JJJohn Jose

John Jose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Jose has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Self‐Expandable Acurate Neo‐2 and Balloon‐Expandable Myval Transcatheter Heart Valves at 4‐Year Follow‐Up

    by Akash Jain, John Jose, Matteo Montorfano, Henrik Nissen, Pedro Martin, Ashok Seth, Kresimir Stambuk, Sengottuvelu Gunasekaran, Abdurashid Mussayev, Mario García‐Gómez, et al.

    Background: Recently, Acurate neo2 (ACN2; Boston Scientific, US) and Sapien‐3 series (Edwards Lifesciences, US) were compared in the IDE trial failing to demonstrate non‐inferiority of ACN2. The Myval series (MyV), an alternative balloon‐expandable device, demonstrated non‐inferiority compared to Sapien‐3 and Evolut (Medtronic, US) in the LANDMARK trial. However, no direct comparison exists between ACN2 and MyV. Aims: We aimed to compare mid‐term clinical and hemodynamic outcomes of the ACN2 and MyV transcatheter heart valves. Methods: This multicenter retrospective analysis included patients implanted with ACN2 and MyV series devices. The primary objective was to assess 1‐year mortality and stroke rates. Secondary outcomes included technical success, mortality, stroke, residual aortic regurgitation (AR), mean aortic gradients, and new permanent pacemaker implantation (PPI) rates up to 4 years. A matched comparison adjusting for clinical and anatomical characteristics was performed and echocardiograms were centrally analyzed. Results: A total of 545 patients (ACN2: 144; MyV: 401) from nine institutions were included. Matched technical success rates were 87.6% and 94.4%, p = 0.180 (90.3% for ACN2 and 97% for MyV; p < 0.001 in unmatched). In‐hospital matched PPI rates were 10.1% for ACN2 and 9% for MyV. At 4 years, matched residual ≥ moderate AR rates were similar (ACN2: 15.8% vs. MyV: 21.1%, p = 0.706), though ACN2 showed better mean aortic gradients (9.2 ± 4.2 vs. 13.1 ± 5.4, p = 0.001) and effective orifice area. Unmatched mortality + stroke rates were comparable but lower for ACN2 after matching (3.4% vs. 15.7%, p = 0.005). Importantly, cardiovascular mortality (3.4% for ACN2 and 5.6% for MyV, p = 0.720) and valve‐related deaths were comparable. Conclusion: ACN2 showed superior long‐term hemodynamics and lower matched 4‐year mortality and stroke rates, though cardiovascular mortality and valve‐related deaths were comparable.

  • Novel 35-mm Balloon-Expandable Transcatheter Aortic Valve Replacement

    by John Jose, Paul V. George, Shohiab Ur Riyaz Mirza, Pratheesh George Mathen, Sakthivel Selvaraj, Haynes Raja


  • Open Access

    One-Year Outcomes after Myval Implantation in Patients with Bicuspid Aortic Valve Stenosis—A Multicentre Real-World Experience

    by Ahmed Elkoumy, John Jose, Christian Juhl Terkelsen, Henrik Nissen, Sengottuvelu Gunasekaran, Mahmoud Abdelshafy, Ashok Seth, Hesham Elzomor, Sreenivas Kumar, Francesco Bedogni, et al.

    Background: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. Aim: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. Methods and results: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. Conclusions: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.


  • Open Access

    Transcatheter Mitral Valve-in-Valve Implantation with the Balloon-Expandable Myval Device

    by Sara Blasco-Turrión, Ana Serrador-Frutos, John Jose, Gunasekaran Sengotuvelu, Ashok Seth, Victor G. Aldana, Juan Pablo Sánchez-Luna, Jose Carlos Gonzalez-Gutiérrez, Mario García-Gómez, Javier Gómez-Herrero, et al.

    Background: The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Methods: Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. Results: A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Conclusions: Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.


  • Open Access

    Safety and Efficacy of Myval Implantation in Patients with Severe Bicuspid Aortic Valve Stenosis—A Multicenter Real-World Experience

    by Ahmed Elkoumy, John Jose, Christian J. Terkelsen, Henrik Nissen, Sengottuvelu Gunasekaran, Mahmoud Abdelshafy, Ashok Seth, Hesham Elzomor, Sreenivas Kumar, Francesco Bedogni, et al.

    Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI’s procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.


  • Clinical evaluation of the Hydra self‐expanding transcatheter aortic valve: 6 month results from the GENESIS trial

    by Praveen Chandra, John Jose, Shafeeq Mattummal, Ajaykumar U. Mahajan, Sajeev C. Govindan, Chandrashekhar N. Makhale, Sharad Chandra, Ranjan Shetty, Sandeep Mohanan, John F. John, et al.

    Objectives: To evaluate the safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk.Background: The Hydra THV (Vascular Innovations Co. Ltd., Nonthaburi, Thailand) is a novel flexible repositionable self‐expanding system with supra‐annular bovine pericardial leaflets, available in three sizes, covering aortic annuli between 17 and 27 mm.Methods: The GENESIS trial was a prospective, multi‐center, single‐arm, 6 month follow‐up study conducted in India. The primary performance endpoint was device success defined as per VARC‐II criteria at 30 days. The primary safety endpoint was all‐cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee.Results: Forty high‐risk patients (74.5 ± 6.7 years, 60% men; STS Score:5.6 ± 4.2%) were enrolled in 11 centres. Device success was achieved in 92.5%. The effective orifice area improved from 0.7 ± 0.2 to 2.3 ± 0.6 cm2 at 30 days and to 2.2 ± 0.7 cm2 at 6 months (p < .0001). Mean aortic valve gradient decreased from 53.5 ± 18.1 to 8.9 ± 4.9 mmHg at 30 days and to 7.6 ± 2.7 mmHg at 6 months (p < .0001). The rate of new permanent pacemaker implantation was 7.5% at 30 days, and no patient had more than mild paravalvular leak at 6 months. The 30 days and 6 month all‐cause mortality was 10.0 and 17.5%, cardiovascular mortality 7.5 and 7.5%, device‐related mortality 5.0 and 5.0%, respectively. No patients had stroke up to 6 months.Conclusions: The GENESIS trial demonstrated high efficacy of the self‐expanding Hydra THV. The cardiovascular mortality rate of 7.5% may partly be explained by the inclusion of some centres with no or limited previous experience in transcatheter aortic valve implantation.


  • Open Access

    Transcatheter aortic valve implantation with a novel pre-packaged self-expandable dry-tissue transcatheter aortic valve: a case report

    by John Jose, Paul V George, Krishnaprasath V., Raj Sahajanandan

    Background: Current commercially available transcatheter aortic valves are stored separately in a glutaraldehyde solution and mounted onto the delivery system by a technical expert during the transcatheter aortic valve implantation (TAVI) procedure. A pre-mounted dry-tissue valve that is crimped on a ready-to-use delivery system could simplify the procedure. The Vienna self-expanding transcatheter valve (P&F, GmbH, Wessling, Germany) is a novel ready-to-use pre-mounted dry-tissue transcatheter aortic valve. There are no prior reports on the efficacy of this valve system. Case summary: Here, we report our experience of an implantation of a novel ready-to-use dry-tissue Vienna transcatheter aortic valve in a 72-year-old male with symptomatic severe aortic stenosis and severe left ventricular systolic dysfunction. He had presented with heart failure [N-terminal pro-brain natriuretic peptide (NT-proBNP) level at the admission of 10 600 pg/mL], New York Heart Association Class-3, and recurrent syncope. A 26 mm Vienna valve was successfully implanted via the transfemoral route under conscious sedation. There were no complications. The patient was discharged in a stable condition on the third post-procedure day. At 1-year follow-up, the valve is functioning well with no evidence of structural degeneration (mean gradient 9 mmHg, no valvular regurgitation). Currently, he is asymptomatic with normal left ventricular systolic function on echocardiography (NT-proBNP 57 pg/mL). Discussion: To our knowledge, this is the first case of TAVI performed with the dry-tissue pre-mounted VIENNA valve. Our case highlights the feasibility and short-term efficacy of the VIENNA valve. Further safety and durability need to be addressed by a multicentre trial.


  • Neointimal coverage of overlapping everolimus-eluting bioresorbable scaffolds: An optical coherence tomography study in native coronary arteries

    by Takao Sato, John Jose, Mohamed El-Mawardy, Dmitriy S. Sulimov, Ralph Tölg, Gert Richardt, Mohamed Abdel-Wahab


  • Open Access

    Setting up a transcatheter aortic valve implantation program: Indian perspective

    by John Jose, Geetesh Manik, Mohamed Abdel-Wahab