Jesus Elias Miranda Vega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jesus Elias Miranda Vega has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Wendy Flores-Fuentes
Facultad de Ingeniería, Universidad Autónoma de Baja California, Calle Normal s/n Blvd. Benito Juárez Col. Insurgentes Este, Parcela 44, Mexicali 21100, Baja California, Mexico
24 shared publications - Oleg Sergiyenko
Autonomous University of Baja California, Mexicali, Mexico
21 shared publications - Julio Cesar Rodriguez Quiñonez
Universidad Autónoma de Baja California
19 shared publications - Daniel Hernandez-Balbuena
Universidad Autónoma de Baja California
7 shared publications - Wendy Garcia-Gonzalez
Universidad Autónoma de Baja California
6 shared publications - Lars Lindner
Universidad Autónoma de Baja California, México
5 shared publications
Latest Publications
- 10 October 2026
- Published by Cientifica, Revista Mexicana de Ingenieria Electromecanica y de Sistemas, IPN
- Vol. 30 (2) , 1-16
Low‑Cost Embedded System for Real‑Time Acquisition and Visualization of Photoplethysmographic Signals Using ESP32‑S3, BLE, and MAX30102
This paper presents a low-cost real-time photoplethysmography (PPG) monitoring platform based on an ESP32-S3 SuperMini, a MAX30102 sensor operating at 200 samples per second, and a desktop graphical user interface (GUI). The proposed system establishes Bluetooth Low Energy (BLE) communication between the embedded node and the PC interface to stream both infrared (IR) and red (RED) channels simultaneously. On the embedded side, the firmware acquires, packages, and transmits the raw PPG signals while estimating the heart rate in beats per minute (BPM) for each channel. On the desktop side, the GUI displays the received signals and the corresponding BPM values in real time, providing a practical and accessible monitoring environment. The main contribution is the integration of real-time dual-channel PPG acquisition, BLE transmission, embedded BPM estimation, desktop GUI visualization, and experimental validation within a single compact and low-cost platform. The proposed architecture is aimed at low-cost biomedical applications and offers a compact solution for signal acquisition, wireless communication, visualization, and basic physiological estimation. Experimental results show that the platform can reliably capture and transmit both channels, supporting its use as a foundation for future work on more advanced PPG processing and physiological monitoring applications. Furthermore, the system performance was validated by comparing the estimated heart rate against measurements obtained from two medical reference devices: a pulse oximeter and a digital sphygmomanometer. The results demonstrated good agreement between the measurements, supporting the feasibility of the proposed platform for non-invasive physiological monitoring applications.
- 10 October 2026
- Published by Cientifica, Revista Mexicana de Ingenieria Electromecanica y de Sistemas, IPN
- Vol. 30 (2) , 1-16
Low‑Cost Embedded System for Real‑Time Acquisition and Visualization of Photoplethysmographic Signals Using ESP32‑S3, BLE, and MAX30102
This paper presents a low-cost real-time photoplethysmography (PPG) monitoring platform based on an ESP32-S3 SuperMini, a MAX30102 sensor operating at 200 samples per second, and a desktop graphical user interface (GUI). The proposed system establishes Bluetooth Low Energy (BLE) communication between the embedded node and the PC interface to stream both infrared (IR) and red (RED) channels simultaneously. On the embedded side, the firmware acquires, packages, and transmits the raw PPG signals while estimating the heart rate in beats per minute (BPM) for each channel. On the desktop side, the GUI displays the received signals and the corresponding BPM values in real time, providing a practical and accessible monitoring environment. The main contribution is the integration of real-time dual-channel PPG acquisition, BLE transmission, embedded BPM estimation, desktop GUI visualization, and experimental validation within a single compact and low-cost platform. The proposed architecture is aimed at low-cost biomedical applications and offers a compact solution for signal acquisition, wireless communication, visualization, and basic physiological estimation. Experimental results show that the platform can reliably capture and transmit both channels, supporting its use as a foundation for future work on more advanced PPG processing and physiological monitoring applications. Furthermore, the system performance was validated by comparing the estimated heart rate against measurements obtained from two medical reference devices: a pulse oximeter and a digital sphygmomanometer. The results demonstrated good agreement between the measurements, supporting the feasibility of the proposed platform for non-invasive physiological monitoring applications.
- Open Access
Application of Information Theory to Computer Vision and Image Processing II
Information theory is the foundation for computer vision and image processing across diverse applications
Open AccessApplication of Information Theory to Computer Vision and Image Processing II
Information theory is the foundation for computer vision and image processing across diverse applications
- Open Access
Comparative Assessment of PPG-Derived HRV Using MAX30102 Sensor and Analog Circuitry with ADS1115 ADC
Heart rate variability (HRV) is a key physiological marker for autonomic nervous system function and cardiovascular health. Photoplethysmography (PPG) is commonly used to derive HRV metrics in wearable and low-cost monitoring systems. This study presents a comparative assessment of basic HRV metrics obtained from a MAX30102 optical sensor and a custom analog circuitry with an ADS1115 analog-to-digital converter (ADC). Both measurement pathways were carefully aligned using analog high-pass and low-pass filters and a consistent digital filtering pipeline, ensuring that the frequency bands relevant to HRV were preserved. PPG signals were recorded simultaneously, and inter-beat intervals were extracted to calculate the Standard Deviation of NN intervals (SDNN), Root Mean Square of Successive Differences (RMSSD), and Percentage of successive NN intervals >50 ms (pNN50) across multiple 30-s windows. Bland–Altman analysis was employed to evaluate agreement between the two methods. Results indicate that the analog circuit with an ADS1115 achieves comparable HRV basic metrics to the MAX30102 sensor, with improved Signal-to-Noise Ratio (SNR) due to high-resolution ADC and low-noise analog amplification. These findings demonstrate that a carefully designed analog acquisition system can reliably reproduce HRV basic parameters from PPG signals, providing an alternative approach for low-cost, flexible biosensing platforms.
Open AccessComparative Assessment of PPG-Derived HRV Using MAX30102 Sensor and Analog Circuitry with ADS1115 ADC
Heart rate variability (HRV) is a key physiological marker for autonomic nervous system function and cardiovascular health. Photoplethysmography (PPG) is commonly used to derive HRV metrics in wearable and low-cost monitoring systems. This study presents a comparative assessment of basic HRV metrics obtained from a MAX30102 optical sensor and a custom analog circuitry with an ADS1115 analog-to-digital converter (ADC). Both measurement pathways were carefully aligned using analog high-pass and low-pass filters and a consistent digital filtering pipeline, ensuring that the frequency bands relevant to HRV were preserved. PPG signals were recorded simultaneously, and inter-beat intervals were extracted to calculate the Standard Deviation of NN intervals (SDNN), Root Mean Square of Successive Differences (RMSSD), and Percentage of successive NN intervals >50 ms (pNN50) across multiple 30-s windows. Bland–Altman analysis was employed to evaluate agreement between the two methods. Results indicate that the analog circuit with an ADS1115 achieves comparable HRV basic metrics to the MAX30102 sensor, with improved Signal-to-Noise Ratio (SNR) due to high-resolution ADC and low-noise analog amplification. These findings demonstrate that a carefully designed analog acquisition system can reliably reproduce HRV basic parameters from PPG signals, providing an alternative approach for low-cost, flexible biosensing platforms.
- Open Access
- 22 December 2025
- Published by JVE International Ltd. in Mathematical Models in Engineering
- Vol. 11 (4) , 176-186
Effect of parametric modulation on the stability of a periodic oscillator: a study with Airy functions
This work investigates the stability of a linear oscillator with a periodically varying stiffness composed of constant and linearly time-dependent segments. By combining Floquet theory with an analytical formulation in terms of Airy functions, the monodromy matrix is obtained in closed form and the characteristic multipliers that determine the stability regime are calculated. Unlike the classical literature on Hill or Mathieu systems, where the stiffness profile is assumed to switch instantaneously or vary sinusoidally, the present model explicitly incorporates finite transition times through linear ramps. This allows us to quantify how the duration of these transitions affects the onset of parametric resonance. The resulting stability map reveals alternating bands of stable and unstable regions reminiscent of Arnold tongues, and shows that the proportion of the cycle spent in the linear-ramp stage plays a decisive role in either promoting or suppressing instability. Overall, the study provides a compact analytical and numerical framework for assessing stability in periodically driven parametric systems of practical relevance in physics and engineering.
- 22 December 2025
- Published by JVE International Ltd. in Mathematical Models in Engineering
- Vol. 11 (4) , 176-186
Open AccessEffect of parametric modulation on the stability of a periodic oscillator: a study with Airy functions
This work investigates the stability of a linear oscillator with a periodically varying stiffness composed of constant and linearly time-dependent segments. By combining Floquet theory with an analytical formulation in terms of Airy functions, the monodromy matrix is obtained in closed form and the characteristic multipliers that determine the stability regime are calculated. Unlike the classical literature on Hill or Mathieu systems, where the stiffness profile is assumed to switch instantaneously or vary sinusoidally, the present model explicitly incorporates finite transition times through linear ramps. This allows us to quantify how the duration of these transitions affects the onset of parametric resonance. The resulting stability map reveals alternating bands of stable and unstable regions reminiscent of Arnold tongues, and shows that the proportion of the cycle spent in the linear-ramp stage plays a decisive role in either promoting or suppressing instability. Overall, the study provides a compact analytical and numerical framework for assessing stability in periodically driven parametric systems of practical relevance in physics and engineering.
- Open Access
ESP32-Powered PPG Signal Acquisition: Open-Source Hardware and Software for Research and Education
To support the understanding of cardiovascular monitoring and physiological signal processing, we present a portable, open-source photoplethysmography (PPG) acquisition platform developed for educational and research applications. The system is built entirely with commercial off-the-shelf components and centers around an ESP32 microcontroller, which performs high-speed analog signal acquisition at 500 samples per second, alongside real-time control, and wireless communication. A cross-platform, Python-based graphical user interface enables real-time signal visualization, peak detection, and the computation of heart rate variability (HRV) metrics, including RMSSD and SDNN, during offline analysis. All hardware and software resources are openly available to enable replication and further development. This project emphasizes accessibility, transparency, and hands-on learning in biomedical signal acquisition. System functionality is validated offline through controlled data collection from human subjects, demonstrating results consistent with established HRV benchmarks.
Open AccessESP32-Powered PPG Signal Acquisition: Open-Source Hardware and Software for Research and Education
To support the understanding of cardiovascular monitoring and physiological signal processing, we present a portable, open-source photoplethysmography (PPG) acquisition platform developed for educational and research applications. The system is built entirely with commercial off-the-shelf components and centers around an ESP32 microcontroller, which performs high-speed analog signal acquisition at 500 samples per second, alongside real-time control, and wireless communication. A cross-platform, Python-based graphical user interface enables real-time signal visualization, peak detection, and the computation of heart rate variability (HRV) metrics, including RMSSD and SDNN, during offline analysis. All hardware and software resources are openly available to enable replication and further development. This project emphasizes accessibility, transparency, and hands-on learning in biomedical signal acquisition. System functionality is validated offline through controlled data collection from human subjects, demonstrating results consistent with established HRV benchmarks.
- 15 July 2025
- Published by Cientifica, Revista Mexicana de Ingenieria Electromecanica y de Sistemas, IPN
- Vol. 29 (2) , 1-15
Embedded biomedical development system for photoplethysmography signal processing based on a Programmable System-on-Chip (PSoC)
This work presents the design and implementation of an embedded platform that acquires and processes photoplethysmography (PPG) signals using only the internal resources of a programmable system-on-chip (PSoC). The acquisition unit incorporates LED emitters and a photodetector to capture variations in blood absorbance, followed by an analog conditioning stage designed with the PSoC’s internal operational amplifiers and a 12-bit SAR converter. The firmware implements a state machine that manages sampling at 500 Hz, while a graphical user interface (GUI) performs IIR digital filtering to reduce motion artifacts and low-frequency noise. To validate its performance, the embedded system was compared with a commercial oximeter. Under resting conditions, PPG signals were recorded simultaneously, and RR intervals and heart rate were calculated. The results showed a mean absolute error (MAE) of only 2.69 BPM compared to the reference oximeter. The use of integrated operational amplifiers and reconfigurable peripherals allowed for optimized power consumption and a reduced board size without compromising signal quality. The inherent flexibility of the PSoC architecture enables the implementation of a wide range of filtering and peak detection algorithms tailored to specific device requirements. This highlights the advantages of integrating analog and digital functionalities within a single chip, as opposed to conventional microcontroller-based solutions relying on discrete components. In the present study, the analog OpAmp module from the PSoC 4200M family (CY8C4247AZI M485) is employed for preprocessing and conditioning of the PPG signal. In conclusion, the PSoC-based prototype delivered satisfactory results in terms of accuracy, energy efficiency, and miniaturization, positioning itself as a promising alternative for telemedicine applications and continuous heart rate monitoring. Moreover, it offers a pathway for expanding toward advanced heart rate variability analysis and additional biomedical signal processing capabilities.
- 15 July 2025
- Published by Cientifica, Revista Mexicana de Ingenieria Electromecanica y de Sistemas, IPN
- Vol. 29 (2) , 1-15
Embedded biomedical development system for photoplethysmography signal processing based on a Programmable System-on-Chip (PSoC)
This work presents the design and implementation of an embedded platform that acquires and processes photoplethysmography (PPG) signals using only the internal resources of a programmable system-on-chip (PSoC). The acquisition unit incorporates LED emitters and a photodetector to capture variations in blood absorbance, followed by an analog conditioning stage designed with the PSoC’s internal operational amplifiers and a 12-bit SAR converter. The firmware implements a state machine that manages sampling at 500 Hz, while a graphical user interface (GUI) performs IIR digital filtering to reduce motion artifacts and low-frequency noise. To validate its performance, the embedded system was compared with a commercial oximeter. Under resting conditions, PPG signals were recorded simultaneously, and RR intervals and heart rate were calculated. The results showed a mean absolute error (MAE) of only 2.69 BPM compared to the reference oximeter. The use of integrated operational amplifiers and reconfigurable peripherals allowed for optimized power consumption and a reduced board size without compromising signal quality. The inherent flexibility of the PSoC architecture enables the implementation of a wide range of filtering and peak detection algorithms tailored to specific device requirements. This highlights the advantages of integrating analog and digital functionalities within a single chip, as opposed to conventional microcontroller-based solutions relying on discrete components. In the present study, the analog OpAmp module from the PSoC 4200M family (CY8C4247AZI M485) is employed for preprocessing and conditioning of the PPG signal. In conclusion, the PSoC-based prototype delivered satisfactory results in terms of accuracy, energy efficiency, and miniaturization, positioning itself as a promising alternative for telemedicine applications and continuous heart rate monitoring. Moreover, it offers a pathway for expanding toward advanced heart rate variability analysis and additional biomedical signal processing capabilities.
- Open Access
Efficient Learning-Based Robotic Navigation Using Feature-Based RGB-D Pose Estimation and Topological Maps
Robust indoor robot navigation typically demands either costly sensors or extensive training data. We propose a cost-effective RGB-D navigation pipeline that couples feature-based relative pose estimation with a lightweight multi-layer-perceptron (MLP) policy. RGB-D keyframes extracted from human-driven traversals form nodes of a topological map; edges are added when visual similarity and geometric–kinematic constraints are jointly satisfied. During autonomy, LightGlue features and SVD give six-DoF relative pose to the active keyframe, and the MLP predicts one of four discrete actions. Low visual similarity or detected obstacles trigger graph editing and Dijkstra replanning in real time. Across eight tasks in four Habitat-Sim environments, the agent covered 190.44 m, replanning when required, and consistently stopped within 0.1 m of the goal while running on commodity hardware. An information-theoretic analysis over the Multi-Illumination dataset shows that LightGlue maximizes per-second information gain under lighting changes, motivating its selection. The modular design attains reliable navigation without metric SLAM or large-scale learning, and seamlessly accommodates future perception or policy upgrades.
Open AccessEfficient Learning-Based Robotic Navigation Using Feature-Based RGB-D Pose Estimation and Topological Maps
Robust indoor robot navigation typically demands either costly sensors or extensive training data. We propose a cost-effective RGB-D navigation pipeline that couples feature-based relative pose estimation with a lightweight multi-layer-perceptron (MLP) policy. RGB-D keyframes extracted from human-driven traversals form nodes of a topological map; edges are added when visual similarity and geometric–kinematic constraints are jointly satisfied. During autonomy, LightGlue features and SVD give six-DoF relative pose to the active keyframe, and the MLP predicts one of four discrete actions. Low visual similarity or detected obstacles trigger graph editing and Dijkstra replanning in real time. Across eight tasks in four Habitat-Sim environments, the agent covered 190.44 m, replanning when required, and consistently stopped within 0.1 m of the goal while running on commodity hardware. An information-theoretic analysis over the Multi-Illumination dataset shows that LightGlue maximizes per-second information gain under lighting changes, motivating its selection. The modular design attains reliable navigation without metric SLAM or large-scale learning, and seamlessly accommodates future perception or policy upgrades.
- Open Access
3D Data Processing and Entropy Reduction for Reconstruction from Low-Resolution Spatial Coordinate Clouds in a Technical Vision System
This paper proposes an advancement in the application of a Technical Vision System (TVS), which integrates a laser scanning mechanism with a single light sensor to measure 3D spatial coordinates. In this application, the system is used to scan and digitalize objects using a rotating table to explore the potential of the system for 3D scanning at reduced resolutions. The experiments undertaken searched for optimal scanning windows and used statistical data filtering techniques and regression models to find a method to generate a 3D scan that was still recognizable with the least amount of 3D points, balancing the number of points scanned and time, while at the same time reducing effects caused by the particularities of the TVS, such as noise and entropy in the form of natural distortion in the resulting scans. The evaluation of the experimentation results uses 3D point registration methods, joining multiple faces from the original volume scanned by the TVS and aligning it to the ground truth model point clouds, which are based on a commercial 3D camera to verify that the reconstructed 3D model retains substantial detail from the original object. This research finds it is possible to reconstruct sufficiently detailed 3D models obtained from the TVS, which contain coarsely scanned data or scans that initially lack high definition or are too noisy.
Open Access3D Data Processing and Entropy Reduction for Reconstruction from Low-Resolution Spatial Coordinate Clouds in a Technical Vision System
This paper proposes an advancement in the application of a Technical Vision System (TVS), which integrates a laser scanning mechanism with a single light sensor to measure 3D spatial coordinates. In this application, the system is used to scan and digitalize objects using a rotating table to explore the potential of the system for 3D scanning at reduced resolutions. The experiments undertaken searched for optimal scanning windows and used statistical data filtering techniques and regression models to find a method to generate a 3D scan that was still recognizable with the least amount of 3D points, balancing the number of points scanned and time, while at the same time reducing effects caused by the particularities of the TVS, such as noise and entropy in the form of natural distortion in the resulting scans. The evaluation of the experimentation results uses 3D point registration methods, joining multiple faces from the original volume scanned by the TVS and aligning it to the ground truth model point clouds, which are based on a commercial 3D camera to verify that the reconstructed 3D model retains substantial detail from the original object. This research finds it is possible to reconstruct sufficiently detailed 3D models obtained from the TVS, which contain coarsely scanned data or scans that initially lack high definition or are too noisy.
- Open Access
- 22 June 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (13) , 1940
Mathematical Modeling for Robot 3D Laser Scanning in Complete Darkness Environments to Advance Pipeline Inspection
This paper introduces an autonomous robot designed for in-pipe structural health monitoring of oil/gas pipelines. This system employs a 3D Optical Laser Scanning Technical Vision System (TVS) to continuously scan the internal surface of the pipeline. This paper elaborates on the mathematical methodology of 3D laser surface scanning based on dynamic triangulation. This paper presents the mathematical framework governing the combined kinematics of the Mobile Robot (MR) and TVS. It discusses the custom design of the MR, adjusting it to use of robustized mathematics, and incorporating a laser scanner produced using a 3D printer. Both experimental and theoretical approaches are utilized to illustrate the formation of point clouds during surface scanning. This paper details the application of the simple and robust mathematical algorithm RANSAC for the preliminary processing of the measured point clouds. Furthermore, it contributes two distinct and simplified criteria for detecting defects in pipelines, specifically tailored for computer processing. In conclusion, this paper assesses the effectiveness of the proposed mathematical and physical method through experimental tests conducted under varying light conditions.
- 22 June 2024
- Published by MDPI AG in Mathematics
- Vol. 12 (13) , 1940
Open AccessMathematical Modeling for Robot 3D Laser Scanning in Complete Darkness Environments to Advance Pipeline Inspection
This paper introduces an autonomous robot designed for in-pipe structural health monitoring of oil/gas pipelines. This system employs a 3D Optical Laser Scanning Technical Vision System (TVS) to continuously scan the internal surface of the pipeline. This paper elaborates on the mathematical methodology of 3D laser surface scanning based on dynamic triangulation. This paper presents the mathematical framework governing the combined kinematics of the Mobile Robot (MR) and TVS. It discusses the custom design of the MR, adjusting it to use of robustized mathematics, and incorporating a laser scanner produced using a 3D printer. Both experimental and theoretical approaches are utilized to illustrate the formation of point clouds during surface scanning. This paper details the application of the simple and robust mathematical algorithm RANSAC for the preliminary processing of the measured point clouds. Furthermore, it contributes two distinct and simplified criteria for detecting defects in pipelines, specifically tailored for computer processing. In conclusion, this paper assesses the effectiveness of the proposed mathematical and physical method through experimental tests conducted under varying light conditions.
- 31 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (14) , 22189-22196
Data-Drive-Based Machine Learning and Singular Spectrum Analysis to Identify Optical Patterns in Harsh Environments
This paper proposes an enhancement of a singular spectrum analysis (SSA) technique based on Hilbert Matrix (SSA-H) for autonomous navigation systems in a harsh environment. SSA is a technique that has caught the attention of different fields, and is used to extract trends and patterns in the time series domain. In this work, SSA-H is used to transform raw optical signals into meaningful information to build machine learning (ML) models. A technical vision system (TVS) with laser scanning for depth measurements is presented. According to the implementation of the TVS outdoors, some particular issues, such as interference radiation detected by its photodiode, can affect the system’s performance in determining depth measurements. This research extracts the laser beam patterns in a real environment to create ML models to solve the problem and address some of the technical challenges in a real environment. The main contribution of this work is designing an ML framework for recognizing the laser beam of the TVS based on SSA-H. Furthermore, a comparative analysis of ML techniques to discriminate sunlight interference was studied and compared with different configurations of SSA known in the literature. According to the results, the use of SSA-H can enhance the ML models such as Ensemble Learning (EL), Feed-Forward Neural Networks (FNN), Support Vector Machines (SVM), Naive Bayes (NB) in conjunction with autocorrelation function coefficients (ACC) as features.
- 31 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (14) , 22189-22196
Data-Drive-Based Machine Learning and Singular Spectrum Analysis to Identify Optical Patterns in Harsh Environments
This paper proposes an enhancement of a singular spectrum analysis (SSA) technique based on Hilbert Matrix (SSA-H) for autonomous navigation systems in a harsh environment. SSA is a technique that has caught the attention of different fields, and is used to extract trends and patterns in the time series domain. In this work, SSA-H is used to transform raw optical signals into meaningful information to build machine learning (ML) models. A technical vision system (TVS) with laser scanning for depth measurements is presented. According to the implementation of the TVS outdoors, some particular issues, such as interference radiation detected by its photodiode, can affect the system’s performance in determining depth measurements. This research extracts the laser beam patterns in a real environment to create ML models to solve the problem and address some of the technical challenges in a real environment. The main contribution of this work is designing an ML framework for recognizing the laser beam of the TVS based on SSA-H. Furthermore, a comparative analysis of ML techniques to discriminate sunlight interference was studied and compared with different configurations of SSA known in the literature. According to the results, the use of SSA-H can enhance the ML models such as Ensemble Learning (EL), Feed-Forward Neural Networks (FNN), Support Vector Machines (SVM), Naive Bayes (NB) in conjunction with autocorrelation function coefficients (ACC) as features.