Tsutomu Nakaoka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tsutomu Nakaoka has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Abu Bakar Jaafar
Razak Faculty of Technology and Informatics & UTM Ocean Thermal Energy Centre, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Malaysia
3 shared publications - Sathiabama T. Thirugnana
Razak Faculty of Technology and Informatics & UTM Ocean Thermal Energy Centre, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Malaysia
3 shared publications - Takeshi Yasunaga
Institute of Ocean Energy, Saga University, Honjo-machi 1, Saga, 840-8502, Japan
3 shared publications - Yasuyuki Ikegami
Institute of Ocean Energy, Saga University, 1-Honjo Machi, Saga-shi, Saga 840-8502, Japan
3 shared publications - Ahmad Aiman Azmi
UTM OTEC Universiti Teknologi Malaysia Kuala Lumpur Malaysia
2 shared publications - Hariharan Jai Karthikeyan
Razak Faculty of Technology and Informatics & UTM Ocean Thermal Energy Centre, Universiti Teknologi Malaysia, Kuala Lumpur 54100, Malaysia
1 shared publication
Latest Publications
- Open Access
- 8 February 2024
- Published by Springer Nature in Journal of Marine Science and Technology
- Vol. 29 (2) , 333-352
Basic design optimization of power and desalinated water for hybrid cycle ocean thermal energy conversion system integrated with desalination plant
Ocean thermal energy conversion (OTEC) is a heat engine application that utilizes the Rankine cycle to extract energy from the thermal gradient between surface seawater and deep seawater. Hybrid cycle OTEC (H-OTEC) is a combination of an open cycle desalination system and a closed-cycle power generation system that leverages the features of both cycles. Unlike other desalination technologies that require extensive energy to operate, H-OTEC relies entirely on renewable energy. In addition, a desalination plant can be coupled with the H-OTEC system (H-OTEC + D) to improve its performance. Conventionally, the total heat transfer area of heat exchangers per net power is used as an objective function to achieve optimal performance with the lowest capital expenditure cost. The proposed objective function, unlike the conventional one, considers both power and water. In this study, the optimization of H-OTEC + D and H-OTEC is carried out by minimizing the proposed objective function, considering several independent variables. The performance of both systems is evaluated in terms of the objective function, power consumption, seawater flow rates, and desalination ratio. The findings also indicate the effectiveness of the proposed objective function over the conventional one as an effective tool for maximizing power and desalinated water generation.
- 8 February 2024
- Published by Springer Nature in Journal of Marine Science and Technology
- Vol. 29 (2) , 333-352
Open AccessBasic design optimization of power and desalinated water for hybrid cycle ocean thermal energy conversion system integrated with desalination plant
Ocean thermal energy conversion (OTEC) is a heat engine application that utilizes the Rankine cycle to extract energy from the thermal gradient between surface seawater and deep seawater. Hybrid cycle OTEC (H-OTEC) is a combination of an open cycle desalination system and a closed-cycle power generation system that leverages the features of both cycles. Unlike other desalination technologies that require extensive energy to operate, H-OTEC relies entirely on renewable energy. In addition, a desalination plant can be coupled with the H-OTEC system (H-OTEC + D) to improve its performance. Conventionally, the total heat transfer area of heat exchangers per net power is used as an objective function to achieve optimal performance with the lowest capital expenditure cost. The proposed objective function, unlike the conventional one, considers both power and water. In this study, the optimization of H-OTEC + D and H-OTEC is carried out by minimizing the proposed objective function, considering several independent variables. The performance of both systems is evaluated in terms of the objective function, power consumption, seawater flow rates, and desalination ratio. The findings also indicate the effectiveness of the proposed objective function over the conventional one as an effective tool for maximizing power and desalinated water generation.
- Open Access
- 18 February 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (4) , 3777
Performance Analysis of a 10 MW Ocean Thermal Energy Conversion Plant Using Rankine Cycle in Malaysia
Ocean thermal energy conversion (OTEC) is a solution for environmental and climate change issues in the tropics. The OTEC potential in Malaysia using ocean conditions and bathymetry data has been previously studied and demonstrated. Following this, it is vital to perform a basic performance analysis of a 10 MW Rankine Cycle OTEC plant using the Malaysian ocean conditions. In this paper, the results of heat and mass balance will be reported for a 10 MW Rankine cycle OTEC plant which uses heat exchangers of plate-type and anhydrous ammonia as its working fluid. The value of a minimum objective function (γ) is derived by total heat surface area (AT) divided by the net power (PN). γ decreases when the inlet temperature difference (inlet temperature of warm seawater (TWSWI)—inlet temperature of cold seawater (TCSWI)) increases. PN is clarified to be approximately 70–80% of the PG (gross power) using Malaysian ocean conditions.
- 18 February 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (4) , 3777
Open AccessPerformance Analysis of a 10 MW Ocean Thermal Energy Conversion Plant Using Rankine Cycle in Malaysia
Ocean thermal energy conversion (OTEC) is a solution for environmental and climate change issues in the tropics. The OTEC potential in Malaysia using ocean conditions and bathymetry data has been previously studied and demonstrated. Following this, it is vital to perform a basic performance analysis of a 10 MW Rankine Cycle OTEC plant using the Malaysian ocean conditions. In this paper, the results of heat and mass balance will be reported for a 10 MW Rankine cycle OTEC plant which uses heat exchangers of plate-type and anhydrous ammonia as its working fluid. The value of a minimum objective function (γ) is derived by total heat surface area (AT) divided by the net power (PN). γ decreases when the inlet temperature difference (inlet temperature of warm seawater (TWSWI)—inlet temperature of cold seawater (TCSWI)) increases. PN is clarified to be approximately 70–80% of the PG (gross power) using Malaysian ocean conditions.
- Open Access
- 28 December 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (1) , 22
Estimation of Ocean Thermal Energy Conversion Resources in the East of Malaysia
The Malaysian Government has set a target of achieving 20% penetration of Renewable Energy (RE) in the energy mix spectrum by 2025. In order to get closer to the target, Ocean Thermal Energy Conversion (OTEC) aligned with solar PV, biogas and biomass energy sources must be evaluated and comprehended. Hybrid OTEC systems consisting of energy and water production are currently under research and validation. Therefore, for the construction of a commercial OTEC plant, 1 MW or 2.5 MW, the choice of a strategic location or potential site is vital. In this paper, oceanographic data such as seawater temperature, depth, salinity and dissolved oxygen obtained from the Japan Oceanographic Data Center (JODC) for Semporna, Tawau, Kudat, Pulau Layang-Layang and Pulau Kalumpang in Sabah, Malaysia, are reported. The RE available from the Exclusive Economic Zone (EEZ) on the coast of Sabah was estimated based on the JODC data obtained. There were no remarkable differences in temperatures between the five sites, which were reported as approximately 27 °C at the surface and 7 °C at depths below 600 m. The surface salinities below 100 m at those sites were slightly lower than the deeper waters, where the salinity increased up to approximately 34.5 PSU. Dissolved oxygen data from the Pulau Kalumpang site showed a slight increment to approximately 4.7 mL/L at depth intervals below 50 m, before declining steadily to approximately 1.7 mL/L along with the depth. The temperature-salinity profiles of the Malaysian sites were congruent with those of Palau, Kumejima and Okinawa, but not with that of Fiji, where the salinity profile showed a distinct variation at the relative depth (below 200 m). Estimates of RE using two different methods were used to prove the potential of OTEC in Malaysia.
- 28 December 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (1) , 22
Open AccessEstimation of Ocean Thermal Energy Conversion Resources in the East of Malaysia
The Malaysian Government has set a target of achieving 20% penetration of Renewable Energy (RE) in the energy mix spectrum by 2025. In order to get closer to the target, Ocean Thermal Energy Conversion (OTEC) aligned with solar PV, biogas and biomass energy sources must be evaluated and comprehended. Hybrid OTEC systems consisting of energy and water production are currently under research and validation. Therefore, for the construction of a commercial OTEC plant, 1 MW or 2.5 MW, the choice of a strategic location or potential site is vital. In this paper, oceanographic data such as seawater temperature, depth, salinity and dissolved oxygen obtained from the Japan Oceanographic Data Center (JODC) for Semporna, Tawau, Kudat, Pulau Layang-Layang and Pulau Kalumpang in Sabah, Malaysia, are reported. The RE available from the Exclusive Economic Zone (EEZ) on the coast of Sabah was estimated based on the JODC data obtained. There were no remarkable differences in temperatures between the five sites, which were reported as approximately 27 °C at the surface and 7 °C at depths below 600 m. The surface salinities below 100 m at those sites were slightly lower than the deeper waters, where the salinity increased up to approximately 34.5 PSU. Dissolved oxygen data from the Pulau Kalumpang site showed a slight increment to approximately 4.7 mL/L at depth intervals below 50 m, before declining steadily to approximately 1.7 mL/L along with the depth. The temperature-salinity profiles of the Malaysian sites were congruent with those of Palau, Kumejima and Okinawa, but not with that of Fiji, where the salinity profile showed a distinct variation at the relative depth (below 200 m). Estimates of RE using two different methods were used to prove the potential of OTEC in Malaysia.