Antti Immonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Antti Immonen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Mikko Kuisma
LUT University Lappeenranta Finland
5 shared publications - Pertti Silventoinen
LUT School of Energy Systems, LUT University, Lappeenranta, Finland
5 shared publications - Heikki Kyröläinen
Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland
3 shared publications - Heikki Peltonen
Biology of Physical Activity, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland
3 shared publications - Saku Levikari
Department of Electrical Engineering LUT University Lappeenranta Finland
3 shared publications - Feng Gao
Chipmetrics Ltd. 2 , Yliopistokatu 7, Joensuu 80130
2 shared publications
Latest Publications
- Open Access
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 35590-35598
Thermal Measurement of Arterial Pulse Using Heat Flux Sensors
In this paper, the novel concept of using heat flux sensors (HFS) to measure arterial pulse on the skin surface is validated. The heat flux (HF) signal is compared with simultaneously measured electrocardiogram (ECG) and photoplethysmography (PPG) signals during both rest and initial recovery from exercise. It is found that the waveform measured with the HF sensor above the radial artery has similar shape to PPG and demonstrates a clear temporal alignment between the HF pulse waves and both the PPG and ECG signals. Further, it is shown that HF measurement can be used to consistently track the arterial pulse at varying skin-to-ambient temperature gradients.
- 4 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 35590-35598
Open AccessThermal Measurement of Arterial Pulse Using Heat Flux Sensors
In this paper, the novel concept of using heat flux sensors (HFS) to measure arterial pulse on the skin surface is validated. The heat flux (HF) signal is compared with simultaneously measured electrocardiogram (ECG) and photoplethysmography (PPG) signals during both rest and initial recovery from exercise. It is found that the waveform measured with the HF sensor above the radial artery has similar shape to PPG and demonstrates a clear temporal alignment between the HF pulse waves and both the PPG and ECG signals. Further, it is shown that HF measurement can be used to consistently track the arterial pulse at varying skin-to-ambient temperature gradients.
- Open Access
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Thermal Measurement of Arterial Pulse using Heat Flux Sensors
In this paper, the novel concept of using heat flux sensors (HFS) to measure arterial pulse on the skin surface is validated. The heat flux (HF) signal is compared with simultaneously measured electrocardiogram (ECG) and photoplethysmography (PPG) signals during both rest and initial recovery from exercise. It is found that the waveform measured with the HF sensor above the radial artery has similar shape to PPG and demonstrates a clear temporal alignment between the HF pulse waves and both the PPG and ECG signals. Further, it is shown that HF measurement can be used to consistently track the arterial pulse at varying skin-to-ambient temperature gradients.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessThermal Measurement of Arterial Pulse using Heat Flux Sensors
In this paper, the novel concept of using heat flux sensors (HFS) to measure arterial pulse on the skin surface is validated. The heat flux (HF) signal is compared with simultaneously measured electrocardiogram (ECG) and photoplethysmography (PPG) signals during both rest and initial recovery from exercise. It is found that the waveform measured with the HF sensor above the radial artery has similar shape to PPG and demonstrates a clear temporal alignment between the HF pulse waves and both the PPG and ECG signals. Further, it is shown that HF measurement can be used to consistently track the arterial pulse at varying skin-to-ambient temperature gradients.
- Open Access
- 22 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Improving Energy Expenditure Estimation in Wrist-Worn Wearables by Augmenting Heart Rate Data With Heat Flux Measurement
Wearable electronics are often used for estimating the energy expenditure of the user based on heart rate measurement. While heart rate is a good predictor of calorie consumption at high intensities, it is less precise at low intensity levels, which translates into inaccurate results when estimating daily net energy expenditure. In this study, heart rate measurement was augmented with heat flux (HF) measurement, a form of direct calorimetry. A physical exercise test on a group of 15 people showed that HF measurement can improve the accuracy of calorie consumption estimates especially during rest and low-intensity activity when used in conjunction with heart rate information and vital background parameters of the user.
- 22 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Open AccessImproving Energy Expenditure Estimation in Wrist-Worn Wearables by Augmenting Heart Rate Data With Heat Flux Measurement
Wearable electronics are often used for estimating the energy expenditure of the user based on heart rate measurement. While heart rate is a good predictor of calorie consumption at high intensities, it is less precise at low intensity levels, which translates into inaccurate results when estimating daily net energy expenditure. In this study, heart rate measurement was augmented with heat flux (HF) measurement, a form of direct calorimetry. A physical exercise test on a group of 15 people showed that HF measurement can improve the accuracy of calorie consumption estimates especially during rest and low-intensity activity when used in conjunction with heart rate information and vital background parameters of the user.
- Open Access
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Development of a Vertically Configured MEMS Heat Flux Sensor
Heat flux sensors have potential in enabling applications that require direct and instantaneous tracking of thermal energy transfer. To facilitate widespread use of the sensors, the sensors have to be robust and feasible to implement, while maintaining high sensitivity, fast response time, and low thermal obtrusiveness. However, most currently available heat flux sensors are either challenging to manufacture or ill-suited for surface heat flux measurement because of their mechanical or thermal characteristics. In this paper, the design of a novel MEMS heat flux sensor structure intended for surface heat flux measurements is presented. A prototype batch is manufactured and the electrical performance of the prototype sensors is compared with commercially available heat flux sensors. Results show that sensors with a similar sensitivity as commercial sensors can be made by using MEMS methods.
- 30 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Open AccessDevelopment of a Vertically Configured MEMS Heat Flux Sensor
Heat flux sensors have potential in enabling applications that require direct and instantaneous tracking of thermal energy transfer. To facilitate widespread use of the sensors, the sensors have to be robust and feasible to implement, while maintaining high sensitivity, fast response time, and low thermal obtrusiveness. However, most currently available heat flux sensors are either challenging to manufacture or ill-suited for surface heat flux measurement because of their mechanical or thermal characteristics. In this paper, the design of a novel MEMS heat flux sensor structure intended for surface heat flux measurements is presented. A prototype batch is manufactured and the electrical performance of the prototype sensors is compared with commercially available heat flux sensors. Results show that sensors with a similar sensitivity as commercial sensors can be made by using MEMS methods.
- Open Access
MEMS Heat Flux Sensor
Heat flux sensors have potential in enabling applications that require tracking of direct and instantaneous thermal energy transfer. To facilitate their use, the sensors have to be robust and feasible to implement, while maintaining high sensitivity and a fast response time. However, most commercially available heat flux sensors are expensive to manufacture and have insufficient temporal responses. In this paper, a novel microelectromechanical heat flux sensor structure is proposed. The electrical performance of the prototype sensors is compared with commercially available heat flux sensors. Preliminary results show that our sensors have similar sensitivity and faster response compared to commercial sensors.
Open AccessMEMS Heat Flux Sensor
Heat flux sensors have potential in enabling applications that require tracking of direct and instantaneous thermal energy transfer. To facilitate their use, the sensors have to be robust and feasible to implement, while maintaining high sensitivity and a fast response time. However, most commercially available heat flux sensors are expensive to manufacture and have insufficient temporal responses. In this paper, a novel microelectromechanical heat flux sensor structure is proposed. The electrical performance of the prototype sensors is compared with commercially available heat flux sensors. Preliminary results show that our sensors have similar sensitivity and faster response compared to commercial sensors.
- Open Access
Improving Energy Expenditure Estimation in Wearables using a Heat Flux Sensor: First Observations
Wearable electronics are often used for estimating the energy expenditure of the user based on heart rate measurement. While heart rate is a good predictor of calorie consumption at high intensities, it is less precise at low intensity levels, which translates into inaccurate results when estimating daily net energy expenditure. In this study, heart rate measurement was augmented with heat flux measurement, a form of direct calorimetry. A physical exercise test on a group of 15 people showed that heat flux measurement can significantly improve the accuracy of calorie consumption estimates when used in conjunction with heart rate information and vital background parameters of the user.
Open AccessImproving Energy Expenditure Estimation in Wearables using a Heat Flux Sensor: First Observations
Wearable electronics are often used for estimating the energy expenditure of the user based on heart rate measurement. While heart rate is a good predictor of calorie consumption at high intensities, it is less precise at low intensity levels, which translates into inaccurate results when estimating daily net energy expenditure. In this study, heart rate measurement was augmented with heat flux measurement, a form of direct calorimetry. A physical exercise test on a group of 15 people showed that heat flux measurement can significantly improve the accuracy of calorie consumption estimates when used in conjunction with heart rate information and vital background parameters of the user.