparison of glenoid and humeral lateralization on rotator cuff biomechanics
- 13 March 2026
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (9) , 2266-2273
Source of lateralization in reverse total shoulder arthroplasty matters: a comparison of glenoid and humeral lateralization on rotator cuff biomechanics
- 24 November 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (6) , 1387-1396
Moment arms of the coracobrachialis and short head of biceps following a Latarjet procedure: a modeling study
- 24 November 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (6) , 1387-1396
Moment arms of the coracobrachialis and short head of biceps following a Latarjet procedure: a modeling study
- 8 December 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (9) , 2156-2168
Development of a framework to assess the biomechanical impact of reverse shoulder arthroplasty placement modifications
Reverse shoulder arthroplasty biomechanics can be improved by modifying the placement of prosthesis. Biomechanical studies have quantified the impact of placement modifications on the mobility and stability of the reverse shoulder. While these studies have provided detailed insights, direct comparisons between their finding are obfuscated by their use of differing methodologies. The aim of our study was to develop an assessment framework which used musculoskeletal simulations to consistently evaluate the biomechanics of various placement modifications. We conducted musculoskeletal simulations of humeral elevations and rotations using 15 reverse shoulder models. For each model, these simulations were conducted for a reference configuration of the prosthesis, established using surgical guidelines, and 34 modified configurations, which were based on commonplace adaptations to the placement of the glenosphere and humeral tray. The effect of each modified configuration on deltoid elongation, deltoid moment arm (DMA), joint stability, and impingement‐free range of motion (IFROM) was determined relative to the reference configuration. We found that 16 of the 34 modified placements had an overall beneficial impact on reverse shoulder biomechanics. Within this subset, we identified two biomechanical trade‐offs. First, there is an antagonistic relationship between IFROM and both the DMA and joint stability. Second, functional requirements differ between humeral elevations and rotations. Furthermore, we found that posteromedial translation of the humeral tray had the most beneficial impact on joint stability and inferior translation of the glenosphere had the most beneficial impact on IFROM and DMA.
- 8 December 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (9) , 2156-2168
Development of a framework to assess the biomechanical impact of reverse shoulder arthroplasty placement modifications
Reverse shoulder arthroplasty biomechanics can be improved by modifying the placement of prosthesis. Biomechanical studies have quantified the impact of placement modifications on the mobility and stability of the reverse shoulder. While these studies have provided detailed insights, direct comparisons between their finding are obfuscated by their use of differing methodologies. The aim of our study was to develop an assessment framework which used musculoskeletal simulations to consistently evaluate the biomechanics of various placement modifications. We conducted musculoskeletal simulations of humeral elevations and rotations using 15 reverse shoulder models. For each model, these simulations were conducted for a reference configuration of the prosthesis, established using surgical guidelines, and 34 modified configurations, which were based on commonplace adaptations to the placement of the glenosphere and humeral tray. The effect of each modified configuration on deltoid elongation, deltoid moment arm (DMA), joint stability, and impingement‐free range of motion (IFROM) was determined relative to the reference configuration. We found that 16 of the 34 modified placements had an overall beneficial impact on reverse shoulder biomechanics. Within this subset, we identified two biomechanical trade‐offs. First, there is an antagonistic relationship between IFROM and both the DMA and joint stability. Second, functional requirements differ between humeral elevations and rotations. Furthermore, we found that posteromedial translation of the humeral tray had the most beneficial impact on joint stability and inferior translation of the glenosphere had the most beneficial impact on IFROM and DMA.
- 7 July 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (4) , 816-825
Effect of varus alignment on the bone‐implant interaction of a cementless tibial baseplate during gait
Component alignment in total knee arthroplasty is a determining factor for implant longevity. Mechanical alignment, which provides balanced load transfer, is the most common alignment strategy. However, a retrospective review found that varus alignment, which could lead to unbalanced loading, can happen in up to 18% of tibial baseplates. This may be particularly burdensome for cementless tibial baseplates, which require low bone‐implant micromotion and avoidance of bone overload to obtain bone ingrowth. Our aim was to assess the effect of varus alignment on the bone‐implant interaction of cementless baseplates. We virtually implanted 11 patients with knee OA with a modern cementless tibial baseplate in mechanical alignment and in 2° of tibial varus alignment. We performed finite element simulations throughout gait, with loading conditions derived from literature. Throughout the stance phase, varus alignment had greater micromotion and percentage of bone volume at risk of failure than mechanical alignment. At mid‐stance, when the most critical conditions occurred, the average increase in peak micromotion and amount of bone at risk of failure due to varus alignment were 79% and 59%, respectively. Varus alignment also resulted in the decrease of the surface area with micromotion compatible with bone ingrowth. However, for both alignments, this surface area was larger than the average area of ingrowth reported for well‐fixed implants retrieved post‐mortem. Our findings suggest that small varus deviations from mechanical alignment can adversely impact the biomechanics of the bone‐implant interaction for cementless tibial baseplates during gait; however, the clinical implications of such changes remain unclear.
- 7 July 2021
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 40 (4) , 816-825
Effect of varus alignment on the bone‐implant interaction of a cementless tibial baseplate during gait
Component alignment in total knee arthroplasty is a determining factor for implant longevity. Mechanical alignment, which provides balanced load transfer, is the most common alignment strategy. However, a retrospective review found that varus alignment, which could lead to unbalanced loading, can happen in up to 18% of tibial baseplates. This may be particularly burdensome for cementless tibial baseplates, which require low bone‐implant micromotion and avoidance of bone overload to obtain bone ingrowth. Our aim was to assess the effect of varus alignment on the bone‐implant interaction of cementless baseplates. We virtually implanted 11 patients with knee OA with a modern cementless tibial baseplate in mechanical alignment and in 2° of tibial varus alignment. We performed finite element simulations throughout gait, with loading conditions derived from literature. Throughout the stance phase, varus alignment had greater micromotion and percentage of bone volume at risk of failure than mechanical alignment. At mid‐stance, when the most critical conditions occurred, the average increase in peak micromotion and amount of bone at risk of failure due to varus alignment were 79% and 59%, respectively. Varus alignment also resulted in the decrease of the surface area with micromotion compatible with bone ingrowth. However, for both alignments, this surface area was larger than the average area of ingrowth reported for well‐fixed implants retrieved post‐mortem. Our findings suggest that small varus deviations from mechanical alignment can adversely impact the biomechanics of the bone‐implant interaction for cementless tibial baseplates during gait; however, the clinical implications of such changes remain unclear.
- 27 December 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 24 (9) , 973-984
Development of a musculoskeletal model of the wrist to predict frictional work dissipated due to tendon gliding resistance in the carpal tunnel
Carpal tunnel syndrome is an entrapment neuropathy that has been associated with the aggravation of tendon gliding resistance due to forceful, high velocity, awkwardly angled, and repetitive wrist motions. Cadaveric and epidemiological studies have shown that combinations of these risk factors have a more than additive effect. The aim of the current study was to develop a musculoskeletal model of the wrist that could evaluate these risk factors by simulating frictional work dissipated due to the gliding resistance of the third flexor digitorum superficialis tendon. Three flexion angle zones, three extension angle zones, five levels of task repetitiveness, and five levels of task effort were derived from ergonomic standards. Of the simulations performed by systematically combining these parameters, the extreme wrist flexion zone, at peak task repetitiveness and effort, dissipated the most frictional work. This zone dissipated approximately double the amount of frictional work compared to its equivalent zone in extension. For all motions, a multiplicative effect of the combination of task repetitiveness and effort on frictional work was identified by the musculoskeletal model, corroborating previous epidemiological and experimental studies. Overall, these results suggest that the ergonomic standards for wrist flexion-extension may need to be adjusted to reflect equivalent biomechanical impact and that workplace tasks should be designed to minimise exposure to combinations of highly repetitive and highly forceful work, especially when the wrist is highly flexed.
- 27 December 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 24 (9) , 973-984
Development of a musculoskeletal model of the wrist to predict frictional work dissipated due to tendon gliding resistance in the carpal tunnel
Carpal tunnel syndrome is an entrapment neuropathy that has been associated with the aggravation of tendon gliding resistance due to forceful, high velocity, awkwardly angled, and repetitive wrist motions. Cadaveric and epidemiological studies have shown that combinations of these risk factors have a more than additive effect. The aim of the current study was to develop a musculoskeletal model of the wrist that could evaluate these risk factors by simulating frictional work dissipated due to the gliding resistance of the third flexor digitorum superficialis tendon. Three flexion angle zones, three extension angle zones, five levels of task repetitiveness, and five levels of task effort were derived from ergonomic standards. Of the simulations performed by systematically combining these parameters, the extreme wrist flexion zone, at peak task repetitiveness and effort, dissipated the most frictional work. This zone dissipated approximately double the amount of frictional work compared to its equivalent zone in extension. For all motions, a multiplicative effect of the combination of task repetitiveness and effort on frictional work was identified by the musculoskeletal model, corroborating previous epidemiological and experimental studies. Overall, these results suggest that the ergonomic standards for wrist flexion-extension may need to be adjusted to reflect equivalent biomechanical impact and that workplace tasks should be designed to minimise exposure to combinations of highly repetitive and highly forceful work, especially when the wrist is highly flexed.