MSMandeep Sharma

Mandeep Sharma

*This is an algorithmically generated author record based on publicly available information.

Mandeep Sharma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Frequency Regulation Strategy of Two-Area Microgrid System with Electric Vehicle Support Using Novel Fuzzy-Based Dual-Stage Controller and Modified Dragonfly Algorithm

    by Balvender Singh, Adam Slowik, Shree Krishan Bishnoi, Mandeep Sharma

    Energy in microgrids (MGs) can now be generated from a variety of renewable sources, but their effective and sustainable use is dependent on electrical energy storage (EES) systems. Consequently, the expansion of MGs is greatly reliant on EES systems. The high infiltration of electric vehicles (EVs) causes some problems for the smooth functioning of the electric power system. However, EVs are also able to offer ancillary services, such as energy storage, to power systems. The research presented in this paper aims to develop a novel frequency regulation (FR) approach for biogas diesel engines (wind), the organic Rankine cycle (ORC), and solar-based two-area islanded microgrids with EVs in both areas. This article discusses the introduction of a fuzzy logic controller (FLC) for FR with scaled factors configured as proportional integral (PI) and proportional derivative with filter (PDF), i.e., a FLC-SF-PI-PDF controller. A recently created modified dragonfly algorithm is used to determine the best values for the controller parameters. To justify the effectiveness of the proposed controller with the presence of EVs, the execution of the proposed controller is associated with and without the presence of EVs. This research also looks at the different uncertain conditions, non-linearities, and eigenvalue stability analysis to validate the supremacy of the proposed approach.


  • Robust Load Frequency Control Using Fractional-order TID-PD Approach Via Salp Swarm Algorithm

    by Mandeep Sharma, Surya Prakash, Sahaj Saxena

    To preserve frequency and tie-line power flow within a tolerable range in modern intricate and renewable energy sources (RES) integrated power system, an intelligent, expert, and robust load frequency control (LFC) scheme is requisite. This paper proposes a new load frequency control (LFC) approach using a dual-stage controller composed of fractional-order tilted-integral-derivative (TID) and integer-order proportional-derivative (PD) controllers. The recently developed salp swarm algorithm has tuned the parameters of the controller. The proposed scheme exhibits robustness and fast disturbance rejection performance because the tilted-integral-derivative controller is structured in a fractional-order framework, and transient response is improved due to the proportional-derivative controller. The overall activity of the LFC has been further upgraded by incorporating the flexible AC transmission system (FACTS) device namely thyristor-controlled phase shifter (TCPS) unit and energy storage system called redox flow battery (RFB) units. The proposed control approach is applied to diverse types of multi-area multi-source power systems with thermal, hydro, and wind turbine units along with nonlinear functions namely generation rate constraint (GRC), governor dead band (GDB), and communication delay (CD). The simulation results yield improved frequency regulation activity with and without TCPS and RFB using the proposed control approach when compared with the recently developed LFC approaches. Sensitivity analysis also established the robustness of the proposed control approach.


  • Top Cited Papers
    Open Access

    Cascade‐I λ D μ N controller design for AGC of thermal and hydro‐thermal power systems integrated with renewable energy sources

    by Yogendra Arya, Nishant Kumar, Pankaj Dahiya, Gulshan Sharma, Emre Çelik, Sandeep Dhundhara, Mandeep Sharma

    Expert, intelligent and robust automatic generation control (AGC) scheme is requisite for stable operation and control of power system (PS) integrated with renewable energy sources (RES) under sudden/random small load disturbances. Large frequency deviations appear if AGC capacity is inept to compensate for the imbalances of generation and demand. In this paper, a cascade‐fractional order ID with filter (C‐I λ D μ N) controller is proposed as an expert supplementary controller to promote AGC recital adequately in electric power systems incorporated with RES like solar, wind and fuel cells. The imperialist competitive algorithm is fruitfully exploited for optimizing the controller parameters. First, a 2‐area reheat thermal system is examined critically and then to authorize the worth of the proposed controller, the study is protracted to a 2‐area multi‐source hydro‐thermal system. The prominent benefits of C‐I λ D μ N controller with/without renewable energy sources consist of its great indolence to large load disturbances and superiority over various optimized classical/fuzzy controllers published recently. The sensitivity study validates the robustness of the recommended controller against ±20% deviations in the system parameters and random step load perturbations.


  • Open Access

    Grasshopper optimisation based robust power/frequency regulator for shipboard micro‐grid

    by Atul Kumar Choudhary, Surya Prakash, Mandeep Sharma, Sandeep Dhundhara

    Due to the rapid increase in electrical energy requirements in marine power systems (MPSs), and to reduce the consumption of fossil fuel, there is an emergent need to utilise renewable energy sources (RESs) in MPSs, which has been an attractive field of research. This research aims to present a novel load frequency control (LFC) scheme for a shipboard micro‐grid (SMG) system. Therefore, a MPS with photovoltaic, wind turbine, hybrid energy storage system (ESS), and diesel generator (DG) have been simulated to relate an exact mobile islanded SMG. The system is designed using the transfer function models with the above said generating units and storage systems. Grasshopper optimisation algorithm (GOA) tuned fuzzy‐based proportional–integral–derivative with filter control technique has been proposed to investigate the performance of the LFC scheme for the proposed SMG system. GOA and particle swarm optimisation optimised controllers have been designed and performance evaluation has been carried out on the conventional, adaptive neuro‐fuzzy inference system, and fuzzy cascaded with a conventional controller. The responses obtained from the simulations for different cases are analysed to justify the novelty and superiority of the proposed technique for frequency and power regulation.


  • Open Access

    Frequency excursion mitigation strategy using a novel COA optimised fuzzy controller in wind integrated power systems

    by Mandeep Sharma, Sandeep Dhundhara, Yogendra Arya, Surya Prakash

    The uncertain demeanour from wind generators and loads adversely affect the grid operational stability. Various control approaches have been explored to remedy the system uncertainties while maintaining generation and load demand balance. This study proposes a fuzzy‐based proportional–fractional integral–derivative with filter controller to sustain frequency stability in wind integrated power systems having different configurations. The controller parameters have been tuned using a recently developed coyote optimisation algorithm (COA). The proposed control approach is executed and validated on three distinct configurations of two‐area power systems. All test models are integrated with a doubly fed induction generator (DFIG) type wind turbine units (WTUs). Different case scenarios have been considered to analyse the efficacy of the proposed control strategy in the presence of WTU. Furthermore, the impact of inertial support delivered by the DFIG‐WTU and higher penetration of wind energy in the power system has been studied. The analysis reveals that the control scheme in coordination with WTU support reduces the stress on a wind turbine during the inertial control scheme and maintains the grid frequency stability under unexpected load disturbances. Stability and robustness analysis are also conducted to verify the validity of the introduced control approach.


  • Optimal Fractional-Order Tilted-Integral-Derivative Controller for Frequency Stabilization in Hybrid Power System Using Salp Swarm Algorithm

    by Mandeep Sharma, Surya Prakash, Sahaj Saxena, Sandeep Dhundhara

    Regulating the frequency fluctuations (known as load frequency control) in the power system is an important aspect that directly signifies the balance between the generation and demand. The present study proposes an optimal LFC scheme encapsulating the concept of fractional-order based tilted-integral-derivative (TID) controller having optimized parameters using the recently developed optimization technique called salp swarm algorithm. The various non-linearities such as governor dead-band, generation rate constraint, and communication time delays are also considered in the power system having thermal-hydro-wind turbines generating units in both areas. Furthermore, the impact of thyristor controlled phase shifter (TCPS) and redox flow battery (RFB) has been investigated in the proposed power system. Extensive simulations for different test systems and robustness analysis with wide variation in all system parameters at a time have been executed to validate the superiority of the proposed control strategy. The effectiveness of the proposed controller has been studied by comparing system response with recently developed algorithms. The performance evaluations confirm that the proposed controller provides stable, optimal, and superior performance compared to other existing schemes. Further, obtained results strongly suggest that TCPS and RFB units stabilize the transients quickly to enhance the system frequency stability during load instabilities.


  • MVO Algorithm Based LFC Design of a Six-Area Hybrid Diverse Power System Integrating IPFC and RFB

    by Mandeep Sharma, R. K Bansal, Surya Prakash, Sajjad Asefi

    Flexible alternating current transmission system devices and energy storage devices have great potential to support frequency regulation in power system. Hence, the impact of interline power flow controller unit and redox flow battery unit in the load frequency control (LFC) of six-area power system having different power plant units has been investigated in this paper. The multi-verse optimizer (MVO) is proposed to tune the parameters of the proportional–integral and derivative (PID) controller. Further, the efficacy of the multi-verse optimizer tuned proportional–integral (PI) controller is also equated with the recently developed sine-cosine algorithm tuned PI controller in the investigated power system. The encouraging role of interline power flow controller (IPFC) unit and redox flow battery (RFB) unit has been confirmed for system frequency and tie-line power regulation. The investigation validated that multi-verse optimizer based proportional–integral–derivative controller with an interline power flow controller unit and redox flow battery unit give better dynamic response during sudden load disturbances.