GZGe Zheng

Ge Zheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ge Zheng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Review of Risk Assessment for Distribution Systems

    by Jie Chen, Wanxing Sheng, Xiaohui Song, Ge Zheng, Lingyun Gu, Shilei Guan


  • Concurrent Measurement of the Size Distribution and Velocity of Pneumatically Conveyed Biomass Solids Using Acoustic Emission and Electrostatic Sensors

    by Ge Zheng, Yong Yan, Lijuan Wang, Yonghui Hu, Xingxing Zeng

    In biomass fired power plants accurate measurement of the size distribution and velocity of biomass solids in pneumatic conveying pipelines feeding the burners is essential to maintain high combustion efficiency and reduce pollutant emissions. In this article, a new method for the size distribution and velocity concurrent measurement of biomass solids through acoustic emission (AE) detection and electrostatic sensing is proposed. When an AE waveguide protrudes into a biomass fuel pipe, an AE signal is generated due to the impact of biomass on the waveguide. In consideration of the inelastic and irregular characteristics of biomass fuels, the Stronge model is introduced to describe the inelastic impact process. The relationship between the statistical value of equivalent impact size and the shape characteristics of irregular shaped solids is analyzed. Meanwhile, the velocity of biomass fuel is determined by processing the signals from arc-shaped electrostatic sensor arrays. The fusion of the peak amplitude of the AE signal and biomass velocity allows the measurement of biomass size distribution. Experimental tests with crushed wheat straw, sawdust and corncob were conducted on a laboratory-scale pneumatic conveying test rig to assess the effectiveness of the size distribution measurement technique. The experimental results demonstrate that the measured biomass velocity varies with the air velocity and the transport capacity of the conveying air to biomass solids depends on factors such as shape and size distributions of biomass fuels. The relative error of the measured mean biomass size is within ± 6.45% under all test conditions with a standard deviation within 2.15%.


  • Online Measurement of the Size Distribution of Pneumatically Conveyed Particles Through Acoustic Emission Detection and Triboelectric Sensing

    by Ge Zheng, Yong Yan, Yonghui Hu, Wenbiao Zhang

    In a thermal power plant, online measurement of the size distribution of pneumatically conveyed pulverized fuel is essential for the improvement of combustion efficiency and the reduction of pollutant emissions. In this article, an innovative instrumentation system based on acoustic emission (AE) detection and triboelectric sensing is proposed for the on-line continuous measurement of particle size distribution. With a waveguide protruding into the flow, the AE signal is generated from the impacts of particles with the waveguide. The peak voltage of the AE signal is related to the particle size and impact velocity. For the first time, two triboelectric sensor arrays each with three arc-shaped electrodes near to the waveguide are used to measure the impact velocity. Meanwhile, a novel particle sizing algorithm with Gaussian prediction is proposed to reduce the effect of overlapping impacts and environmental noise on the peak distribution. With the known impact velocity measured from the triboelectric sensor arrays and the modified peak distribution, the measurement of particle size distribution is achieved. Experimental tests were conducted on a gas–solids two-phase flow rig to assess the performance of the developed measurement system. Silica sands in three size ranges of 116–750, 61–395, and 10– $246~\mu \text{m}$ , respectively, were used as test particles. The experimental results demonstrate that Spearman’s rank correlation coefficients between the measured and reference size distributions for all test particles are all greater than 0.8, while the discrepancy for each particle size segment is within ±4.8%.


  • Mass-Flow-Rate Measurement of Pneumatically Conveyed Particles Through Acoustic Emission Detection and Electrostatic Sensing

    by Ge Zheng, Yong Yan, Yonghui Hu, Wenbiao Zhang, Long Yang, Lanqi Li

    Accurate online mass flow rate measurement of pneumatically conveyed particles is desirable to convert a conventional pulverized fuel-fired power station into a smart thermal power plant. This article presents a novel method for the online measurement of the mass flow rate of pulverized fuel through acoustic emission (AE) detection and electrostatic sensing. An integrated sensing head with an AE probe and three sets of electrostatic sensor arrays is developed. The proposed method determines the particle velocity by multichannel cross correlation of the electrostatic signals and extracts the information about mass flow rate from the AE signal arising from impacts of particles with a waveguide protruding into the flow. An analytical model that relates the energy of the AE signals, the particle velocity, and the mass flow rate is established. The sensing head was mounted on the vertical and horizontal sections of a 72-mm bore laboratory-scale test rig conveying fine silica particles. Experimental tests were conducted under a range of flow conditions and installation orientations to assess the performance of the developed measurement system. The results demonstrate that the sensing head should be installed in any orientation away from the elbow on the vertical section of a pipe, while for installation on a horizontal pipe, the waveguide should be in the horizontal direction. The instrumentation system is capable of measuring the mass flow rate of particles in the vertical pipe with a relative error within ±6.5% regardless of the orientation of the sensing head over the mass flow rate from 7 to 25 kg/h and the particle velocity from 12 to 30 m/s, while on the horizontal pipe, the error is within 5.8% when the sensing head is installed with the waveguide in the horizontal direction under the same flow conditions.