Andrew John Timperley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrew John Timperley has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Sarah L. Whitehouse
Queensland Unit for Advanced Shoulder Research (QUASR), Queensland University of Technology, Brisbane, QLD, Australia
5 shared publications - Göran Garellick
Swedish Hip Arthroplasty Register, Gothenburg, Sweden.
2 shared publications - Johan Kärrholm
The Swedish Arthroplasty Register; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
2 shared publications - Jonathan R. Howell
Exeter Hip Unit, Princess Elizabeth Orthopaedic Centre, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, UK
2 shared publications - Matthew J. W. Hubble
Exeter Hip Unit, Princess Elizabeth Orthopaedic Centre, Royal Devon University Healthcare NHS Foundation Trust, Barrack Road, Exeter, UK
2 shared publications - Maziar Mohaddes
Department of Orthopaedics, Institute of Clinical Sciences, University of Gothenburg, Gothenburg, Sweden
2 shared publications
Latest Publications
- 19 August 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_16) , 30
A STANDARD OF CARE IN HIP ARTHROPLASTY: ROUTINE USE OF THE TENDON-SPARING SPAIRE TECHNIQUE WITH MAKO ROBOTIC ASSISTANCE
The SPAIRE technique (Saving Piriformis And Internus, Repair Externus) was first described in 2016 and an approach to the hip in the interval between the inferior gemellus and quadratus femoris can be used for both hemi- and total hip arthroplasty.The HemiSPAIRE technique in hip hemiarthroplasty for displaced intracapsular fractures has been compared with the standard lateral approach (advocated by NICE) in a pragmatic, superiority, multicentre, randomised controlled trial into postoperative mobility and function. This NIHR funded study was recruited between November 2019 and April 2022 and the results are reported in this presentation.The author has used the SPAIRE technique in 1026 routine primary total hip replacements since February 2016. The technique is described along with results from NJR data.SPAIRE is most challenging in patients with small anatomy, reduced offset, with an external rotation deformity. Particularly in these, but in all cases, MAKO robotic assistance facilitates accurate implantation of prostheses and precise recreation of biomechanics. The MAKO robot has been used in all cases since 2018 and SPAIRE/MAKO is now the standard of care in the author's practice.To evaluate whether robotic-assisted tendon-sparing posterior approaches (piriformis sparing and SPAIRE), improve patient outcomes in total hip arthroplasty compared with a robotic-assisted standard posterior approach, the NIHR Efficacy and Mechanism Evaluation Programme has recently funded the HIPSTER trial (HIP Surgical Techniques to Enhance Rehabilitation). This is a single-centre, double-blinded, parallel three-arm, randomised, controlled, superiority trial; recruitment is in progress.The greatest value of robotic assistance may be when it is used in combination with tendon-sparing surgery. Data is being gathered to evaluate whether the SPAIRE/MAKO technique confers benefits with regard the speed of post-op mobilisation as well as accelerated return to unrestricted function.
- 19 August 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_16) , 30
A STANDARD OF CARE IN HIP ARTHROPLASTY: ROUTINE USE OF THE TENDON-SPARING SPAIRE TECHNIQUE WITH MAKO ROBOTIC ASSISTANCE
The SPAIRE technique (Saving Piriformis And Internus, Repair Externus) was first described in 2016 and an approach to the hip in the interval between the inferior gemellus and quadratus femoris can be used for both hemi- and total hip arthroplasty.The HemiSPAIRE technique in hip hemiarthroplasty for displaced intracapsular fractures has been compared with the standard lateral approach (advocated by NICE) in a pragmatic, superiority, multicentre, randomised controlled trial into postoperative mobility and function. This NIHR funded study was recruited between November 2019 and April 2022 and the results are reported in this presentation.The author has used the SPAIRE technique in 1026 routine primary total hip replacements since February 2016. The technique is described along with results from NJR data.SPAIRE is most challenging in patients with small anatomy, reduced offset, with an external rotation deformity. Particularly in these, but in all cases, MAKO robotic assistance facilitates accurate implantation of prostheses and precise recreation of biomechanics. The MAKO robot has been used in all cases since 2018 and SPAIRE/MAKO is now the standard of care in the author's practice.To evaluate whether robotic-assisted tendon-sparing posterior approaches (piriformis sparing and SPAIRE), improve patient outcomes in total hip arthroplasty compared with a robotic-assisted standard posterior approach, the NIHR Efficacy and Mechanism Evaluation Programme has recently funded the HIPSTER trial (HIP Surgical Techniques to Enhance Rehabilitation). This is a single-centre, double-blinded, parallel three-arm, randomised, controlled, superiority trial; recruitment is in progress.The greatest value of robotic assistance may be when it is used in combination with tendon-sparing surgery. Data is being gathered to evaluate whether the SPAIRE/MAKO technique confers benefits with regard the speed of post-op mobilisation as well as accelerated return to unrestricted function.
- Open Access
- 1 March 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (3) , 196-204
Is rationing of total hip arthroplasty justified? Working to optimize patient accessibility to surgery using long-term patient-reported outcome data
Aims The aim of this study was to assess medium-term improvements following total hip arthroplasty (THA), and to evaluate what effect different preoperative Oxford Hip Score (OHS) thresholds for treatment may have on patients’ access to THA and outcomes. Methods Patients undergoing primary THA at our institution with an OHS both preoperatively and at least four years postoperatively were included. Rationing thresholds were explored to identify possible deprivation of OHS improvement. Results Overall, 2,341 patients were included. Mean OHS was 19.7 (SD 8.2) preoperatively and 39.7 (SD 9.8) at latest follow-up. An improvement of at least eight-points, the minimally important change (MIC), was seen in 2,072 patients (88.5%). The mean improvement was 20.0 points (SD 10.5). If a rationing threshold of OHS of 20 points had been enforced, 90.8% of those treated would have achieved the MIC, but only 54.3% of our cohort would have had access to surgery; increasing this threshold to 32 would have enabled 89.5% of those treated to achieve the MIC while only depriving 6.5% of our cohort. The ‘rationed’ group of OHS > 20 had significantly better OHS at latest follow-up (42.6 vs 37.3; p < 0.001), while extending the rationing threshold above 32 showed postoperative scores were more significantly affected by the ceiling effect of the OHS. Conclusion The OHS was not designed as a tool to ration healthcare, but if it had been used at our institution for this cohort, applying an OHS threshold of 20 to routine THA access would have excluded nearly half of patients from having a THA; a group in which over 85% had a significant improvement in OHS. Where its use for rationing is deemed necessary, use of a higher threshold may be more appropriate to ensure a better balance between patient access to treatment and chances of achieving good to excellent outcomes. Cite this article: Bone Jt Open 2022;3(3):196–204.
- 1 March 2022
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (3) , 196-204
Open AccessIs rationing of total hip arthroplasty justified? Working to optimize patient accessibility to surgery using long-term patient-reported outcome data
Aims The aim of this study was to assess medium-term improvements following total hip arthroplasty (THA), and to evaluate what effect different preoperative Oxford Hip Score (OHS) thresholds for treatment may have on patients’ access to THA and outcomes. Methods Patients undergoing primary THA at our institution with an OHS both preoperatively and at least four years postoperatively were included. Rationing thresholds were explored to identify possible deprivation of OHS improvement. Results Overall, 2,341 patients were included. Mean OHS was 19.7 (SD 8.2) preoperatively and 39.7 (SD 9.8) at latest follow-up. An improvement of at least eight-points, the minimally important change (MIC), was seen in 2,072 patients (88.5%). The mean improvement was 20.0 points (SD 10.5). If a rationing threshold of OHS of 20 points had been enforced, 90.8% of those treated would have achieved the MIC, but only 54.3% of our cohort would have had access to surgery; increasing this threshold to 32 would have enabled 89.5% of those treated to achieve the MIC while only depriving 6.5% of our cohort. The ‘rationed’ group of OHS > 20 had significantly better OHS at latest follow-up (42.6 vs 37.3; p < 0.001), while extending the rationing threshold above 32 showed postoperative scores were more significantly affected by the ceiling effect of the OHS. Conclusion The OHS was not designed as a tool to ration healthcare, but if it had been used at our institution for this cohort, applying an OHS threshold of 20 to routine THA access would have excluded nearly half of patients from having a THA; a group in which over 85% had a significant improvement in OHS. Where its use for rationing is deemed necessary, use of a higher threshold may be more appropriate to ensure a better balance between patient access to treatment and chances of achieving good to excellent outcomes. Cite this article: Bone Jt Open 2022;3(3):196–204.
- 1 January 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (1) , 71-78
B2 or not B2? That is the question: a review of periprosthetic fractures around cemented taper-slip femoral components
Aims: Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification.Methods: We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment.Results: In total, 47 B2W fractures (54.0%) and one B3 fracture (1.1%) had cement that remained well-fixed at the cement-bone interface. These cases were treated with cement-in-cement (CinC) revision arthroplasty. Overall, 43 fractures with follow-up united, and two patients sustained further fractures secondary to nonunion and required further revision surgery. A total of 19 B2L fractures (21.8%) and 19 B3 fractures (21.8%) had cement that was loose at the cement-bone interface. These cases were managed by revision arthroplasty with either cemented or uncemented femoral components, or proximal femoral arthroplasty. One case could not be classified.Conclusion: We endorse a modification of the original Vancouver system to include a subclassification of B2 fractures around cemented femoral prostheses to include B2W (where cement is well-fixed to bone) and B2L (where the cement is loose). Fractures around taper-slip design stems are more likely to fracture in a B2W pattern compared to fractures around composite beam design stems which are more likely to fracture in a B2L pattern. B2W fractures can reliably be managed with CinC revision. Cite this article: Bone Joint J 2021;103-B(1):71–78.
- 1 January 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (1) , 71-78
B2 or not B2? That is the question: a review of periprosthetic fractures around cemented taper-slip femoral components
Aims: Periprosthetic fractures (PPFs) around cemented taper-slip femoral prostheses often result in a femoral component that is loose at the prosthesis-cement interface, but where the cement-bone interface remains well-fixed and bone stock is good. We aim to understand how best to classify and manage these fractures by using a modification of the Vancouver classification.Methods: We reviewed 87 PPFs. Each was a first episode of fracture around a cemented femoral component, where surgical management consisted of revision surgery. Data regarding initial injury, intraoperative findings, and management were prospectively collected. Patient records and serial radiographs were reviewed to determine fracture classification, whether the bone cement was well fixed (B2W) or loose (B2L), and time to fracture union following treatment.Results: In total, 47 B2W fractures (54.0%) and one B3 fracture (1.1%) had cement that remained well-fixed at the cement-bone interface. These cases were treated with cement-in-cement (CinC) revision arthroplasty. Overall, 43 fractures with follow-up united, and two patients sustained further fractures secondary to nonunion and required further revision surgery. A total of 19 B2L fractures (21.8%) and 19 B3 fractures (21.8%) had cement that was loose at the cement-bone interface. These cases were managed by revision arthroplasty with either cemented or uncemented femoral components, or proximal femoral arthroplasty. One case could not be classified.Conclusion: We endorse a modification of the original Vancouver system to include a subclassification of B2 fractures around cemented femoral prostheses to include B2W (where cement is well-fixed to bone) and B2L (where the cement is loose). Fractures around taper-slip design stems are more likely to fracture in a B2W pattern compared to fractures around composite beam design stems which are more likely to fracture in a B2L pattern. B2W fractures can reliably be managed with CinC revision. Cite this article: Bone Joint J 2021;103-B(1):71–78.
- Open Access
- 6 March 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (3) , 214-219
Not all cemented hips are the same: a register-based (NJR) comparison of taper-slip and composite beam femoral stems
Background and purpose — No difference in outcome has been demonstrated comparing cemented taper-slip and composite beam designs in short-term randomised trials; we assessed outcome differences using a registry analysis. Patients and methods — All cemented stems with > 100 implantations were identified in the National Joint Registry of England and Wales from April 1, 2003 to September 31, 2013 and categorised as taper-slip or composite beam. Survival analyses using Kaplan–Meier and Cox regression were performed. Results — We identified 292,987 cemented arthroplasties, of which 16% (47,586) were composite beam stems, with taper-slip stems making up the remainder (n = 245,401). There was a statistically significant increased chance of revision in the composite beam group compared with the taper-slip group (1.7% vs 1.3%, p < 0.001) but statistically no significant differences of survival estimates (p = 0.06). When the 2 groups were segregated to delineate the most implanted model in each category, the differences became more profound with the most implanted taper-slip stem (Exeter V40) showing statistically and clinically significant superior 8-year survival: 97.9% compared with 97.6% for all other taper-slip; 97.5% for the most implanted composite beam (Charnley cemented stem); and 97.7% for all other composite beam. Interpretation — There was an increased incidence of revision for composite beam stems. The most implanted taper-slip stem demonstrated significant survival advantage vs. all other stems.
- 6 March 2019
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 90 (3) , 214-219
Open AccessNot all cemented hips are the same: a register-based (NJR) comparison of taper-slip and composite beam femoral stems
Background and purpose — No difference in outcome has been demonstrated comparing cemented taper-slip and composite beam designs in short-term randomised trials; we assessed outcome differences using a registry analysis. Patients and methods — All cemented stems with > 100 implantations were identified in the National Joint Registry of England and Wales from April 1, 2003 to September 31, 2013 and categorised as taper-slip or composite beam. Survival analyses using Kaplan–Meier and Cox regression were performed. Results — We identified 292,987 cemented arthroplasties, of which 16% (47,586) were composite beam stems, with taper-slip stems making up the remainder (n = 245,401). There was a statistically significant increased chance of revision in the composite beam group compared with the taper-slip group (1.7% vs 1.3%, p < 0.001) but statistically no significant differences of survival estimates (p = 0.06). When the 2 groups were segregated to delineate the most implanted model in each category, the differences became more profound with the most implanted taper-slip stem (Exeter V40) showing statistically and clinically significant superior 8-year survival: 97.9% compared with 97.6% for all other taper-slip; 97.5% for the most implanted composite beam (Charnley cemented stem); and 97.7% for all other composite beam. Interpretation — There was an increased incidence of revision for composite beam stems. The most implanted taper-slip stem demonstrated significant survival advantage vs. all other stems.
- Open Access
- 6 February 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 1-8
Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty
Patient reported outcome measurement (PROMs) will not capture in detail the functional joint motion before and after total hip arthroplasty (THA). Therefore, methods more specifically aimed to analyse joint movements may be of interest. An analysis method that addresses these issues should be readily accessible and easy to use especially if applied to large groups of patients, who you want to study both before and after a surgical intervention such as THA. Our aim was to evaluate the accuracy of inertial measurement units (IMU) by comparison with an optical tracking system (OTS) to record pelvic tilt, hip and knee flexion in patients who had undergone THA. 49 subjects, 25 males 24 females, mean age of 73 years (range 51–80) with THA participated. All patients were measured with a portable IMU system, with sensors attached lateral to the pelvis, the thigh and the lower leg. For validation, a 12-camera motion capture system was used to determine the positions of 15 skin markers (Oqus 4, Qualisys AB, Sweden). Comparison of sagittal pelvic rotations, and hip and knee flexion-extension motions measured with the two systems was performed. The mean values of the IMU’s on the left and right sides were compared with OTS data. The comparison between the two gait analysis methods showed no significant difference for mean pelvic tilt range (4.9–5.4 degrees) or mean knee flexion range (54.4–55.1 degrees) on either side (p > 0.7). The IMU system did however record slightly less hip flexion on both sides (36.7–37.7 degrees for the OTS compared to 34.0–34.4 degrees for the IMU, p < 0.001). We found that inertial measurement units can produce valid kinematic data of pelvis- and knee flexion-extension range. Slightly less hip flexion was however recorded with the inertial measurement units which may be due to the difference in the modelling of the pelvis, soft tissue artefacts, and malalignment between the two methods or misplacement of the inertial measurement units. The study has ethical approval from the ethical committee “Regionala etikprövningsnämnden i Göteborg” (Dnr: 611–15, 2015-08-27) and all study participants have submitted written approval for participation in the study.
- 6 February 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 1-8
Open AccessValidation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty
Patient reported outcome measurement (PROMs) will not capture in detail the functional joint motion before and after total hip arthroplasty (THA). Therefore, methods more specifically aimed to analyse joint movements may be of interest. An analysis method that addresses these issues should be readily accessible and easy to use especially if applied to large groups of patients, who you want to study both before and after a surgical intervention such as THA. Our aim was to evaluate the accuracy of inertial measurement units (IMU) by comparison with an optical tracking system (OTS) to record pelvic tilt, hip and knee flexion in patients who had undergone THA. 49 subjects, 25 males 24 females, mean age of 73 years (range 51–80) with THA participated. All patients were measured with a portable IMU system, with sensors attached lateral to the pelvis, the thigh and the lower leg. For validation, a 12-camera motion capture system was used to determine the positions of 15 skin markers (Oqus 4, Qualisys AB, Sweden). Comparison of sagittal pelvic rotations, and hip and knee flexion-extension motions measured with the two systems was performed. The mean values of the IMU’s on the left and right sides were compared with OTS data. The comparison between the two gait analysis methods showed no significant difference for mean pelvic tilt range (4.9–5.4 degrees) or mean knee flexion range (54.4–55.1 degrees) on either side (p > 0.7). The IMU system did however record slightly less hip flexion on both sides (36.7–37.7 degrees for the OTS compared to 34.0–34.4 degrees for the IMU, p < 0.001). We found that inertial measurement units can produce valid kinematic data of pelvis- and knee flexion-extension range. Slightly less hip flexion was however recorded with the inertial measurement units which may be due to the difference in the modelling of the pelvis, soft tissue artefacts, and malalignment between the two methods or misplacement of the inertial measurement units. The study has ethical approval from the ethical committee “Regionala etikprövningsnämnden i Göteborg” (Dnr: 611–15, 2015-08-27) and all study participants have submitted written approval for participation in the study.
- Open Access
- 10 August 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (8) , 899
Is Preoperative Patient-Reported Health Status Associated with Mortality after Total Hip Replacement?
The influence of comorbidities and worse physical status on mortality following total hip replacement (THR) leads to the idea that patient-reported health status may also be a predictor of mortality. The aim of this study was to investigate the relationship between patient-reported health status before THR and the risk of dying up to 5 years post-operatively. For these analyses, we used register data on 42,862 THR patients with primary hip osteoarthritis operated between 2008 and 2012. The relative survival ratio was calculated by dividing the observed survival in the patient group by age- and sex-adjusted expected survival of the general population. Pre-operative responses to the five EQ-5D-3L (EuroQol Group) dimensions along with age, sex, education status, year of surgery, and hospital type were used as independent variables. Results shown that, as a group, THR patients had a better survival than the general population. Broken down by the five EQ-5D-3L dimensions we observed differentiated survival patters. For all dimensions, those reporting extreme problems had higher mortality than those reporting moderate or no problems. In conclusion, worse health status according to the EQ-5-3L before THR is associated with higher mortality up to five years after surgery. EQ-5D-3L responses may be useful in a multifactorial individualized risk assessment before THR.
- 10 August 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (8) , 899
Open AccessIs Preoperative Patient-Reported Health Status Associated with Mortality after Total Hip Replacement?
The influence of comorbidities and worse physical status on mortality following total hip replacement (THR) leads to the idea that patient-reported health status may also be a predictor of mortality. The aim of this study was to investigate the relationship between patient-reported health status before THR and the risk of dying up to 5 years post-operatively. For these analyses, we used register data on 42,862 THR patients with primary hip osteoarthritis operated between 2008 and 2012. The relative survival ratio was calculated by dividing the observed survival in the patient group by age- and sex-adjusted expected survival of the general population. Pre-operative responses to the five EQ-5D-3L (EuroQol Group) dimensions along with age, sex, education status, year of surgery, and hospital type were used as independent variables. Results shown that, as a group, THR patients had a better survival than the general population. Broken down by the five EQ-5D-3L dimensions we observed differentiated survival patters. For all dimensions, those reporting extreme problems had higher mortality than those reporting moderate or no problems. In conclusion, worse health status according to the EQ-5-3L before THR is associated with higher mortality up to five years after surgery. EQ-5D-3L responses may be useful in a multifactorial individualized risk assessment before THR.
- 1 March 2017
- Published by SAGE Publications in HIP International
- Vol. 27 (2) , 205-209
The SPAIRE Technique Allows Sparing of the Piriformis and Obturator Internus in a Modified Posterior Approach to the Hip
Introduction: The Sparing Piriformis and Internus, Repair Externus (SPAIRE) technique allows a muscle sparing mini-posterior approach to the hip. Method: We present in this article a description of an adaptation of the familiar posterior approach (PA) in which the only tendon released is obturator externus. Termed SPAIRE, this muscle sparing technique enables preservation of the piriformis tendon and conjoint insertion of obturator internus and the gemelli. The technical description allows for safe and reliable replication by any surgeon familiar with the posterior approach (PA) to the hip without reliance on additional equipment, and without compromising the ability to convert into a more extensile approach. Conclusions: This technical description and brief discussion of rationale outlines the ongoing work of the authors in developing the SPAIRE technique as part of the spectrum of the posterior approach to the hip. The senior author now uses this technique routinely for total hip replacements and hemiarthroplasty. Patients are mobilised with no postoperative restrictions whatsoever. Other potential advantages include improved gait, more anatomical restoration of hip function, and enhanced stability. Projects have been initiated in our unit to objectively assess the possible clinical advantages relating to use of the SPAIRE technique using gait analysis, objective measurement of muscle power and studies of hip stability.
- 1 March 2017
- Published by SAGE Publications in HIP International
- Vol. 27 (2) , 205-209
The SPAIRE Technique Allows Sparing of the Piriformis and Obturator Internus in a Modified Posterior Approach to the Hip
Introduction: The Sparing Piriformis and Internus, Repair Externus (SPAIRE) technique allows a muscle sparing mini-posterior approach to the hip. Method: We present in this article a description of an adaptation of the familiar posterior approach (PA) in which the only tendon released is obturator externus. Termed SPAIRE, this muscle sparing technique enables preservation of the piriformis tendon and conjoint insertion of obturator internus and the gemelli. The technical description allows for safe and reliable replication by any surgeon familiar with the posterior approach (PA) to the hip without reliance on additional equipment, and without compromising the ability to convert into a more extensile approach. Conclusions: This technical description and brief discussion of rationale outlines the ongoing work of the authors in developing the SPAIRE technique as part of the spectrum of the posterior approach to the hip. The senior author now uses this technique routinely for total hip replacements and hemiarthroplasty. Patients are mobilised with no postoperative restrictions whatsoever. Other potential advantages include improved gait, more anatomical restoration of hip function, and enhanced stability. Projects have been initiated in our unit to objectively assess the possible clinical advantages relating to use of the SPAIRE technique using gait analysis, objective measurement of muscle power and studies of hip stability.
- 21 December 2016
- Published by Springer Nature
- p. 967-974
The Critical Role of Registries in Documenting the Outcomes of Hip Preservation Surgery
- 21 December 2016
- Published by Springer Nature
- p. 967-974
The Critical Role of Registries in Documenting the Outcomes of Hip Preservation Surgery
- Open Access
- 4 October 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 414
Linking Swedish health data registers to establish a research database and a shared decision-making tool in hip replacement
Sweden offers a unique opportunity to researchers to construct comprehensive databases that encompass a wide variety of healthcare related data. Statistics Sweden and the National Board of Health and Welfare collect individual level data for all Swedish residents that ranges from medical diagnoses to socioeconomic information. In addition to the information collected by governmental agencies the medical profession has initiated nationwide Quality Registers that collect data on specific diagnoses and interventions. The Quality Registers analyze activity within healthcare institutions, with the aims of improving clinical care and fostering clinical research. The Swedish Hip Arthroplasty Register (SHAR) has been collecting data since 1979. Joint replacement in general and hip replacement in particular is considered a success story with low mortality and complication rate. It is credited to the pioneering work of the SHAR that the revision rate following hip replacement surgery in Sweden is amongst the lowest in the world. This has been accomplished by the diligent follow-up of patients with feedback of outcomes to the providers of the healthcare along with post market surveillance of individual implant performance. During its existence SHAR has experienced a constant organic growth. One major development was the introduction of the Patient Reported Outcome Measures program, giving a voice to the patients in healthcare performance evaluation. The next aim for SHAR is to integrate patients’ wishes and expectations with the surgeons’ expertise in the form of a Shared Decision-Making (SDM) instrument. The first step in building such an instrument is to assemble the necessary data. This involves linking the SHARs database with the two aforementioned governmental agencies. The linkage is done by the 10-digit personal identity number assigned at birth (or immigration) for every Swedish resident. The anonymized data is stored on encrypted serves and can only be accessed after double identification. This data will serve as starting point for several research projects and clinical improvement work.
- 4 October 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 414
Open AccessLinking Swedish health data registers to establish a research database and a shared decision-making tool in hip replacement
Sweden offers a unique opportunity to researchers to construct comprehensive databases that encompass a wide variety of healthcare related data. Statistics Sweden and the National Board of Health and Welfare collect individual level data for all Swedish residents that ranges from medical diagnoses to socioeconomic information. In addition to the information collected by governmental agencies the medical profession has initiated nationwide Quality Registers that collect data on specific diagnoses and interventions. The Quality Registers analyze activity within healthcare institutions, with the aims of improving clinical care and fostering clinical research. The Swedish Hip Arthroplasty Register (SHAR) has been collecting data since 1979. Joint replacement in general and hip replacement in particular is considered a success story with low mortality and complication rate. It is credited to the pioneering work of the SHAR that the revision rate following hip replacement surgery in Sweden is amongst the lowest in the world. This has been accomplished by the diligent follow-up of patients with feedback of outcomes to the providers of the healthcare along with post market surveillance of individual implant performance. During its existence SHAR has experienced a constant organic growth. One major development was the introduction of the Patient Reported Outcome Measures program, giving a voice to the patients in healthcare performance evaluation. The next aim for SHAR is to integrate patients’ wishes and expectations with the surgeons’ expertise in the form of a Shared Decision-Making (SDM) instrument. The first step in building such an instrument is to assemble the necessary data. This involves linking the SHARs database with the two aforementioned governmental agencies. The linkage is done by the 10-digit personal identity number assigned at birth (or immigration) for every Swedish resident. The anonymized data is stored on encrypted serves and can only be accessed after double identification. This data will serve as starting point for several research projects and clinical improvement work.
- 5 October 2013
- Published by SAGE Publications in HIP International
- Vol. 23 (6) , 522-528
Results using Trabecular Metal™ augments in combination with acetabular impaction bone grafting in deficient acetabula
We examined whether the use of trabecular metal wedges to fill segmental defects is an effective method of socket reconstruction when used in combination with impaction grafting and implantation of a cemented socket. Fifteen hips in 14 patients underwent impaction grafting in combination with a TM wedge with a minimum of two years follow-up. All patients had their defects assessed using the Paprosky classification. Patients were reviewed with x-rays and migration of the implant was measured. Outcome scores were also collected. Mean follow-up was 39 months (25-83). The mean age at surgery was 67.8 (49-85) years. Seven of the patients had previously undergone impaction grafting with the use of a stainless steel rim mesh to constrain the graft. None of the patients had failed either clinically or radiologically.
- 5 October 2013
- Published by SAGE Publications in HIP International
- Vol. 23 (6) , 522-528
Results using Trabecular Metal™ augments in combination with acetabular impaction bone grafting in deficient acetabula
We examined whether the use of trabecular metal wedges to fill segmental defects is an effective method of socket reconstruction when used in combination with impaction grafting and implantation of a cemented socket. Fifteen hips in 14 patients underwent impaction grafting in combination with a TM wedge with a minimum of two years follow-up. All patients had their defects assessed using the Paprosky classification. Patients were reviewed with x-rays and migration of the implant was measured. Outcome scores were also collected. Mean follow-up was 39 months (25-83). The mean age at surgery was 67.8 (49-85) years. Seven of the patients had previously undergone impaction grafting with the use of a stainless steel rim mesh to constrain the graft. None of the patients had failed either clinically or radiologically.