François Brunotte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
François Brunotte has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Alan Courteau
ImViA Laboratory, EA 7535, University of Burgundy, Dijon, France
2 shared publications - Jean-Marc Vrigneaud
Centre Georges-François Leclerc, service de médecine nucléaire, CNRS, ICMUB UMR 6302, Université Bourgogne Europe, 21000, Dijon, France.
2 shared publications John McGrath
MR-Solutions Ltd, Guildford, Surrey, United Kingdom
2 shared publications- Rosie Pegg
MR-Solutions Ltd, Guildford, Surrey, United Kingdom
2 shared publications - Alain Lalande
Université Bourgogne Europe, CHU Dijon Bourgogne, Pôle Imagerie, CNRS, ICMUB UMR 6302
1 shared publication Alberto Sanchez-Pastor Gomis
MR Solutions, Guildford, Surrey, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
1 shared publication
Latest Publications
- 17 October 2022
- Published by Elsevier in Physica Medica
- Vol. 103, 98-107
Critical analysis of the effect of various methodologies to compute breast cancer tumour blood flow-based texture features using first-pass 18F-FDG PET
- 17 October 2022
- Published by Elsevier in Physica Medica
- Vol. 103, 98-107
Critical analysis of the effect of various methodologies to compute breast cancer tumour blood flow-based texture features using first-pass 18F-FDG PET
- Open Access
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (1) , 205-217
Performance Evaluation and Compatibility Studies of a Compact Preclinical Scanner for Simultaneous PET/MR Imaging at 7 Tesla
We present the design and performance of a new compact preclinical system combining positron emission tomography (PET) and magnetic resonance imaging (MRI) for simultaneous scans. The PET contains sixteen SiPM-based detector heads arranged in two octagons and covers an axial field of view (FOV) of 102.5 mm. Depth of interaction effects and detector’s temperature variations are compensated by the system. The PET is integrated in a dry magnet operating at 7 T. PET and MRI characteristics were assessed complying with international standards and interferences between both subsystems during simultaneous scans were addressed. For the rat size phantom, the peak noise equivalent count rates (NECR) were 96.4 kcps at 30.2 MBq and 132.3 kcps at 28.4 MBq respectively with and without RF coil. For mouse, the peak NECR was 300.0 kcps at 34.5 MBq and 426.9 kcps at 34.3 MBq respectively with and without coil. At the axial centre of the FOV, spatial resolutions expressed as full width at half maximum / full width at tenth maximum (FWHM/FWTM) ranged from 1.69/3.19 mm to 2.39/4.87 mm. The peak absolute sensitivity obtained with a 250-750 keV energy window was 7.5% with coil and 7.9% without coil. Spill over ratios of the NEMA NU4-2008 image quality (NEMA-IQ) phantom ranged from 0.25 to 0.96 and the percentage of non-uniformity was 5.7%. The image count versus activity was linear up to 40 MBq. The principal magnetic field variation was 0.03 ppm/mm over 40 mm. The qualitative and quantitative aspects of data were preserved during simultaneous scans.
- 21 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 40 (1) , 205-217
Open AccessPerformance Evaluation and Compatibility Studies of a Compact Preclinical Scanner for Simultaneous PET/MR Imaging at 7 Tesla
We present the design and performance of a new compact preclinical system combining positron emission tomography (PET) and magnetic resonance imaging (MRI) for simultaneous scans. The PET contains sixteen SiPM-based detector heads arranged in two octagons and covers an axial field of view (FOV) of 102.5 mm. Depth of interaction effects and detector’s temperature variations are compensated by the system. The PET is integrated in a dry magnet operating at 7 T. PET and MRI characteristics were assessed complying with international standards and interferences between both subsystems during simultaneous scans were addressed. For the rat size phantom, the peak noise equivalent count rates (NECR) were 96.4 kcps at 30.2 MBq and 132.3 kcps at 28.4 MBq respectively with and without RF coil. For mouse, the peak NECR was 300.0 kcps at 34.5 MBq and 426.9 kcps at 34.3 MBq respectively with and without coil. At the axial centre of the FOV, spatial resolutions expressed as full width at half maximum / full width at tenth maximum (FWHM/FWTM) ranged from 1.69/3.19 mm to 2.39/4.87 mm. The peak absolute sensitivity obtained with a 250-750 keV energy window was 7.5% with coil and 7.9% without coil. Spill over ratios of the NEMA NU4-2008 image quality (NEMA-IQ) phantom ranged from 0.25 to 0.96 and the percentage of non-uniformity was 5.7%. The image count versus activity was linear up to 40 MBq. The principal magnetic field variation was 0.03 ppm/mm over 40 mm. The qualitative and quantitative aspects of data were preserved during simultaneous scans.
- 1 June 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (12) , 125007
Initial performance evaluation of a preclinical PET scanner available as a clip-on assembly in a sequential PET/MRI system
We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of eight detectors, each of which comprises a 12 × 12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29 × 29 (30 × 30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU 4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250–750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water-and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage.
- 1 June 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (12) , 125007
Initial performance evaluation of a preclinical PET scanner available as a clip-on assembly in a sequential PET/MRI system
We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of eight detectors, each of which comprises a 12 × 12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29 × 29 (30 × 30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU 4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250–750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water-and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage.
- 15 April 2011
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 71 (8_Suppleme) , 1764
Abstract 1764: DOTA-conjugated antibodies for scintigraphic evaluation of new anti cancer treatments
Introduction: The treatment of cancer is being revolutionized by the development of targeted therapeutic biologics. Translational pharmaco-imaging represents a key step in the evaluation of these new targeted anti cancer therapies. In this respect, we have implemented and validated an antibody radiolabeling process for scintigraphic SPECT imaging.
- 15 April 2011
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 71 (8_Suppleme) , 1764
Abstract 1764: DOTA-conjugated antibodies for scintigraphic evaluation of new anti cancer treatments
Introduction: The treatment of cancer is being revolutionized by the development of targeted therapeutic biologics. Translational pharmaco-imaging represents a key step in the evaluation of these new targeted anti cancer therapies. In this respect, we have implemented and validated an antibody radiolabeling process for scintigraphic SPECT imaging.
- 27 August 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 17, 177-180
Magnetic resonance image segmentation and heart motion tracking with an active mesh based system
- 27 August 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 17, 177-180
Magnetic resonance image segmentation and heart motion tracking with an active mesh based system