Charlie Yi Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charlie Yi Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mark Alan Griswold
Department of Biomedical Engineering Case Western Reserve University Cleveland Ohio USA
2 shared publications - Xin Yu
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Anna Bennett Haller
UC Berkeley–UCSF Graduate Program in Bioengineering University of California, Berkeley and University of California, San Francisco California USA
1 shared publication Avantika Sinha
UC Berkeley–UCSF Graduate Program in Bioengineering University of California, Berkeley and University of California, San Francisco California USA
1 shared publicationBhairav Bipin Mehta
Department of Radiology Case Western Reserve University Cleveland Ohio
1 shared publication- Bryan Clifford
Siemens Medical Solutions USA, Boston, USA
1 shared publication
Latest Publications
- Open Access
- 4 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2263-2277
A flexible MRF approach to improve kinetic rate estimation with bSSFP ‐based hyperpolarized [1‐ 13 C ]pyruvate MRI
Purpose: In this work, we adopt the MR fingerprinting (MRF) framework and leverage its flexibility in quantitative pulse sequence design to propose improved balanced steady‐state free precession (bSSFP)–based hyperpolarized Carbon‐13 ( 13 C) acquisitions for robust metabolic conversion rate quantification. Methods: Spectrally selective bSSFP‐based acquisitions with variable RF excitation were implemented for [1‐ 13 C]pyruvate and used in conjunction with prior implementation of [1‐ 13 C]lactate selective bSSFP imaging. MRF framework parameter estimation was performed using dictionary‐based template matching. Influences of bSSFP‐based acquisitions and sigmoid RF excitation scheme were assessed with simulation experiments and Monte Carlo evaluation. Methods were then compared using experimental data from rat kidney acquired on a clinical 3 T scanner. Results: Simulations indicated that combining bSSFP‐based acquisitions and variable RF excitation (MRF‐Sigmoid) exhibited bias PL ) and noise level investigated when estimating k PL with the MRF framework. bSSFP‐based experiments, with and without sigmoid excitation scheme, showed lower variance in fits at all levels of k PL and noise investigated compared to the method used in prior work by this group (hybrid gradient echo). Positive, linear correlations were found for in vivo voxel‐wise estimates of k PL in healthy rat kidneys when comparing all experiment methods. MRF‐Sigmoid experiment design increased pyruvate cumulative SNR by 3.5‐fold over hybrid gradient echo while maintaining similar lactate cumulative SNR. Conclusion: The use of the MRF framework for k PL estimation demonstrates the feasibility of dictionary‐based template matching and can be used to accurately estimate physiologically relevant k PL and improve cumulative SNR.
- 4 March 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2263-2277
Open AccessA flexible MRF approach to improve kinetic rate estimation with bSSFP ‐based hyperpolarized [1‐ 13 C ]pyruvate MRI
Purpose: In this work, we adopt the MR fingerprinting (MRF) framework and leverage its flexibility in quantitative pulse sequence design to propose improved balanced steady‐state free precession (bSSFP)–based hyperpolarized Carbon‐13 ( 13 C) acquisitions for robust metabolic conversion rate quantification. Methods: Spectrally selective bSSFP‐based acquisitions with variable RF excitation were implemented for [1‐ 13 C]pyruvate and used in conjunction with prior implementation of [1‐ 13 C]lactate selective bSSFP imaging. MRF framework parameter estimation was performed using dictionary‐based template matching. Influences of bSSFP‐based acquisitions and sigmoid RF excitation scheme were assessed with simulation experiments and Monte Carlo evaluation. Methods were then compared using experimental data from rat kidney acquired on a clinical 3 T scanner. Results: Simulations indicated that combining bSSFP‐based acquisitions and variable RF excitation (MRF‐Sigmoid) exhibited bias PL ) and noise level investigated when estimating k PL with the MRF framework. bSSFP‐based experiments, with and without sigmoid excitation scheme, showed lower variance in fits at all levels of k PL and noise investigated compared to the method used in prior work by this group (hybrid gradient echo). Positive, linear correlations were found for in vivo voxel‐wise estimates of k PL in healthy rat kidneys when comparing all experiment methods. MRF‐Sigmoid experiment design increased pyruvate cumulative SNR by 3.5‐fold over hybrid gradient echo while maintaining similar lactate cumulative SNR. Conclusion: The use of the MRF framework for k PL estimation demonstrates the feasibility of dictionary‐based template matching and can be used to accurately estimate physiologically relevant k PL and improve cumulative SNR.
- 12 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2084-2094
3D magnetic resonance fingerprinting with quadratic RF phase
Purpose: To implement 3D magnetic resonance fingerprinting (MRF) with quadratic RF phase (qRF‐MRF) for simultaneous quantification of T1, T2, ΔB0, and .Methods: 3D MRF data with effective undersampling factor of 3 in the slice direction were acquired with quadratic RF phase patterns for T1, T2, and sensitivity. Quadratic RF phase encodes the off‐resonance by modulating the on‐resonance frequency linearly in time. Transition to 3D brings practical limitations for reconstruction and dictionary matching because of increased data and dictionary sizes. Randomized singular value decomposition (rSVD)‐based compression in time and reduction in dictionary size with a quadratic interpolation method are combined to be able to process prohibitively large data sets in feasible reconstruction and matching times.Results: Accuracy of 3D qRF‐MRF maps in various resolutions and orientations are compared to 3D fast imaging with steady‐state precession (FISP) for T1 and T2 contrast and to 2D qRF‐MRF for contrast and ΔB0. The precision of 3D qRF‐MRF was 1.5‐2 times higher than routine clinical scans. 3D qRF‐MRF ΔB0 maps were further processed to highlight the susceptibility contrast.Conclusion: Natively co‐registered 3D whole brain T1, T2, , ΔB0, and QSM maps can be acquired in as short as 5 min with 3D qRF‐MRF.
- 12 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (4) , 2084-2094
3D magnetic resonance fingerprinting with quadratic RF phase
Purpose: To implement 3D magnetic resonance fingerprinting (MRF) with quadratic RF phase (qRF‐MRF) for simultaneous quantification of T1, T2, ΔB0, and .Methods: 3D MRF data with effective undersampling factor of 3 in the slice direction were acquired with quadratic RF phase patterns for T1, T2, and sensitivity. Quadratic RF phase encodes the off‐resonance by modulating the on‐resonance frequency linearly in time. Transition to 3D brings practical limitations for reconstruction and dictionary matching because of increased data and dictionary sizes. Randomized singular value decomposition (rSVD)‐based compression in time and reduction in dictionary size with a quadratic interpolation method are combined to be able to process prohibitively large data sets in feasible reconstruction and matching times.Results: Accuracy of 3D qRF‐MRF maps in various resolutions and orientations are compared to 3D fast imaging with steady‐state precession (FISP) for T1 and T2 contrast and to 2D qRF‐MRF for contrast and ΔB0. The precision of 3D qRF‐MRF was 1.5‐2 times higher than routine clinical scans. 3D qRF‐MRF ΔB0 maps were further processed to highlight the susceptibility contrast.Conclusion: Natively co‐registered 3D whole brain T1, T2, , ΔB0, and QSM maps can be acquired in as short as 5 min with 3D qRF‐MRF.
- 27 October 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (2) , e4435
Quantification of creatine kinase reaction rate in mouse hindlimb using phosphorus‐31 magnetic resonance spectroscopic fingerprinting
The goal of this study was to evaluate the accuracy, reproducibility, and efficiency of a 31P magnetic resonance spectroscopic fingerprinting (31P‐MRSF) method for fast quantification of the forward rate constant of creatine kinase (CK) in mouse hindlimb. The 31P‐MRSF method acquired spectroscopic fingerprints using interleaved acquisition of phosphocreatine (PCr) and γATP with ramped flip angles and a saturation scheme sensitive to chemical exchange between PCr and γATP. Parameter estimation was performed by matching the acquired fingerprints to a dictionary of simulated fingerprints generated from the Bloch‐McConnell model. The accuracy of 31P‐MRSF measurements was compared with the magnetization transfer (MT‐MRS) method in mouse hindlimb at 9.4 T (n = 8). The reproducibility of 31P‐MRSF was also assessed by repeated measurements. Estimation of the CK rate constant using 31P‐MRSF (0.39 ± 0.03 s−1) showed a strong agreement with that using MT‐MRS measurements (0.40 ± 0.05 s−1). Variations less than 10% were achieved with 2 min acquisition of 31P‐MRSF data. Application of the 31P‐MRSF method to mice subjected to an electrical stimulation protocol detected an increase in CK rate constant in response to stimulation‐induced muscle contraction. These results demonstrated the potential of the 31P‐MRSF framework for rapid, accurate, and reproducible quantification of the chemical exchange rate of CK in vivo.
- 27 October 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 34 (2) , e4435
Quantification of creatine kinase reaction rate in mouse hindlimb using phosphorus‐31 magnetic resonance spectroscopic fingerprinting
The goal of this study was to evaluate the accuracy, reproducibility, and efficiency of a 31P magnetic resonance spectroscopic fingerprinting (31P‐MRSF) method for fast quantification of the forward rate constant of creatine kinase (CK) in mouse hindlimb. The 31P‐MRSF method acquired spectroscopic fingerprints using interleaved acquisition of phosphocreatine (PCr) and γATP with ramped flip angles and a saturation scheme sensitive to chemical exchange between PCr and γATP. Parameter estimation was performed by matching the acquired fingerprints to a dictionary of simulated fingerprints generated from the Bloch‐McConnell model. The accuracy of 31P‐MRSF measurements was compared with the magnetization transfer (MT‐MRS) method in mouse hindlimb at 9.4 T (n = 8). The reproducibility of 31P‐MRSF was also assessed by repeated measurements. Estimation of the CK rate constant using 31P‐MRSF (0.39 ± 0.03 s−1) showed a strong agreement with that using MT‐MRS measurements (0.40 ± 0.05 s−1). Variations less than 10% were achieved with 2 min acquisition of 31P‐MRSF data. Application of the 31P‐MRSF method to mice subjected to an electrical stimulation protocol detected an increase in CK rate constant in response to stimulation‐induced muscle contraction. These results demonstrated the potential of the 31P‐MRSF framework for rapid, accurate, and reproducible quantification of the chemical exchange rate of CK in vivo.
- 30 October 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (3) , 1849-1862
Magnetic resonance fingerprinting with quadratic RF phase for measurement of T2* simultaneously with δf, T1, and T2
Purpose: This study explores the possibility of using a gradient moment balanced sequence with a quadratically varied RF excitation phase in the magnetic resonance fingerprinting (MRF) framework to quantify T2* in addition to , T1, and T2 tissue properties.Methods: The proposed quadratic RF phase‐based MRF method (qRF‐MRF) combined a varied RF excitation phase with the existing balanced SSFP (bSSFP)‐based MRF method to generate signals that were uniquely sensitive to , T1, T2, as well as the distribution width of intravoxel frequency dispersion, . A dictionary, generated through Bloch simulation, containing possible signal evolutions within the physiological range of , T1, T2, and , was used to perform parameter estimation. The estimated T2 and were subsequently used to estimate T2*. The proposed method was evaluated in phantom experiments and healthy volunteers (N = 5).Results: The T1 and T2 values from the phantom by qRF‐MRF demonstrated good agreement with values obtained by traditional gold standard methods (r2 = 0.995 and 0.997, respectively; concordance correlation coefficient = 0.978 and 0.995, respectively). The T2* values from the phantom demonstrated good agreement with values obtained through the multi‐echo gradient‐echo method (r2 = 0.972, concordance correlation coefficient = 0.983). In vivo qRF‐MRF‐measured T1, T2, and T2* values were compared with measurements by existing methods and literature values.Conclusion: The proposed qRF‐MRF method demonstrated the potential for simultaneous quantification of , T1, T2, and T2* tissue properties.
- 30 October 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (3) , 1849-1862
Magnetic resonance fingerprinting with quadratic RF phase for measurement of T2* simultaneously with δf, T1, and T2
Purpose: This study explores the possibility of using a gradient moment balanced sequence with a quadratically varied RF excitation phase in the magnetic resonance fingerprinting (MRF) framework to quantify T2* in addition to , T1, and T2 tissue properties.Methods: The proposed quadratic RF phase‐based MRF method (qRF‐MRF) combined a varied RF excitation phase with the existing balanced SSFP (bSSFP)‐based MRF method to generate signals that were uniquely sensitive to , T1, T2, as well as the distribution width of intravoxel frequency dispersion, . A dictionary, generated through Bloch simulation, containing possible signal evolutions within the physiological range of , T1, T2, and , was used to perform parameter estimation. The estimated T2 and were subsequently used to estimate T2*. The proposed method was evaluated in phantom experiments and healthy volunteers (N = 5).Results: The T1 and T2 values from the phantom by qRF‐MRF demonstrated good agreement with values obtained by traditional gold standard methods (r2 = 0.995 and 0.997, respectively; concordance correlation coefficient = 0.978 and 0.995, respectively). The T2* values from the phantom demonstrated good agreement with values obtained through the multi‐echo gradient‐echo method (r2 = 0.972, concordance correlation coefficient = 0.983). In vivo qRF‐MRF‐measured T1, T2, and T2* values were compared with measurements by existing methods and literature values.Conclusion: The proposed qRF‐MRF method demonstrated the potential for simultaneous quantification of , T1, T2, and T2* tissue properties.
- Open Access
- 7 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 22324-22338
Removal of subsurface fluorescence in cryo-imaging using deconvolution
We compared image restoration methods [Richardson-Lucy (RL), Wiener, and Next-image] with measured “scatter” point-spread-functions, for removing subsurface fluorescence from section-and-image cryo-image volumes. All methods removed haze, delineated single cells from clusters, and improved visualization, but RL best represented structures. Contrast-to-noise and contrast-to-background improvement from RL and Wiener were comparable and 35% better than Next-image. Concerning detection of labeled cells, ROC analyses showed RL ≈Wiener > Next-image >> no processing. Next-image was faster than other methods and less prone to image processing artifacts. RL is recommended for the best restoration of the shape and size of fluorescent structures.
- 7 October 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (21) , 22324-22338
Open AccessRemoval of subsurface fluorescence in cryo-imaging using deconvolution
We compared image restoration methods [Richardson-Lucy (RL), Wiener, and Next-image] with measured “scatter” point-spread-functions, for removing subsurface fluorescence from section-and-image cryo-image volumes. All methods removed haze, delineated single cells from clusters, and improved visualization, but RL best represented structures. Contrast-to-noise and contrast-to-background improvement from RL and Wiener were comparable and 35% better than Next-image. Concerning detection of labeled cells, ROC analyses showed RL ≈Wiener > Next-image >> no processing. Next-image was faster than other methods and less prone to image processing artifacts. RL is recommended for the best restoration of the shape and size of fluorescent structures.