Gang Hua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gang Hua has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Xianchao Yu
School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, China
3 shared publicationsHui Tang
Xuzhou Medical University, No. 209 Tongshan Road, Xuzhou, Jiangsu, China, Xuzhou, Jiangsu, 221004, China
2 shared publicationsHuihui Wang
The First Affiliated Hospital of Anhui Medical University, Anhui, China., Hefei, Anhui, 230022, China
2 shared publicationsLu Tang
Xuzhou Medical University, Xuzhou, China
2 shared publications- Yinghong Zhao
Xuzhou Medical University, Xuzhou, China
2 shared publications Aoxue Chen
Xuzhou Medical University, No. 209 Tongshan Road, Xuzhou, Jiangsu, China, Xuzhou, 221004, China
1 shared publication
Latest Publications
- 24 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035007
Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study
Cardiovascular disease remains the leading cause of global mortality, with the rupture of vulnerable atherosclerotic plaques accounting for the majority of acute myocardial infarctions. While plaque morphology and composition are well recognized as critical determinants of vulnerability, their combined effects across clinically relevant stenosis severities (50%–80%) remain incompletely understood. To address this gap, this study aimed to systematically investigate the collective influence of plaque geometry (eccentric vs. concentric) and material composition (lipid, fibrous, calcified) on coronary hemodynamics and mechanical plaque stability under identical stenosis conditions. The left anterior descending artery were reconstructed using clinical computed tomography angiography data, and key hemodynamic (wall shear stress [WSS], oscillatory shear index [OSI], relative residence time [RRT]) and structural metrics (plaque von Mises stress and deformation) were quantified via coupled computational fluid dynamics and fluid-structure interaction simulations. The results demonstrated that eccentric plaques induced significantly more pronounced asymmetric flow disturbances, steeper WSS gradients, and higher RRT values compared to concentric geometries, particularly at higher stenosis severities; notably, at 70% stenosis, the mean RRT of eccentric plaques (0.108 65) was nearly double that of concentric plaques (0.056 86), and eccentric plaques exhibited a unique low-oscillatory shear environment with upstream mean OSI reduced to 0.141 01, whereas concentric plaques showed upstream mean OSI elevated to 0.256 07. Compositionally, lipid-rich regions experienced the greatest deformation, highlighting their role as mechanical ‘weak spots,’ whereas calcified areas showed minimal deformation but generated interfacial stress concentrations. These findings elucidate the synergistic interaction between plaque geometry and composition in modulating coronary hemodynamics and mechanical integrity, with eccentric morphology exacerbating adverse biomechanical conditions as stenosis progresses. This study provides a novel, multiscale biomechanical framework for assessing plaque vulnerability and informs the development of personalized intervention strategies tailored to specific plaque characteristics.
- 24 April 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035007
Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study
Cardiovascular disease remains the leading cause of global mortality, with the rupture of vulnerable atherosclerotic plaques accounting for the majority of acute myocardial infarctions. While plaque morphology and composition are well recognized as critical determinants of vulnerability, their combined effects across clinically relevant stenosis severities (50%–80%) remain incompletely understood. To address this gap, this study aimed to systematically investigate the collective influence of plaque geometry (eccentric vs. concentric) and material composition (lipid, fibrous, calcified) on coronary hemodynamics and mechanical plaque stability under identical stenosis conditions. The left anterior descending artery were reconstructed using clinical computed tomography angiography data, and key hemodynamic (wall shear stress [WSS], oscillatory shear index [OSI], relative residence time [RRT]) and structural metrics (plaque von Mises stress and deformation) were quantified via coupled computational fluid dynamics and fluid-structure interaction simulations. The results demonstrated that eccentric plaques induced significantly more pronounced asymmetric flow disturbances, steeper WSS gradients, and higher RRT values compared to concentric geometries, particularly at higher stenosis severities; notably, at 70% stenosis, the mean RRT of eccentric plaques (0.108 65) was nearly double that of concentric plaques (0.056 86), and eccentric plaques exhibited a unique low-oscillatory shear environment with upstream mean OSI reduced to 0.141 01, whereas concentric plaques showed upstream mean OSI elevated to 0.256 07. Compositionally, lipid-rich regions experienced the greatest deformation, highlighting their role as mechanical ‘weak spots,’ whereas calcified areas showed minimal deformation but generated interfacial stress concentrations. These findings elucidate the synergistic interaction between plaque geometry and composition in modulating coronary hemodynamics and mechanical integrity, with eccentric morphology exacerbating adverse biomechanical conditions as stenosis progresses. This study provides a novel, multiscale biomechanical framework for assessing plaque vulnerability and informs the development of personalized intervention strategies tailored to specific plaque characteristics.
- 9 April 2024
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 37 (4) , 1063-1075
Hemodynamics in nutcracker syndrome: implications for diagnosis
Background Nutcracker syndrome is a disease characterized by complex symptoms, making its diagnosis challenging and often delayed, often resulting in a painful experience for the patients. Objective This study aimed to investigate the pathogenesis of nutcracker syndrome through the perspective of hemodynamics by simulating blood flow with varying compression degrees of the left renal vein. Methods 3D patient-specific vascular models of the abdominal aorta, superior mesenteric artery and left renal vein were constructed based on CT images of patients suspected of having nutcracker syndrome. A hemodynamic simulation was then conducted using computational fluid dynamics to identify the correlation between alterations in hemodynamic parameters and varying degrees of compression. Results The study indicated the presence of an evident gradient in velocity distribution over the left renal vein with relatively high degrees of stenosis (α ≤ 50°), with maximum velocity in the central region of the stenosis. Additionally, when the compression degree of the left renal vein increases, the pressure distribution of the left renal vein presents an increasing number of gradient layers. Furthermore, the wall shear stress shows a correlation with the variation of blood flow velocity, i.e., the increase of wall shear stress correlates with the acceleration of the blood flow velocity. Conclusions Using computational fluid dynamics as a non-invasive instrument to obtain the hemodynamic characteristics of nutcracker syndrome is feasible and could provide insights into the pathological mechanisms of the nutcracker syndrome supporting clinicians in diagnosis. Graphical abstract
- 9 April 2024
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 37 (4) , 1063-1075
Hemodynamics in nutcracker syndrome: implications for diagnosis
Background Nutcracker syndrome is a disease characterized by complex symptoms, making its diagnosis challenging and often delayed, often resulting in a painful experience for the patients. Objective This study aimed to investigate the pathogenesis of nutcracker syndrome through the perspective of hemodynamics by simulating blood flow with varying compression degrees of the left renal vein. Methods 3D patient-specific vascular models of the abdominal aorta, superior mesenteric artery and left renal vein were constructed based on CT images of patients suspected of having nutcracker syndrome. A hemodynamic simulation was then conducted using computational fluid dynamics to identify the correlation between alterations in hemodynamic parameters and varying degrees of compression. Results The study indicated the presence of an evident gradient in velocity distribution over the left renal vein with relatively high degrees of stenosis (α ≤ 50°), with maximum velocity in the central region of the stenosis. Additionally, when the compression degree of the left renal vein increases, the pressure distribution of the left renal vein presents an increasing number of gradient layers. Furthermore, the wall shear stress shows a correlation with the variation of blood flow velocity, i.e., the increase of wall shear stress correlates with the acceleration of the blood flow velocity. Conclusions Using computational fluid dynamics as a non-invasive instrument to obtain the hemodynamic characteristics of nutcracker syndrome is feasible and could provide insights into the pathological mechanisms of the nutcracker syndrome supporting clinicians in diagnosis. Graphical abstract
- Open Access
- 27 March 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-13
Time-resolved simulation of blood flow through left anterior descending coronary artery: effect of varying extent of stenosis on hemodynamics
Background and objectives: Real-time blood flow variation is crucial for understanding the dynamic development of coronary atherosclerosis. The main objective of this study is to investigate the effect of varying extent of stenosis on the hemodynamic features in left anterior descending coronary artery. Methods: Various Computational fluid dynamics (CFD) models were constructed with patient-specific CT image data, using actual fractional flow reserve (FFR) as boundary conditions to provide a real-time quantitative description of hemodynamic properties. The hemodynamic parameters, such as the local and instantaneous wall shear stress (WSS), oscillating shear index (OSI) and relative residence time (RRT), blood flow velocity and pressure drop during various phases of cardiac cycle were provided in detail. Results: There was no evident variation in hemodynamic parameters in the cases of less than 50% stenosis while there were abrupt and dramatic changes in hemodynamics when the stenosis aggravated from 60 to 70%. Furthermore, when the stenosis was beyond 70%, there existed substantial pressure difference, WSS, and blood flow velocity in the center of the stenosis. Although OSI and RRT increased along with the aggravation of stenosis, they appeared with obvious abnormalities across all cases, even in mild stenosis. Conclusion: The simulation could present a dynamic and comprehensive profile of how hemodynamic parameters vary in accordance with divergent severities of stenosis, which could serve as an effective reference for the clinicians to have a deeper insight into the pathological mechanism of coronary atherosclerosis and stenosis.
- 27 March 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-13
Open AccessTime-resolved simulation of blood flow through left anterior descending coronary artery: effect of varying extent of stenosis on hemodynamics
Background and objectives: Real-time blood flow variation is crucial for understanding the dynamic development of coronary atherosclerosis. The main objective of this study is to investigate the effect of varying extent of stenosis on the hemodynamic features in left anterior descending coronary artery. Methods: Various Computational fluid dynamics (CFD) models were constructed with patient-specific CT image data, using actual fractional flow reserve (FFR) as boundary conditions to provide a real-time quantitative description of hemodynamic properties. The hemodynamic parameters, such as the local and instantaneous wall shear stress (WSS), oscillating shear index (OSI) and relative residence time (RRT), blood flow velocity and pressure drop during various phases of cardiac cycle were provided in detail. Results: There was no evident variation in hemodynamic parameters in the cases of less than 50% stenosis while there were abrupt and dramatic changes in hemodynamics when the stenosis aggravated from 60 to 70%. Furthermore, when the stenosis was beyond 70%, there existed substantial pressure difference, WSS, and blood flow velocity in the center of the stenosis. Although OSI and RRT increased along with the aggravation of stenosis, they appeared with obvious abnormalities across all cases, even in mild stenosis. Conclusion: The simulation could present a dynamic and comprehensive profile of how hemodynamic parameters vary in accordance with divergent severities of stenosis, which could serve as an effective reference for the clinicians to have a deeper insight into the pathological mechanism of coronary atherosclerosis and stenosis.