JCJavier Chavez

Javier Chavez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Javier Chavez has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of epileptogenesis on hypercapnic cardioventilatory response in kainic acid rats

    by Auriane Apaire, Elise Collard, Abigail Niyibizi, Natasha N. Kumar, Enrique Germany Morrison, Javier Chavez Cerda, Ayse S. Dereli, Riem El Tahry

    Objective: Cardioventilatory failure is the leading mechanism proposed to underlie sudden unexpected death in epilepsy (SUDEP), which occurs predominantly at night in patients with generalized tonic–clonic seizures. Interictal hypercapnic cardioventilatory responses are suggested to be involved, as they are ablated in chronically epileptic kainic acid (KA) rats, a temporal lobe epilepsy model with focal to bilateral tonic–clonic seizures. However, how this impairment emerges during epileptogenesis and whether it is influenced by day/night period remain unclear. Here, we aimed to investigate the progress of hypercapnic cardioventilatory responses through the epileptogenesis of KA rats and whether it is affected by day or night. Methods: Ventilatory or breathing frequency (f B ) and heart rate (HR) were measured before, during, and after a 1‐h exposure to acute hypercapnia (10% CO 2 ) using photoplethysmography in KA and healthy rats. Measurements were performed monthly for 6 months, with additional nocturnal hypercapnia recordings at month 6 to assess day/night modulation. To control for repeated CO 2 exposure, an independent cohort of age‐matched KA and healthy rats underwent a single hypercapnia exposure at month 6. Results: In healthy rats, cardioventilatory responses to hypercapnia remained stable over time, with increased f B and reduced HR. Conversely, KA rats displayed an abrupt blunting of the f B response at month 4, followed by blunting of the HR response at month 6. Correlation analyses revealed a loss of correlation between f B and HR following KA injection, which reemerged when the cardioventilatory response to CO 2 was fully ablated. No association was observed between seizure severity and cardioventilatory impairment. KA rats displayed similar deficits regardless of CO 2 exposure frequency, and no day–night differences were detected in either group. Significance: These findings indicate that cardioventilatory responses are decreased during epileptogenesis in the KA model, suggesting their potential utility for evaluating SUDEP risk.

  • Characterization of vagus nerve active fibers during seizure in rats

    by Javier Chávez Cerda, Elena Acedo Reina, Cedric Luppens, Louis Vande Perre, Romain Raffoul, Maxime Verstraeten, Enrique Germany Morrison, Hugo Smets, Pascal Doguet, Jérôme Garnier, et al.

    Objective . Epilepsy affects approximately 70 million individuals worldwide. Vagus nerve activity is known to be modulated by seizures; however, the types of fibers that are activated during seizures remain unknown. This work compares the electrical activity of the vagus nerve before, during, and after seizures in epileptic rats. Approach . Six rats experiencing pentylenetetrazol-induced epilepsy seizures and two rats under saline solution were investigated. Action potentials (AP) identified by template matching were sorted according to the fiber type they are deemed to originate from. AP templates were based on a 3D COMSOL simplified model of the vagus nerve. Model templates were established for fibers of different diameters based on histology. Correspondences are thus established based on specific fiber diameters. Main results . During seizures, an increase in the percentage of occurrence of APs was observed for 2 μ m and 3 μ m fibers, while a decrease was observed for 4 µ m, 5–6 µ m, and 7–11 µ m fibers. This was not observed in the rat group under saline solution. The increase in smaller diameter sizes is believed to be linked to an increase in autonomic activity. Significance . These findings contribute to a better understanding of vagus nerve dynamics during epileptic seizures and highlight the potential of vagus nerve activity as a physiological marker for seizure detection and monitoring. This would be of particular interest in vagus nerve stimulation to control any closed-loop form of therapy. This work provides a foundation for developing novel diagnostic and therapeutic approaches in epilepsy management.

  • Urinary bladder phantom mimicking mechanical properties and pressure during filling

    by Maxime Verstraeten, George Bou Kheir, Louis Vande Perre, Romain Raffoul, Javier Chavez Cerda, Alain Delchambre, Thierry Roumeguere, Anne Vanhoestenberghe, Antoine Nonclercq

    Objective. Phantoms that mimic healthy or diseased organ properties can complement animal models for surgical planning, training, and medical device development. If urodynamic studies rely on pressure-volume curves to assess lower urinary tract symptoms, there is an unsatisfied need for a bladder phantom that accurately mimics the bladder stretching capabilities and compliant behaviour during physiological filling. Approach. We demonstrate the suitability of water-soluble 3D-printed moulds as a versatile method to fabricate accurate phantoms with anatomical structures reconstructed from medical images. We report a phantom fabricated with silicone rubber. A wire net limits the silicone expansion to model the cystometric capacity. A mathematical model describes the pressure increase due to passive hyperelastic properties. Main results. The phantom reproduces the bladder’s mechanical properties during filling. The pressure-volume curve measured on the phantom is typical of cystometric studies, with a compliance of 25.2 ± 1 ml cmH 2 O − 1 . The root-mean-square error between the theoretical model and experimental data is 2.7 cmH 2 O . The compliance, bladder wall thickness, cystometric capacity and pressure near the cystometric capacity of the phantom can be tuned to mimic various pathologies or human variability. Significance. The manufacturing method is suitable for fabricating bladder and other soft and hollow organ phantoms. The mathematical model provides a method to determine design parameters to model healthy or diseased bladders. Soft hollow organ phantoms can be used to complement animal experimentations for developing and validating medical devices aiming to be anchored on these organs or monitor their activity through pressure and strain measurement.


  • Chronic recording of the vagus nerve to analyze modulations by the light–dark cycle

    by Hugo Smets, Lars Stumpp, Javier Chavez, Joaquin Cury, Louis Vande Perre, Pascal Doguet, Anne Vanhoestenberghe, Jean Delbeke, Riëm El Tahry, Antoine Nonclercq

    Objective. The vagus nerve is considered to play a key role in the circadian rhythm. Chronic continuous analysis of the vagus nerve activity could contribute to a better understanding of the role of the vagus nerve in light–dark modulations. This paper presents a continuous analysis of spontaneous vagus nerve activity performed in four rats. Approach. We analyzed the vagus electroneurogram (VENG) and electroencephalogram (EEG) over a recording period of 28 d. Spike activity and heart rate estimation were derived from the VENG, and slow-wave activity was derived from the EEG. The presence of repetitive patterns was investigated with periodograms, cosinor fitting, autocorrelation, and statistical tests. The light–dark variations derived from the VENG spikes were compared with EEG slow waves, an established metric in circadian studies. Results. Our results demonstrate that light–dark variations can be detected in long-term vagus nerve activity monitoring. A recording period of about 7 d is required to characterize accurately the VENG light–dark variations. Significance. As a major outcome of this study, vagus nerve recordings hold the promise to help understand circadian regulation.


  • Open Access

    Online marketing practices of regenerative medicine clinics in US-Mexico border region: a web surveillance study

    by Javier Chavez, Neal A. Shah, Severin Ruoss, Raphael E. Cuomo, Samuel R. Ward, Tim K. Mackey

    Introduction: The potential of regenerative medicine to improve human health has led to the rapid expansion of stem cell clinics throughout the world with varying levels of regulation and oversight. This has led to a market ripe for stem cell tourism, with Tijuana, Mexico, as a major destination. In this study, we characterize the online marketing, intervention details, pricing of services, and assess potential safety risks through web surveillance of regenerative medicine clinics marketing services in Tijuana. Methods: We conducted structured online search queries from March to April 2019 using 296 search terms in English and Spanish on two search engines (Google and Bing) to identify websites engaged in direct-to-consumer advertising of regenerative medicine services. We performed content analysis to characterize three categories of interest: online presence, tokens of scientific legitimacy, and intervention details. Results: Our structured online searches resulted in 110 unique websites located in Tijuana corresponding to 76 confirmed locations. These clinics’ online presence consisted of direct-to-consumer advertising mainly through a dedicated website (94.5%) or Facebook page (65.5%). The vast majority of these websites (99.1%) did not mention any affiliation to an academic institutions or other overt tokens of scientific legitimacy. Most clinics claimed autologous tissue was the source of treatments (67.3%) and generally did not specify route of administration. Additionally, of the Tijuana clinics identified, 13 claimed licensing, though only 1 matched with available licensing information. Conclusions: Regenerative medicine clinics in Tijuana have a significant online presence using direct-to-consumer advertising to attract stem-cell tourism clientele in a bustling border region between Mexico and the USA. This study adds to existing literature evidencing the unregulated nature of online stem cell offerings and provides further evidence of the need for regulatory harmonization, particularly to address stem cell services being offered online across borders.


  • Open Access

    Respiratory Volume Monitoring: A Machine-Learning Approach to the Non-Invasive Prediction of Tidal Volume and Minute Ventilation

    by Daniel E. Hurtado, Javier A. P. Chavez, Roberto Mansilla, Roberto Lopez, Angel Abusleme

    Continuous monitoring of ventilatory parameters such as tidal volume (TV) and minute ventilation (MV) has shown to be effective in the prevention of respiratory compromise events in hospitalized patients. However, the non-invasive estimation of respiratory volume in non-intubated patients remains an outstanding challenge. In this work, we present a novel approach to respiratory volume monitoring (RVM) that continuously predicts TV and MV in normal subjects. Respiratory flow in 19 volunteers under spontaneous breathing was recorded using respiratory inductance plethysmography and a temperature-based wearable sensor. Temperature signals were processed to identify features such as temperature amplitude and mean value, among others. The feature datasets were then used to train and validate three machine-learning (ML) algorithms for the prediction of respiratory volume based on temperature-related features. A model based on Random-Forest regression resulted in the lowest root mean-square error and was subsequently chosen to predict ventilatory parameters on subject test data not used in the construction of the model. Our predictions achieve a bias (mean error) in TV and MV of 16.04 mL and 0.19 L/min, respectively, which compare well with performance metrics reported in commercially-available RVM systems based on electrical impedance. Our results show that the combination of novel respiratory temperature sensors and machine-learning algorithms can deliver accurate and continuous estimates of TV and MV in healthy subjects.