Ya Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ya Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Lei Zhang
Key Laboratory of Micro/Nano Devices and Systems, Ministry of Education, North University of China, Taiyuan 030051, China
3 shared publications - Qiulin Tan
North University of China
3 shared publications - Baimao Lin
Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan 030051, China
1 shared publication - Baimao Lin
Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan, China
1 shared publication Baoyong Zhao
University of Science and Technology Beijing
1 shared publication- Guangjin Zhang
Key Laboratory of Instrumentation Science & Dynamic Measurement, Ministry of Education, North University of China, Taiyuan, China
1 shared publication
Latest Publications
- 30 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (4) , 3074-3079
Wireless Passive Flexible Strain Sensor Based on Aluminium Nitride Film
Rolling bearings are important components of a mechanical structure; their state directly affects the operation of the whole mechanical system. To accurately and reliably evaluate the damage state of bearings, a wireless passive flexible strain sensor based on an aluminium nitride (AlN) film was proposed in this paper. The sensor was connected to the system using a plane inductor and an interdigital capacitor to form an LC loop, and the AlN film was deposited in the interdigital capacitor part to enhance the sensing performance. The structure of the sensor was optimised using a high-frequency structure simulator (HFSS), and the optimal coupling distance between the sensor and antenna was determined. The test results revealed that the resonant frequency of the sensor increases from 43.7089 to 43.735 MHz in a strain range of 0–$3000 ~\mu \varepsilon $ , and strain resolution is$20 ~\mu \varepsilon $ . Moreover, the wireless strain sensor has a small size and high resolution. The flexible substrate can stick well to the part to be tested and can be applied to the bearing to detect micro-strain. Therefore, this sensor is applicable in fault prevention, condition monitoring, and non-destructive evaluation.- 30 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (4) , 3074-3079
Wireless Passive Flexible Strain Sensor Based on Aluminium Nitride Film
Rolling bearings are important components of a mechanical structure; their state directly affects the operation of the whole mechanical system. To accurately and reliably evaluate the damage state of bearings, a wireless passive flexible strain sensor based on an aluminium nitride (AlN) film was proposed in this paper. The sensor was connected to the system using a plane inductor and an interdigital capacitor to form an LC loop, and the AlN film was deposited in the interdigital capacitor part to enhance the sensing performance. The structure of the sensor was optimised using a high-frequency structure simulator (HFSS), and the optimal coupling distance between the sensor and antenna was determined. The test results revealed that the resonant frequency of the sensor increases from 43.7089 to 43.735 MHz in a strain range of 0–$3000 ~\mu \varepsilon $ , and strain resolution is$20 ~\mu \varepsilon $ . Moreover, the wireless strain sensor has a small size and high resolution. The flexible substrate can stick well to the part to be tested and can be applied to the bearing to detect micro-strain. Therefore, this sensor is applicable in fault prevention, condition monitoring, and non-destructive evaluation.- Open Access
- 30 December 2020
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 34
Wireless Passive LC Temperature and Strain Dual-Parameter Sensor
There is an increasing demand for bearing temperature and strain monitoring in high-speed rotating systems. This study proposes a new multiresonance, multiplexing, wireless, passive inductance capacitance (LC) temperature and strain sensor. The sensor has two capacitors connected at different locations (turns) on the same inductor to achieve simultaneous temperature and strain measurements. The plate capacitor is connected to the inner part of the inductor and the other interdigital capacitor is connected to the outer part of the inductor to form two LC loops. The structure of the sensor is optimized through High Frequency Structure Simulator (HFSS) simulations to realize frequency separation of the two parameters and avoid mutual interference between the two signals. The sensor is fabricated on a polyimide film using electroplating technology. The experimental results show that the temperature–strain sensor can operate stably from 25 °C to 85 °C with an average sensitivity of 27.3 kHz/°C within this temperature range. The sensor can detect strains in the range of 1000–5000 με with a strain sensitivity of 100 Hz/με at 25 °C. Therefore, the proposed wireless passive LC temperature-strain sensor exhibits stable performance. In addition, the use of a single inductor effectively reduces the sensor’s area. The flexible substrate provides advantageous surface conformal attachment characteristics suitable for monitoring high-temperature rotating parts in adverse environments.
- 30 December 2020
- Published by MDPI AG in Micromachines
- Vol. 12 (1) , 34
Open AccessWireless Passive LC Temperature and Strain Dual-Parameter Sensor
There is an increasing demand for bearing temperature and strain monitoring in high-speed rotating systems. This study proposes a new multiresonance, multiplexing, wireless, passive inductance capacitance (LC) temperature and strain sensor. The sensor has two capacitors connected at different locations (turns) on the same inductor to achieve simultaneous temperature and strain measurements. The plate capacitor is connected to the inner part of the inductor and the other interdigital capacitor is connected to the outer part of the inductor to form two LC loops. The structure of the sensor is optimized through High Frequency Structure Simulator (HFSS) simulations to realize frequency separation of the two parameters and avoid mutual interference between the two signals. The sensor is fabricated on a polyimide film using electroplating technology. The experimental results show that the temperature–strain sensor can operate stably from 25 °C to 85 °C with an average sensitivity of 27.3 kHz/°C within this temperature range. The sensor can detect strains in the range of 1000–5000 με with a strain sensitivity of 100 Hz/με at 25 °C. Therefore, the proposed wireless passive LC temperature-strain sensor exhibits stable performance. In addition, the use of a single inductor effectively reduces the sensor’s area. The flexible substrate provides advantageous surface conformal attachment characteristics suitable for monitoring high-temperature rotating parts in adverse environments.
- 15 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Temperature and Pressure Composite Measurement System Based on Wireless Passive LC Sensor
In this article, we proposed a measurement system that can simultaneously measure temperature and pressure. By analyzing several existing measurement methods of the sensor, we determined that the resonance frequency and S 11 (reflection coefficient) amplitude of the sensor readout system should be measured when the resonance frequency of the sensor up to a hundred megahertz or even gigahertz and when the sensor works in ultrahigh temperature environment. In addition, we designed a simple and accurate sensor readout circuit and an LC temperature-pressure sensor. By analyzing the resonance frequency and the amplitude of S 11 , temperature and pressure were measured simultaneously with a single LC circuit. Since the analysis of the whole nonlinear system of sensors is complex, we divide the entire nonlinear system into several linear systems superposition. By analyzing the interference between temperature and pressure, we further optimized the measurement method. The relative errors of the temperature measurements in the range of 25 °C-300 °C and 300 °C-1000 °C were only 2.89% and 1.25%, respectively. From 25 °C to 300 °C and 300 °C to 1000 °C, the average relative errors of pressure measurement were only 4.07% and 4.74%, respectively. Besides, the proposed method can also be widely used in the measurement of LC multiparameter sensors.
- 15 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Temperature and Pressure Composite Measurement System Based on Wireless Passive LC Sensor
In this article, we proposed a measurement system that can simultaneously measure temperature and pressure. By analyzing several existing measurement methods of the sensor, we determined that the resonance frequency and S 11 (reflection coefficient) amplitude of the sensor readout system should be measured when the resonance frequency of the sensor up to a hundred megahertz or even gigahertz and when the sensor works in ultrahigh temperature environment. In addition, we designed a simple and accurate sensor readout circuit and an LC temperature-pressure sensor. By analyzing the resonance frequency and the amplitude of S 11 , temperature and pressure were measured simultaneously with a single LC circuit. Since the analysis of the whole nonlinear system of sensors is complex, we divide the entire nonlinear system into several linear systems superposition. By analyzing the interference between temperature and pressure, we further optimized the measurement method. The relative errors of the temperature measurements in the range of 25 °C-300 °C and 300 °C-1000 °C were only 2.89% and 1.25%, respectively. From 25 °C to 300 °C and 300 °C to 1000 °C, the average relative errors of pressure measurement were only 4.07% and 4.74%, respectively. Besides, the proposed method can also be widely used in the measurement of LC multiparameter sensors.
- 1 November 2016
- Published by Springer Nature in Journal of Central South University
- Vol. 23 (11) , 2747-2753
Enhanced dielectric permittivity of graphite oxide/polyimide composite films
- 1 November 2016
- Published by Springer Nature in Journal of Central South University
- Vol. 23 (11) , 2747-2753
Enhanced dielectric permittivity of graphite oxide/polyimide composite films
- 8 November 2015
- Published by Springer Nature
- p. 393-402
Improved Robust Multiple Model Adaptive Control of the Two-Cart Mass-Spring-Damper System with Uncertainties
- 8 November 2015
- Published by Springer Nature
- p. 393-402
Improved Robust Multiple Model Adaptive Control of the Two-Cart Mass-Spring-Damper System with Uncertainties